Beacons and indicator banks Ø 70 optimum Harmony XVE. Catalogue March

Similar documents
Pendant control stations 6

RM4TG20 three-phase network control relay RM4-T - range V

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Signal Tower modulsignal50

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Cross-beam scanning system to detect slim objects. 100 mm in

PROXIMITY CARD READERS C-10, C-20, C60, C70

Safety dialogue solutions

Thermal-Magnetic Circuit Breaker M1-..

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ADM1TE 5/30A DIN rail single phase two wire energy meter

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Electronic overload relay EF19 and EF45

7 Lighting Technology

know-how Giant in distributing electricity for industry Prisma GK

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

49 Series - Relay interface modules A. Features

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Three-phase monitoring relay CM-PFE

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

R.C.C.B. s two-pole LEXIC

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Absolute Rotary Encoder E6CP

Safety detection solutions

48 SERIES Relay interface modules 10 A

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Safety automation solutions

Safety technique. Emergency stop module BO 5988 safemaster

Signal Tower modulsignal70

Electronic overload relay EF65, EF96 and EF146

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Mureva Assembly surface mounted wiring devices

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SMART Board interactive flat panel with appliance Model 8055ie-SMP

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Digital Keypad Use s Manual

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

P System Cubicles. Certified for more safety

SURGE PROTECTIVE DEVICES

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

DuroSite TM High Bay Lighting

Manual motor starter MS116

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

EPIC CIRCON M23 Series Circular Signal Connectors

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Page 162. Page 154. Page 158 Page 146. Page 157. Page 152. Page 160. Page 149. Page 159. Page 156. Page 150

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Pluggable interface relays CR-P Pcb relays

ATL Fuel Level Sender Probes

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Manual Motor Starter MS 116 up to 16 A Technical Data

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Cable Plug acc. to DIN EN , Form A

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

nano led THE GREEN LIGHT

HMI display Installation Guide

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

DECORATIVE RANGES PENDANTS FLUSH FITTINGS WALL LIGHTS TABLE & FLOOR BATHROOM SPOTLIGHTS & DOWNLIGHTS LED STRIPLIGHTS OUTDOOR LED LIGHTING

Drayton Digistat +2RF/+3RF

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

38 Series - Relay interface modules A

Bimetallic Overload Relay Specifications

DS 600. A contact free flux gate based current measurement sensor 600A rms

LC/LCD ranges level controllers

General 1-2-Opto-electronics Safety Switches 4-Emergency

CELO5. User & Installation Manual.

GV- RK1352 Card Reader

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Capacitive Prox E2K-X

Transcription:

Beacons and indicator banks Ø 70 optimum Harmony XVE Catalogue March 04

Contents Beacons and indicator banks b Presentation............................................ page b Description............................................. page b Characteristics........................................ page 4 b References....................................... pages 5 to 7 b Dimensions, mounting, connection...................................... pages 8 and 9

Presentation Beacons and indicator banks 0 Presentation The beacons and indicator banks of the XVE range are designed for remote signalling of the status of a machine, equipment or specific application, either visually using illuminated units which are visible throughout 60 or audibly using an 85 db buzzer. The XVE Optimum range provides efficient signalling (5 colours available), at medium range distances (0 m), in both indoor and outdoor environments. The standard configuration of the beacons and indicator banks is an IP 4 degree of protection, which is sufficient for the majority of indoor applications. Both the IP 4 pre-configured beacons and indicator banks can be upgraded to IP 54 by using a sealing kit (). Depending on the indicator bank base unit selected, it is possible to achieve an IP 54 degree of protection for outdoor usage (). Composition b The beacons are supplied complete and incorporate a single steady or flash light illuminated unit and a short fixing base. They are ready to use. b The indicator banks must be assembled by the user and comprise signalling units, mounted on a base unit, and a fixing base. These various items are to be selected from the catalogue. v For an indicator bank a maximum of 5 illuminated units or 4 illuminated units + audible unit can be assembled. v The illuminated or audible units stack vertically and are easily fitted together. A screw secures their mounting. Electrical connections between each unit are made automatically as the units are mechanically assembled. v All the signalling units are identical in size and their positioning is unrestricted. Signalling functions Steady light signalling Two types of light source are available for steady light signalling: v The incandescent BA 5d base fitting bulb, 5 W max. power, is recommended for infrequent usage and where no vibration or mechanical shock exists. The bulb is not included with the lens unit and must be fitted separately. v LEDs are recommended for continuous usage: 00,000 operating hours without maintenance and low consumption. They have a good resistance to vibration. Using an LED of a colour best suited to the colour of the lens unit provides optimal luminosity. Flashing light signalling Flashing light signalling is also obtained using the LED. It meets requirements regarding reliability, continuous usage and electronic simplicity. A flashing function can also be obtained from a steady light LED illuminated unit by using a PLC output signal. Flash light signalling The light source is a Joule discharge tube which delivers a powerful warning signal. It is available for the 5 colours. Audible signalling Audible signalling is provided by a continuous tone buzzer with a power rating of 85 db at m. Installation Mounting Fixed onto support panel using plastic monobloc fixing base or fixing base comprising an aluminium support tube pre-fitted into a plastic fixing support. Cabling Cabling by means of terminal block incorporated in base unit. The terminals are protected and of the screw and captive cable clamp type. () See page 7. Characteristics: page 4 References: pages 5 to 7 Dimensions: pages 8 and 9

