EPIC N57. Uniclass L773. CI/SfB January RoofSafe Anchors with Force Management Technology for PVC Membrane Roof Systems

Similar documents
ROOFSAFE ANCHOR AND CABLE SYSTEM


Fall Protection Solutions

Drum Dispensing Stations

Miller Engineered Solutions Customized Fall Protection Solutions. NEW! Now featuring Rigid Rail Systems

8 overhead Technical Datasheet Pack

SAFETY FENCES, SAFETY BARRIERS AND PEDESTRIAN GUARDRAILS

Rooflight INSTALLATION INSTRUCTIONS

Asphalt Shingle Application Requirements

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

PmB Expansion Joints World leaders in expansion joint technology

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Scope of EN Clarification Document

Safety by XSPlatforms. Safety with a

Uniclass JP3:L782. CI/SfB (5-) ROOF-PRO SUPPORTS FOR BUILDING SERVICES AND ACCESS EQUIPMENT

AMF112 ( <00>) 13mm (1/2 in.)

Connection Solutions

System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY

ACO Water Management: Civils + Infrastructure

AMF112 Instruction Manual

RACKING AND ATTACHMENT CRITERIA FOR EFFECTIVE MEMBRANE ROOF SYSTEM INTEGRATION Public Version 1: July 9, 2012

PivotLoc Ladder Systems

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Davit Systems and Outriggers

Residential Deck Safety, Construction, and Repair

Working at Heights and Fall Protection

Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers

Consultants Handbook

Landscaping products and amenities /

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions

Horizontal Anchorage Device

3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form

SD. Flat roof. Rack Mounting. Installation instructions (2010/11) AU

metal Duil~ing manufacturers Association

Syphonic Roof Drainage

Energy Company Obligation (ECO): Technical Monitoring Questions

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

MANUFACTURED HOUSING USED AS DWELLINGS

Chapter 2 Basis of design and materials

SAN25 ( <00>)

Please check with your local inspection authority for any additional requirements before installation.

Syphonic Roof Drainage

Steel joists and joist girders are

Introduction to Fall Protection

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination

Summit Anchor Company, Inc.

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

SECTION WINDOW WASHING SYSTEMS

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

LAYING BLOCK AND BRICK

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Chapter 3 Pre-Installation, Foundations and Piers

Uptimax New Generation Ni-Cd battery. Maintenance-free solution for backup power applications

Page & Turnbull imagining change in historic environments through design, research, and technology

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig some of the trusses that are used in steel bridges

Fire Resistant Systems

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

STORAGE SYSTEMS PUSH BACK RACK SYSTEMS. Innovative Solutions for Storage and Material Handling Systems

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

The existing roof angle change terminations and flashings when sound and intact can be reused.

CEILING SYSTEMS. CI/SfB (35) Xy April [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

Transmission Foundations. helical piles and guy anchors for transmission structures.

The minimum reinforcement for the stem wall is the placement of:

Bracing Webs in Trusses that have Dissimilar Configurations

Building Owners Guide to a Duro-Last System!

ROOF DRAINS TABLE OF CONTENTS

Mark Cramer Inspection Services, Inc.

Fall Protection System: A system put in place to protect workers from falling. (i.e. installation of guardrails, fall arrest, fall restraint, etc.

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

Pump Division MNR MND. Absorber Recirculation Pumps. Bulletin PS (E)

Audit of a WorkCover Site

7. PRINCIPAL STEPS 8. POTENTIAL HAZARDS 9. RECOMMENDED CONTROLS

Operations and Instruction Manual Might Swivel - Part # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

TARIFF CODE and updates standard

What to Do About Your Roof and How to Hire a Roofing Contractor

Superform Products Ltd.

Installation manual ValkPitched - Clamp

Protecting Your Home from Wind Damage

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Hunter College school of Social Work Thesis Proposal

Installation manual Pitched Roof Clamp System

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Timber Frame Construction

Pipe Cutting and Beveling Clamshells

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

Guidelines for Earthquake Bracing of Residential Water Heaters

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

POLE MOUNT SYSTEM-3 INSTALLATION

UX-30 PERFORMANCE TESTING SUMMARY REPORT Revision 0

-1- SPECIFICATIONS CONE SETTER PLATFORM ATTACHMENT INDEX

Design and Construction of Cantilevered Reinforced Concrete Structures

Roof top Building Services Support Systems

CL90i Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser

INSTALLATION. General. Important Note. Design. Transport

Guidelines for Earthquake Bracing Residential Water Heaters

Transcription:

