Hardy Frame Shearwall System Installation Guide

Similar documents
POST AND FRAME STRUCTURES (Pole Barns)

Residential Deck Safety, Construction, and Repair

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

Narrow Wall Bracing. Prescriptive Method Hardy Frame

STANDARD OPEN PATIO COVER

Superform Products Ltd.

TYPICAL PATIO COVERS 111

ICC-ES Evaluation Report

Guidelines for Earthquake Bracing of Residential Water Heaters

Page & Turnbull imagining change in historic environments through design, research, and technology

How to secure your property after a disaster

Connection Solutions

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

COMMONLY USED RESIDENTIAL BUILDING CODES

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

609 West Rock Road, Radford,VA / (fax) RECOMMENDED ATTACHMENTS & CONNECTION DETAILS

Best Barns USA Assembly Book

Mark Cramer Inspection Services, Inc.

Chapter 3 Pre-Installation, Foundations and Piers

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

Ceiling Mounted Folding Attic Ladders Installation Instructions

Featuring TJ Rim Board and TimberStrand LSL

Guidelines for Earthquake Bracing Residential Water Heaters

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

Technical Assignment 2 TABLE OF CONTENTS

6 RETROFITTING POST & PIER HOUSES

Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor

Chapter 6 ROOF-CEILING SYSTEMS

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

Seismic Technical Guide

PART 1 GENERAL 1.1 SECTION INCLUDES

PANELIZED HOME INSTALLATION GUIDELINE

Residential Decks. Planning and Development Services Department

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

UNIVERSAL ASSEMBLY INSTRUCTIONS FOR VERSATUBE BUILDINGS CONTRACTOR SERIES 2 X 4 FRAMES

Introduction...COMB-2 Design Considerations and Examples...COMB-3

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

Hunter College school of Social Work Thesis Proposal

Formwork for Concrete

Chapter 10 - Scaffolding Systems

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE

Hilti, Inc South 122 nd East Avenue Tulsa, OK

EAST LYME HIGH SCHOOL

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

USP SIP Connection Manual

Chapter. Restoration of Damaged Structures

CPA Steel Stud Framing Page 1 of 11

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

March 14, Installation of Bay, Bow and Garden Windows

Uncovered Decks & Porches

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Policy on Water Heater Installations Policy No. UPC Effective: September 1, 1995 Revised: February 10, 1996

3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

DE Frame with C Series Sidelight

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Detailing of Reinforcment in Concrete Structures

Wisconsin Building Products Evaluation

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Seismic Installation for Attic Storage System

Section A Roof Truss

SECTION STORM DRAINAGE SYSTEM

Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings

Protecting Your Home From Hurricane Wind Damage

USP SIP Connection Manual

[TECHNICAL REPORT I:]

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

CALCULATION & DRAFTING STANDARDS MANUAL PROCEDURE: C&D 515 Bill of Materials Standard REV 0.0 5/6/04

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Owner's Manual & Assembly Instructions

What is Seismic Retrofitting?

CHAPTER 6 CONSTRUCTION TYPES

Discipline: Structural Issued

INSTALLATION OF A BAY WINDOW

Residential Foundations and Basements

HORIZONTAL INSTALLATION

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

Assembly Instructions

This digital document created and presented by Richard Fleetwood. He is the. Civil Defense Now! ( websites.

Submittal Information

Typical Deck Details

Installation Instructions: (Part # SB76880) XRC Armor Front Fender Kit

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

Dock Hardware & Accessory Products Catalog

Standard from CSI Part Section Format For Wood Framing For Metal Framing For Gypsum Sheathing

TJi 110 TJi 210 TJi 230 TJi 360 TJi. 560 JoiSTS. NEW! now featuring 18" and 20" TJi joists

Repair of Earthquake-Damaged Masonry Fireplace Chimneys SOUTH NAPA EARTHQUAKE RECOVERY ADVISORY

Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

8/18/14. Introduction to. Framing. Terminology and Concepts

Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the A325 structural bolt. Rev.

Chapter 3 FOUNDATIONS AND FOUNDATION WALLS

Transcription:

Hardy Frame Shearwall System Installation Guide Easy as 1, 2, 3 1. Embed Anchors Select Template Kit based on product width and anchor grade STD=ASTM F1554 GR 3 HS=ASTM A193 GR B7 2. Bottom Connection S E R I E S Place Panel or Brace Frame on anchors Secure with Hardened Round Washers and Grade 8 Hex Nuts 3. Top Connection Connect to top plates with 1/4" diameter screws HARDY FRAME PANEL AT TOP PLATES See inside for other installations including fillers, garage portals and beams 789 S. Victoria Ave., Suite 200 Ventura, California 93003 800 754-3030 www.hardyframe.com IG 1/11

