Water Main Lining A Sustainable Alternative to Open Cut Replacement



Similar documents
Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

Introduction to Pressure Pipe Rehabilitation with CIPP

LEE S SUMMIT USES PIPE BURSTING TO BROADEN ITS ASSET MANAGEMENT TOOLBOX AND REHABILITATE POTABLE WATER DISTRIBUTION SYSTEM

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

Industrial Pipeline Integrity Management & Remote Polyurea Pipe Lining Systems.

PROVIDING THE SAFE CHOICE FOR UNDERGROUND PIPE RENEWAL, INTEGRITY MANAGEMENT AND ASSET RELIABILITY

Structural Lining for Water Mains. Presenters: Stephen Marcino, PE and Micah Blate, EIT (JMT)

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

Relining of Water Mains with. Flexible High Pressure Pipelines. Raedlinger Primus Line, Inc. Ivan Zubiaga Executive Vice President 2014

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

PRESSURE PIPE REHABILIATION CIPP TECHNOLOGIES

Rehabilitation Alternatives. MWEA Collection System Seminar October 1, 2009

SEWER PIPELINE AND MANHOLE REHABILITATION FOR VARIOUS LOCATIONS WITHIN THE CITY OF BEVERLY HILLS, CALIFORNIA CITY OF BEVERLY HILLS

INSTALLATION OF INSITUFORM LINER

Sewer Pipe Lining An Economic Solution for Pipe Rehabilitation By Tawana Albany Nicholas, Virgin Islands Waste Management Authority

REVIEW OF TRENCHLESS TECHNIQUES FOR THE REHABILITATION OF SEWERS. Gerhard (Gerry) P. Muenchmeyer, P.E. Muenchmeyer Associates, LLC

Greensboro s Pilot Program for Water Pipe Bursting Leads to Expanded City Wide Program

STANDARD SPECIFICATIONS SECTION CLEANING AND LINING WATER MAINS

Pipe Bursting. Case Study at Zeeland, MI Collections Seminar September 6, Presentation Agenda. What is Pipe Bursting? What is Pipe Bursting?

PRODUCT CATALOGUE. for. SMARTPHONE / WEBSITE / DIGITAL EDITION / BOOK / ipad / GPS

Rehabilitation or Replacement? That Is The Question

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

CURED-IN-PLACE PIPE MINIMIZING RISK BY DEFECT CODING

Ultraviolet (UV) Light Cured Fiberglass Reinforced Cured-In-Place Pipe (CIPP) It is not just for sanitary sewer rehabilitation

IS THAT LINER THICK ENOUGH?

The leader in trenchless rehabilitation

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

Water CIPP What to Do When You re Between a Fence and a Hard Place

12/8/2014. Brought To You By: This webcast is sponsored by NASSCO with the support of IPBA.

REHABILITATION OR REPLACEMENT? THAT IS THE QUESTION

Letty Arvide-Gomar, PE

Presented by: Scott E. Belz Project Manager- URS Corporation Robert P. Kelly, P.E. Director of Engineering-City of Westlake James J. Smolik, P.E.

Superior Pipe Restoration Solutions. Proven, state-of-the-art technology that saves money, time and inconvenience. belcopipe.com

SPECIFICATION FOR CURED-IN-PLACE PIPE RENOVATION OF PRESSURE PIPELINES. (As submitted by Insituform Technologies, Inc.)

Utilizing Trenchless Technology to Achieve Watermain Asset Management Objectives

WATER MAIN CONSTRUCTION TECHNIQUES DEPARTMENT OF PUBLIC WORKS WATER & WASTEWATER DIVISION

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

Summary 7/11/2012. Michigan Water Environment Association 2012 Annual Conference Boyne Mountain Resort

GENERAL SPECIFICATIONS AND GUIDELINES FOR INSTALLATION MASTERLINER CURED-IN-PLACE PIPE SYSTEMS

SECTION DUCTILE IRON PIPE AND FITTINGS

02780 LINER FOR SEWER REHABILITATION

PORTLAND BES ADVANCES IN SEWER MAINTENANCE AND REPAIRS BY OPERATING MULTIPLE CIPP CREWS.

