WHI TEST REPORT #630-104800 FIRE RATED DOORS



Similar documents
REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

Steel Door Institute. Fire Rated Doors and Frames

Basic Fire Door Requirements

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

How To Test For An Architectural Test

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Subject: DKS Steel Door and Frames Systems, Inc., ITS / Warnock Hersey Procedural Specification, Certification, and Inspection.

White Paper FIRE DOOR INSPECTIONS, REPAIRS AND LABELING

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

TEST REPORT. Rendered to: INTERNATIONAL WINDOW Hayward, California. PRODUCT TYPE: Aluminum Hopper SERIES/MODEL: 7222

CHECKLIST FOR DOOR HARDWARE

City of San Diego, CWP Guidelines

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS

PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems

Fire-Rated Doors and Hardware. A Guide to Field Inspection

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

MOCK-UP TEST REPORT. Rendered to: TUBELITE, INC. PROJECT: 200 Series Curtain Wall Mock-Up

Office of the State Fire Marshal. Fire Rated Doors

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

PERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM CORPORATION. SERIES/MODEL: 450 Center Glaze PRODUCT TYPE: Aluminum Curtain Wall

PERFORMANCE TEST REPORT. Rendered to: TREMCO INCORPORATED. SERIES/MODEL: Proglaze ETA PRODUCT TYPE: Engineered Transition Assembly

Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art

Premier & Deluxe 3-Season Room Sliding Glass Door

IN00419 (rev A) Aqua 6 Glide Quadrant and Off-set Quadrant Enclosure

WARNING: Important: Keep these instructions for future reference. Gate Instructions (1) Assembly and Installation Instructions

Sun Windows General Information Sun New Construction Window Installation Instructions

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: CAPTIVEAIRE, INC. Blue Bell, Pennsylvania

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

Classroom Door Security & Locking Hardware

HVAC Air Duct Leakage. Eli P. Howard, III Group Director Technical Resources SMACNA

ATI Evaluation Service A Division of Architectural Testing Certification Services

TEST REPORT. Report No.: B Rendered to: CROFT, LLC. Magnolia, Mississippi. PRODUCT TYPE: Aluminum Single Hung Window SERIES/MODEL: 95

Code of Practice for fire resisting metal doorsets

5800 Temperature Sensor Cable Assembly

ILLUSION FRAMELESS SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Destiny Shower Enclosure Installation Instructions

Tremco Fire Protection Systems Group Technical Bulletin

SECTION 6. Glass Storefront Doors:

Report Number BTC 17755F

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

SECTION SERIES 1500 VINYL PATIO DOORS

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC

Can you design a frameless shower enclosure that doesn't leak?

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

All-Season Sunroom Sliding Glass Door Installation Instructions

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: NORSE, INC.

Glossary. 1/3 1/3 1/3 - Configuration of a vent-fixed-vent (xox) window in which the vents and fixed panel are equal sizes

EMF/EMR. Holder/Release Devices with Integral Door Closers

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES

INSTRUCTION FOR ASSEMBLY. 150x180 v Traditional sauna cabin

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: AMERICAN PRODUCTS, INC Tampa, Florida

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

STANDARD FOR NON-FIRE RATED ROLLING DOORS

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

Astragal: a vertical member placed at the meeting edges of a double door to provide a weather seal and may be used to anchor the fixed door.

TEST REPORT. Rendered to: BRISTOLITE SKYLIGHTS Santa Ana, California

REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES

Fire Barriers & Fire Stopping

280+ Mortise Mounted Series Shear Locks Special Application Solution

Important Information

HMMA 830 HARDWARE SELECTION FOR HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL -02 NAAMM STANDARD METAL DOORS & FRAMES NAAMM 01 NAAMM 01

IMPORTANT INFORMATION

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

majestic install ation guide barcelona three sided enclosure 24mm surface mounted wall channels and underframe to base

Ceiling Mounted Folding Attic Ladders Installation Instructions

AirBlock Data Center Doors

Integral Kit Instructions

Installation Detailed installation instructions are provided which should be strictly followed.

Beautifully Traditional

CLEAR-DIVISIONS CENTERFOLD

AirBlock Data Center Doors

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Comment Form on Proposed Gut Rehabilitation Alternatives

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Core and Frame Details

ROOF TOP MOUNTED Air Handler Specification

Gypsum Board Systems Manual

Mark Cramer Inspection Services, Inc.

19 DYNAmax Free Standing Server C A B I N E T s

5.1. Smoke Sealing. General: The test procedure for smoke sealed doorsets is given by reference to BS476 Section 31.1.

19 DYNAmax Free Standing Server C A B I N E T s

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

Reduced depth High Density Cabinet HDC with 19 swing frame 36, 40 and 45 U

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Lightweight Partition Design for Residential and Commercial Buildings

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: CR LAURENCE CO., INC. SERIES/MODEL: 7500 Concealed Vent TYPE: Projecting (Awning)

AZEK Rail Install Guide

Transcription:

8000 Whitepine Rd. Richmond, VA 23237 Tel: 800-446-7325 Fax: 800-448-2908 E-mail: weatherseal@sealeze.com WHI TEST REPORT #630-104800 FIRE RATED DOORS REPORT OF TEST OF GASKETING FOR RESISTANCE TO AIR FLOW AT ELEVATED TEMPERATURE TO DETERMINE EFFECTIVENESS AS A SMOKE CONTROL DOOR SEAL FOR SEALEZE CORPORATION RICHMOND, VIRGINIA BY WARNOCK HERSEY INTERNATIONAL, INC. 8431 MURPHY DRIVE MIDDLETON, WISCONSIN 53562 TEST DATE: MAY 28, 1991 REPORT DATE: JUNE 14, 1991 Warnock Hersey International, Inc. (WHI) hereby authorizes the above named client to reproduce this report only in its entirety. The product described herein has met the performance requirements to be eligible for a WHI certification program. This report does not automatically imply certification. Products must bear WHI labels in order to demonstrate WHI certification. This test report applies only to the exact size and construction of assembly listed in the specimen description of this report.