Description Beacons and indicator banks 0 4 5 6 7 Description Illuminated beacon The illuminated beacon is a complete product comprising: A screw fixing cover. One coloured illuminated unit (green, red, orange, blue or clear). A base unit with terminal block and bottom cable entry. 4 A monobloc fixing base for mounting on machine. Indicator bank The indicator bank is a customer assembled product using: 5 A cover. 6 to 5 coloured illuminated units (green, red, orange, blue or clear) with a choice of types of signalling (steady, flashing or flash ). 7 audible unit. 8 A base unit (IP 4 or IP 54) with terminal block and bottom cable entry. 9 A plastic fixing base, 0 mm high. 0 A plastic fixing base, 00 mm high. An aluminium support tube, black or natural finish, length: 00, 400 or 800 mm, pre-fitted and glued into a fixing base. To be ordered separately: Fixing plate for mounting on vertical support. 8 9 0

Characteristics Beacons and indicator banks 0 Environment Degree of protection Conforming to IEC 6059 b IP 4 in vertical position, IP 40 for other positions b IP 54 for reinforced protection version: v for all mounting positions using fixing base XVE Z, v only in vertical position for other heights of fixing base Product certifications e, UL, CSA Approvals CCC (pending) Conformity to standards IEC/EN 60947-, IEC/EN 60947-5- Ambient air temperature For storage C - 40 + 70 For operation C - 5 + 55 Electric shock protection Conforming to IEC 640 Protective treatment Mounted on plastic support tube Mounted on aluminium support tube Class l Class l Standard version: "TC" Electronic components protection (LED and flash) Electrical characteristics Illuminated units By integral fuse in series on the common A 0.6 (z 4 V) A 0.6 (a 0 40 V) With bulb, not included (lens unit only) With integral LED, steady light With integral LED, flashing light Rated insulation voltage (Ui) Conforming to IEC 60947- V 50 50 50 50 With flash discharge tube, Joule Voltage limits Conforming to IEC 60947-5- V 0.85.0 Un (Un: nominal voltage) Light source BA 5d base fitting bulb, maximum power 5 W (40 V max.) Consumption On z 4 V ma Depending on bulb used On z 0 V ma Depending on bulb used On a 0/40 V ma Depending on bulb used Rated impulse withstand Conforming to IEC 60947- kv U imp = 4 voltage Illuminating power Average value for all colours cds/ m² LED LED Flash discharge tube, Joule 8 0 5 on a 4 V 76 on c 4 V 7 0 0 8 640 800 800 Flashing frequency Nominal value Hz Audible units Consumption On z 4 V ma On z 0 V ma 0 On a 0/40 V ma 0 Power Continuous tone db 85 at m Fundamental frequency khz.8 for continuous tone Connection of illuminated and audible units Terminal referencing Connection Maximum clamping capacity on protected, ready-to-tighten, screw and captive cable clamp terminals mm terminal referenced C common to all 5 units 5 terminals referenced to 5 x.5 with cable end Presentation: pages and References: pages 5 to 7 Dimensions: pages 8 and 9 4