Uniclass L773 EPIC N57 CI/SfB 20060384 January 2011 RoofSafe Anchors with Force Management Technology for PVC Membrane Roof Systems

RoofSafe Anchors for PVC Membrane Roof Systems 02 contents working safely at heights 02 force management systems 03 anchor installation 03 structural validation 04 anchor construction 04 installation detail 05 green roof systems 05 system design parameters 05 system integration 06 performance tested 06 for more information about our range of equipment visit our website at www.unilinesafety.com working safely at heights Roof work can be a hazardous and high risk activity. The risks can be mitigated and effectively controlled by using a fall protection system in conjunction with management controls and training. Uniline Safety Systems are experts in their field and provide sound advice to assist you in making a well informed safety decision that will reduce the chances of avoidable workplace accidents.

F pre-activation technical drawing stage 1 stage 2 stage 3 F activation technical drawing F MAX 10kN (2,250lbs) post-activation technical drawing how it works Uniline s technically superior RoofSafe Anchors permit many metal decks, plywood and concrete roof constructions to be used as structural anchors, by limiting the forces that are generated in the event of a fall to less than 10kN (2,250lbs) through a built in energy absorber. Built in energy absorbing elements are particularly beneficial in top fix safety anchors as they enable energy to be absorbed throughout the entire fall protection system. This is especially important in short systems and systems with corners, as loads in these cases can be very high and beyond the tolerance of the roof system. Roof anchors which do not incorporate energy absorbing elements, have limited use as anchor devices on metal roof systems. The reaction of the RoofSafe Anchor in the event of a fall re-orientates the load to a more beneficial plane for the roof structure, before deployment of the energy absorber reduces the fall energy and distributes load through the fixings, ensuring the safe arrest of the worker, or workers. 03 pvc membrane roof systems anchor installation The anchor can be fitted to metal decking, plywood or concrete roof constructions from the top of the roof using M8 toggle clamps, mechanical fixings or stud, provided with anti-compression spacers. The length of the toggle bolt can be increased to allow for use in constructions with deep insulation. The number and size of the toggle clamps/stud have been calculated to counter the overturning moment applied by the anchor in the first stage of activation and resist the shear load in the second stage of activation when the energy absorber deploys. When using stud and chemical resin to secure the anchor, it is important to follow the manufacturers specification and installation guidance. toggle clamps top fix solution quick and easy installation

F F uplift forces technical drawing water resistant force management anchor cross section anchor construction 04 RoofSafe Anchors can only be installed on roof systems that have been validated as capable of supporting the distributed loads applied in the event of a fall. Uniline offer alternative solutions for roofs which are not suitable. This predictable distributed load can be used to validate the roof systems suitability for use as a structural anchor. In the case of built up flat roofing systems, the distributed load can vary depending upon the depth of the insulation and can range from 0.5kN/sq.m (10lbs/sq.ft) to 4.0kN/sq.m (84lbs/sq.ft) where insulation is 300mm (0.98ft) deep. Anchors are constructed from mild steel and have a protective corrosion resistant coating. In addition, the base plates are coated with an approved PVC solution to enable the roofing contractor to directly weld the PVC roof membrane to them. An approved PVC Top Hat is also supplied, which provides a 150mm (0.49ft) high waterproofing detail to finish off the installation. The top hat can in turn, be welded to the roof membrane to provide a neat and secure waterproofing detail. Base plates are completely flat to make sealing easier and have recessed fixing points to protect the roof membrane from becoming damaged. Very importantly, no elements of the anchor are exposed to the environment after installation, ensuring longterm corrosion resistance and anchor performance. etailing work must be carried out by an authorised roofing contractor. Integrating Uniline s cable safety systems into your building is made easy and trouble free with Uniline s range of patented RoofSafe Anchors with Force Management technology. The design of the anchor is neat and unobtrusive, limiting any visual impact to the building. type of roof this anchor can be used on: concrete hollow concrete metal deck plywood structural validation

