User s manual ACS democase

Similar documents
ABB Drives. User s Manual HTL Encoder Interface FEN-31

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

ABB Drives. Protocol Manual - Modbus/TCP Ethernet Adapter Module FENA-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ACS800. Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program

ABB general machinery drives. User s manual ACS355 drives

ACS 800. Supplement Traverse Control Application Program 7.x

EFC Frequency converters

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

ACS800. Firmware Manual ACS800 Standard Control Program 7.x

ACS800. Firmware Manual ACS800 Standard Control Program 7.x

Waveguide Access Point WGA631. Product Guide

ABB machinery drives. User s manual ACS355 drives

ABB central inverters PVS to 1000 kw

NXL Series Inverters. HVAC Inverters made simple

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

ABB solar inverters. User s manual ABB Remote monitoring portal

MCR1900 Media Converter 19-Slot Chassis

NX Series Inverters. HVAC Pocket Programming Guide

Energy Communication Unit (ECU)

ABB general purpose drives. Firmware manual ACS580 standard control program

TMS TANK MANAGEMENT SYSTEM

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

Installation and start-up guide NETA-21 remote monitoring tool

4469 en / c. Ready. Run Start. Stop LCL RMT. Reset USB MODULE. Communications module. User Guide

Addendum to the Operating Instructions

How To Use The Vacon 0 Machinery

Energy Communication Unit (ECU)

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

Thyristor-controlled power supplies and battery chargers

HP Port Switches Quick Setup Guide

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

ELECTROMAGNETIC DISC BRAKES

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Low Voltage Products. Switches Automatic Transfer Switches

Low voltage AC drives. ABB industrial drives ACS800, single drives 0.55 to 5600 kw Catalog

ABB industrial drives. Application guide ACS800-01/U1/04/04LC/04M/U4/11/U11/14/31/U31/104/104LC Safe torque off function (+Q967)

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

ABB drives. User s manual ACS310 drives

Frequency Converter Fv

I STAR COMPUTER CO., LTD

Manual Ranging MultiMeter

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Online UPS. PowerWalker VFI 1000R/1U

ACS800 Hardware Manual ACS and ACS800-04M Drive Modules (45 to 560 kw) ACS800-U4 Drive Modules (60 to 600 HP)

Multi-Range Programmable DC Power Supplies 9115 Series

LIEBERT VNSA Installation Sheet

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Agilent 87421A/87422A Power Supply

LIFT CONTROL SYSTEMS CATALOGUE 2007

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Multi-Range Programmable DC Power Supplies 9115 Series

ACS800. Firmware Manual ACS800 Pump Control Application Program 7.2 (+N687)

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

ECOCIAT. Domestic hot water heat recovery unit

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

SCD Server. SCD Server Pro

PUMP DRIVES ENTRAÎNEMENTS DE POMPES PUMPENANTRIEBE MOTOR DE BOMBAS UNITÀ DI CONTROLLO POMPA OPERATING MANUAL: MODE D EMPLOI:

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

ABB high performance elevator drives. User s manual ACL30 elevator drive

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Wall-Mounting your HP computer. User Guide

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

ABB solar inverters. User s manual ABB Remote monitoring portal

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April SFC132089M0201 1

vacon compact ac drives creating perfect harmony

Advanced Central Monitoring. User Guide

dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Wireless Router Setup Manual

Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA

ABB solar inverters. Hardware manual PVS central inverters (100 to 1000 kw)

Telephone- and leased line modem for industrial applications TD-36

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Low Voltage Products

INSTALLATION INSTRUCTIONS

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

HP UPS R1500 Generation 3

HM-W536 Install Guide

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

OTM_F_C_. Installation instruction 34OTM_F_C_ / 1SCC303009M0201

Servo drives. Compact converter IndraDrive Cs

MANUAL PC1000R

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

1 Application Description Objective Goals... 3

LIFT CONTROL SYSTEMS CATALOGUE 2007

ABB industrial drives. Quick start-up guide Drive Manager for SIMATIC

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

QNAP RAID Expansion Enclosure Hardware User Manual QNAP Systems, Inc. All Rights Reserved.

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Transcription:

ABB industrial drives User s manual ACS880-01 democase Power and productivity for a better world

2 User s manual ACS88001 democase List of related manuals Drive hardware manuals and guides ACS880-01 hardware manual ACS880-01 quick installation guide for frames R1 to R3 ACS880-01 quick installation guide for frames R4 and R5 ACS880-01 quick installation guide for frames R6 to R9 Code (English) 3AUA0000078093 3AUA0000085966 3AUA0000099663 3AUA0000099689 Drive firmware manuals and guides ACS880 primary control program firmware manual ACS880 drives with primary control program, quick startup guide Code (English) 3AUA0000085967 3AUA0000098062 Option manuals and guides ACS-AP-I and ACS-AP-S assistant control panel user s manual Drive composer Start-up and maintenance PC tool User s manual Manuals and quick guides for I/O extension modules, fieldbus adapters, encoder interfaces, etc. Code (English) 3AUA0000085685 3AUA0000094606 You can find manuals and other product documents in PDF format on the Internet. Go to www.abb.com/drives and select Document Library. You can browse the library or enter selection criteria, for example a document code, in the search field. ABB industrial drives

