ELECTRIC CENTRAL HEATING FLOW BOILER

Similar documents
ELECTRIC CENTRAL HEATING FLOW BOILER

ELECTRIC INSTANTANEOUS WATER HEATER

Electric Flow Boiler

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Portable Air Conditioner

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

User Manual THR840DUK Digital Thermostat

For installation guide see reverse of book

RRV934. Multi-controller. Synco living

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

1 General information

Aerona Air Source Heat Pumps

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Contents. Introduction

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

GSM HOME SECURITY SYSTEM

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

ECOCIAT. Domestic hot water heat recovery unit

KRONOS GA11 WEEKLY-PROGRAMMING DIGITAL CHRONOTHERMOSTAT FOR THE REMOTE CONTROL OF HOT AIR GENERATORS THROUGH BRAHMA INTERFACE BOARD APPLICATION

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

REMOTE CONTROL MANUAL

A Class Air Source Heat Pump User Guide

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Please also see 10 golden rules for correct Saniflo installation on

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Smile. The All-In-One Heating Controller

Drayton Digistat +2RF/+3RF

INSTALLATION & TECHNICAL MANUAL

ECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions

Product and Application Description

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Use and Care Manual. Model CPA12KH AIR CONDITIONER

evohome Wireless Radiator Zoning Kit Installation & User Guide

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Heating Controller. Building Technologies HVAC Products

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

User's Instructions. Alpha HE CB25/33 and HE SY25

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

SF15K SF05KSS, SF10KSS

HERZ-Thermal Actuators

PART 11: START-UP PROCEDURES FOR THE INSTALLER

USER S MANUAL HSC-24A

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

IH E Sigma Island 90

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

SWIMMING POOL HEAT PUMP Owners Manual

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +

HEAVY DUTY STORAGE GAS

User manual. 086U6297 Rev. 9 EN

How To Use A Power Supply On A Powerline 2.2 (Ai)

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Daikin Altherma Hybrid Heat Pump

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

Operating instructions

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Air Source Heat Pump Installation and Maintenance Manual

Table of Contents. 1 - Specifications Installation Wiring User controls...7

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

LK Electric Boiler - 4,5

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Overheating limit control

Daikin Altherma Hybrid Heat Pump

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Oil and Coolant Circulating Heating System. Model - OCSM

PANASONIC TROUBLE SHOOTING GUIDE

COMMISSIONING OF HVAC SYSTEMS

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Split Controller. User Manual SM-SS-F 2009/01/04

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Digital timer thermosatat. isense. Installation and Service Manual AG

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Installation instructions. For the competent person. Installation instructions. VRT 350f. VRT 350f GB, IE

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

ACS-30-EU-EMDR-10-MOD

LIEBERT VNSA Installation Sheet

Transcription:

ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.M1z EKCO.M1Nz EKCO.TM

Contents Safety instructions 3 Basic information about the boiler 3 Instruction for the installer Technical Data 4 Installation of the boiler 4 Connecting external appliances to the ZIO module 7 Boiler in cascade connection 9 External mode switching 10 Front control panel introduction 11 Main view 11 Choosing the display view 12 Selecting the language version 13 Boiler nad DHW Cylinder configuration 13 Outdoor temperature compensation 14 Automatic summer mode 15 Working modes 16 Automatic work with 24H Temperatures, weekly programming 16 Pump working mode 18 Current time setting 19 Room temperature sensor 19 DHW Pump 20 DHW cylinder 20 Heating of the second circuit 22 Central heating parameters view 22 Faults 23 Service menu 23 Boiler in cascade connection 25 GSM remote control 26

