SERIES & VAC Microprocessor Based Direct Spark Ignition Control with or without Combustion Blower Relay FEATURES APPLICATIONS

Similar documents

G670 Intermittent Pilot Ignition Controls

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

Model Description / Applications. Intermittent Pilot Gas Ignition Control

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

, User s Manual

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

GeniSys 12V. Model Description / Applications. Advanced 12 Vdc Burner Control


INSTALLATION & SERVICE MANUAL. Display Panel

User Manual for CH-PFC76810

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

WARNING CAUTION 21V51U-843 DESCRIPTION PRECAUTIONS

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

DVI 980/982 (Honeywell Nr. S4865) Gas Burner Safety Control

Fossil fuel heating equipment

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

Installation Instructions

Gas Oven Repair Guide

Fan Coil EC Motor Control

Manual for Fire Suppression & Methane Detection System

DKG 972 Gas Burner Safety Control

TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

TIG INVERTER INSTRUCTION MANUAL

Digi-Motor Installation Guide

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

PRODUCT DESIGN. 5. Furnace awaits call from thermostat.

Luna 3 Comfort Troubleshooting Guide June 2008

S8910U Universal Hot Surface Ignition Module

80UHG. Service Literature

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Air Conditioning Sign-Off Sheet

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

Your safety and the safety of others are very important.

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

T7560A,B,C Digital Wall Module

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

E2 Series Electric Furnaces

DLP-PU/E Instruction Manual

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

ADM1TE 5/30A DIN rail single phase two wire energy meter

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

TC-9102 Series Surface Mount Temperature Controllers

Operator: Save these instructions for future use!

Drayton Digistat +2RF/+3RF

Manual Ranging MultiMeter

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Commercial Gas Furnace Upflow

CONTROLS KITS AND ACCESSORIES /2014 Supersedes10/2014

Oil and Coolant Circulating Heating System. Model - OCSM

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Munchkin Heat Exchanger Maintenance

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

RADIANT PLASMA 4700 Plasma Spark Generator

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

SL280UHV SERIES GAS FURNACE WARNING

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Veri-Flame Single Burner Monitoring System

For installation guide see reverse of book

Installation and Operation Guide for PD4100 Series Power Control Centers

Cooling Capacity CFM in. w.c. (125 Pa)

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

7800 SERIES Relay Modules

Technical Data. Dimensions

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Stove Guard Kit User Manual

Tankless Gas Water Heaters Second Generation Indoor, Outdoor and Direct Vent Up to 199,000 BTU

ACS-30-EU-EMDR-10-MOD

WD-AMX Water Detection Controllers

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

DALI RC BASIC SO. Control unit Operating instructions

12 Volt 30 Amp Digital Solar Charge Controller

LITHIUM BATTERY CR123A SPECIFICATION

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

StructureScan HD Module. Installation Guide ENGLISH

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Q309A,B; Q335C; Q340A; Q390A Thermocouples and Q313A,B,C,F Thermopile Generators

Transcription:

