CONFIGURABLE SAFETY RELAYS



Similar documents
CONFIGURABLE SAFETY RELAYS

MSI-s/R. Modular Safety Interface. CONNECTING AND OPERATING INSTRUCTIONS Original Instructions. without prior notice /05.

SAFETY LIGHT CURTAINS

Safety automation solutions

SMS 4 / SMS 5 safety mat Product information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

E-STOP relays, safety gate monitors

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Preventa Machine Safety Products

Safety Relays ESM/ESM-F

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

PNOZsigma - Base units

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

Safety Manual BT50(T) Safety relay / Expansion relay

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

PROTECT. Safety Relay Modules PROTECT-SRB s Catalogue Protect/04

g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Expandable with a safe bus system

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Machine Safety Design: Safety Relays Versus a Single Safety Controller

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Barcode Reader Series BCL 31, BCL 32, BCL 34

Smart DeviceNet Remote I/O Terminals

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

DALI RC BASIC SO. Control unit Operating instructions

HERZ-Thermal Actuators

Safety Relay Units. G9SR family. Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities. industrial.omron.

Digital input modules

Three-phase monitoring relay CM-PFE

Electronic Control Devices The European Product Catalogue 2007

Multizone Application >3. MSR300 System. No Software configurable? GuardPLC. Enet RECOMMENDED PRODUCTS. Time Delay MSR138

mecotron Safety relay ESTOP-2 For emergency stop monitoring

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Contact expander modules

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Bul. 440R Guardmaster Safety Relays (DI, DIS, SI, CI, GLP, EM, and EMD) Selection Guide

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Contact expansion modules

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Application Technique. Safety Function: Magnetic Door Switch Monitoring

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

Safety technique. Emergency stop module BO 5988 safemaster

PHOENIX CONTACT Features

SAFETY MANUAL SIL Switch Amplifier

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Original instructions Tina 3A/Aps Adaptor unit

E-STOP relays, safety gate monitors

Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards.

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

38 Series - Relay interface modules A

38 Series - Relay interface modules A

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Model: DC-A2IO Advanced HVAC Controller

E-STOP relays, safety gate monitors

Quick Connect. quick - simple - efficient.

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

Machine Safety Switches

Digital display DA 48

Safety Function: Door Monitoring

RM4TG20 three-phase network control relay RM4-T - range V

E-STOP relays, safety gate monitors

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Telephone- and leased line modem for industrial applications TD-36

PNOZ s3. Safety relays. Operating Manual EN-10

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

40.3. Control Relays and Timers

MINI MCR-SL-R-UI(-SP)

Incubator with mechanical convection

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

L5354 ControlNet Communications Interface

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Tina 2A/B Adaptor unit

NX safety stand-alone

Electric Rotary Actuator - On/Off or programmable control actuator

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Remote Monitoring and REC 501 Control Unit Product Guide

Multi-Range Programmable DC Power Supplies 9115 Series

Inductive sensor NI10-M18-Y1X-H1141

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

E-STOP relays, safety gate monitors

Heating, air-conditioning, cooling

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Transcription:

MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate of two AOPDs and connection of additional Safety Switch Relay switching cycle counting for preventive maintenance (MSI-mx/Rx) Standard initiators, Light Beam or limit switch can be connected as sensors monitored indicators, warning output with indicator failure Potential-free safety-related switching outputs Interface for PC-supported diagnostics function for fast start-up Housing width, 35 mm Integrated functions enable continuous material flow, e.g. for automated production cells or packaging stations, while maintaining the protective function. The protective device assumes the control here of the indicator and in the event of a fault in the sequence guarantees the safe exit of the material to be conveyed out of the line. With the configurable MSI-m, highly productive solutions are very easily implemented in combination with safety sensors. MSI-m is a configurable MSI Safety Relay type 4, in accordance with IEC/EN 6496-, and as the link between the opto-electronic protective devices and the machine control system is equipped for numerous function types: be it Sequential or Parallel. The MSI-mx version even enables Double Parallel for entry and exit areas and the integration of several additional safetyrelated components, such as E-STOP control devices or protective door switches. This extremely compact combination can also further reduce the costs with the implementation of processes. Typical areas of application MSI-m for (bridging the protective device during the material transport) at entry or exit of automated production cells MSI-mx as system solution for connecting Light Beam, hanging flaps and E-STOP control devices Packaging machinery, palletizers, production cells in the automotive industry TNT 35 p. 478 CTi Automation - Phone: 800.894.04 - Fax: 08.368.045 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