Safety instructions 1. Please read and follow the Installation and Operating Instructions carefully, to ensure the long life and reliable operation of this appliance 2. The boiler installation and all electrical connections must be made by an qualified person. 3. Manufacturer may make minor changes, if necessary in the appliance that will not be shown in the operating instructions, so long as the main features of the boiler remain the same. 4. The Control Panel is pre-set by the manufacturer so it is ready to be operated, however you can adjust the manufacturer settings to your individual requirements. Appropriate programming ensures comfortable and economical operation of the boiler. 5. It is necessary to cut off all power supply using either the boiler switches or switching off the fuse prior to removing the boiler front casing. 6. Do not drain the water from central heating system after the heating season. 6. It is necessary to cut off all power supply using either the boiler switches or switching off the fuse prior to removing the boiler front casing. 7. In buildings were the boiler is operated only on temporary basis and the heating installation can be exposed to frost, the boiler must be operated at all times using anti-freeze mode, or the heating installation must be protected using an anti-freeze liquid. Basic information about the boiler The provided installation and operating instructions refers to the following boiler types: EKCO.M1z, EKCO.M1Nz, EKCO.TM hanging electric boiler, single-functional, with the weather compensation, enable to co-operate with one or two central heating circuits (e.g. radiators and under-floor heating), with the DHW cylinder and the central heating flow pump. The boilers mentioned above shall be operated on a closed (unvented) central heating installation with a forced water circulation, protected in accordance with the binding norms and standards. The boilers can also work on opened (vented) central heating installations with forced circulation protected in accordance with the binding norms and standards. They are equipped with a front control panel, which takes into consideration current outdoor temperature. This feature ensures an almost automatic operation of the boiler. Accurate setting of the heating parameters ensures economical operation of the boiler. The boiler is equipped with a circulating pump, a manometer and an automatic vent valve. The boiler is also equipped with a number of other safety de vices: flow control system, inner temperature sensor, temperature cut-out and safety valve. The power of the boiler should be adjusted according to the heat loss of the heated building. PL-015B/f. 3

Technical data Maximal pressure MPa 0,3 Minimal pressure MPa 0,05 Outflow water temperature C 20 85 Max. water temperature C 100 Dimensions (height x width x depth) EKCO.M1z 660 x 380 x 175 EKCO.M1Nz mm 700 x 425 x 285 EKCO.TM 815 x 503 x 197 EKCO.M1z ~16 Weight EKCO.M1Nz kg 24,5 EKCO.TM ~29 Water connections EKCO.M1z, EKCO.M1Nz G 3/4 EKCO.TM G 1 Safety class IP 21 Rated power kw 4 6 8 4 6 8 12 Rated voltage 230V~ 400V 3N~ Rated current A 17,4 26,0 34,8 3 x 5,7 3 x 8,7 3 x 11,7 3 x 17,3 Fuse rated current A 20 32 40 10 16 20 Minimal connecting wires diameter mm 2 3 x 2,5 3 x 4 3 x 6 5 x 1,5 5 x 2,5 The maximum allowed network impedance Ω 0,44 0,39 0,34 Rated power kw 15 18 21 24 30 36 42 48 Rated voltage 400V 3N~ Rated current A 3 x 21,7 3 x 26,0 3 x 30,3 3 x 34,6 3 x 43,3 3 x 52,0 3 x 60,6 3 x 69,3 Fuse rated current A 25 32 40 50 63 80 Minimal connecting wires diameter mm 2 5 x 2,5 5 x 4 5 x 6 5 x 10 5 x 16 Maximal connecting wires diameter EKCO.M1z, EKCO.M1Nz mm 2 EKCO.TM 5 x 16 phase conductor (2 x 16 each), neutral and protective conductor (1x16) The maximum allowed network impedance Ω 0,14 0,09 0,035 0,03 Installation of the boiler Installation conditions appropriate power supply, faultless electric installation in accordance with the binding standards, wet central heating system equipped with an expansion vessel: the heating installation needs to be flushed thoroughly before the installation, the boiler must be protected from dirt by using a magnetic filter, do not install any barrier fittings (e.g. valves) on the outlet of the safety valve, this appliance must not be installed in a humid place or in a place exposed to the danger of explosion, if the boiler is to co-operate with an under-floor heating protecting fittings must be installed (fig. 2b or 3). A filter must be installed on return pipe-work of central heating installation (before boiler inlet). The filter must be installed in horizontal position accordingly to the arrow that shows a flow direction. 4 Instruction for the installer