PRODUCTS 1 Panel Balloon Panel Hardy Frame Product Listing HFX-Series Depth Width Height Weight (lbs) HFX/S-Series Height Weight (lbs) HFX-9x79.5 79-1/2" 81 NA 9" HFX-9X8 93-3/4" 95 HFX/S-9x8 9 5/8" 98 HFX-12x78 78" 91 NA HFX-12x8 92-1/4" 10 HFX/S-12x8 9-5/8" 111 12" HFX-12x9 104-1/4" 11 HFX/S-12x9 108-5/8" 121 HFX-12x10 11-1/4" 128 HFX/S-12x10 120-5/8" 133 HFX-18x78 78" 113 NA HFX-18x8 92-1/4" 131 HFX/S-18x8 9-5/8" 137 HFX-18x9 104-1/4" 144 HFX/S-18x9 108-5/8" 150 HFX-18x10 18" 11-1/4" 158 HFX/S-18x10 120-5/8" 14 3-1/2" HFX-18x11 128-1/4" 177 HFX/S-18x11 132-5/8" 183 HFX-18x12 140-1/4" 190 HFX/S-18x12 144-5/8" 19 HFX-18x13 152-1/4" 203 HFX/S-18x13 15-5/8" 209 HFX-24x78 78" 148 NA HFX-24x8 92-1/4" 172 HFX/S-24x8 9-5/8" 180 HFX-24x9 104-1/4" 190 HFX/S-24x9 108-5/8" 198 HFX-24x10 24" 11-1/4" 209 HFX/S-24x10 120-5/8" 217 HFX-24x11 128-1/4" 233 HFX/S-24x11 132-5/8" 241 HFX-24x12 140-1/4" 251 HFX/S-24x12 144-5/8" 259 HFX-24x13 152-1/4" 29 HFX/S-24x13 15-5/8" 277 HFX-32x8 92-1/4" 138 HFX/S-32x8 9-5/8" 145 HFX-32x9 104-1/4" 13 HFX/S-32x9 108-5/8" 170 HFX-32x10 11-1/4" 188 HFX/S-32x10 120-5/8" 195 32" HFX-32x11 128-1/4" 213 HFX/S-32x11 132-5/8" 220 HFX-32x12 140-1/4" 238 HFX/S-32x12 144-5/8" 245 HFX-32x13 152-1/4" 23 HFX/S-32x13 15-5/8" 271 3-1/2" HFX-44x8 92-1/4" 15 HFX/S-44x8 9-5/8" 13 HFX-44x9 104-1/4" 181 HFX/S-44x9 108-5/8" 189 HFX-44x10 11-1/4" 20 HFX/S-44x10 120-5/8" 214 44" HFX-44x11 128-1/4" 231 HFX/S-44x11 132-5/8" 239 HFX-44x12 140-1/4" 25 HFX/S-44x12 144-5/8" 24 HFX-44x13 152-1/4" 281 HFX/S-44x13 15-5/8" 289 HFX-18x14 Hardy Frame Balloon Wall Application 14-1/4" 221 HFX-18x15 17-1/4" 237 HFX-18x1 188-1/4" 250 HFX-18x17 18" 200-1/4" 24 HFX-18x18 212-1/4" 283 HFX-18x19 224-1/4" 29 HFX-18x20 23-1/4" 309 3-1/2" HFX-24x14 14-1/4" 290 HFX-24x15 17-1/4" 311 HFX-24x1 188-1/4" 329 HFX-24x17 24" 200-1/4" 348 HFX-24x18 212-1/4" 372 HFX-24x19 224-1/4" 390 HFX-24x20 23-1/4" 408

PRODUCTS Post Hardy Frame Product Listing HFP-Series Depth Width Height Weight (lbs) HFX/S-Series Height Weight (lbs) HFP8-7/8 92-1/4" 42 HFP/S8-7/8 9-5/8" 44 HFP8-1 1/8 92-1/4" 42 HFP/S8-1 1/8 9-5/8" 44 HFP9-7/8 104-1/4" 47 HFP/S9-7/8 108-5/8" 49 HFP9-1 1/8 104-1/4" 47 HFP/S9-1 1/8 108-5/8" 49 HFP10-7/8 11-1/4" 52 HFP/S10-7/8 120-5/8" 54 HFP10-1 1/8 3-1/2" 3-1/2" 11-1/4" 52 HFP/S10-1 1/8 120-5/8" 54 HFP11-7/8 128-1/4" 57 HFP/S11-7/8 132-5/8" 59 HFP11-1 1/8 128-1/4" 57 HFP/S11-1 1/8 132-5/8" 59 HFP12-7/8 140-1/4" 2 HFP/S12-7/8 144-5/8" 4 HFP12-1 1/8 140-1/4" 2 HFP/S12-1 1/8 144-5/8" 4 HFP13-7/8 152-1/4" 7 HFP/S13-7/8 15-5/8" 9 HFP13-1 1/8 152-1/4" 7 HFP/S13-1 1/8 15-5/8" 9 Hardy Frame Accessories Single Use Templates Weight (lbs) Face to Face Templates Weight (lbs) CMU Templates Weight (lbs) HFXT9 0.8 HFXDT9 2.0 HFXT-CMU9 0.8 HFXT12 0.9 HFXDT12 2.2 HFXT-CMU12 1.0 HFXT18 1.1 HFXDT18 2.8 HFXT-CMU18 1.4 HFXT24 1.7 HFXDT24 3.8 HFXT-CMU24 1.9 HFXT32 3.2 HFXDT32 5.1 HFXT-CMU32 2. HFXT44 4.2 HFXDT44.4 HFXT-CMU44 3.3 STD Template Kits Weight (lbs) HS Template Kits Weight (lbs) Bolt Brace Weight (lbs) HFXTK9 19.8 HFXTK-HS12 25.0 HFXBB9 0.3 HFXTK12 20.0 HFXTK-HS18 2.0 HFXBB12 0.4 HFXTK18 20.5 HFXTK-HS24 2.5 HFXBB18 0. HFXTK24 21.5 HFXTK-HS32 18.0 HFXBB24 0.8 HFXTK32 1.0 HFXTK-HS44 19.0 HFXTK44 17.5 STD Tension Connector Kits Weight (lbs) HS Tension Connector Kits Weight (lbs) Bearing Plates Weight (lbs) HFTC-7/8 STD 14.5 HFTC-7/8 HS 15.5 HFXBP12 (Length = 18") 13 HFTC-12 STD 17.5 HFTC-12 HS 18.5 HFXBP18 (Length = 24") 17 HFTC-18/24 STD 20.0 HFTC-18/24 HS 21.0 HFXBP24 (Length = 30") 21 Base Extension Weight (lbs) Reducer Weight (lbs) Bolt Lever Weight (lbs) HFBX 2 HFR 0.2 HFBL 21 Saddles Weight (lbs) Deep Socket Weight (lbs) Stacking Washers Weight (lbs) HFS24 3 HFDS 7/8 2 HFSW12 1 HFS3 4 HFDS-1 1/8 3 HFSW18/24 2 Notes 1) For Panels, adding STK after the model number indicates HFX-Series Stacking Panels with built-in Plate Washers at the top channel. 2) Custom heights are available for Panels s and Posts not to exceed the maximum height listed for that product. 3) Model number HFX-9x79.5, HFX-12x78, HFX-18x78 and HFX-24x78 Panels come with two straps welded to the solid face. 4) All Panels, s and Posts are a 3-1/2 depth. Refer to Attachment page for a description of installation in 2x and greater wall depths. 2

