USP SIP Connection Manual
|
|
|
- Suzan Booker
- 10 years ago
- Views:
Transcription
1 USP SIP Connection Manual Structural Insulated Panels (SIP) Lumberton Largo Montgomery Humble Livermore Thornhill, Ontario Copyright 2013 United Steel Products Company
2 2 Company Information Company History USP Structural Connectors (United Steel Products Company) has been designing, manufacturing, and marketing construction hardware for over 50 years. The company s experience in marketing, engineering, and service has allowed USP to be a leader in developing new connectors for a changing construction industry. Burnsville, MN Corporate Office Southcross Drive Suite 200 Burnsville, MN Phone: Phone: Fax: Livermore, Western Region 2150 Kitty Hawk Road Livermore, CA Phone: Phone: Fax: Largo, Eastern Region nd Street North Largo, FL Phone: Fax: Thornhill, Canadian Office 221 Racco Parkway Thornhill, ON L4J 8X9 Phone: Fax: USP Operations Include ISO 9001:2000 Registered USP Structural Connectors in Montgomery, Livermore, Largo, and North Wilkesboro achieved registration of its quality system in accordance with the requirements of ISO 9001:2000 Company Information General Information Index Fasteners Anchor Bolts , 9 Foundation Anchors Holdowns , 11 Table of Contents Nine strategically placed manufacturing and warehousing locations. In-house quality control and testing with independent, third-party plant inspection, and test witnessing. On staff licensed professional engineers. Our National Factory Technical Sales Force is ready to help with application questions. Ongoing regional and national code evaluations as products are developed. Product Questions & Answers The Customer Service/Technical Assistance staff is ready to answer your questions and help solve your connector related problems. Our staff can assist you in developing economical solutions to your structural connection problems. When calling for Technical Assistance, please have the following information ready: Which USP product are you using? What is connector application? What is the header material and application? What is the load requirement? Foundation Straps Floor Ties Joist Hangers Ridge Ties Specification Tools Tiedowns WARRANTY United Steel Products Company warrants its products to be free from defects in material and workmanship. Said products are further warranted as to adequacy of design, provided products are used in strict accordance with United Steel Product Company s current published design limits and are installed in a workmanlike manner. (Said warranties do not apply in the event products are cut, notched, welded, drilled or in any way altered). No warranty applies if deterioration occurs due to environmental conditions. United Steel Products Company s obligations under this warranty shall be limited to the replacement or repair of those products demonstrated to be defective. Such remedy shall constitute Customer s sole and exclusive remedy and Customer hereby agrees that no other remedy (including, but not limited to claims for INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, OR ANY CAUSE, LOSS, ACTION, CLAIM OR DAMAGE, INCLUDING LOSS OF TIME, WHATSOEVER, OR INJURY TO PERSON OR PROPERTY OR ANY OTHER CONSEQUENTIAL DAMAGE OR INCIDENTAL OR ECONOMIC LOSS) shall be available to Customer whether said claims be asserted on the basis of warranty, negligence, strict liability or otherwise. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ALL SUCH OTHER WARRANTIES BEING HEREBY EXPRESSLY EXCLUDED. Customer Service / Technical Assistance Burnsville, MN Corporate Office
3 General Information 3 Please Note USP Structural Connectors reserves the right to change specifications, designs, and models without notice and liability for such changes. This catalog may not be reproduced in whole or in part without the prior written approval of USP Structural Connectors. This SIP Connection publication was designed as a general reference for the USP Product Line. See USP s Full Line Catalog for complete product information. To achieve the allowable loads presented in this catalog, all specified fasteners must be used and proper installation procedures observed. Verify that the dimensions of supporting members are sufficient to receive specified fasteners. Any product