User s manual ACS88001 democase 3 Safety instructions General safety instructions These safety instructions are intended for all personnel who work on the drive. For complete safety instructions, see the drive manuals. Ignoring these instructions can cause physical injury or death, or damage the equipment. All electrical installations and maintenance work on the drive should be carried out by qualified electricians only. WARNING! Make sure that the drive and all adjoining equipment are properly earthed. Do not attempt any maintenance on powered drive. After switching off the mains, always allow the intermediate circuit capacitors 5 minutes to discharge before doing any maintenance work on frequency converter, the motor or the motor cable. It is good practice to check (with a voltage indicating instrument) that the drive is in fact discharged before beginning work. WARNING! If the demo unit is operated within the transportation enclosure, please note that the motors and drives have less air available for cooling, which may result in overheating. Safety input connections The safety connections in the demo are made as in the picture below. Safety inputs 2, 3 and 4 are not in use by default. Note that if the IO-cable is not connected, it will automatically result in activation of the STO (safe torque off). IO-panel SI1 SI2 SI3 SI4 STO 1 & 2 IO-cable SI1- button (The red button on the lower left corner of the demo)

4 User s manual ACS88001 democase Delivery content ACS880-01 democase contains: (found in the pocket at the back of the demo) 1 1. IO-panel with removable control panel 2. USB to Mini USB cable for PC-connection 3. Ethernet cable for IO-panel connection 4. Quick installation guide ACS880-01 frames R1 to R3 5. Mains cord 6. Manual CD 7. FENA-01/-11 Ethernet adapter module manual 8. FEN-31 HTL encoder interface quick guide 9. Quick start-up guide for primary control program 2 3 4 5 6 9 7 8

User s manual ACS88001 democase 5 Basic start-up 1. Lay the democase on its back (so that the door is pointing up) and open the door. 2. Pull the demo out of the case using the lifting strap and the handle hole (on the lower part of the demo.) Warning! The demo weighs approximately 25kg. Use of proper lifting technique with a straight back is advised. 3. Take out the mains cord and Ethernet cable from the pocket at the back of the demo. 4. Plug in the mains cord and Ethernet cable (to connections marked: mains cord, IO-panel connection A and IO-panel connection B on the layout section.) 5. Check that the Input voltage switch (115V/230V) is set according to the supply voltage.* 6. Check that the Drive Main Supply is switched on. 7. Switch on the demo using the mains switch. 8. You can toggle control between the control panel and the IO-panel with the Loc/Rem button on the control panel. * For more information check AC input (supply) connection in the Technical data section Mechanical brake The mechanical brake is intended for momentary impulse braking for load demonstration purposes. The mechanical brake is not designed for continuous load which might damage the transformer and the brake itself.

6 User s manual ACS88001 democase Layout Lifting strap IO-panel Control panel USB connection IO-panel connection A Mechanical brake Input voltage switch (115V/230V) Mains switch Fuse terminal Safety input 1 (default: STO) D2D connection Mains cord connection External ZCU supply switch Drive main supply switch 24V out External power LAN connection IO-panel connection B

User s manual ACS88001 democase 7 Default IO button functions (0= LED off, 1= LED on) AI1: Speed reference AO1: Motor speed AI2: Not in use AO2: Motor current DI1: Stop (0), Start (1) DI2: Forward (0), Reverse (1) DI3: Reset DI4: Ramp selection DI5: Constant speed 1 Off (0), On (1) DI6: Not in use DIIL: Not in use RO1: Ready (1) RO2: Running (1) RO3: Faulted (-1) DIO1: Output: Ready (1) mode: Input (0), Output (1) DIO2: Output: Running (1) mode: Input (0), Output (1) SI1: Safe torque off (1) SI2, SI3 & SI4: Not in use

8 User s manual ACS88001 democase Parameters that need to be changed Parameter Name Setting Notes 95 HW configuration 95.01 Supply voltage [2] 380 415 V Correct rating settings made 91 Encoder module settings 91.11 Module 1 type [4] FEN-31 91.12 Module 1 location 003 FEN-31 location in Option slot 3 92 Encoder 1 configuration 92.01 Encoder 1 type [5] HTL 92.02 Encoder 1 source [1] Module 1 92.10 Pulses/revolution 1024 92.12 Speed calculation mode [0] A&B all 92.13 Position estimation enable [0] Disable 92.15 Transient filter [2] 1220 Hz 92.20 Enc cable fault func [0] No After setting feedback parameters, activate settings with 91 Encoder 1 configuration 91.10 Encoder parameter refresh [1] Configure Will return to 'Done'after refresh 90 Feedback selection 90.41 Motor feedback selection [1] Encoder 1 I/O settings 12 Standard AI 12.25 AI2 unit selection [2] V 12.28 AI2 max 10 Motor parameters and ID-run 99 Motor data 99.03 Motor type [0] Asynchronous motor 99.04 Motor ctrl mode [0] DTC 99.06 Motor nominal current 1.2 A 99.07 Motor nominal voltage 230 V 99.08 Motor nominal frequency 50 Hz 99.09 Motor nominal speed 1360 rpm 99.10 Motor nominal power 0.18 kw 99.11 Motor nominal cosfii 0.71 99.13 Identification run request [1] Normal Start ID-run in 'Remote': Press DI1, in 'Local': Press panel Start button