TM ANCHORAGE NOTE: HFX HOLD DOWN CENTER LINES ARE NOT THE SAME AS ORIGINAL SERIES PRODUCTS 10 INCH MAXIMUM OR PER PLANS 3 MIN. 10 INCH MAXIMUM OR PER PLANS VARIES WITH PANEL/BRACE FRAME WIDTH CURB ELEVATION BOLT BRACE SEE TABLE NOTE 7 P0P-OUT PER PLAN 10-INCH MAXIMUM OR PER PLAN 3" MIN C a2 C a2 CURB SECTION OTHER SECTION VIEWS SIMILAR 3 L t 4 MIN # 3 REBAR, GRADE 0 (MIN) TIE FIELD TIE TABLE FOR OVERLAP HOLD DOWN ANCHOR SHEAR TIE REINFORCEMENT H.D. # 3 REBAR TIE SEE TABLE FOR REQUIRED QUANTITY 3 MIN. 5 1/2" HFX-9 8 1/2" HFX-12 EXTERIOR SLAB ELEVATION 12 3/4" HFX-18 18 3/4" HFX-24 3 MIN. 20 1/2" HFX-32 SHEAR TIE @ CURB INTERIOR SLAB ELEVATION 31" HFX-44 GROUT FILLED CMU OR CONCRETE (PER PLAN) PER PLAN ANCHORAGE NOMENCLATURE 1 1/8-STD-14-20 C a 1 C a 2 l e ROD GRADE ROD DIAMETER = Length of Embed into Footing C a2 = Edge, End Distance ANCHORAGE NOMENCLATURE 1-1/8-HS-20-30 C a 1 C a 2 l e ROD GRADE ROD DIAMETER = Length of Embed into Footing C a2 = Edge, End Distance 3 MIN. FOOTING DEPTH AND WIDTH MAY DECREASE BEYOND DIMENSION STEM WALL ELEVATION NOTE: COUPLING NUTS MAY BE USED TO EXTEND ALL THREAD ROD LENGTH THROUGH GROUT FILLED CMU OR CONCRETE Product Width (in) Max Height (ft) Anchorage 1 (See Nomenclature for Description) 4, 5, Shear Tie Quantity Tie Length (in) STD ROD 2 HS ROD 3 STD ROD HS ROD 9 8 1 1/8-STD-10-15 NA NA 7 1/2 12 10 1 1/8-HS-14-20 1 10 1/2 1 1/8-STD-14-20 13 1 1/8-HS-20-30 1 18 15 20 NA 1 1/8-HS-13-20 NA 13 1 1/8-STD-14-20 1 1/8-HS-20-30 1 24 2 21 20 NA 1 1/8-HS-18-27 NA 32 13 1 22 1/2 7/8-STD-11-1 7/8-HS-13-20 1 44 13 2 33 3 1) Applies to 2500 psi compressive strength concrete, both seismic and wind loading 2) STD indicates rods complying with ASTM F1554 Grade 3 with a Hardy Frame Bolt Brace (HFXBB) double nutted on the embed end. 3) HS indicates rods complying with ASTM A 193 Grade B7 (or equal) with a1/2x3x3 plate washer double nutted on the embed end. HFXBB is recommended. 4) Concrete edge distance must comply with ACI318-05 D8.2. 5) Installations on curbs or stemwalls must be inch width minimum, and may require supplemental shear reinforcement per ACI-318-05, fc = 2500 psi ) Shear Ties are not required for installations away from the Foundation Edge, for installations on wood framing or for Braced Wall Panel applications. 7) Bolt Brace is used for bolt alignment. When used with STD grade rods plate washers are not required. When used with HS grade rods plate washers are still required. 8) Foundation Design is by others 9) The Building Design Professional is permitted to modify these details to accommodate a specific condition.