C C C C A B A system configuration technical drawing type A type C type B type The anchors shown above are used for integrating Uniline s cable fall protection systems on to your building, thereby facilitating safe access. Type A: End Anchors Type B: Corner Anchors Type C: Variable Anchors Type : Intermediate Anchors The Type anchor may also be used as a single point anchor. (EN795 class A2). ue to the very large number of roof profiles available in the market place, Uniline carries a wide range of standard stock sizes and can also produce special sizes on request and following validation of the roofing system. For further information, please contact Uniline s Technical epartment. green roof systems Use of Uniline s pre-engineered weather proofing detail enables the anchor to be used in conjunction with Green Roofing Systems. The sedum element of the roof construction can be installed around the anchor without any fear of water penetration through the sealing detail. system design parameters RoofSafe Anchors can be used with RoofSafe Cable systems to provide cost effective and functional safety access solutions. esign requirements for the anchors are; RoofSafe Cable: 12m (39.37ft) maximum span (systems less than 12m (39.37ft) must have at least one intermediate anchor). RoofSafe Cable provides continuous hands free access for the user of the system. System designs must be calculated using Uniline for Windows software in order to ensure that the proposed layout can support the number of workers intended to use the system in the future. Furthermore the software will advise on the ground clearance required beneath the work area in order to safely arrest a fall. Uniline provide technical drawings and specification details to help Architects and Building Safety Engineer s with the inclusion of its products in building specification documents and tenders, no matter how complex your requirements may appear. Local design support can be provided by our network of System Integration Specialists. 05 green roof system RoofSafe cable RoofSafe cable

installer training testing the system 06 system integration RoofSafe Anchors and Cable systems should only be designed and fitted by companies and personnel authorised and trained to do so. Uniline operates a training programme for its installation personnel to ensure competence. Installation technicians carry a competence record showing that they have been trained in the correct installation techniques required for our products. Uniline operates this system for your peace of mind and the safety of the people that will use our products in the future. It is an integral part of our ISO9001:2000 quality system and ensures high standards are maintained. performance tested RoofSafe Anchors are tested to exceed the standards of EN795, are CE marked and come with a 10 Year Guarantee for performance and corrosion resistance. (Subject to terms and conditions). For your peace of mind Uniline operates an ongoing policy of testing on as built roof constructions and has achieved approvals from many manufacturers of roof systems.

Capital Safety Group, through our Uniline brand is the global market leader in the design and manufacture of engineered fall protection systems. Through a combination of expert knowledge and practical experience, we can help our customers reduce risk and increase safety when working at height. Our comprehensive Uniline range of products offers fully compliant, practical solutions for structures of all types, in all industries. Our ethos of delivering quality, service, training and support for our customers has earned Uniline a deserved reputation for excellence around the world. Operating through specialist safety companies globally, Uniline provides local support and installation services to meet the specifi c safety objectives of all our customers. If you need a safety solution for roof access during maintenance and inspection tasks, then look no further than Uniline s Roofi ng product range. Our products, including roof anchors, horizontal lifelines & horizontal rail systems offer comprehensive protection for workers on all types of roofs. The products in our Horizontal systems range are some of the best know brands in fall protection safety. The versatility of these products combined with Uniline s expertise in fall protection ensures we can solve even the most complex of height safety problems in industry, construction, façade access and for all manner of building maintenance and inspection tasks. The best vertical fall protection systems in the world won t let you down. The extensive development of this range of products for vertical structures including masts, towers, pylons, wind turbines, silos, bridges and chimney stacks ensures customers will enjoy the safest and most functional climbing experience possible. A unique range of custom access products for challenging fall protection situations in transport and industry. These solutions are structurally analysed and designed to our customers exact needs and specifi cations. local distributor/systems integrator Worldwide Locations UK 5a Merse Road North Moons Moat Redditch, Worcestershire B98 9HL UK t: +44 (0) 1527 548 000 f: +44 (0) 1527 591 000 EUROPE, MILE EAST & AFRICA Le Broc Center Z.I. 1re Avenue BP15 06511 Carros Le Broc Cedex FRANCE t: +33 (0)4 97 10 00 10 f: +33 (0)4 93 08 79 70 USA 3833 SALA Way Red Wing MN 55066 USA freephone: 800 328 6146 t: +1 (651) 388 8282 f: +1 (651) 388 5065 CANAA 260 Export Boulevard Mississauga Ontario L5S 1Y9 CANAA freephone: 800 387 7484 t: +1 (905) 795 9333 f: 888 387 7484 AUSTRALIA & NEW ZEALAN 95 erby Street Silverwater NSW 2128 AUSTRALIA freephone: 1800 245 002 (AUS) freephone: 0800 212 505 (NZ) t: +61 2 8753 7600 f: +61 2 8753 7603 ASIA No 6 Tuas Avenue 18 638892 SINGAPORE t: +(65) 65587758 f: +(65) 65587058 www.capitalsafety.eu www.unilinesafety.com