Access Control DORMA. MasterCard XS Cylinder

Similar documents
PHA 2000 PHB 3000 EXIT PAD

SAFE-O-TRONIC access Door and furniture locking systems

ALWAYS THE SAFE CHOICE! Electronic door locking systems.

Ex15x //DATASHEET. Xs4 Mini. Cutting-edge design + Amazing technology:

Shunt lock function 3066

Cam-action door closer. DORMA TS 90 Impulse

EM Hold-open magnets

How To Fit A T.V Door Closer

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

Installation manual. Version

Machine devices, jig devices

bts 80 f/emb/flb/bsr Floor spring system

ES 200. Sliding door operator

Creation of Waferlock

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

Products for Effective Asset Management

LockerLock Schließgehäuse LockerLock lock case Boîtier de fermeture LockerLock Scatola di ciusura LockerLock Caja de cierre LockerLock

Series 300 / 200. Mortice locks for timber doors

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

ELECTRONIC LOCKING SYSTEMS

Electric Rotary Actuator - On/Off or programmable control actuator

BUSINESS. Elektronisches Türschloss. Installation and User Manual. Ingeniously safe. Ingeniously simple.

Sliding and Folding Door Fittings Sliding Door Accessories

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

P10 - Standalone Access Controller and Reader

Incubator with mechanical convection

K17.12 Door closers K17. Doors

Combi switchbox with integrated 3/2 way pilot valve

PROXIMITY CARD READERS C-10, C-20, C60, C70

Material test chamber with mechanical convection

BRICK LED Design Ronni Gol

FIREDEX Conventional Fire Panels

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

ELM Security System Electronic Locking & Monitoring

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Narrow stile lock 1314

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

SOLAR. Energizer Systems NEW S10 ENERGIZER NOW AVAILABLE

Access control and traffic bollards. Access control and traffic bollards

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

Universal systems for frameless doors

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS

product brochure IMPLEMENTED

A C C E S S C O N T R O L S Y S T E M

video door entry system offer

Design + Security isis M100 security fittings Security fittings Security fittings for frame doors Security roses Security roses, flush fit

Digital display DA 48

D.A.C.S. Door Access Control System

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Contrast 2 LED. Performance Compactness Complete flexibility NEW

Turbine Flow Sensor Series VTR

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

ABLOY EL460, EL461, EL560, EL561 Europrofile handle controlled locks


DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

SR Door co-ordinators

BIS Metal Pipe Clamps with Lining

Cable Plug acc. to DIN EN , Form A

ABLOY EXIT. Functional and technical descriptions Single and double leaf doors. An ASSA ABLOY Group brand

SCHMIDT ManualPress 300 Series Manual Presses with Process Monitoring

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

Digital Keypad Use s Manual

NiceWay. Professional For a more professional and practical use, the system can be programmed by means of the handy Nice palmtops.

Heating oven with mechanical convection

Series 8146/5-V37 and Series 8150/5-V37

Digital inductive conductivity transmitter

Easy-action Door Closer DORMA TS 83

08. SEK IDC CONNECTORS

DIGITUS Network & Server Cabinets. UNIQUE Series

BIOMEDICAL REFRIGERATORS

DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button

Magnetic proximity switches

Thickness Gauges. convex R 15 or R 40, flat 10 mm Ø, spherical

Modular and Flexible. We want to make it easier for you! Innovative Riveting System. with blind rivet adapter BR 20. with blind rivet adapter BR 50

Cards & Card Hardware

Padlocks. 146 Padlocks FEATURES

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

HERZ-Thermal Actuators

BLADE S-MAX Cabinet for Blade Server

ABLOY EL420, EL520 Europrofile motor locks

Data Centre Solutions

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION SECURITY AND ACCESS CONTROL SYSTEM

Transponder reader CÉLIANE TECHNICAL GUIDE

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

WIRELESS STATUS MONITOR

NoteLocker 8 NoteLocker 8 as a Floor-standing Solution

6 LED colours: White Blue Green Red Yellow Amber

EasyStart R + Operating instructions. Comfort radio remote control with integrated timer for parking heaters and more.