TM TEMPLATE KITS Hardy Frame HFX-Series Template (HFXT) Grade 8 Hex Nut Hardened Round Washers ALT: two SAE Washers ALT: two Flat-Round Washers Hold Down Anchor STD = ASTM F1554 Grade 3 HS = ASTM A193 Grade B7 Hardy Frame Bolt Brace (HFXBB) 1/2 x 3 x 3 Plate Washer - not required for STD specification Standard Grade Hex Nut minimum HFXBB - Bolt Brace Hardy Frame HFX-Series Template Kit (HFXTK) Panel Kit at Slab Panel Kit at Curb Kit at Interior Footing Hardy Frame Bolt Brace Hardy Frame HFX-Series Template Kit Components Panels s Kit Model Number Template (1 ea) Bolt Brace (1 ea) Hold Down Anchor Assembly 1-1/8 STD 1-1/8 HS 7/8 STD 7/8 HS HFXTK9 HFXT9 HFXBB9 2 HFXTK12 HFXT12 HFXBB12 2 HFXTK-HS12 HFXT12 HFXBB12 2 HFXTK18 HFXT18 HFXBB18 2 HFXTK-HS18 HFXT18 HFXBB18 2 HFXTK24 HFXT24 HFXBB24 2 HFXTK-HS24 HFXT24 HFXBB24 2 HFXTK32 HFXT32 NA 2 HFXTK-HS32 HFXT32 NA 2 HFXTK44 HFXT44 NA 2 HFXTK-HS44 HFXT44 NA 2 Hold Down Anchor Assemblies: 1-1/8 STD = 1-1/8 x 32" ASTM F1554 Grade-3 all thread with(1)-hardened Round Washer & (3) Grade 8 Hex Nuts. 1-1/8 HS = 1-1/8 x 38" ASTM A193 Grade-B7 all thread with (1) Hardened Round Washer, (1) 1/2x3x3 ASTM A3 Plate Washer & (3) Grade-8 Hex Nuts 7/8 STD = 7/8 x 30" ASTM F1554 Grade-3 all thread with(1)-hardened Round Washer & (3) Grade 8 Hex Nuts. 7/8 HS = 7/8 x 31" ASTM A193 Grade-B7 all thread with (1) Hardened Round Washer, (1) 1/2x3x3 ASTM A3 Plate Washer & (3) Grade-8 Hex Nuts 1) All Thread length = length of embed (le) + 12 (formboard) + (Kit assembly + height above concrete) For Raised Floor installations adjust the all thread length or extend length with a Grade 8 Coupling nut 2) The Hardened Round Washers for connecting the Panel base may be substituted with two SAE or two Round-Flat Washers 3) STD assemblies require a Hardy Frame Bolt Brace (Minimum) double nutted at the embed end 4) HS assemblies require 1/2x3x3 ASTM A3 Plate Washer (Minimum) and the Hardy Frame Bolt Brace is recommended 5) HS all thread rods provided by Hardy Frames, Inc. are stamped on both ends HF B7 4

PANEL INSTALLATIONS TM 2-3/4 Hardy FramePANEL PanelBOTTOM HARDY FRAME on concrete ON CONCRETE Base Extension HFBX attachment for adjacent framing Bearing Plate HFXBP Install below Panel directly on Rim. Requires 3" end distance (Panels only) 4-1/4 Hardy Frame Panel at raised floor head out Hardy FramePANEL PanelBOTTOM Hardy Frame Panel HARDY FRAME HARDY FRAME PANEL BOTTOM on and washers (RequiresON MUD SILL on wood sill ONnuts DOUBLE NUT 5,000 psi non-shrink grout) HARDY FRAME PANEL BOTTOM ON RAISED FLOOR ON CONCRETE Hardy Frame Panel on raised floor 1/4 x 4 1/2" screws Hardy Frame Panel Hardy Frame Panel Hardy Frame Panel straight stack installation. stagger-stack installation. to two Hardy Frame Note: Stacking Washers Note: Stacking Washers Posts below HARDY FRAME PANEL BOTTOM HARDY FRAME PANEL HARDY FRAME in PANEL BOTTOM are required the top are required in thebottom top HARDY FRAME PANEL BOTTOM 2 POSTS STAGGER STACK ONchannel MULTI STORY of lower Panel. channel of lower Panel. ON RAISED FLOOR Hardy Frame Panel Hardy Frame Panel Hardy Frame Panel at top plates with 2x filler at Portal 1/4 x 3"screws (straps may be 1/4 xpanel 3" screws HARDY FRAME AT TOP PLATES 1/4 x 4PANEL 1/2" screws HARDY FRAME WITH 2X FILLER required by design professional) HARDY FRAME include PANEL welded AT PORTAL Note: 78" heights straps Floor to Floor connectors Hardy Frame Tension Connector Kit Componentsnts Panels HFTC Tension Kit Model Number STK Stacking Washer Connector Rod Assembly 1-1/8 STD 1-1/8 HS 5 HFTC12- STD 2-HFSW12 HFTC12- HS 2-HFSW12 HFTC18/24 STD 2-HFSW18/24 HFTC18/24 HS 2-HFSW18/24 2 2 2 2 Hardy Frame Panel with 4x filler 1/4 x 3" screws (custom heights available) HARDY FRAME PANEL WITH 4X FILLER Connector Rod Assemblies: HFTC-1 1/8 STD = 1-1/8 x 2" ASTM F1554 Grade-3 all thread with (2) Hardened Round Washers & (2) Grade 8 Hex Nuts. HFTC-1 1/8 HS = 1-1/8 x 2" ASTM A193 Grade-B7 all thread with (2) Hardened Round Washers & (2) Grade 8 Hex Nuts. 1) Hardy Frame STK washers are required in the top channel of Panels when connnecting to a hold down rod from above. 2) All Thread length fits up to a 14 joist depth + 3/4" subfloor + (4) 2x wood plates 3) Each Hardened Round Washer may be substituted with two SAE or two Round-Flat Washers 4) HS all thread rods provided by Hardy Frames, Inc. are stamped on both ends HF B7 Refer to the Hardy Frame Catalog and Installation Details for more specific information

