Topic 1 Safety Considerations in Power Supply Design

Similar documents
Safety Considerations in Power Supply Design

Grounding Demystified

Guidance for upgrading to GB (IEC : 2005, MOD)

Guide to the electrical parameter classifications of IEC and IEC safety standards

Calculating Creepage and Clearance Early Avoids Design Problems Later Homi Ahmadi

Product Safety Considerations for Insulation Coordination of Low- Voltage Equipment. Scott Aldous, Compliance Engineer

Dielectric Withstand Testing in a Production Environment

DS 600. A contact free flux gate based current measurement sensor 600A rms

AC-DC Converter Application Guidelines

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

FAQs-Main switchboard design criteria

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

PIN IN PASTE APPLICATION NOTE.

47000 SERIES - ELECTRONIC TRANSFORMERS

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Kit Watt Audio Amplifier

TIG INVERTER INSTRUCTION MANUAL

Safety technique. Emergency stop module BO 5988 safemaster

Power Supplies in Medical Electronics

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Expat Audio Uber Power Supply... 2 Introduction... 2 Revision Control & Edits... 2 The Schematic... 3 Calculating the value of R1,R2 and R3...

Generic - Hearing Loop - (AFILS) U.S. System Specification

Limited Ericsson Internal

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Power Supplies 3. SDN-P DIN Rail Series

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

SYSTEM 4C. C R H Electronics Design

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

LUXEON LEDs. Circuit Design and Layout Practices to Minimize Electrical Stress. Introduction. Scope LED PORTFOLIO

7-41 POWER FACTOR CORRECTION

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

INTEGRATED CIRCUITS DATA SHEET. TDA W BTL mono audio amplifier. Product specification File under Integrated Circuits, IC01

Total solder points: 57 Difficulty level: beginner advanced 3 TO 30VDC / 3A POWER SUPPLY K7203 ILLUSTRATED ASSEMBLY MANUAL H7203IP-1

1 Form A Solid State Relay

Report No: SZESO Date:

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

TEP 200WIR Series, Watt

1 Form A Solid State Relay

Optocoupler, Phototransistor Output, with Base Connection

Drayton Digistat +2RF/+3RF

Unified requirements for systems with voltages above 1 kv up to 15 kv

Video Camera Installation Guide

Kit 27. 1W TDA7052 POWER AMPLIFIER

How To Use A Power Supply Unit (Upu)

3. Design Requirements

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

CompactLogix Power Supplies Specifications

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Optocoupler, Phototransistor Output, AC Input

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Cross-beam scanning system to detect slim objects. 100 mm in

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

How to design SMPS to Pass Common Mode Lightning Surge Test

ST Series POWER SUPPLIES USER INSTRUCTIONS

SYSTEM 45. C R H Electronics Design

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Bourns Resistive Products

Safety of electronic equipment

Section B: Electricity

LOXONE 12 Channel Amplifier

ECEN 1400, Introduction to Analog and Digital Electronics

PRODUCT DATA SHEET AUDIO LINE COMBINATION ALC

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

DATA SHEET. TDA8560Q 2 40 W/2 Ω stereo BTL car radio power amplifier with diagnostic facility INTEGRATED CIRCUITS Jan 08

BB800 Off-Grid Solar System

Low Voltage Products. Switches Automatic Transfer Switches

Series AMLDL-Z Up to 1000mA LED Driver

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

Reducing Injury and Damage Related to Electric Dryer Fires. Fire Containment Tests for the Second Edition of UL 2158

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

Power Management & Supply. Design Note. Version 1.0, Nov DN-EVALMF2ICE2A CoolSET 35W DVD Power Supply with ICE2A265.

A Practical Guide to Dielectric Testing

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

AN583: Safety Considerations and Layout Recommendations for Digital Isolators

Integration of a 400W ac dc power supply into a closed system relying only on natural convection cooling

User s Manual Before using the inverter, you need to read and save the safety instructions.

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

SELECTION GUIDE. Nominal Input

Achat 115MA full-range speaker. user manual

Problem / Solution. The problem:

DATA SHEET. TDA1510AQ 24 W BTL or 2 x 12 W stereo car radio power amplifier INTEGRATED CIRCUITS

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Features. Applications. Truth Table. Close

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Agilent 87421A/87422A Power Supply

Online UPS. PowerWalker VFI 1000R/1U

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.