User s manual ACS88001 democase 9 Supply switches The democase supply can be controlled with the switches External ZCU supply switch and Drive main supply switch. The two switches work separately. The External ZCU supply switch controls the external 24V supply to the control unit of the drive and the Drive main supply switch controls the 400V main supply to the drive. For information about the internal connections refer to section: Technical data. Change of fuse WARNING! Turn off the democase and disconnect the power cord before changing the fuse. Replace the fuse with the same type of fuse. Changing the fuse does not require any tools. Open the fuse terminal by pressing together the pins on the top and bottom of the fuse terminal and pulling the terminal out. Pull out the old fuses and replace them with new fuses of the same type. Push the fuse terminal back in. Correct fuse type is: T2AL250V (Slow, 2.0A, 250V glass tube fuse) There are two fuses of this type in the fuse terminal.

10 User s manual ACS88001 democase Technical data Dimensions Height: Width: Depth: Weight: 650 mm 980 mm (trolley handle pulled up) 490 mm 385 mm 30 kg Drive type code ACS880-01-02A4-3+K473+L502 (K473 = FENA-11, L502 = FEN-31) Motor details ABB M2VA 63 B 4 (3GVA 062 142-ASC) Parameter ACS880-01 parameter Value Motor type 99.03 Motor type AM Rated current In 99.06 Motor nominal current 1.2 A Rated voltage Un 99.07 Motor nominal voltage 230.0 V Frequency Fn 99.08 Motor nominal frequency 50.0 Hz Rated speed 99.09 Motor nominal speed 1360 rpm Rated power Pn 99.10 Motor nominal power 0.18 kw COS 99.11 Motor nominal cosfii 0.71 Rated torque 99.12 Motor nominal torque 0.82 Nm AC input (supply) connection U1 ~ 100V - 240V The democase can be used with both 115V and 230V supply. It is important to check that the input voltage switch (115V/230V) is in the correct position for the supply. I.e. if you are using 230V supply, then 230V should be visible in the switch. If the switch is set incorrectly you will burn the fuse. Degree of protection Drive: IP21 Motor: IP55

User s manual ACS88001 democase 11 Ambient conditions The demo is designed for demonstration purposes and for indoor use only. Ambient temperature: - Transport: -40 to +70 C - Storage: -40 to +70 C - Operation: -15 to +40 C, no frost allowed Altitude: - 0 to 4,000 m without an effect on demo operation Relative humidity: - 5 to 95%, no condensation allowed For more detailed information, refer to the drive Hardware Manual. Internal connections M2VA 63 B 4 motor ACS880-01 drive Input voltage switch (115V/230V) 24V Drive Main Supply switch 230V 400V 115V Mains switch Ext ZCU Supply switch

12 User s manual ACS88001 democase Further information Product and service inquiries Address any inquiries about the product to your local ABB representative, quoting the type designation and serial number of the unit in question. A listing of ABB sales, support and service contacts can be found by navigating to www.abb.com/drives and selecting Sales, Support and Service network. Product training For information on ABB product training, navigate to www.abb.com/drives and select Training courses. Providing feedback on ABB Drives manuals Your comments on our manuals are welcome. Go to www.abb.com/drives and select Document Library Manuals feedback form (LV AC Drives).

This page is intentionally left blank. User s manual ACS88001 democase 13

14 User s manual ACS88001 democase This page is intentionally left blank.

This page is intentionally left blank. User s manual ACS88001 democase 15

16 User s manual ACS88001 democase Contact us ABB Oy ABB Inc. ABB Beijing Drive Systems Co. Ltd. Drives Drives & Motors No. 1, Block D, A-10 Jiuxianqiao Beilu P.O. Box 184 16250 West Glendale Drive Chaoyang District FI-00381 HELSINKI New Berlin, WI 53151 Beijing, P.R. China, 100015 FINLAND USA Telephone +86 10 5821 7788 Telephone +358 10 22 11 Telephone 262 785-3200 Fax +86 10 5821 7618 Fax +358 10 22 22681 1-800-HELP-365 www.abb.com/drives www.abb.com/drives Fax 262 780-5135 Automation Technologies www.abb.com/drives 3AUA0000127806 Rev A (EN) EFFECTIVE: 2012-11-02 Power and productivity for a better world