ENGINEERING DESIGN GUIDE FOR REHABILITATION WITH CURED-IN-PLACE PIPE Second Edition

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

San Antonio Water System Standard Specifications for Construction ITEM NO POINT REPAIRS AND OBSTRUCTION REMOVALS

Defense Technical Information Center Compilation Part Notice

LIFELINE PIPELINE RESTORATION AND SEISMIC MITIGATION

LS 2540 SEWER LATERALS AND INSPECTION TEES

SECTION POLYVINYL CHLORIDE (PVC) PIPE

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

Section 2320 Cured-In-Place Pipe Lining

SA Pipe Relining is dedicated to finding simple, non intrusive

53.03 MATERIALS FOR SEWER LINER PIPE AND FITTINGS: The following materials are approved for installation in sanitary sewer lines:

San Antonio, TX July 28, 2011

Specification for the Cured-In-Place Pipe Lining of Watermains

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

UNDERGROUND INFRASTRUCTURE SPECIALISTS TABLE OF CONTENTS

SECTION DUCTILE IRON PIPE AND FITTINGS

SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD

PIPE REHABILITATION. Industrial Wastewater Municipal Wastewater Drinking Water Pressure Pipes

Sewer Line Rehabilitation

by Leonard Friesenhahn, P.E.

ASTM C76, Class III, Wall B, except as modified herein. Clean natural sand, ASTM C33. Artificial or manufactured sand will not be permitted.

SASTT contact details:

SECTION ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

THE DEVELOPMENT OF TWO-LAYER LINING METHOD FOR PREVENTING BREAKAGE OF GREY CAST IRON PIPES

SERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS

SECTION POINT REPAIRS TO SANITARY SEWERS. A. Repairs to existing sewer lines by replacing short lengths of failed pipe.

SECTION 802 GRAVITY SEWER PIPE

WEKO-SEAL Internal Joint Sealing WEKO-SEAL. internal pipe-joint sealing

CIPP for Large Diameter Pressure Pipes. Water Research Foundation Large Diameter Pipe Rehabilitation Seminar 20 January 2016 George Bontus, P.Eng.

SECTION 3 SANITARY SEWER DESIGN

APPLICATION OF GLASS-REINFORCED PLASTIC TO SEWER REHABILITATION

Pipe bursting provides viable alternative for rehab work By Greg Key, U.S. Pipe

BROOKS BRIDGE WATERLINE REHABILITATION

CHAPTER 6 - SANITARY SEWER

AWWA Small Systems Pipe Repair Checklist, as published in July 2008 Opflow Question of the Month

Storm Sewer Trenchless Upgrade Alternatives and Recommendations

SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER

SIDE SEWER CONDITION ASSESSMENT AND REPAIR RECOMMENDATIONS

REPAIRS TO DAMAGED SEWERS

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

Trenchless Construction Technology and Issues

WATER SERVICE 2

Waste Collection Systems

Repairs Made With Under Pressure Installations Can Offer Reduced Risks And Expenses

Town House Center Highway North Huntingdon, PA 15642

Sewer Rehabilitation Design Requirements

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

Water Transmission & Sewer Force Main Renewal 16 through 60

REHABILITATION OF THE LONG WHARF SEWER FORCE MAIN USING SLIPLINING METHODOLOGY IN NEWPORT, RHODE ISLAND

SECTION STORM DRAINAGE SYSTEM

City of Virginia Beach Public Utilities HRPDC Regional Construction Standards, 5 TH Edition Amendments May 19, 2014

THE ECOLOGICAL IMPLICATIONS OF TRENCHLESS PIPE REHABILITATION

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

Trouble Shooting for Trenchless Liner Installation During Sewer Line Rehabilitation

Let Us Give Utilities the Respect that they Deserve.

Transcription:

Water Main Lining A Sustainable Alternative to Open Cut Replacement Sean O Dell, PE Baxter & Woodman, Inc. B&W Client Seminar, Crystal Lake May 1, 2014

Agenda Why, What, When, Where, Who, How Reduction in Cost, Time, and Disruption Products / Suppliers / Contractors / Municipalities Installation Process Example Projects Conclusions / Question / Answer

Water Systems are Failing and Budgets are Shrinking

Is There a Strategy to Fix More Pipe with Less Funds? 1. Plan Ahead 2. Rethink our current methods 3. New Technology 4. Replacement vs. Rehab Consider Water Main Rehab

Positives of CIPP Lining Rapid Installation Little Excavation Low Impact on Traffic Improved Flow Characteristics Structural Stability Corrosion Resistance All Green benefits (less dust, noise, gas, etc.) Cost Savings

Open Cut Construction Disruption is Greater than Trenchless

Trenchless WM Rehabilitation Will Reduce Disruption

Trenchless WM Rehabilitation Will Reduce Disruption Open Cut 1,500 sq. yds. Trenchless 250 sq. yds. Existing 8-inh in parkway, ¼ mile

Trenchless WM Rehabilitation Can Reduce Project Cost Replacement: $400 per foot $2,000,000 per mile What if $300 per foot $1,500,000 per mile $500,000 Savings

Total Project Cost is More Than Engineering & Construction Cost

Where to Think About Lining as a Solution? Critical locations rail, pipeline, and road IDOT and County Roads Residential Mains Transmission Mains Busy Right of Ways Minimal Services