TM PANEL & CONNECTOR INFORMATION Model Number Net Height (in Hardy Frame HFX-Series Panel - Dimensions & Connectors Width (in) Depth (in Anchorage Call-Out - STD Rods 1 Dia-Grade-le-Ca 1,2 Anchorage Call-Out - HS Rods 1 Dia-Grade-le-Ca 1,2 Top Screw Qty 2,3 (ea) Bottom Screw Qty 2,4 (ea) Edge Screw QTY Available 5 (ea) HFX-9x79.5 79 1/2 HFX-9x8 93 3/4 9 3-1/2 1 1/8-STD-10-15 NA 5 NA 4 HFX-12x78 78 7 HFX-12x8 92 1/4 4 12 3-1/2 1 1/8-STD-14-20 1 1/8-HS-14-20 HFX-12x9 104 1/4 HFX-12x10 11 1/4 5 HFX-18x78 78 HFX-18x8 92 1/4 4 HFX-18x9 104 1/4 HFX-18x10 11 1/4 1 1/8-STD-14-20 1 1/8-HS-20-30 10 HFX-18x11 128 1/4 5 HFX-18x12 140 1/4 HFX-18x13 152 1/4 18 3-1/2 10 HFX-18x14 14 1/4 HFX-18x15 17 1/4 HFX-18x1 188 1/4 HFX-18x17 200 1/4 NA 1 1/8-HS-13-20 NA HFX-18x18 212 1/4 7 HFX-18x19 224 1/4 HFX-18x20 23 1/4 8 HFX-24x78 78 18 1 HFX-24x8 92 1/4 15 4 HFX-24x9 104 1/4 HFX-24x10 11 1/4 1 1/8-STD-14-20 1 1/8-HS-20-30 HFX-24x11 128 1/4 14 5 HFX-24x12 140 1/4 HFX-24x13 152 1/4 24 3-1/2 HFX-24x14 14 1/4 14 HFX-24x15 17 1/4 HFX-24x1 188 1/4 HFX-24x17 200 1/4 NA 1 1/8-HS-18-27 NA HFX-24x18 212 1/4 7 HFX-24x19 224 1/4 HFX-24x20 23 1/4 8 Panel Balloon Panel (14'- 20 Heights) Notes 1) STD Hold Down rods must comply with ASTM F 1554 Grade 3. HS Hold Down rods must comply with a high strength steel specification, High Strength rods include but are not limited to ASTM F 1554 Grade 105, ASTM A 193 Grade B7 and ASTM A 354 Grade BD. ANCHORAGE NOMENCLATURE PANEL NOMENCLATURE 2) Screws are 1/4-inch diameter USP-WS Series (ESR-271) or equal with a 1 1/8-STD-14-20 HFX-18 x 9 minimum allowable design value of 311 lbs. (excluding any duration of load C a 1, 2 stress increase) based on connecting metal (No. 12 gage) to wood (specific l e gravity of 0.50 or greater). ROD GRADE ROD DIAMETER 3) Top screw length is 3-inches when attaching directly to the collector. When installing a 2-by wood filler (specific gravity of 0.5 or greater) at the top connection, the minimum screw length is 4-1/2 inches. STACKING PANEL NOMENCLATURE HFX-18 x 9 - STK 4) Bottom screw length is 4-1/2 inches at Panel and connections, STACKING 3-inches at Hardy Frame Bearing Plate. NOMINAL HEIGHT 5) 1/4 diameter screws are required at Balloon Panels, when installing fillers ACTUAL WIDTH above greater than 1-1/2" or when specified by the Building Design Professional. PRODUCT SERIES 9 inch wide Panels are intended for installation directly on concrete. Heights are 1-1/2" greater than all other HFX-Series Panels. NOMINAL HEIGHT ACTUAL WIDTH PRODUCT SERIES NOTE: Model number followed by STK indicates Stacking Panel with built-in plate washers at top.

TM BRACE FRAME INSTALLATIONS Hardy Frame on concrete Hardy Frame at raised floor head out Hardy Frame on nuts and washers (Requires 5,000 psi non-shrink grout) BOTTOM ON DOUBLE NUT Hardy Frame on wood sill BOTTOM ON MUD SILL Hardy Frame Hardy Frame on raised floor 1/4 x 4 1/2" screws straight HARDY FRAME stack BRACE installation FRAME BOTTOM ON MULTI STORY (check cumulative forces) BOTTOM ON RAISED FLOOR Hardy Frame stagger-stack installation BOTTOM STAGGER Hardy Frame to two Hardy Frame BOTTOM 2 POSTS Posts below Hardy Frame TOP WITH TOP PLATE at top plates 1 1/4 x 3" screws Hardy Frame TOP WITH FILLER with 2x filler 1/4 x 4 1/2" screws Hardy Frame 4X FILLER with 4x filler 1/4 x 3" screws (custom heights available) Hardy Frame at Portal 1/4 x 3" screws. Straps may be required. 7 Floor to Floor connectors HFTC Hardy Frame Tension Connector Kit Componentsnts Tension Kit Model Number STK Stacking Washer HFTC-7/8 STD NA 2 s Connector Rod Assembly 7/8 STD 7/8 HS HFTC-7/8 HS NA 2 Connector Rod Assemblies: Refer to the Hardy Frame Catalog and Installation Details for more specific information HFTC-7/8 STD = 7/8 x 2" ASTM F1554 Grade-3 all thread with (2) Hardened Round Washers & (2) Grade 8 Hex Nuts. HFTC-7/8 HS = 7/8 x 2" ASTM A193 Grade-B7 all thread with (2) Hardened Round Washers & (2) Grade 8 Hex Nuts 1) Plate washers are built into all four corners of Brace Frames. STK washers are not required. 2) All Thread length fits up to a 14" joist depth + 3/4" subfloor + (4) 2x wood plates 3) Each Hardened Round Washer may be substituted with two SAE or two Round-Flat Washers 4) HS all thread rods provided by Hardy Frames, Inc. are stamped on both ends HF B7