Installation work 1. Hang the boiler up in a vertical position on fixing screws with inlet and outlet pipes to the bottom, maintaining clearances from the walls and the ceiling (see fig.1). 2. Connect the boiler to a central heating system equipped with cut-off valves (see fig.2 & fig.3). 3. Fill the central heating system with a treated water, that extends the life of the heating elements. 4. Vent the central heating system. 5. Connect a boiler to the electrical system (see fig. 4). 1a EKCO.M1z Note Central heating system The control panel in the EKCO.TM boiler allows for its co-operation in different central heating systems, however the control panel needs to be set accurately (see Front control Panel Service Settings ). e.g. if the boiler only co-operates with an under-floor heating system, a Tcomax (max. central heating medium temperature in the central heating system) must be set at 60 C and WCHG (radiator coefficient) at Pod (see Extended Menu on page 24). inlet outlet 1b Special start-up procedure (refers to the EKCO.TM model only) A flow rate reading error may occur if you start-up the unit at low ambient temperature. This error may occur because the physical properties of antifreeze solution. Under this circumstances, the special start-up procedure will start if you: - activate the central heating or cylinder heating mode using the control panel display (see fig.14), - close the NA input in ZIO board (see fig.6), - notice the! (an exclamation mark) at main view panel display (see Faults page 12) As a result, the medium will be warmed up to temperature that enabled you to read the flow rate correctly. The duration of procedure depends on both the installation capacity and the temperature inside the system. When the main view panel display (fig.10, 11) and the central heating parameters view (fig. 31) shows boiler power value and ( -, -- ) alter-nately it means that the procedure is started. The procedure will close automatically and the unit will start normal operation once the minimal flow rate is reached. inlet inlet EKCO.M1Nz outlet EKCO.TM outlet 1c Fig.1a, 1b, 1c Fixing the boiler to the wall. PL-015B/f. Instruction for the installer 5

a) b) 2 Tzew - outdoor temperature sensor Tpok - room temperature sensor ZP - straight-through valve ZT - thermostatic valve ZO - air-vent valve ZRC - relief valve NW - expansion vessel RW - expansion pipe F - magnetic filter ZK - cut-off valve Tzew - outdoor temperature sensor Tpok - room temperature sensor NW - expansion vessel RW - expansion pipe F - magnetic filter ZT - thermostatic valve ZK - cut-off valve Fig.2 Exemplary scheme of central heating system a) - radiators system (one heating circuit) b) - under-floor heating system (one heating circuit) 3 Pc.w.u - circulation pump F - magnetic filter NW c.o. - central heating expansion vessel NW c.u.w.- DHW expansion vessel RW - expansion pipe ZB - safety valve ZK - cut-off valve ZO - air-vent valve ZP - straight-through valve ZT - thermostatic valve ZZ - non-return valve c.w.u. - Domestic hot water (DHW) PO - circulation pump Tco2 - sensor of the medium temperature in the second circuit TPO - circulation pump thermostat Tpok - room temperature sensor Tzas - thermostat or cylinder temperature sensor Tzew - outdoor temperature sensor ZAS - DHW cylinder with a heating coil ZTD - three-way valve ZM - three-point mixing valve Z.W. - cold water Fig.3 6 Exemplary scheme of central heating system radiators, under-floor heating, DHW cylinder, DHW circuit. Instruction for the installer