References Beacons and indicator banks 0 Illuminated beacons Illuminated beacons with steady light Description Light source Supply voltage Complete unit Bulb, not comprising: included, - screw fixing cover, 5 W max. - illuminated unit, - base unit, - short fixing base Colour of lens unit Reference Weight z 40 V max. Green XVE L 0.45 Red XVE L4 0.45 Orange XVE L5 0.45 Blue XVE L6 0.45 Clear XVE L7 0.45 XVE Lpp Illuminated unit with integral LED z 4 V Green XVE LB 0.50 Red XVE LB4 0.50 Orange XVE LB5 0.50 Blue XVE LB6 0.50 Clear XVE LB7 0.50 XVE Lpp a 0 V Green XVE LG 0.50 Red XVE LG4 0.50 Orange XVE LG5 0.50 Blue XVE LG6 0.50 Clear XVE LG7 0.50 a 0 V/40 V Green XVE LM 0.50 Red XVE LM4 0.50 Orange XVE LM5 0.50 Blue XVE LM6 0.50 Clear XVE LM7 0.50 Illuminated beacons with flash light Description Light source Supply voltage Complete unit Illuminated comprising: unit with - screw fixing cover, Joule flash - illuminated unit, discharge tube - base unit, - short fixing base Colour of lens unit Reference Weight z 4 V Green XVE L6B 0.70 Red XVE L6B4 0.70 Orange XVE L6B5 0.70 Blue XVE L6B6 0.70 Clear XVE L6B7 0.70 XVE L6pp a 0 V Green XVE L6G 0.70 Red XVE L6G4 0.70 Orange XVE L6G5 0.70 Blue XVE L6G6 0.70 Clear XVE L6G7 0.70 a 0 V/40 V Green XVE L6M 0.70 Red XVE L6M4 0.70 Orange XVE L6M5 0.70 Blue XVE L6M6 0.70 Clear XVE L6M7 0.70 XVE Z08 Separate components Description Details Reference Weight IP 54 sealing kit Fixing plate lens unit seal + base unit seal + fixing base seals For mounting beacons on vertical support (requires a fixing base) XVE Z08 0.005 XVB C 0.80 XVB C Description Electrical characteristics Sold in lots of Reference Weight DL BEpS Clear incandescent bulbs with BA 5d base fitting for lens units type XVE Lp 5 W z 4 V 5 W z 0 V 5 W z 0 V 0 DL BEBS 0.00 0 DL BEGS 0.00 0 DL BEMS 0.00 5

References Beacons and indicator banks 0 Indicator banks for customer assembly Composition of an indicator bank: XVE Cp Illuminated units with steady light Description Light source Supply voltage Lens units only Bulb, not included, for BA 5d base 5 W max. fitting bulb Colour of lens Reference Weight z 40 V max. Green XVE C 0.07 Red XVE C4 0.07 Orange XVE C5 0.07 Blue XVE C6 0.07 Clear XVE C7 0.07 Cover and base unit + Illuminated or audible units (5 units max.) + Fixing base XVE Cpp Illuminated units Integral LED z 4 V Green XVE CB 0.077 Red XVE CB4 0.077 Orange XVE CB5 0.077 Blue XVE CB6 0.077 Clear XVE CB7 0.077 a 0 V Green XVE CG 0.077 Red XVE CG4 0.077 Orange XVE CG5 0.077 Blue XVE CG6 0.077 Clear XVE CG7 0.077 a 0 V/40 V Green XVE CM 0.077 Red XVE CM4 0.077 Orange XVE CM5 0.077 Blue XVE CM6 0.077 Clear XVE CM7 0.077 XVE C5pp XVE C6pp XVE C9p Illuminated units with flashing light Illuminated units Integral LED z 4 V Green XVE C5B 0.077 Red XVE C5B4 0.077 Orange XVE C5B5 0.077 Blue XVE C5B6 0.077 Clear XVE C5B7 0.077 a 0 V Green XVE C5G 0.077 Red XVE C5G4 0.077 Orange XVE C5G5 0.077 Blue XVE C5G6 0.077 Clear XVE C5G7 0.077 a 0 V/40 V Green XVE C5M 0.077 Red XVE C5M4 0.077 Orange XVE C5M5 0.077 Blue XVE C5M6 0.077 Clear XVE C5M7 0.077 Illuminated units with flash light Illuminated units Audible units Flash discharge tube, Joule z 4 V Green XVE C6B 0.094 Red XVE C6B4 0.094 Orange XVE C6B5 0.094 Blue XVE C6B6 0.094 Clear XVE C6B7 0.094 a 0 V Green XVE C6G 0.094 Red XVE C6G4 0.094 Orange XVE C6G5 0.094 Blue XVE C6G6 0.094 Clear XVE C6G7 0.094 a 0 V/40 V Green XVE C6M 0.094 Red XVE C6M4 0.094 Orange XVE C6M5 0.094 Blue XVE C6M6 0.094 Clear XVE C6M7 0.094 Description Power Supply voltage Reference Weight Buzzer single tone 85 db at metre z 4 V XVE C9B 0.090 a 0 V XVE C9G 0.090 a 0 V/40 V XVE C9M 0.090 Presentation: pages and 6 Characteristics: page 4 Dimensions: page 9