TM BRACE FRAME CONNECTOR INFORMATION Hardy Frame HFX-Series Dimensions and Connectors Model Number Net Height (in) Width (in) Depth (in) Anchorage STD Anchorage HS Top Screw Qty (ea) Bottom Screw Qty (ea) HFX-32x8 92-1/4" HFX-32x9 104-1/4" HFX-32x10 11-1/4" HFX-32x11 128-1/4" 32 3-1/2" 7/8-STD-11-1 7/8-HS-13-20 14 14 HFX-32x12 140-1/4" HFX-32x13 152-1/4" HFX-44x8 92-1/4" 17 HFX-44x9 104-1/4" 15 HFX-44x10 11-1/4" 44 3-1/2" 7/8-STD-11-1 7/8-HS-13-20 14 HFX-44x11 128-1/4" 14 HFX-44x12 140-1/4" HFX-44x13 152-1/4" 1) For top and bottom shear connections use 1/4 inch diameter USP WS-Series, SDS-Series or equivalent screws. BRACE FRAME NOMENCLATURE HFX-32 x 9 NOMINAL HEIGHT ACTUAL WIDTH PRODUCT SERIES ANCHORAGE NOMENCLATURE 7/8 - STD -11-1 C a 1, 2 l e ROD GRADE ROD DIAMETER HFX Series 32" Bolt Pattern TOP & BOTTOM 5 3/4" 20 1/2" 5 3/4" 32" 32" Hardy Frame HFX-Series TOP & BOTTOM HFX Series 44" Bolt Pattern 1/2" 31" 1/2" 44" 44" Hardy Frame HFX-Series Model Number Hardy Frame HFP-Series Post Net Height (in) Width (in) Depth (in) Hold Down Diameter (in) 7/8 HFP8-7/8 92 1/4 HFP8-1 1/8 92 1/4 1 1/8 HFP9-7/8 104 1/4 7/8 HFP9-1 1/8 104 1/4 1 1/8 HFP10-7/8 11 1/4 7/8 HFP10-1 1/8 11 1/4 1 1/8 3-1/2 3-1/2 HFP11-7/8 128 1/4 7/8 HFP11-1 1/8 128 1/4 1 1/8 HFP12-7/8 140 1/4 7/8 HFP12-1 1/8 140 1/4 1 1/8 HFP13-7/8 152 1/4 7/8 HFP13-1 1/8 152 1/4 1 1/8 POST NOMENCLATURE HFP9-7/8 HD DIA NOMINAL HEIGHT SERIES Hardy Frame Post Hardy Frame Post HARDY on concrete FRAME POST HARDY on nut BOTTOM FRAME and washer POST BOTTOM ON (requires DOUBLE 5,000 NUT psi ON DOUBLE NUT non-shrink grout) 8

PRE-ASSEMBLED MOMENT FRAME INSTALLATIONS 5 1/4 " AT D9, D12 7 1/2 " AT D18 2x TOP PLATE BY OTHERS 2x Top Plate Connects to 3x nailer with USP MP4 F (or LTP 4) connectors on each face. Quantity by Building Design Professional. SIDEPLATES STEEL COLUMN 4" AT D9, D12 " AT D18 2x COLUMN NAILER BASE PLATE 1/2" SIDEPLATE COLUMN SIDEPLATE BEAM VARIES W in (steel to steel) W out (outside of 2x to outside of 2x) h 1 (Top of concrete to lowest point of header/sideplate assembly Actual Double Plate Height (Top of concrete to top of field installed 2x) FILL GAP WITH 5000 PSI (MIN) NO-SHRINK GROUT EDGE VIEW TOP OF CONCRETE 5" AT D9, D12 7" AT D18 ANCHOR BOLT ASSEMBLY Section of Header With Nailers and Plates Section at Roof Framing Elevation of header tie plate connectors required on both faces for shear transfer Pre-installed wood nailers 2x4 at all column flanges 3x at top and bottom of D9, D12 header 3x8 at top and bottom of D18 header Section of Header With Nailers and Plates Section at Roof Framing On Nuts On & Washers Nuts & Washers (Requires (Requires 5,000 psi 5,000 Non-Shrink psi Non-Shrink Grout Grout On Nuts & Washers (Requires 5,000 psi Non-Shrink Grout On Nuts & Washers (Requires 5,000 psi Non-Shrink Grout On Nuts & Washer pinned base (requires 5,000 psi non-shrink grout) On Concrete On Concrete Section of Header With Nailers and Plates Elevation of header tie plate On Concrete Section of Header Section at Joist On Concrete connectors - Section of Header With Nailers and Plates required on both faces with Nailers and Plate Hanging Condition for shear transfer Section at Roof Framing Section of Header With Nailers and Plates Section at Joist - Bottom Cord Bearing Section at Joist - Hanging Condition Section at Roof Framing Elevation of header tie plate connectors required on both faces Elevation of for header shear tie transfer plate connectors required on both faces for shear transfer On Concrete pinned base Section at Roof Framing Section at Elevation of header tie plat connectors required on bo for shear transfer 9 On Nuts & Washers Fixed Base On Nuts On & Washers Nuts & Washers Fixed Base Fixed Base On Nuts & Washers Fixed Base On Concrete Fixed Base On Concrete On On Concrete Fixed Fixed Base Fixed Base Base On Concrete Fixed Base Section at Joist - Bottom Cord Bearing Section at Joist - Bottom Cord Bearing Elevation at header USP MP4-F (or LTP4) connectors on each face for shear transfer. Minimum quantity by Building Design Professional. Section at Joist - Hanging Condition Section at Joist - Bottom Cord Bearing Section at Joist - Hanging Condition