MSI-m/R, MSI-mx/Rx Important technical data, overview Type in accordance with IEC/EN 6496- (Annex A) SIL in accordance with IEC 6508 and SILCL in accordance with IEC/EN 606 Performance Level (PL) in accordance with EN ISO 3849- Category in accordance with EN ISO 3849 Stop category in accordance with IEC/EN 6004- Type 4 Up to 4 (depending on the category of the upstream protective device) 0 Supply voltage 4 V DC, ±0 % Response time to 64 ms depending on safety sensor Safety-related switching outputs (OSSDs) Secondary switching device (SSD), only MSI-mx/Rx Ambient temperature, operation Ambient temperature, storage Dimensions (W x H x D) MSI-m/R: relay outputs (NO) MSI-mx/Rx: 3 relay outputs ( NO, NC) Relay output (NO) 0...+55 C -5...+70 C 5.5 mm x 99 mm x 3.6 mm Functions MSI-m/R MSI-mx/Rx Max. number of type AOPDs or E-STOP control devices (category ) 4 Max. number of type 4 AOPDs or E-STOP control devices (category 4) Additional connectable Safety Switch (category 4) 0 Start/restart interlock (RES), optionally with/without Dynamic contactor monitoring (EDM) PC diagnostics interface Sequential Parallel Double Parallel on two areas time monitoring (select/deselect) Warning, defective indicator signal output Relay switching cycle counter for preventive maintenance System error signal output Secondary switching device (SSD) output Features Further information Page Ordering information 467 Electrical connection 468 Technical data 469 Dimensional drawings 47 Accessories ordering information 456 BG geprüft Safety Locking Safety Command Configurable Accessories Glossary Product Finder www.leuze.com/interfaces/ CTi Automation - Phone: 800.894.04 - Fax: 08.368.045 - Web: www.ctiautomation.net - Email: info@ctiautomation.net 465

Ordering information MSI-m/R, MSI-mx/Rx Included in delivery: Connecting and operating instructions Functions:, start/restart interlock, contactor monitoring, PC diagnostics interface MSI-m/R, MSI-mx/Rx Art. no. Article Description Safety-related switching outputs (OSSDs) 549904 MSI-m/R Configurable MSI Safety Relay, relay outputs 549905 MSI-mx/Rx Configurable MSI Safety Relay,, extended functions 3 relay outputs 466 We reserve the right to make changes 5-03_MSI-M.fm 00 Leuze electronic GmbH + Co. KG CTi Automation - Phone: 800.894.04 - Fax: 08.368.045 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

MSI-m/R, MSI-mx/Rx Electrical connection MSI-mx/Rx connection example Safety Locking +4V -A6 -A7 +4V Safety Command S00-M3C-M0 S00-M3C-M0 -M -M3 -M -M4 -K5 -K4 L+ L- -A +4V 3 4 -A Test out Test in SLS 78S +4V 3 4 5 6 -A SLS 78R +4V 3 4 -A Test out Test in SLS 78S +4V 3 SLS 78R 4 5 6 -A5 4 5 4 3 6 7 5 6 34 35 +4V T T S S S3 S4.... M M Test MSI-mx/Rx Diagn. 9 RS3 Var. B -K3 -K4 -K5 AOPDs MSI-fault State Outputs S-S4.-. Indication Output Failure 0 Sensors Warn. M3 Indicators M4 Reset Rx-Output Wam. State 8 9 7 36 33 30 8 9 5 7 6 Var. A -K3 -K4 -K5 x x 3 x x FE (via DIN rail) 3 Indication Output -K3 3 4 -K EDM OSSD L- A A -K3 OSSD3 L- 0 A A -K OSSD SSD A A L+ 3 Configurable Accessories Glossary DIP switch settings: MSI-mx Module Up DS4 DS3 DS DS Down I/O-mx Module MU3 MU Up MU5 MU4 MU Down Product Finder Configurable MSI-mx/Rx Safety Relay with SOLID-4E Safety Light Curtain and S00 Safety Switch Please observe the operating instructions of the components! www.leuze.com/interfaces/ We reserve the right to make changes 5-03_MSI-M.fm 00 Leuze electronic GmbH + Co. KG CTi Automation - Phone: 800.894.04 - Fax: 08.368.045 - Web: www.ctiautomation.net - Email: info@ctiautomation.net 467