SERIES 35-60 & 35-61 24 VAC Microprocessor Based Direct Spark Ignition Control with or without Combustion Blower Relay 35-60,-61 FEATURES 24 VAC microprocessor based DSI control Pressure switch monitoring System diagnostic LED Alarm output (normally closed contact) Automatic reset 1 hour after lockout* Custom prepurge and interpurge timings** Multiple tries for ignition Remote or local flame sensing Flame sense test pins APPLICATIONS Gas Furnaces Boilers Water Heaters Commercial Cooking Other Similar Appliances DESCRIPTION The Series 35-60 and 35-61 are 24 VAC Microprocessor Based Direct Spark Ignition Controls designed for use in all types of heating applications. The control utilizes a microprocessor to continually and safely monitor, analyze and control the proper operation of the gas burner. Value added features such as combustion blower control, LED diagnostics, automatic one hour reset, and flame current test pins highlight the controls benefits. SPECIFICATIONS Input Power Voltage Current Output (Contact Ratings) Gas Valve Combustion Blower (Model 35-61 only) Control: Line: 18 to 30 VAC 50/60 Hz (Class 2 Transformer) 120 or 240 VAC (L1 & IND contacts only) 300 ma max @ 24 VAC with blower and gas valve relay energized (Control only) 2.0A max @ 24 VAC 3.0 FLA @ 120 VAC (6.0 LRA) 1.5 FLA @ 240 VAC (3.0 LRA) 1/4 H.P. Motor Agency Certifications UL Component Recognized System. Design certified to UL 372, file MH8817. Software conforms to UL 1998 requirements. Design Certified to ANSI Z21.20, CAN/CSA C22.2 No. 199-M89 CE Approved to EN 298:2003 Certified to Standards AG206 and AG210 * Automatic reset after 1 hour is not allowed for CE approved models ** Prepurge time cannot exceed interpurge time on CE models Operating Temperature Flame Sensitivity Flame Failure Response Time Types of Gas Spark Rate Size (LxWXH) Enclosure Moisture Resistance Weight Tries for ignition Trial for ignition Periods Prepurge & Interpurge Edge Connect Version -40ºF to +176ºF (-40ºC to +80ºC) 0.7μA minimum 0.8 seconds maximum Natural, LP, or manufactured Line frequency (50/60 sparks/ sec.) 5.684 x 3.934 x 1.875 (with cover) 5.281 x 3.718 x 2.080 (edge connect) Gray (Noryl N-190) fire retardant plastic Conformal coated to operate non-condensing to 95% R.H. Care must be taken to protect module from direct exposure to water 8 oz including cover One or three try versions available 4.0, 7.0, 10.0, or 15.0 seconds standard Contact factory for other settings None, 15, or 30 seconds depending on model. Without prepurge there is a one second delay before the first try for ignition Optional Edge connect model for replacement product 35-60 and 35-61, 24 VAC DSI Control with or without Blower Relay Page 1