modifications void the warranty unless prior written permission of USP Structural Connectors is obtained. Nails specified as 8d, 10d, 16d, and 20d are common wire nails. See USP s Full Line Catalog for testing, material, and code information. This publication shows common SIP connections. Please refer to SIP manufacturers literature for complete SIP connection information. Allowable loads shown in this publication are based on connections to wood members. Fasteners connecting only to the panel skin have not been considered. NDS Standards The load resistance values presented in this catalog reflect the calculation criteria set forth in the 1991 revised and 1997 National Design Specification for Wood Construction (NDS ) published by the American Forest and Paper Association. The values shown in this catalog supercede those previously printed. Douglas Fir-Larch or Hem Fir Equivalent Capacity Unless otherwise noted, the published design loads in this catalog apply to Spruce-Pine-Fir lumber. In this catalog, no provisions are made to increase these loads when using Douglas Fir-Larch, Southern Pine, or Hem Fir lumber. Contact USP Technical Assistance for additional information regarding load capacities for species other than Spruce-Pine-Fir. Testing On all structurally-rated products, USP performs full-scale testing in accordance with ASTM D 1761, the standard recognized by all domestic code agencies. All final testing is conducted by a third-party testing laboratory. Material USP Structural Connectors are manufactured from prime quality steel which meets ASTM A 653 requirements for galvanized steel, and ASTM A 1011, or ASTM A 36 for hot-rolled steel. Finish All galvanized products have a zinc coating as specified in ASTM A 653. Hot-dip galvanized parts are galvanized after fabrication per ASTM A 123. Non-galvanized steel products are prime coated for corrosion protection. Corrosion Resistant Finishes USP Structural Connectors offers three options for improved corrosion resistance of their connectors. TRIPLE ZINC G-185 Galvanization Triple Zinc (TZ) galvanizing provides a prefabrication coating of 1.85 (G-185) ounces of zinc per square foot of surface area measured in accordance with ASTM A 653. Required Fastener: Hot-dip galvanized fasteners Hot-Dip Galvanized (HDG) coating provides an after fabrication hot-dipped zinc coating. The coating thickness is dependent on the connector material, but generally ranges from 1.1 to 2.3 ounces of zinc per square foot of surface. Hot-dip products meet requirements set forth in ASTM A 153. Required Fastener: Hot-dip galvanized fasteners Stainless Steel (SS) is the best option for corrosion protection. Quality stainless steel (316SS grade steel) is used to fabricate connectors. Although costs are higher, some applications may need the virtual corrosion proof quality of stainless steel. Required Fastener: Stainless Steel fasteners Connector Use with Preservative Treated Wood For minimum corrosion protection, USP Structural Connectors recommends consumers use Triple Zinc G-185 or HDG connectors in all outdoor applications and with treated lumber. In general, connectors, including anchors and fasteners, installed in corrosive environments or exposed to corrosive materials, or chemicals, can be damaged, possibly resulting in the reduction of load values. Standard G90 connectors should not be installed in potentially corrosive environments. For more information on industry changes to pressure treated wood and associated use of connectors and fasteners refer to USP s Corrosion Protection News, USP953, or visit our website at. [email protected] Copyright 2013 United Steel Products Company
4 4 Index SIP Foundation Connections Shear Wall end post Tension compression post at end of shear wall STAD8 Page 10 STAD8RJ Page 10 MP4F Page 8 Floor FA3 Page 8 PHD Page 9 STB series Anchor Bolt Page 9 MP4F Page 8 TDX Page 9 ST2-TZ Page 8 STB series Anchor Bolt Page 9 ST2-TZ Page 8 Customer Service / Technical Assistance Burnsville, MN Corporate Office
5 Index 5 SIP Multi-Story Connections Floor MP4F Page 8 PHD Pages 11 THF Page 13 MSTC Page 11 THO Pages 12 & 13 SIP Rafter & Truss Connections RT7A Page 15 LSTA Page 14 RT3 Page 15 Double top plate 2x top plate [email protected] Copyright 2013 United Steel Products Company