Emergency lighting units EM powerled

How To Power A Power Control Microprocessor (Power Control) Microprocessor 2 (Power) (Power Power) (Control) (Repower) Microcontroller (Power/Reflow) (Mini) (Microprocessor) (Wired) (Wire

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

Qualitative Analysis of Power Distribution Configurations for Data Centers

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

The first part of this application note, will look at the requirement of the IEEE specifications and how they relate to IEC

Transcription:

Topic 1 Safety Considerations in Power Supply Design Bob Mammano Lal Bahara, Underwriters Laboratories 1-1

Acknowledgment This topic presents a brief overview of a complex subject Prepared from information supplied by Underwriters Laboratories, Inc. More in-depth coverage is available from UL at: UL Customer Service Group E-mail: ULAnytime@ul.com Phone: 1-877-UL-HELPS in America 1-2

Principles of Safety As applicable to power supply design Electric shock Perception, reaction, not-let-go, fibrillation Fire Abnormal operating conditions, faults, overloads Energy hazard Burns from low voltage but high VA (>240 VA) Mechanical Sharp edges, moving parts (injury, insulation damage) Heat related hazards High temperatures at accessible surfaces 1-3

Power Supply Considerations Stand-alone or component supply End product standards apply End use determines applicable standards End product evaluation is adequate for some applications Conditions of acceptability known to user Accessibility To user two levels of protection from hazardous voltages To service personnel guard from inadvertent exposure 1-4

Safety Standards for Power Supplies UL1310 for limited power (<60 V and <8 A) UL1012 for general use in the USA only IEC/EN/CSA/UL 60950-1 primary standard today Information technology equipment and telecom Nearly world-wide acceptance Other standards IEC/EN/UL 60065 for Audio and video IEC/EN/UL 60601 for Medical equipment IEC/EN/UL 61010 for Laboratory Supplies etc. Future consideration IEC 61204-7 Conformance to multiple standards 1-5

Input Ouput Typical Power Supply RF Noise Reduction L Appliance Inlet Wiring Terminals EMI Filter ON/OFF Switch Rectifier DC Filter Linear Regulator Isolator Rectifier Regulator + N PE Primary Wiring Protective Earthing Fuse Switch Mode Control Circuit Switch Mode Regulator - Enclosure (optional) Feedback Different power supply types may have different or fewer blocks. i.e., battery backup, dc/dc converters 1-6

Use Certified Components Many are available to IEC/EN/CSA/UL standards: Power cords or input terminals Protective devices (fuses, etc.) EMI filters Power switch, wiring, PWB, chassis Isolators (transformers, optocouplers) Rectifier assemblies Output connector or terminals Cooling devices Etc. 1-7

Electric Shock Thresholds 0.0 0.5 ma - Perception, minimal reaction 0.5 3.5 ma - Inadvertent reaction, can tolerate 3.5 10 ma - Inability to let go 10 50 ma - Fibrillation, cell damage Threshold is 2 ma dc, 0.7 ma peak, 0.5 ma rms Assumes body resistance of 2 kw at 110 V Resistance decreases with increasing voltage Higher frequencies less harmful Multiply 50/60 Hz value by frequency in khz Maximum current is 70 ma at any frequency Potential for burns if current density is high 1-8

Accessible Safe Voltages LCC (Limited Current Circuit) Current limited to 0.7 ma ac or 2.0 ma dc Under both normal and single-fault conditions Capacitance is limited SELV (Safety Extra Low Voltage) Voltages less than 42.4 V peak ac or 60 V dc Under both normal and single-fault conditions TNV (Telecommunication Network Voltage) Contact area or duration must be limited 71 V ac or 120 V dc, normal conditions at connector pin Higher under single fault if duration < 200 ms Subject to transients of shorter duration 1-9

Unsafe Circuits Protection from operator contact required: Hazardous voltage circuits Voltage in excess of SELV or TNV limits, or if not LCC ELV (Extra Low Voltage) Meeting SELV voltages but not safe under single fault Primary circuits AC mains voltage (hazardous) Secondary circuits with voltage in excess of SELV limits No direct connection to primary 1-10

Insulation Categories Functional - Necessary for operation, no protection Basic - Single level to provide shock protection No thickness spec could have pinholes Supplementary - Additional level added to Basic Includes 0.4 mm min thickness spec for single layer Double - Two levels, Basic plus Supplementary Reinforced - Single system equivalent to Double 0.4 mm min thickness Note: Basic + Basic does not equal Double level 1-11

Insulating Requirements Two levels of protection One level if circuit is not accessible Two levels between accessible components and hazardous voltages Each level of insulation must meet appropriate standards - A single level may fail Double faults not considered Except as a consequence of first fault Hazardous Voltage One level could be protective earth (enclosure) 1-12

Insulation Coordination 1 L Internal Floating ELV 1 L Primary Circuitry (Hazardous Voltage) 1 L 0 L 2 L Internal Grounded ELV Internal Primary Internal Secondary SELV 0 L 2 L 0 L Accessible Secondary Circuitry (Terminals) 1 L 2 L External Grounded Metal External Floating Metal Accessible Metal (Heatsinks) 1-13