MOMENT FRAME CONNECTOR INFORMATION Nominal 8 foot Wall Height ( 8 0-3/4 ) Nominal 9 foot Wall Height ( 9 0-3/4 ) Model W in W out h1 Weight Model W in W out h1 Weight Number ft-in ft-in ft-in lbs Number ft-in ft-in ft-in lbs HF-D9 x8 7 8 4 7 0 1/4 987 HF-D9 x9 7 8 4 8 0-1/4 1,04 HF-D9 8x8 8 7 10 4 7 0 1/4 1,051 HF-D9 8x9 8 7 10 4 8 0-1/4 1,128 HF-D9 8x8 H 8 7 10 4 11-1/4 1,102 HF-D9 8x9 H 8 7 10 4 7 11-1/4 1,179 HF-D12 8x8 8 7 10 10-1/2 7 0 1/4 890 HF-D12 8x9 8 7 10 10-1/2 8 0-1/4 938 HF-D18 8x8 8 7 11 9-1/2 11-3/4 1,412 HF-D18 8x9 8 7 11 9-1/2 7 11-3/4 1,490 HF-D9 10x8 10 7 12 4 11-1/4 1,173 HF-D9 10x9 10 7 12 4 7 11-1/4 1,250 HF-D12 10x8 10 7 12 10-1/2 7 0 1/4 954 HF-D12 10x9 10 7 12 10-1/2 8 0-1/4 1,002 HF-D18 10x8 10 7 13 9-1/2 9-1/4 1,50 HF-D18 10x9 10 7 13 9-1/2 7 9-1/4 1,728 HF-D9 12x8 12 7 14 4 11-1/4 1,244 HF-D9 12x9 12 7 14 4 7 11-1/4 1,321 HF-D12 12x8 12 7 14 10-1/2 7 0 1/4 1,018 HF-D12 12x9 12 7 14 10-1/2 8 0-1/4 1,07 HF-D18 12x8 12 7 15 9-1/2 9-1/4 1,74 HF-D18 12x9 12 7 15 9-1/2 7 9-1/4 1,824 HF-D9 14x8 14 7 1 4 11-1/4 1,315 HF-D9 14x9 14 7 1 4 7 11-1/4 1,392 HF-D12 14x8 14 7 1 10-1/2 7 0 1/4 1,083 HF-D12 14x9 14 7 1 10-1/2 8 0-1/4 1,131 HF-D18 14x8 14 7 17 9-1/2 9-1/4 1,842 HF-D18 14x9 14 7 17 9-1/2 7 9-1/4 1,919 HF-D18 14x8 H 14 7 17 10 5-3/4 2,372 HF-D18 14x9 H 14 7 17 10 7 5-3/4 2,471 HF-D9 1x8 1 7 18 4 10-1/4 1,42 HF-D9 1x9 1 7 18 4 7 10-1/4 1,539 HF-D18 1x8 1 7 19 19-1/2 9-1/4 1,938 HF-D18 1x9 1 7 19 9-1/2 7 9-1/4 2,015 HF-D18 1x8 H 1 7 19 10 5-3/4 2,502 HF-D18 1x9 H 1 7 19 10 7 5-3/4 2,01 HF-D18 18x8 H 18 7 21 10 5-3/4 2,33 HF-D18 18x9 H 18 7 21 10 7 5-3/4 2,732 HF-D18 20x8 H 20 7 23 10 5-3/4 2,73 HF-D18 20x9 H 20 7 23 10 7 5-3/4 2,82 Nominal 10 foot Wall Height ( 10 0-3/4 ) Model W in W out h1 Weight Number ft-in ft-in ft-in lbs HF-D9 x10 7 8 4 9 0-1/4 1,141 HF-D9 8x10 8 7 10 4 9 0-1/4 1,205 HF-D9 8x10 H 8 7 10 4 8 11-1/4 1,25 HF-D12 8x10 8 7 10 10-1/2 9 0-1/4 987 HF-D18 8x10 8 7 11 9-1/2 8 11-3/4 1,57 HF-D9 10x10 10 7 12 4 8 11-1/4 1,327 HF-D12 10x10 10 7 12 10-1/2 9 0-1/4 1,051 HF-D18 10x10 10 7 13 9-1/2 8 91/4 1,805 HF-D9 12x10 12 7 14 4 8 11-1/4 1,398 HF-D12 12x10 12 7 14 10-1/2 9 0-1/4 1,115 HF-D18 12x10 12 7 15 9-1/2 8 9-1/4 1,901 HF-D9 14x10 14 7 1 4 8 11-1/4 1,49 HF-D12 14x10 14 7 1 10-1/2 9 0-1/4 1,180 HF-D18 14x10 14 7 17 9-1/2 8 9-1/4 1,997 HF-D18 14x10 H 14 7 17 10 8 5-3/4 2,570 HF-D9 1x10 1 7 18 4 8 10-1/4 1,1 HF-D18 1x10 1 7 19 9-1/2 8 9-1/4 2,093 HF-D18 1x10 H 1 7 19 10 8 5-3/4 2,701 HF-D18 18x10 H 18 7 21 10 8 5-3/4 2,831 HF-D18 20x10 H 20 7 23 10 8 5-3/4 2,92 MOMENT FRAME NOMENCLATURE HF-D9 8 X 9 H H SERIES (HEAVY DUTY) AS OCCURS NOMINAL 1ST STORY DOUBLE PLATE HEIGHT (FT) NOMINAL CLEAR SPAN (FT) NOMINAL WIDTH OF COLUMN (IN) HARDY FRAME For a complete list of standard sizes see the Hardy Frame Moment Frame Catalog Two Story Frames available All model numbers shown ship pre-assembled; over-sized frames ship as knock-down units that require field welding and special inspection by others D9 =BUILT UP 8x3 4" 9" 10" D12 COLUMN W12 x 22 " 12 1/4 13 1/4 3" 4" 5" Template Kits Model Rod Dia Rod Lgth QTY HFT HFBB HFTK-D9 3/4 in 32 8 2 2 HFTK-D12 3/4 in 32 8 2 2 HFTK-D18 1 1/8 in 34 8 2 2 Rod material is ASTM F-1554 grade 3 Plate washers, flat washers and nuts included. Double nut at HFT Top of bolt to top of concrete is 4 ¼" Measured Distance from notch to notch is Moment Frame W IN dimension 2x4s Placed Flat Double nut at plate washer and bolt brace 3" 4" 5" D9 =BUILT UP 8x3 4" 9" 10" BASE PLATE = COLUMN = 4 x COLUMN WOO ANCHORS = ¾ ALL THREAD D12 COLUMN W12 x 22 ASTM A53 Grade A BASE PLATE = coupling nut may be COLUMN = 4 x used to extend 3" 4" rod 5" length when necessarycolumn WOO ANCHORS = ¾ " 12 1/4 ALL THREAD Bolt Brace and plate washers 13 1/4 D18 = W18 x 35 " 17 3/4 18 3/4 D18H = W18x4 Form boards " 18" 18 3/4" 3" 4" 5" 4" " 7" 4" " 7" BASE PLATE COLUMNS W WOOD TO COLUMN W WOOD TO W ANCHORS = ALL THREA BASE PLATE COLUMNS W WOOD 10 TO COLUMN W WOOD TO W ANCHORS = ALL THREA