6 6 Fasteners Nails NA series Optional Nails for Face Mount Hangers and Straight Straps load table Proper fasteners are a critical component in a sound wood frame structure. To ensure successful installations of its connectors, USP offers a full range of structurally-rated nails. All galvanized nails are finished using the Hot-dip method to assure total anticorrosion coverage. Stainless steel nails are available on a stock basis in two sizes: 8d x 11/ 2 and 10d x 11/ 2 (see product chart). Finish: See chart NA9D NA16D Installation: Allowable shear values assume nail embedment into the wood of the entire nail or 12 nail diameters (whichever is less). Otherwise, the nail must be embedded at least 6 nail diameters, with the load reduced using the following equation: Reduced Load = Published Load x Actual Penetration Nail Diameter x 12 Load reductions may occur if nails are used other than those specified. See the chart Optional Nails for Face Mount Hangers and Straight Straps for load reduction Minimum Fastener penetration factors regarding nail substitutions. Nail Specification table Customer Service / Technical Assistance Burnsville, MN Corporate Office
7 Fasteners & Anchor Bolts 7 Wood Screws WS series The WS Wood Screw is a self-drilling screw used for numerous framing applications. This screw features a reverse locking serration on the bottom of the screw head to prevent over tightening against a steel plate which could cause the screw head to shear off. The USP head stamp identifies screws for easy inspection. Screw shear capacities are based on a diameter of when the shear plane is on the screw shank (SH) and when the shear plane is on the knurl or threads (T ). USP WS Wood Screws have a bending yield strength of 217,000 psi. For conditions not charted here, screw loads may be calculated as shown in the current NDS and increased for duration of load. SH USP Screw name length 3/8 Serrations Materials: 1/4 diameter Grade 5 steel Finish: Yellow zinc dichromate Codes: ICBO 5634, L.A.City RR Installation: Screws are self-drilling. Install using a low speed clutch drill with 3/8 hex head driver. The washer head should be flat to the surface and the serrations will oppose turning and release the clutch. Do not over-tighten the screws. L T Cut threads Self-drilling point Additional Anchor Designs Anchor types shown are made by others and used with USP holdowns. The design engineer may specify an alternate anchorage system, provided the anchor diameter is the same. See the Strength Design of Anchorage in Concrete by R.A. Cook, published by the Portland Cement Association and the 1997 Uniform Building Code. Anchor Type A L- bolt: Bend without cracking the outside of the bend portion. Place #4 rebar 3 to 5 from the top center of the foundation. le de 4d Anchor Type B Hex-head bolt: Design loads for Anchor Type B are calculated using a full shear cone. Multiple reductions must be taken for corner and edge distance conditions. 8 le de 2 le Min. [email protected] Copyright 2013 United Steel Products Company
8 8 Foundation Anchors Foundation Anchors FA3 Foundation Anchors ST2-TZ SIP MP4F FA3 Load Direction Conventions FA3 installation 1 7/16 Perpendicular F 2 Uplift F 1 Lateral ST2-TZ installation 4 5 /8 F 1 F 2 Out 53/4 Download FA3 1 ST2-TZ & FA3 Capacity ST2-TZ Double pour installation Spread sill flanges to sill width prior to insertion into wet concrete MP4F Capacity 3 PLATE LINE PLATE LINE /4 MP4F FA3 & MP4F are available in Triple Zinc G-185 for extra corrosion protection. See page 3 for additional information or USP s Full Line Catalog. ST2-TZ Customer Service / Technical Assistance Burnsville, MN Corporate Office
9 Holdowns & Anchor Bolts 9 Holdowns PHD & TDX series PHD Capacity W Double lap back increases overall stiffness and fastener shear values H Slotted seat design allows adjustment for mislocated anchor bolt 1 5 /8 D CL PHD PHD, STB, & TDX installation TDX Capacity H End Distance W TDX CL D Anchor Bolts STB series STB Bolt Capacity Identification stamp & alignment indicator H Embedment line L E STB The STB Series is available in Hot-dip Galvanized for extra corrosion protection. See page 3 for additional information or USP s Full Line Catalog. [email protected] Copyright 2013 United Steel Products Company