Pay and Display Ticket Machines

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

USER MANUAL. KIT VIDEO DOOR PHONE 2 smart 1 family

Troubleshooting: Door Jamming and Door Handing 6. Troubleshooting: Keypad 11. Troubleshooting: Battery 12. Battery FAQ 13

Secure Keypads for access control

Transcription:

Access Control DORMA MasterCard XS Cylinder

DORMA MasterCard XS Cylinder Access Control DORMA MasterCard XS cylinder the multi-talent access control solution The DORMA XS cylinder is a universally applicable, battery-operated lock actuator comprising a reader module, a europrofile cylinder adapter and a mechanical knob. The reader electronics and the mechatronic coupling system are installed together with the batteries inside the reader module. Combination of the XS cylinder reader module with a cylinder adapter converts conventional locks prepared for europrofile cylinders into an access control system without the need for major installation work. The XS cylinder can thus be used as a costefficient solution for both new projects and for existing buildings. The user IDs can take the form of various transponder media such as ISO cards, fobs, watches, etc. Technical specifications: DORMA MasterCard XS cylinder Dimensions Reader module: 40 mm dia, length 41 mm Knob: 29.5 mm dia, length 20 mm 34.0 mm dia, length 20 mm Europrofile cylinder adapter: 25/25 mm up to 50/60 mm Door thickness (incl. fitting): 40 to 120 mm Power supply: Lithium batteries type CR-2, 3V Battery life: approx. 25,000 operations, up to 10 years Battery low/change indicator: Yes Emergency power supply: Possible Operating temperature: 25 C to 65 C Class of protection: IP 67 Application locations: Indoor and outdoor No. of access authorisations: max. 99 Access mode: Non-contacting with proximity ID card or fob featuring HITAG 1 transponder The main advantages at a glance 2 Easy to install, no drilling necessary 2 No chasing, cabling or wiring work 2 Suitable for all europrofile cylinder locks 2 Modular design for minimal investment outlay 2 Easy MasterCard programming 2 Secure access control with personalised ID media XS-KL XS-PZ XS-CM 20 41 l 34 20 25 25 l 29,5 l 40 XS-KS min. max.* 50 60 *Other lengths on application 2

DORMA MasterCard XS cylinder the modular construction kit External Internal Reader module, opened to show batteries and control unit Knob or reader module Reader module cap Cylinder adapter The requisite cylinder adapter dimension can be determined either by measuring the europrofile cylinder located in the door or by measuring the door and fitting thicknesses. This will provide you with lengths L1 and L2, which you can then compare with the cylinder adapter dimensions in the table. Note: In order to avoid presenting areas susceptible to mechanical attack, the cylinder adapter should be as flush as possible with the door fitting. We recommend that the projection on the outside of the door be no more than 2 millimetres. min. 50 max.110 L1 L2 3

DORMA TS MasterCard 93 XS Cylinder Access Gleitschienen- Control Türschließersystem Specification text Order No. b XS-CM reader module Reader module for XS cylinder, MasterCard model, for access control on doors. The reader module detects proximity ID cards or transponder fobs of the type HITAG 1. Up to 99 ID cards or transponder fobs can be authorised for operation in conjunction with the electronic XS-CM reader module. Where required, authorisations can be provided with a permanent-open enable function, allowing the door to be opened in the morning and locked at night. The XS MasterCard cylinder is designed as a learn-delete system. The ID cards or transponder fobs to be authorised can be read in directly at the door. Programming is performed by holding the programming card at the reader and presenting the ID devices at the reader module that are to be authorised or deleted. Lost ID cards or transponder fobs can also be deleted from the reader module using the programming card. All ID cards and transponder fobs are unique entities. The use of XS cylinders enables implementation of a wide range of master key concepts in line with given or changing circumstances. For added protection against tampering/manipulation, the reader module may only be removed and the battery changed on the basis of corresponding authorisations. Operating conditions are visually and audibly signalled. The modular kit concept enables installation in a wide range of different door thicknesses and satisfaction of various access control requirements. Finish: mock stainless steel/end face black Dimensions: 40 mm dia., length 41 mm In addition to the XS-CM electronic reader module, the following components will need to be ordered separately for the access side: XS-PZxx XS cylinder adapter, XS-CBP XS battery pack, XS-Kx mechanical XS knob or additional electronic reader module for the interior. XS-CM pack of 1 19020004 XS-CM pack of 10 19030004 b XS-CM CODIC CARD ID card CCH-0x Card with passive HITAG 1 transponder for personalised identification of authorised personnel. Each card is a unique entity. Can be used in conjunction with other systems operating with HITAG 1 technology, e.g. for individualised canteen billing. Dimensions (W x H x T) 85 x 54 x 0.75 mm Y CCH-01 two-colour print on one face with CODIC CARD inscription 19175001 Y CCH-02 blank 19175002 b CCH-Ox CODIC CARD transponder fob CTH-03 Key fob with passive HITAG 1 transponder for personalised identification of authorised personnel. Each fob is a unique entity. Can be used in conjunction with other systems operating with HITAG 1 technology, e.g. for individualised canteen billing. Typical reading distance 3 cm Dimensions (W x H x T) 30 x 45 x 1.5 mm 19175003 b CTH-03 4