INTRODUCTION Warnock Hersey International, Inc. conducted smoke leakage tests on Sealeze Corporation s Therm-L-Brush II product on May 28, 1991. The tests were conducted in accordance with UL standard UL 1784, First Edition, June 29, 1990. Standard for Air Leakage Tests of Door Assemblies. A 1 long Therm-L-Brush II products was tested applied to a 3 0 x 7 0 hollow metal door mounted in a steel frame. DESCRIPTION The Sealeze Corporation Therm-L-Brush II is a brush type gasketing consisting of a dense pile of fine proprietary nylon filaments. The brush is supplied on a metal spline, which slides into extruded aluminum mounting strips also manufactured by Sealeze Corporation. The smoke control door assembly tested was a standard 3 0 x 7 0 hollow metal steel door mounted in a steel fire door frame with 5.8 high stops. The Therm-L-Brush assembly with 1 long bristles mounted in aluminum holders supplied by the manufacturer was applied to the frame stops with self-drilling screws. The screws were applied at 6 centers through slots prepared in the aluminum holders. The holders provide a 45 angle between the brush and door surface. The gasket was adjusted following the written instructions supplied with the product by Sealeze Corporation. PROCEDURE The doors were mounted in the frame and adjusted to obtain a 1/8 gap between the edges and top of the door and the frame. The frame used was a communicating type so that the doors used could be mounted in either an in-swing or out-swing position. The doors were mounted with standard 4 hinges at three locations and a single point cylindrical latch. The gasketing was applied to the frame stop and adjusted so that the brush material was deflected at 30 from straight when the door was closed. The same mounting and test procedure was used for both the in-swing and out-swing test configurations with a new door and brush used for each test. After installation of the door, frame and gasket, the door was cycled open and closed five times. The closing force was then measured following the procedure specified in the test standard. Background leakage rates were measured at both ambient and elevated temperatures by sealing the door to the frame with aluminum foil tape. Air leakage measurement was made at pressure differentials of.05,.10,.20 and.30 inches of water column at both ambient and elevated temperatures. For all tests the threshold and bottom 2 inches of the door were sealed with aluminum tape.

EQUIPMENT The following equipment was used to conduct the test and measurements. Measured Parameter Instrument Accuracy 1 Air Flow Orifice Plate/Inclined Manometer + 2% 2 Chamber Inclined Manometer +.002" w.c. Pressure 3 Chamber Array of 12 Type K Thermocouples + 1.5 F Temperature 4 Make-up Air Type KJ Thermocouple and + 1 F Temperature Digital Readout 5 Barometric Mercury in Glass Barometer +.01" Hg. Pressure The test chamber is constructed of structured steel and is sealed with RTV silicone at all joints. The frame/door assembly was mounted in a wood stud/gypsum wall assembly mounted to the face of the chamber. All joints within the wall assembly and between the wall and door frame were sealed with silicone caulk.

RESULTS The following air leakage rates were obtained. TEST 1. Swing Direction: Hinge Side: Closing Force: Out-Away from chamber Left 6 lbf. TEST TEST NET LEAKAGE MAX. PER NEPA PRESSURE TEMP. LEAKAGE RATE 105 REQ. (M.W.C.) ( F) (SCFM) (SCFM/FT 2 ) (SCFM/FT 2 ) 0.05 81 9.73 0.46 0.10 81 15.81 0.75 3 (ELEVATOR LOBBY) 6 (ELEVATOR PRES. HOIST WAY) 0.20 82 25.52 1.22 0.30 82 30.33 1.44 11 (STAIR ENCLOSURE PRESSURIZED) 0.05 406 8.35 0.40 1.5 (ROOM TO CORRIDOR- PRESS.) 1.0 (CROSS CORRIDOR) 0.10 402 16.49 0.79 1.5 (ROOM TO CORRIDOR) 0.20 408 19.13 0.91 2 (AREA OF REFUGE) 0.30 400 34.01 1.62 TEST 2. Swing Direction: Higes: Closing Force: In=Into chamber Left 5 lbf. TEST TEST NET LEAKAGE MAX. PER NEPA PRESSURE TEMP. LEAKAGE RATE 105 REQ. (IN. W.C.) ( F) (SCFM) (SCFM/FT2) (SCFM/FT2) 0.05 83 11.8 0.56 0.1 82 18.04 0.86 3 (ELEVATOR LOBBY) 6 (ELEVATOR PRESE. HOIST WAY) 0.2 83 27.99 1.33 0.3 83 39.67 1.84 11 (STAIR ENCLOSURE PRESSURIZED) 0.05 395 0.41 0.02 1.5 (ROOM TO CORRIDOR- PRES.) 1.0 (CROSS CORRIDOR) 0.1 406 5.06 0.24 1.5 (ROOM TO CORRIDOR) 0.2 402 12.81 0.61 2 (AREA OF REFUGE) 0.3 400 21.54 1.03

CONCLUSION All leakage rates were below the maximum suggested in NFPA 105 (1989 Edition) when the door bottom was sealed. Bottom seals were not evaluated in this project due to the wide range of floor covering materials which are likely to be encountered in the field and the fact that bottom seals are not usually required for smoke control purposes. Bottom seals when required should be specifically evaluated in combination with floor covering type and an appropriate leakage rate factor added to the measured leakage rate for the rest of the smoke control assembly.