10 10 Foundation Straps Foundation Strap STAD series Shear wall end post Plan View installations Holdown At straight wall Holdown End Post At corner W STAD Capacity STAD edge installation STAD corner installation L Embedment line CS l E D STAD W L CS l E D STADRJ Customer Service / Technical Assistance Burnsville, MN Corporate Office
11 Holdowns & Floor Ties 11 Holdowns PHD & TDX series Floor Tie MSTC series End post Double lap back increases overall stiffness and fastener shear values W L H PHD installation Slotted seat design allows adjustment for mislocated anchor bolt 15/8 CL D PHD MSTC installation 3 1 1/2 3 MSTC PHD Capacity MSTC Capacity TDX Capacity H End Distance W TDX CL D [email protected] Copyright 2013 United Steel Products Company
12 12 Joist Hangers Top Mount Joist Hanger THO series THO with 2x top plate installation THO with double top plate installation TF H W D THO continued on next page Customer Service / Technical Assistance Burnsville, MN Corporate Office
13 Joist Hangers 13 THO series continued Face Mount Joist Hanger THF series THF installation Additional diamond nail holes for maximum nailing H Standard round nail holes for minimum nailing W THF D Patented dimple allows 45 nailing Some model designs may vary from illustration shown [email protected] Copyright 2013 United Steel Products Company
14 14 Ridge Ties Ridge Tie LSTA series LSTA Ridge Tie installation LSTA9 9 LSTA12 12 LSTA15 15 LSTA18 18 LSTA21 21 LSTA24 24 LSTA30 30 LSTA36 36 Customer Service / Technical Assistance Burnsville, MN Corporate Office LSTA
15 Tiedowns & Specification Tools 15 Tiedowns RT3 & RT7A Hurricane Tie installations to achieve twice the load (Top View) Wall top plate Install diagonally across from each other for minimum 11/2 truss. RT7A installation 11/2 RT3 installation 19/16 Specification Tools /2 Comprehensive Web Site 2 7 /16 11/2 RT7A Contains all USP literature in a printable.pdf format. CAD Menu Program and Drawing Library downloads. Quick and Easy literature ordering. Register on-line at Web Site Watch Registration and automatically receive product updates through your . 13/8 4 1 /4 13/8 RT3 JUS210-2 TOP VIEW JUS210-2 FRONT VIEW JUS210-2 SIDE VIEW CAD Library CAD Library contains over 350 illustrations in.dxf and.dwg formats Find drawings quickly by USP Stock No. or Reference No. High Wind Illustrations are also available CAD Menu Program Install a new USP Drop Down Menu in your AutoCAD menu bar (AutoCAD r14, AutoCAD 2000, 2000i, 2002, 2004, 2005). Import scalable USP product drawings directly into your details or section drawings Available in 3-view format; top, front, and side, where applicable. [email protected] Copyright 2013 United Steel Products Company
16 Your Local Dealer / Distributor Customer Service Burnsville, MN Phone: Fax: Manufacturing: Montgomery, MN Livermore, CA Largo, FL Thornhill, Ontario Warehouses: Humble, TX Lumberton, NJ Copyright 2013 United Steel Products Company
USP SIP Connection Manual www.uspconnectors.com
SIP Connection Manual www.connectors.com Structural Insulated Panels (SIP) supplies quality products to build Stronger Safer Structures Los Angeles San Francisco Minneapolis Houston Tampa Charlotte Philadelphia
By SP Partners, LLC. www.rainbowatticstair.com INSTALLATION GUIDE. Prestige
By SP Partners, LLC www.rainbowatticstair.com INSTALLATION GUIDE Prestige IMPORTANT READ THIS FIRST Inspect stair for any damage prior to installation. Stair is NOT to be installed while home is under
Connection Solutions
Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,
Code Compliant Repair and Protection Guide
PROFESSIONALS Code Compliant Repair and Protection Guide FOR THE INSTALLATION OF UTILITIES IN WOOD FRAME CONSTRUCTION 800-999-5099 www.strongtie.com CONTENTS Repair and Protection Products... 3 Plumbing/Mechanical
This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Residential Decks Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
INSTRUCTION BOOK FOR. Lace And Grommet Theater-Type Screens
INSTRUCTION BOOK FOR Lace And Grommet Theater-Type Screens Pre-Installation Da-Lite Lace and Grommet screens are custom made to meet the requirements for large surface installation of a relatively permanent
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.