Where is Lining Being Implemented in our Region? Glenview Glen Ellyn Crest Hill Park Forest Skokie Naperville Soon Buffalo Grove Downers Grove Lisle LaGrange Streamwood Lombard Aqua Illinois Illinois American Many Large Cities in North America

What is CIPP for Water Main? Materials a) CIPP Tube (Fiberglass Reinforced Felt) b) Thermoset Epoxy Resin Aquapipe Insitumain

CIPP (Potable) Technical References Certifications and Manuals: NSF / ANSI 61 Certification ASTM F1216 and F1743 http://www.astm.org/standards/f1216.htm http://www.astm.org/standards/f1743.htm AWWA M28 IEPA Approved

CIPP for Water Main: Specifications Design Parameters Pipe Condition Depth Design Life: 50-100yrs Groundwater Ovality Soil Modulus Working Pressure Pipe Slope and Bends Laterals Ground Water Soil H D

Spray Epoxy Liner Spectrum Contracting Triton Lining Other Technologies?

Who Supplies the CIPP Liner? IEPA has approved Suppliers/Products Sanexen Aquapipe Insituform Insitumain Blue Norditube Nordipipe (partial)

Licensed Installers FER-PAL Insituform SAK Michels Sheridan Plumbing

Installation Process Temporary By-Pass Dig Access Pits Pipe Cleaning Plugging and Inspecting Installation and Curing Testing Reinstate Services Restore Water Main Service Photos c/o Insituform

Temporary By-Pass Notification Fire Hydrant Connection Pipe on Surface Temp Drive Ramps Home Spigot Connection

Temporary By-Pass Disinfection Security

Temporary By-Pass

Access Pits 1. Traffic Control 2. ~ 6 x 10 x 12 below pipe 3. Minimize locations Valve, Fittings 4. Trench Boxes 5. 300-500 feet

Pressure Pipe Cleaning

Pressure Pipe Cleaning Rust and Scale Deposits need to be removed Cleaning (High-velocity water jetting machines) Mechanically powered equipment Cable attached devices Pipe pigs Rotary Chain-boring Televising (CCTV) Plugging Services

Plugging and Inspecting Internal Pipe Inspection Plugging of Services Televising (CCTV) Leaking water must be stopped Inspection to Owner/Engineer before lining installation 2-inch services??

Liner Installation 1. Impregnate 2. Insertion (Pull / Invert) 3. Pressurize and Circulate Hot Water 4. Cure / Cool / Cut References: ASTM F1216 and F1743 AWWA M28 IDOT Permit

Liner Installation Two Insertion Techniques: Pull Aquapipe Inversion Insitumain

Testing 1. Samples Short-Term Flexural (Bending) Tensile and Thickness Properties Failing Sample Ramifications 2. Pressure Testing ASTM and IEPA 150 psi for 2 hours -or- 1.5 times working pressure for 2 hours

Reinstate Services and CCTV Aquapipe Excess Resin Seal

Reinstate Services and CCTV Insitumain Blue itap TM

Install New Services Small excavation required Stainless steel saddle with multiple O-Ring and rubber grid map (5 or 8 wide) Tapping Bits: Standard for Cast Iron Shell Cutter for Liner

Pit Connections Insitumain Hymax Coupling Connection (see right) Aquapipe No Mech Connection Adhesion Liner Coupling New Pipe

Restore Water Service Disinfection Flushing Restore Permanent Services Dismantle Temporary Services Site Restoration and Cleaning

GPS/TV of Lined Water Main

Example Project - Oak Park, Illinois Ridgeland Avenue CIPP

Example Project - Oak Park, Illinois Lombard Avenue CIPP

Example Project - Crest Hill, Illinois Route 30 Water Main CIPPE

Example Project - Lombard, Illinois Roosevelt Road Water Main CIPP

Example Project - Park Forest, Illinois Sangamon Street Water Main CIPP

Water Main Lining - Points to Remember Literature Review: Can do Will do Engineering Design less effort Plan for worst case Ask the Experts / Contractors / Manufactures Discuss schedule with installers Lead Services Sewer Separation Requirements?

Water Main Lining - More Points to Remember IEPA approved technologies Permit Required 20-40% less expensive than open cut 400-800 foot spans 6 to 20-inch max diameter (currently) >2-inch services cannot be robotically reinstated Liners can span tees & gate valves if you wish to abandon them Extends life by 50+ years

Water Main Lining is a Sustainable Alternative to Open Cut Replacement

Thank you kindly for your attention Sean E. O Dell, PE sodell@baxterwoodman.com 815-482-7853 Cell Phone www.baxterwoodman.com Special Thanks to FER-PAL, Oak Park, Crest Hill, Lombard, Sanexen, Insituform, NASSCO, NASTT, Spectrum