Technical data General system data Type in accordance with IEC/EN 6496- (Annex A) Type 4 SIL in accordance with IEC 6508 and SILCL in accordance with IEC/EN 606 Performance Level (PL) in accordance with EN ISO 3849- Service life (T M ) in accordance with EN ISO 3849- Probability of a failure to danger per hour (PFH d ) in nop = 4,800 accordance with the average number of annual nop nop = 8,800 activations (for the calculation formula, see EN ISO 3849-:008, chapter C.4. and C.4.3) nop = 86,400 With DC (ohmic load) With AC (ohmic load) Number of cycles until 0 % of the components have With DC3 (inductive load) a failure to danger (B 0d ) With AC5 (inductive load) Low load (0% nominal load) Category in accordance with EN ISO 3849 Up to 4 (depending on the category of the upstream protective device) Stop category in accordance with IEC/EN 6004-0 Supply voltage 4 V DC, ±0 % ms with connection of type 4 AOPD with transistor output Response time 64 ms with connection of type 4 AOPD with relay output 64 ms with connection of type AOPD 64 ms with connection of (electro-mechanical) Restart delay time 00 ms Safety class II Protection rating IP 0 Ambient temperature, operation 0...+55 C Ambient temperature, storage -5...+70 C Relative humidity Max. 93 % Dimensions (W x H x D) 5.5 mm x 99 mm x 3.6 mm Mounting on 35 mm DIN rail Connection system Plug-in, encoded screw terminals up to.5 mm Current consumption Approx. 00 ma without external load Safety-related switching outputs (OSSDs) MSI-m/R: relay outputs (NO) MSI-mx/Rx: 3 relay outputs ( NO, NC) Outputs, displays s for lamps, 4 V DC/max. 5 W LED indicator, 4 V DC/0.5 W to 5 W Secondary switching device (SSD), only MSI-mx/Rx Relay output (NO) Switching voltage, switching current (for OSSDs) 60 V DC, 50 V AC, 5 A maximum, 0 ma minimum Test interval, 00 ms Test outputs T and T Test pulse width delayed, 4 ms each Response time, type AOPD on test request,...8 ms 468 We reserve the right to make changes 5-03_MSI-M.fm 00 Leuze electronic GmbH + Co. KG CTi Automation - Phone: 800.894.04 - Fax: 08.368.045 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

MSI-m/R, MSI-mx/Rx Technical data Control inputs Start/restart interlock (RES) Contactor monitoring (EDM) sensors M M4 (separate connecting cables required) Signal outputs OSSD status AOPDs status Start/restart function status (RES) Status, error Additional signal outputs MSI-mx/Rx MSI error Status, Status, Safety Switch Pre-selected switching cycles reached indicator, defective Connectable safety sensors Safety sensors (AOPDs) Safety Switch/E-STOP control device Potential-free NO contact (button or key switch) Feedback of positive-guided contacts of sequential contactors sensors, not testable sensors, testable (response time...8 ms) MSI-m/R: type 4 or type 3 AOPD or up to type AOPDs MSI-mx/Rx: Up to type 4 or type 3AOPDs or up to 4 type AOPDs MSI-mx/Rx: Up to 3 in accordance with EN 088 and E-STOP command device in accordance with EN ISO 3850 Safety Locking Safety Command Configurable Please note the additional information in the connecting and operating instructions and at www.leuze.com/interfaces. Product Finder Accessories Glossary www.leuze.com/interfaces/ We reserve the right to make changes 5-03_MSI-M.fm 00 Leuze electronic GmbH + Co. KG CTi Automation - Phone: 800.894.04 - Fax: 08.368.045 - Web: www.ctiautomation.net - Email: info@ctiautomation.net 469

Dimensional drawings Configurable MSI-m/R and MSI-mx/Rx 4 5 3 6 3 6 4 5 7 8 5 8 6 7 9 30 4 5 3 6 3 4 5 6 7 8 5 8 6 7 9 30 Warn. Diagn. Switch Diagn. State Locked S3 & S4 S & S Switch lamp warn. State Locked S & S lamp warn. 99.0 MSI MSI 7 0 Rx - Output MSI- mx 8 9 9 0 3 3 4 34 3 33 35 36 7 0 R - Output 8 9 MSI- m 9 0 3 4 3 3 33 34 35 36 5.5 5.5 3.6 Dimensions in mm Our 3D CAD models can be found under: www.leuze.com/3d-cad-models. Accessories ordering information See page 456. 470 We reserve the right to make changes 5-03_MSI-M.fm 00 Leuze electronic GmbH + Co. KG CTi Automation - Phone: 800.894.04 - Fax: 08.368.045 - Web: www.ctiautomation.net - Email: info@ctiautomation.net