P-5 The P-5 is hot forged from carbon steel. The formed head provis spherical seating that the Lifting Eye engages, while a disc-shaped foot is embedd in the concrete. Due to its being a forged part, the
RPS - [email protected] - 858 755 4505-12478 San Bruno Cove, San Diego, CA 92130
RPS - [email protected] - 858 755 4505-2478 San Bruno Cove, San Diego, CA 9230 SWH Solar Mount Rail R-MR-SW-SR-0.5, R-MR-SW-SR-2, R-MR-SW-SR-4, R-MR-SW-SR-4B, R-MR-SW-SR-7 Part No. MR-SW-SR-0.5, MR-SW-SR-2,
POST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
ICC-ES Evaluation Report
ICC-ES Evaluation Report ESR-2369 Reissued May 1, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical
Assembly Instructions
Assembly Instructions Overhead Storage Rack 4 x 8 3 x 8 2 x 8 4 x 6 3 x 6 2 x 6 4 x 4 Two 4x8 Racks Pictured Eagle Industrial Group, Inc. 25471 Arctic Ocean Drive Lake Forest, CA 92630 877.655.3443 888.313.9228
Installation Instructions: (Part # SB76880) XRC Armor Front Fender Kit
WARNING: Check with Local and State laws before installing this accessory! NOTE: Carefully read entire instructions thoroughly before attempting to install this part. Parts Included: Qty Parts Included:
Featuring TJ Rim Board and TimberStrand LSL
#TJ-8000 SPECIFIER S GUIDE TRUS JOIST RIM BOARD Featuring TJ Rim Board and TimberStrand LSL Multiple thicknesses, grades, and products to cover all your rim board needs 1¼" Thickness matches lateral load
Superform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
PATHWAY Classic Series with Handrails Portable Wheelchair Ramp INSTRUCTIONS FOR USE 6428 REV A 05-21-09
PATHWAY Classic Series with Handrails Portable Wheelchair Ramp INSTRUCTIONS FOR USE. INSTRUCTIONS 1) FOR EZ-ACCESS PATHWAY RAMP WITH HANDRAILS 850 pound weight capacity. Available in 4, 6, 8 & 10 lengths.
Wood Projects Outdoors. Post Hole Specifications. Deck Span Tables. www.jon Eakes.com
Wood Projects Outdoors Post Hole Specifications & Deck Span Tables www.jon Eakes.com Building Fences The depth of the fence posts into the ground must be at least one foot below the frost level for your
Guidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
Super Slider ADJUSTABLE FROM 3.5-12 Model #HD26229
Super Slider ADJUSTABLE FROM 3.5-12 Model #HD26229 IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS
Uncovered Decks & Porches
Uncovered Decks & Porches Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed
VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249
VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249 IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS
Residential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: [email protected] Planning and Development Services Department Residential Decks
TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For:
TEST REPORT Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PRODUCT: Gorilla Column PVC Porch Post System with PVC Base / Cap Plates, PVC Bushings and 2-3/8 in Diameter and 3-1/2 in Diameter Galvanized
STANDARD OPEN PATIO COVER
STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
March 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
RZ Guardrail System Installation Manual
TM RZ Guardrail System Installation Manual RZ Guardrail System Compliance is based on OSHA standards: (Standards - 29 CFR) 1910.23 (e) and (Standards - 29 CFR) 1926.502 (b) Failure to read, understand
SECTION 1 GENERAL REQUIREMENTS
Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,
LEGACY REPORT ER-5110. www.icc-es.org. ICC Evaluation Service, Inc. Reissued November 1, 2003. Legacy report on the 1997 Uniform Building Code
LEGACY REPORT Reissued November 1, 2003 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900
Guidelines for Earthquake Bracing Residential Water Heaters
Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the
Calvert USA, Inc. Attic Stairs
Calvert USA, Inc. Attic Stairs Instructions for installation of vertical opening access stairs Model numbers: 7035 through 7047 Calvert USA, Inc., P.O. Box 841, Solomons, MD 20688, Tel. (410) 286-1430,
COLORADO MODEL. 35 x 65 SPECIFICATIONS
COLORADO MODEL 35 x 65 SPECIFICATIONS Dimensions: Roof Dimensions 35-0 x 65-0 Column Dimensions (center to center) 31-0 x 30-6 Minimum Clearance 14-0 Roof Height @ Peak ±18-8 Curved Roof ±42-6 radius Square
Retractable Screen. Replacement Screen Instructions
Retractable Screen Patent Pending Replacement Screen Instructions For RTS, RET, & RTM Products ATTENTION! Retractable screens are not intended to provide security or provide for the retention of objects,
Post and Beam Construction
Post and Beam Construction A Presentation By the Canadian Wood Council Canadian Conseil Wood canadien Council du bois Early settlers introduced the concept of post and beam construction in North America
Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049
Sports and High Mast Lighting Poles 4 High Mast Lighting Poles General American LitePole offers a raising and lowering system that allows for ease of maintaining the lighting system at ground level. Ideal
Typical Deck Details
Fairfax County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code The design details in this document apply to residential, single-level decks only. Construction cannot deviate
Patio Covers / Carports
Patio Covers / Carports Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed
SECTION 02845 GUARDRAILS
SECTION 02845 GUARDRAILS PART 1 - GENERAL 1.01 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals necessary and repair, replace or install all types of guardrails as specified herein
Operations and Instruction Manual Might Swivel - Part # 310273 Concrete and Steel Anchorage Connector ANSI Z359.1 10,000 lbs / 44kn
Safety.. Operations and Instruction Manual Might Swivel - Part # 310273 Concrete and Steel Anchorage Connector ANSI Z359.1 10,000 lbs / 44kn Description: Technical: Zinc plated forged heat treated steel,
ATLANTA MODEL SPECIFICATIONS
ATLANTA MODEL 50 SPECIFICATIONS Dimensions: Roof Dimensions (point to point) 50-0 Column Dimensions (out to out of columns) 44-0 Eave Height 8-0 Roof Height @ Peak ±21-8⅞ Hip Roof 6:12 pitch Square Feet
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
DENVER MODEL 30 X 30 SPECIFICATIONS
DENVER MODEL 30 X 30 SPECIFICATIONS Dimensions: Roof Dimensions 30-0 x 30-0 (4) Columns (Center to Center) 25-6½ x 25-6½ Minimum Clearance 8-0 Roof Height @ Peak Dependent on Col. Ht. Hip Roof 4:12 pitch
TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION
TECHNICAL NOTE On Cold-Formed Steel Construction 1201 15th Street, NW, Suite 320 W ashington, DC 20005 (202) 785-2022 $5.00 Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006
USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2
Remote Faucet Pump System USE &CARE GUIDE See Important Safeguards on page 2 An exclamation point within an equilateral triangle is intended to alert user to the presence of important operating and maintenance
Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:
Two most common lock nut groups: 1. PREVAILING TORQUE a design feature of the lock nut produces friction between threads of mated components thereby increasing the force needed to tighten as well as loosen
Hilti, Inc. 5400 South 122 nd East Avenue Tulsa, OK 74146. 1-800-879-8000 www.hilti.com
Attached are page(s) from the 2014 Hilti North American Product Tech Guide. For complete details on this product, including data development, product specifications, general suitability, installation,
AT&T. PARTNER Plus Door Phone. Installation and Operation Manual
AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a
Seismic Technical Guide
Technical Document Seismic Technical Guide Hanger Wire Attachment Code Requirements 1 The International Building Code (IBC) defines the requirement for hanger wire and their supports and attachment methods.
Installation Instructions GOOSENECK MOUNTING KIT Chevrolet/GMC 1500/2500/3500 All except 4-door Crew-Cab
GOOSENECK MOUNTING KIT Equipment Required: Fastener Kit: F Wrenches: 3/4, 7/8, 15/16 Drill Bits: 1/4 Other Tools: Drill WARNING: Under no circumstances do we recommend exceeding the towing vehicle manufacturers
LIST PRICE BOOK MALLEABLE CAST IRON PRESS FITTINGS FOR SCH. 10 40 BLACK & GALVANIZED STEEL PIPE
FASTLOCK fittings are not currently approved for use with gas or fire protection applications. FITTINGS FOR STEEL PIPE LIST PRICE BOOK MALLEABLE CAST IRON FITTINGS FOR SCH. 10 40 BLACK & GALVANIZED STEEL
RadianceRail Installation Guide
RadianceRail Installation Guide Installing RadianceRail with CableRail by Feeney... 2 Installing CableRail by Feeney for RadianceRail... 7 Installing RadianceRail Stairs with CableRail by Feeney... 10
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
The Stabilizer TM. Benefits. www.griptite.com. Supplemental support system for sagging beams and floor joists within a crawl space
The Stabilizer TM Supplemental support system for sagging beams and floor joists within a crawl space Pre-drilled holes in steel plate allow for connection to beam or floor joists. Benefits Levels and
PC-Concrete Injectable Concrete Anchoring and Repair System
PC-Concrete Injectable Concrete Anchoring and Repair System DESCRIPTION: PC-Concrete is a two component (1:1 ratio), 100% solids, high modulus, structural epoxy paste. PC-Concrete is a solvent free, no
Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION
SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.
Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. www.r-control.com CONTROL, NOT COMPROMISE.
R-CONTROL s STRUCTURAL INSULATED PANELS Note: Information deemed reliable at time of printing. Please visit www.r-control.com for latest information. June 2012 CONTROL, NOT COMPROMISE. www.r-control.com
Best Barns USA Assembly Book
Best Barns USA Assembly Book Revised November 27, 2013 the Easton - R 12'x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This manual is copyrighted.
Dock Hardware & Accessory Products Catalog
Dock Hardware & Accessory Products Catalog Product Page # Product Page # Angle Brackets/Clips 8 Back Up Plate 5 Backing Plate/Hurricane Stop 10 Carriage Bolt Sets 4 Chain Retainer 10 Connector Pin Set
INSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
Mark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER 1.800.591.9360 TECHNICAL ASSISTANCE FAX: 1.626.855.4894
ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 9744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FREEZE RESISTANT WALL MOUNTED EMERGENCY EYEWASH
AA Solar and Sun Power Plus
AA Solar and Sun Power Plus www.aasolar.co.nz www.sunpowerplus.co.nz -1- Contents Chapter Title Page 1 General information 3 2 Safety and Installer Responsibilities 4 3 Technical Specifications 5 4 Tools
REPORT HOLDER: JENWEST ENTERPRISES LLC, DBA ADVANCED CONNECTOR SYSTEMS 321 SOUTH 1240 WEST #15 LINDON, UTAH 84042 EVALUATION SUBJECT:
0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3635 Reissued 04/2016 This report is subject to renewal 04/2018. DIVISION: 03 00 00 CONCRETE
CPA Steel Stud Framing Page 1 of 11
CPA Steel Stud Framing Page 1 of 11 STEEL STUD FRAMING General Requirements City of Palo Alto (CPA) Building Inspection Division 285 Hamilton Ave. Inspection Request: 650 329-2496 Building Division IVR#
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Video Conference Shelf for Low Profile Flat-Panel Mounts NORTH AMERICA 3130 East Miraloma Avenue Anaheim, CA 92806 USA USA and Canada Phone: 1.800.368.9700 Fax: 1.800.832.4888
How to secure your property after a disaster
How to secure your property after a disaster The Red Guide to Recovery HOuse secured properly Board-Up of Windows, Doors and Roof Hole. Lot secured with Perimeter Fencing. Fires, floods, tornadoes, hurricanes,
Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems
P O Box 34 Mendon, Utah Custom 30 x 20-8 Garage Plan Plan #g233 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical Section
Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars
Report on Wind Resistance of Signs supported by Glass Fiber Reinforced Concrete (GFRC) Pillars Prepared for US Sign and Fabrication Corporation January, 2006 SUMMARY This study found the attachment of
Chapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS.
Austin City Code - Volume II TITLE 25 LAND DEVELOPMENT\CHAPTER 25-12 TECHNICAL CODES\ARTICLE 1: UNIFORM BUILDING CODE\25-12-3 LOCAL AMENDMENTS TO THE BUILDING CODE Chapter 36 - STRAW BALE CONSTRUCTION
Embedded Parts Introduction - Anchors
In the plant construction or process plants such as chemical, petrochemical, gas or power plants various disciplines are brought into contact and built on each other. Civil, mechanical, electro technical
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER
Installation Instructions HighRock 4x4 TM
Installation Instructions HighRock 4x4 TM Slider Step Vehicle Application: Jeep YJ and TJ Wrangler 1986 2006 Part Number: 49312 www.bestop.com - We re here to help! Visit our web site and click on Ask
Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the A325 structural bolt. Rev.