SEQUENCE OF OPERATION / FLAME RECOVERY / SAFETY LOCKOUT Power Up / Stand By 35-61 Models only: Upon applying power (24 volts) to 24VAC(R), the control will reset, perform a self check routine, flash the diagnostic LED, and enter the thermostat scan state. Call for Heat 35-60 Models: When a call for heat is received from the thermostat supplying 24 volts to, the control will reset, perform a self check routine, flash the diagnostic LED, and a pre-purge delay begins. Following the pre-purge period the gas valve is energized and sparks commence for the trial for ignition period. 35-61 Models: When a call for heat is received from the thermostat supplying 24 volts to, the control will check the pressure switch for normally open contacts. The combustion blower is then energized and once the pressure switch contacts close, a pre-purge delay begins. Following the pre-purge period the gas valve is energized and sparks commence for the trial for ignition period. Ignition - 35-60: When flame is detected during the trial for ignition, sparks are shutoff immediately and the gas valve remains energized. The thermostat and main burner flame are constantly monitored to assure the system continues to operate properly. When the thermostat is satisfied and the demand for heat ends, the main valve is de-energized immediately. Ignition - 35-61: When flame is detected during the trial for ignition, sparks are shutoff immediately and the gas valve and combustion blower remain energized. The thermostat, pressure switch, and main burner flame are constantly monitored to assure the system continues to operate properly. When the thermostat is satisfied and the demand for heat ends, the main valve is de-energized immediately, the control senses the loss of flame signal and initiates a post-purge period (optional) before de-energizing the combustion blower. Failure to Light SINGLE TRIAL MODEL Should the main burner fail to light, or flame is not detected during the trial for ignition period, the control will go into lockout. The valve will be turned off immediately. For the 35-61 series, the combustion blower will be turned off following the optional post purge period. MULTI TRIAL MODEL Multi-try Models will attempt two additional ignition trials before going into lockout. The valve relay will be de-energized immediately, and for the 35-61 Series the combustion blower will be turned off following the optional post purge period. Lockout and Reset Recovery from lockout requires a manual reset by either resetting the thermostat or removing 24 volts from 24 VAC(R) for a period of 5 seconds. If the thermostat is still calling for heat after one hour the control will automatically reset and attempt to ignite the burner again. Flame Failure - Re-Ignition If the established flame signal is lost the control will respond within 0.8 seconds. The HV spark will be energized for a trial ignition period in an attempt to relight the burner. If the burner does not light the control will de-energize the gas valve. Multi-try models will make two more attempts to relight the burner. If the burner does not relight the control will go into lock out as noted above in Failure to Light. If flame is re-established, normal operation resumes. Recycle mode, which closes the valve and executes a pre-purge delay is available as an option. Combustion Airflow Problems - Lockout 35-61 Models only: Combustion air flow is continually monitored during an ignition sequence by the pressure switch (PSW). If during the initial call for heat the switch contacts are in the closed position for 30 seconds without the Combustion Blower being energized, an air flow fault will be declared and the control will remain in this mode with the combustion blower off. If the pressure switch remains open for more than 30 seconds after the combustion blower output (L1 & IND) is energized, an air flow fault will be declared and the control will stay in this mode with the combustion blower on, waiting for the pressure switch to close. When proper air flow is detected from the pressure switch input (PSW) the control begins the prepurge period with a normal ignition sequence following. If the air flow signal is lost while the burner is firing, the control will immediately de-energize the gas valve and the combustion blower will remain on. If the call for heat remains, the control will wait for proper air flow to return. If proper air flow is not detected after 30 seconds an air flow fault signal will be declared. If proper air flow is detected at any time, a normal sequence will begin with the prepurge period. Flame Fault If at any time the main valve fails to close completely and maintains a flame, the flame sense circuit will detect it and energize the combustion blower. Should the main valve later close completely removing the flame signal, the combustion blower will be turned off following the optional post purge period. Page 2 35-60 and 35-61, 24 VAC DSI Control with or without Blower Relay

Fault Conditions Error Mode Internal Control Failure Air Flow Fault (35-61 Only) Flame with No Call for heat Ignition Lockout LED Indication Steady on 1 Flash 2 Flashes 3 Flashes The LED will flash on for 1/4 second, then off for 1/4 second during a fault condition. The pause between fault codes is 3 seconds. MOUNTING AND WIRING The Series 35-60 and 35-61 controls are not position sensitive and can be mounted vertically or horizontally. The case may be mounted on any surface with #6 sheet metal screws. All wiring must be done in accordance with both local and national electrical code. WARNING: The Series 35-60 and 35-61 use voltages of shock hazard potential. Wiring and initial operation must be done by a qualified service technician. The control must be secured in an area that will experience minimum vibration and remain below the operating temperature of 160ºF. All connections should be made with UL approved 105ºC rated 18 gauge, stranded,.054 thick insulated wire. Refer to wiring diagram when connecting the control to other components in the system. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. A functional checkout of a replacement control is recommended. CONNECTION LIST - 35-60 EDGE CONNECT MODELS PWR NC VALVE SENSE GROUND 24 VAC Power Alarm (normally closed contact) Valve Power (output) Remote Flame Sensor System Power PIN 1 PIN 3 PIN 4 PIN 5 PIN 6 Edge connect harness is available from Fenwal: Part Number: 05127324-0XX PROPER ELECTRODE LOCATION Proper location of the electrode assembly is important for optimum system performance. It is recommended that electrode assembly be mounted temporarily using clamps or other suitable means so that the system can be checked before permanently mounting the assembly. The electrode assembly should be located so that the tips are inside the flame envelope and about 1/2 inch (1 cm) above the base of the flame. See Figure 3 below. CAUTIONS: 1. Ceramic insulators should not be in or close to the flame. 2. Electrode assemblies should not be adjusted or disassembled. Electrodes should have a gap spacing of 0.125± 0.031 in (3.12± 0.81 mm). If this spacing is not correct, the assembly must be replaced. Electrodes are NOT field adjustable. 3. Exceeding the temperature limits can cause nuisance lockouts and premature electrode failure. Figure 3 TERMINAL DESIGNATIONS - QUICK CONNECT MODELS 24VAC/R 24 VAC Supply to Processor Thermostat Input PSW Pressure Switch Input GND V1 V2 L1 IND System Ground Valve Power (output) Valve Ground 120/240 VAC Input (hot) Inducer Blower (output) on 35-60 3/16 Quick Connect on 35-61 3/16 Quick Connect 3/16 Quick Connect CAUTIONS: 1. Ceramic insulators should not be in or close to the flame. 2. Electrode assemblies should not be adjusted or disassembled. Electrodes should have a gap spacing of 0.125± 0.031 in (3.12± 0.81 mm). If this spacing is not correct, the assembly must be replaced. Electrodes are NOT field adjustable. 3. Exceeding the temperature limits can cause nuisance lockouts and premature electrode failure. NC S1 FC+, FC- Alarm (normally closed contact) Remote Flame Sensor Flame Current Test Pins 3/16 Quick Connect WARNING: Operation outside specifications could result in failure of the Fenwal product and other equipment with injury to people and property. 35-60 and 35-61, 24 VAC DSI Control with or without Blower Relay Page 3