Rectifier and Filter Bridge Rectifier Rectifier and Filter Working Voltage Fuse PTC + ve bus 1 B S 3 V1 + SELV L AC Input N PE RFI Filter SW N -ve bus Control Circuit 2 0 Feedback R 4 5 6 V2 SELV L: Line N: Neutral PE: Protective Earthing B: Basic Insulation S: Supplementary Insulation R: Reinforced Insulation The highest voltage between any two conductive devices Can be peak, rms, or dc measured values Determines spacings and insulation thickness 1-14

Insulation Materials Can be solid insulation or air Each level rated for maximum voltage under singlefault conditions Insulating materials rated for operating environment Must be non-hygroscopic Thickness/spacings defined by Pollution Degree Degree 1 = sealed enclosure Degree 2 = office environment Degree 3 = potential conductive atmosphere 1-15

Distance Through Solid Insulation Working Voltage < 71 V No Requirement Above 71 V Functional and Basic have no requirement Supplementary and Reinforced 0.4 mm min thickness Semiconductors and Optocouplers No requirement if: Insulating material is solid Component passes qualification inspection Tested for electric strength during manufacturing External terminations must meet clearance and creepage unless coated 1-16

Optocoupler Options 1 6 2 5 3 4 Terminations to PCB must meet Creepage specs Surface mount pads can meet 8-mm spacing Through-hole pads need special bend or slot 1-17

Spacing of Conductors Clearance = Shortest distance through air Minimum determined by peak voltage Damage can be caused by voltage impulses Creepage = Shortest distance along surface Minimum affected by dc or RMS voltage Damage is slow Insulated Barrier Air Gap Conductors Insulating Surface Clearance Creepage 1-18

Clearance Distances (in millimeters) Working Voltage AC Mains < 150 V (Transient to 1500 V) Pollution levels 1 and 2 AC Mains < 300 V (Transient to 2500 V) (Pollution levels 1 and 2) Peak dc V rms V F B/S R F B/S R 71 50 0.4 1.0 2.0 1.0 2.0 4.0 210 150 0.5 1.0 2.0 1.4 2.0 4.0 420 300 1.5 2.0 4.0 1.5 2.0 4.0 840 600 3.0 3.2 6.4 3.0 3.2 6.4 Partial data from UL60950-1, Section 2.10.3, Table 2H 1-19

Creepage Distances (in millimeters) Working Voltage Pollution Level 1 Material Group III Pollution Level 2 Material Group III Pollution Level 3 Material Group III dc or rms F B/S R F B/S R F B/S R < 50 V 0.4 0.7 1.4 1.2 1.2 2.4 1.9 1.9 3.8 < 150 V 0.6 0.9 1.8 1.6 1.6 3.2 2.5 2.5 5.0 < 300 V 1.6 1.9 3.8 3.2 3.2 6.4 5.0 5.0 10 < 600 V 3.2 3.2 5.0 6.3 6.3 12.6 10 10 20 Partial data from UL60950-1, Section 2.10.4, Table 2L 1-20

Transformer Construction MULTI-LAYER SPACERS OR MARGIN TAPE SECONDARY WINDING CREEPAGE AND CLEARANCE PATH OUTERWRAP Insulating Tape - 3 Layers A B BOBBIN SPACER INSULATION SPACER CORE PRIMARY WINDING PRIMARY WINDING SECONDARY WINDING Creepage and Clearance usually identical Creepage = Clearance = A + B Air exists between all layers Thickness of tape is assumed to be negligible Enamel wire coating not considered as insulation 1-21

Flame Testing V-0 Rating = non-flammable, always acceptable V-1 Rating = Self extinguishing V-2 Rating = Flaming particles ignite cheesecloth V-2 acceptable with solid-bottom enclosure only Selected components throughout supply opened or shorted, or output overloaded Wire insulation with plasticizers provides increased flexibility, but also add to flammability 1-22

Designing For Safety Understand requirement early in program Materials Choose certified components where available Mechanical Securely mounted components No sharp edges or corners No accessible moving parts PCB Layout Define isolation boundary Know working voltage levels Anticipate shorted-component testing 1-23

Primary-Secondary Isolation Isolation spacing clearly visible Slot under opto-coupler 1-24

Circuit Design for Fault Testing High-Voltage Bus R1 Power Transformer Control IC Driver VCC R2 Bias Primary Secondary OUT D1 C1 Z1 R G G D S Q1 Power FET GND D2 High-voltage bias through R1 + R2 R G and D1 protect against Q1 D-G short Use fusible resistor for R G Blown input fuse is OK 1-25

Safety Evaluation Construction analysis Worst-case operational testing Internal working voltage limits Component heating tests Humidity Electric strength measurements Flame tests Additional specialized testing 1-26

Safety Certification Submit documentation package Five open and five enclosed units for testing Six to eight weeks 1-27

For Greater Depth UL conducts one- and two-day seminars Check http://www.ul.com/seminars UL also provides design reviews and EMC testing Refer to UL60950-1 1-28