Structural Bolting ASTM A325 and ASTM A490 are the two U.S. standard structural bolts. When looking at the mechanical requirements of bolts it appears that an ASTM A325 and SAE J429 Grade 5 are identical
MALONER. Installation & Loading Instructions - Please Read Before Beginning. Step 1: Installing Carriers to Cross Bars
SeaWing V-STYLE KAYAK CARRIER 60mm 50mm Rubber Plugs SeaWing Kayak Carriers 12 Load Straps Jawz Universal Adapters Mounting Bolts T-Knobs 12 Safety Lines MD Series Only Installation & Loading Instructions
AZEK Rail Install Guide
TRIM MOULDING DECK PORCH RAIL PAVERS AZEK Rail Install Guide Installing AZEK Rail with CableRail by Feeney... 1 Installing CableRail by Feeney for AZEK Rail... 7 Installing AZEK Rail Stairs with CableRail
Final inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
Installation Instructions
85-3976 rev. 05 08-13 Installation Instructions Thank you for purchasing this antisway bar kit. Please read through these instructions before installation. Rear Anti-Sway Bar Kit for Dodge Ram Pick-Up
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES
ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.
Formwork for Concrete
UNIVERSITY OF WASHINGTON DEPARTMENT OF CONSTRUCTION MANAGEMENT CM 420 TEMPORARY STRUCTURES Winter Quarter 2007 Professor Kamran M. Nemati Formwork for Concrete Horizontal Formwork Design and Formwork Design
OAK WORKBENCH WITH 2 DRAWERS
OAK WORKBENCH WITH 2 DRAWERS Model 93991 ASSEMBLY Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious injury.
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version
CEILING SYSTEMS Between us, ideas become reality Installing Suspended Ceilings North America Version 1 Installing Armstrong Suspended Ceilings An Armstrong suspended mineral fiber ceiling is functional,
Sun Vinyl New Construction Windows Homeowner's Warranty
Sun Windows Sun Vinyl New Construction Windows Homeowner's Warranty Vinyl Sun Windows, Inc. warrants for a period of 2 years that the quality of workmanship and materials of vinyl items shall be free from
PUMP JACK SYSTEM AND ACCESSORIES
Pump Jack Model # 2200 A low cost, easy to operate, safe, portable scaffolding built of rugged steel. It's perfect for shingling, siding, sheathing, insulating, painting, building, roofing, home repair
TracRac G2. Overhead Rack Installation Instructions. TracRac Inc. 994 Jefferson St. FallRiver MA 02721 www.tracrac.com 800-501-1587 IN-42000_B
IN-42000_B TracRac G2 Overhead Rack Installation Instructions TracRac Inc. 994 Jefferson St. FallRiver MA 02721 www.tracrac.com 800-501-1587 Thank you for your purchase of a TracRac G2 Sliding Cargo Manaagement
City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures
City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures SECTION 7201 - PURPOSE The purpose of this appendix chapter is to establish minimum prescriptive standards
R O A D M A S T E R, I N C.
R O A D M A S T E R, I N C. ROADMASTER, Inc. 6110 NE 127th Ave. Vancouver, WA 98682 6 13 11 MOUNTING BRACKET KIT Cable Tab 14 12 7 15 9 Cable Tab 360-896-0407 fax 360-735-9300 www.roadmasterinc.com ITEM
R O A D M A S T E R, I N C.
R O A D M A S T E R, I N C. ROADMASTER, Inc. 6110 NE 127th Ave. Vancouver, WA 98682 12 10 3 11 4 5 13 7 8 360-896-0407 fax 360-735-9300 www.roadmasterinc.com ITEM QTY NAME MATERIAL 1... 4...1/2 x 1 1/2
Vehicle Restraint Installation Manual
Vehicle Restraint Installation Manual SHR-5000 9 Carriage SHR-5000 12 Carriage MADE IN U.S.A. This Manual Covers Restraints Built After Serial Numbers: 4487000001 and up PRINTED IN U.S.A. RITE-HITE PRINT
Owner's Manual & Assembly Instructions
Owner's Manual & Assembly Instructions PM01 BASE KIT Model No. FDN1014 717090311 CAUTION: SOME PARTS HAVE SHARP EDGES. CARE MUST BE TAKEN WHEN HANDLING THE VARIOUS PIECES TO AVOID A MISHAP. FOR SAFETY
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
Digital Fingerprint safe
Digital Fingerprint safe Model 96846 Operation Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product
Chapter 6 ROOF-CEILING SYSTEMS
Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;
Wisconsin Building Products Evaluation
Safety & Buildings Division 201 West Washington Avenue P.O. Box 2658 Madison, WI 53701-2658 Evaluation # 200813-O Wisconsin Building Products Evaluation Material Best Management Standards for Foundation