TM ATTACHMENTS Hole chart and Attachments 3 DIAMETER HOLE PROVIDED IN FACE OF 18 AND 24 WIDE PANELS 9 1 UPPER HALF (PANEL HEIGHT 2) Hole Chart An additional 1 diameter hole may be drilled in the upper half of the Panel when it is located in the hatched area. To drill more than one hole, a larger diameter hole or a hole in a location outside of the hatched area, contact Hardy Frames, Inc. There is not an inside or outside face for the Panel. To avoid the need for additional holes, orient the open face toward the fixture to be installed. 4 4 Wood For attaching wood, siding, drywall and other surface finishes to the Panel or face #10 Flat or Wafer Head, self-tapping screws with a Winged self drilling (SD) SELF DRILLING SD POINT WING TIP SD point SELF are TAPPING recommended. When SELF connecting TAPPING to the edge of Panels, use a #12 diameter screw. BUGLE HEAD WAFER HEAD SELF DRILLING SD POINT WING TIP SD SELF DRILLING SD POINT FLAT BUGLE TRUSS HEAD SELF MODIFIED WAFER TAPPING TRUSS HEAD WING TIP SD SELF DRILLING SD POINT WING TIP SD BUGLE HEAD Steel HEX HEAD WAFER HEAD When attaching steel connectors FLAT TRUSS (12-gage maximum) MODIFIED TRUSS fixtures, electrical boxes, wire BUGLE mesh, HEAD etc. to SELF the WAFER DRILLING Panel HEAD or Brace SD POINT Frame face WING #10 Hex, TIP SD Flat Truss or Modified Truss Head with a Self Drilling (SD) point FLAT are TRUSS recommended. MODIFIED When TRUSS connecting to the edge of Panels, use a HEX #12 HEAD diameter. BUGLE HEAD WAFER HEAD FLAT TRUSS MODIFIED TRUSS HEX HEAD HEX HEAD FLAT TRUSS SELF DRILLING SD POINT MODIFIED SELF TRUSS TAPPING WING TIP SD HEX HEAD BUGLE HEAD WAFER HEAD FLAT TRUSS 789 S. Victoria Ave., Suite 200, Ventura, California 93003 800 754-3030 www.hardyframe.com HEX HEAD MODIFIED TRUSS