WIRING DIAGRAMS - 35-60 WIRING DIAGRAMS - 35-61 35-60 and 35-61, 24 VAC DSI Control with or without Blower Relay Page 4

TROUBLESHOOTING GUIDE NOTES 1. Dead SYMPTOM 2. Thermostat on but no spark or blower output 3. Blower on but no Trial-for-Ignition after purge delay 4. Valve on, no spark 5. Spark on, no valve 6. Flame ok during TFI, no flame sense after TFI RECOMMENDED ACTIONS A. Miswired B. Transformer bad C. Fuse/Circuit breaker bad D. Bad control (check LED for steady on) A. Miswired B. Bad thermostat. C. No voltage @ terminal D. Bad control (check LED for steady on) A. Miswired (check PSW terminal voltage) B. Flame sense problem (check LED-2 flashes) C. Pressure switch problem (check LED-1 flash) D. Bad control (check voltage between L1 & IND) A. Shorted electrode B. Open HV cable C. Bad control A. Valve coil open B. Open valve wire C. Bad control (check voltage between V1 & V2) A. Bad electrode B. Bad S1 or HV wire C. Poor ground at burner D. Poor flame (check flame current) FLAME SENSOR CURRENT CHECK Series 35-60, 35-61 Modules SERVICE CHECKS Flame current is the current which passes through the flame from the sensor to ground. The minimum flame current necessary to keep the system from lockout is.7 microamps. To measure flame current, connect a DC microammeter to the FC-FC+ terminals per figure. Meter should read.7 ua or higher. If the meter reads below 0 on scale, meter leads are reversed. Disconnect power and reconnect meter leads for proper polarity. 35-60 and 35-61, 24 VAC DSI Control with or without Blower Relay Page 5

DIMENSIONS - EDGE CONNECT MODELS Mating harness available from Fenwal: Part Number: 05127324-0XX DIMENSIONS - QUICK CONNECT MODELS FENWAL CONTROLS 400 MAIN STREET, ASHLAND, MA 01721 TEL: (508) 881-2000 FAX: (508) 881-6729 These instructions do not purport to cover all the details or variations in the equipment described, nor do they provide for every possible contingency to be met in connection with installation, operation and maintenance. All specifications subject to change without notice. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes, the matter should be referred to KIDDE-FENWAL, Inc., Ashland, Massachusetts. 2007 Fenwal Printed in U.S.A. TAG 35.60,61 7/13/07 Page 6 35-60 and 35-61, 24 VAC DSI Control with or without Blower Relay