References (continued) Beacons and indicator banks 0 Indicator banks for customer assembly Base units and covers Indicator bank usage Composition Reference Weight Indoors (IP 4) Base unit and cover XVE C 0.0 XVE C Outdoors (IP 54) Base unit with seal + screw fixing cover + kit comprising 5 seals for lens units and buzzer + seal for fixing base XVE Z XVE CP 0.0 XVB CP Fixing components Description Height under base unit (mm) Colour Reference Weight Plastic fixing bases 0 Black XVE Z 0.040 00 Black XVD C0 0.056 XVE Z XVD C0 Fixing bases comprising: Ø 5 mm aluminium support tube + black plastic fixing support 80 Black aluminium XVB Z0 0.0 Aluminium XVB Z0A 0.0 400 Black aluminium XVB Z0 0.00 Aluminium XVB Z0A 0.00 800 Black aluminium XVB Z04 0.5 XVB Z0 XVB Z0 Aluminium XVB Z04A 0.5 Description For Material Reference Weight Fixing base Ø 5 mm aluminium support tube Plastic XVB Z0 0.050 XVB Z0 XVB C Fixing plate Mounting indicator banks on vertical support (requires a fixing base) Zamak XVB C 0.80 Separate components Description Composition Reference Weight Cover XVE Z08 0.00 XVE Z08 XVE Z08 DL BEpS IP 54 sealing kit Description Clear incandescent bulbs with BA 5d base fitting for lens units type XVE Cp 5 toric seals for lens units + base unit seal + fixing base seal + seal for fixing base XVE Z + screw fixing cover Electrical characteristics 5 W z 4 V 5 W z 0 V 5 W z 0 V Sold in lots of XVE Z08 0.05 Reference Weight 0 DL BEBS 0.00 0 DL BEGS 0.00 0 DL BEMS 0.00 7

Dimensions, mounting, connection Beacons and indicator banks 0 Illuminated beacons Illuminated beacons XVE Lppp Panel cut-out for mounting directly on fixing base 9 Ø70 Ø7 4xØ5,5 Ø54 54 4xØ5,5 54 Mounting on fixing plate XVB C Vertical support panel drillings for mounting fixing plate XVB C Wiring scheme xø5 or M5 C 5 4 5,5 5,5 4,5 4 = = 68 50 Presentation: pages and 8 Characteristics: page 4 References: pages 5 to 7

Dimensions, mounting, connection Beacons and indicator banks 0 Indicator banks Indicator banks XVE Cppp 5 4 5 44 b Cover XVE Z08 or cover XVE C/CP (with base unit), Illuminated units XVE Cpp and/or audible unit XVE C9p, Base unit XVE C/CP, 4 Fixing bases (see below). Height of indicator bank Number of units (ref. ) b unit units 6 units 5 4 units 67 5 units 9 Fixing bases (height under base unit) XVE Z XVD C0 XVB Z0pp Panel cut-out for mounting directly on fixing base b Ø7 4xØ5,5 8 54 00 Ø70 Ø70 Ø70 Height under base unit Fixing base b XVB Z0/Z0A 80 XVB Z0/Z0A 400 XVB Z04/Z04A 800 54 Mounting on fixing plate XVB C Vertical support panel drillings for mounting fixing plate XVB C Wiring scheme 5 4 xø5 or M5 C 5,5 5,5 4,5 5 4 4 = = 68 50 9

Schneider Electric Industries SAS Headquarters 89, bd Franklin Roosevelt F - 9506 Rueil Malmaison Cedex http://www.schneider-electric.com Owing to changes in standards and equipment, the characteristics given in the text and images in this document are not binding until they have been confirmed with us. Production : Schneider Electric Industries Photos : Schneider Electric Industries Printed by : DIA4ED040407EN ART. 096947 Mars 004