Specification text Order No. b XS-Kx knob Mechanical knob with recessed grip for combination with XS cylinder components. Finish: mock stainless steel XS-Kx pack of 1 Type Diameter XS-KS 29.5 mm 19180104 XS-KL 34.0 mm 19180204 b XS-K XS-Kx pack of 10 Type Diameter XS-KS 29.5 mm 19180304 XS-KL 34.0 mm 19180404 b XS-K XS-CBP battery pack Battery pack comprising 2 single CR2 lithium batteries for fitting to an XS reader module. XS-CBP pack of 2 19154000 b XS-CBP XS-CBC battery change tool Battery change tool for easy battery change in XS reader modules. XS-CBC pack of 5 19154001 b XS-CBC 5

DORMA MasterCard XS Cylinder Access Control Specification text Order No. b XS-PZxx cylinder adapters Cylinder adapters for combination with XS cylinder components. Suitable for non-directional installation in europrofile (PZ) type locks according to DIN 18254. Modular range from 25/25 mm to 50/60 mm; other dimensions on application. Cylinder adapter lengths will need to be specified in accordance with the details of the door concerned and the selected fittings. XS-PZxx pack of 1 Type Dimensions XS-PZ 01 25x25 19160101 XS-PZ 02 25x30 19160102 XS-PZ 03 25x35 19160103 XS-PZ 04 25x40 19160104 XS-PZ 05 25x45 19160105 XS-PZ 06 25x50 19160106 XS-PZ 07 25x55 19160107 XS-PZ 08 25x60 19160108 XS-PZ 09 30x30 19160109 XS-PZ 10 30x35 19160110 XS-PZ 11 30x40 19160111 XS-PZ 12 30x45 19160112 XS-PZ 13 30x50 19160113 XS-PZ 14 30x55 19160114 XS-PZ 15 30x60 19160115 XS-PZ 16 35x35 19160116 XS-PZ 17 35x40 19160117 XS-PZ 18 35x45 19160118 XS-PZ 19 35x50 19160119 XS-PZ 20 35x55 19160120 XS-PZ 21 35x60 19160121 XS-PZ 22 40x40 19160122 XS-PZ 23 40x45 19160123 XS-PZ 24 40x50 19160124 XS-PZ 25 40x55 19160125 XS-PZ 26 40x60 19160126 XS-PZ 27 45x45 19160127 XS-PZ 28 45x50 19160128 XS-PZ 29 45x55 19160129 XS-PZ 30 45x60 19160130 XS-PZ 31 50x50 19160131 XS-PZ 32 50x55 19160132 XS-PZ 33 50x60 19160133 XS-PZ S Special custom lengths on application 19160139 b XS-PZ 6

XS MasterCard cylinder how it works: The XS MasterCard cylinder is designed as a learn-delete system. The ID cards or transponder fobs to be authorised can be read in directly at the door. Three authorisation cards are required for programming, battery changing and equipment modifications. The first card to be presented to the reader module is the MasterCard, the second is the BatteryCard and the third is the ModificationsCard. In order to activate or delete the access authorisations, the programming card (XS MasterCard) needs to be held at the XS cylinder. The reader module invokes the programming mode and the ID medium can then be authorised or deleted. The XS cylinder has two functional operating positions: engaged and disengaged. In the disengaged condition, the reader module ( electronic knob ) rotates freely without operating the lock cam. Presentation of an authorised ID medium engages the cam. Now, as the reader module is rotated, the cam is operated and actuates the latch and/or bolt in accordance with the type of lock concerned. The cylinder operating status is visually and audibly signalled at the reader module. Programming 2 1 3 = Authorised = Unauthorised = Green LED = Red LED = Acknowledge signal Battery change 2 3 1 4 5 6 Modification 1 2 3 4 5 6 7

www.dorma.com Door Control DORMA GmbH + Co. KG Breckerfelder Str. 42 48 D-58256 Ennepetal Tel.: +49 23 33/793-0 Fax: +49 23 33/7 93-495 The address of a subsidiary/ representation in your area you can find at the DORMA website: www.dorma.com Automatic Glass Fittings and Accessories Security/ Time and Access (STA) Movable Walls WN 052 948 51532, 11/05, XS-Zylinder, D, x. xx. 11/05 Subject to change without notice