4 Fig.4 Connection to the electric mains Electric installation should be equipped with residual current protective devices and other solutions which will ensure disconnecting the unit from the source of power (intervals between all their poles should not be less than 3 mm). 5a 5b N L N L Fig.5a Connection of the EKCO.M1z to the three phase system. PNL - points of neutral and protective conductor connection PF - points of phase conductors connection [6] - temperature limiter Fig.5b Connection of the EKCO.M1z to the single phase system (for boilers of 4kW,6kW and 8kW) PNL - connection points of neutral, protective and phase conductor [6] - temperature limiter [15] - wire set Note: 4, 6 and 8kW boilers are factory pre-set to work as single phase boilers [figure 5b]. If you intend to connect the boiler to a three-phase installation, take off the [15] wire set. Connecting external appliances to the ZIO module A number of other appliances or necessary sensors (fig. 6) can be connected to the boiler according to the individual requirements. The temperature sensors should be connected using a LIYY 2x0,14 or similar type of wire. Pay special attention to the sensors ending, incorrect wiring may result in short circuit. The connecting wire lengths must be limited. A long wire may cause interference and faulty sensor operation. The wires must not be run in the same conduit with (or too close to) electrical wiring, and must not be wrapped around any other wires or cables. The sensor location is essential for its proper functioning. Outdoor temperature sensor should be installed in the coolest place in the building (north building side), relatively far away from heat source (e.g.windows that can be opened, ventilation ducts, chimneys and other heated surfaces). Do not install the outdoor sensor in the place exposed to direct sunshine. Indoor temperature sensor must be located inside the building, in the most commonly used room, relatively far away from windows, radiators, doors and other places that may have affect on correct temperature measuring. The indoor temperature sensor is optional accessory. For more information about sensor see page 19 - Room temperature sensor. PL-015B/f. 7 Instruction for the installer

Connecting external appliances to the ZIO module A number of other appliances or necessary sensors (fig. 6) can be connected to the boiler according to the individual requirements. The temperature sensors should be connected using a LIYY 2x0,14 or similar type of wire. Pay special attention to the sensors ending, incorrect wiring may result in short circuit. The connecting wire lengths must be limited. A long wire may cause interference and faulty sensor operation. The wires must not be run in the same conduit with (or too close to) electrical wiring, and must not be wrapped around any other wires or cables. The sensor location is essential for its proper functioning. Outdoor temperature sensor should be installed in the coolest place in the building (north building side), relatively far away from heat source (e.g.windows that can be opened, ventilation ducts, chimneys and other heated surfaces). Do not install the outdoor sensor in the place exposed to direct sunshine. Indoor temperature sensor must be located inside the building, in the most commonly used room, relatively far away from windows, radiators, doors and other places that may have affect on correct temperature measuring. The indoor temperature sensor is optional accessory. For more information about sensor see page 19 - Room temperature sensor. Master appliance (NA entry) you can limit the boiler electricity consumption by connecting the master appliance (e.g. instantaneous water heater) see fig.6. The master appliance must be equipped with the relay output. The output should be connected to the NA input in the ZIO board by using LIYY 2 x 0,14 or similar type of wire. Do not connect any voltage to NA input! Use an appropriate relay if the master appliance can control the voltage signal only. NA input must remain closed if not used! 6 U1 - master appliance Tzas - DHW Cylinder temperature sensor (WE-008) Tco2 - second heating circuit temperature sensor (WE-008) Tzew - outdoor temperature sensor Tpok - room temperature sensor U3 - DHW Cylinder thermostat U2 - device for night or antifreeze work mode Total output current < 2A U+ - valve supply - 230V (open/heating) U- - valve supply - 230V (close) N - neutral conductor U - pump supply - 230V N - neutral conductor PE - protective conductor PE - protective conductor N - neutral conductor U - pump supply - 230V LB - valve supply of B circuit (DHW Cylinder) LA - valve supply of A circuit (central heating system) N - neutral conductor ZTM three way mixing valve (under-floor heating or second heating circuit) PUMP A2 - second circuit pump CWU - DHW pump ZAS - three-way switching valve (DHW Cylinder) Fig.6 Connecting external appliances to the ZIO board. Please refer to the appropriate section of this manual for ZIO board work details. DHW temperature reading Controller can measure a water temperature for: a) cylinder thermostat equipped with a free voltage output. b) cylinder temperature sensor (WE-008 offer by Kospel S.A.- optional equipment) Set the Extended Menu for option a or b. For thermostat contacts and cylinder sensor connection details see fig.6. 8 Instruction for the installer

Three-way valve connection (DHW Cylinder) There is a ZAS connector on ZIO22 board. (fig.6, page 8). If there is a need to heat-up the water in the DHW cylinder the LB contact is fed at 230V. In the case of boiler heat the water in the central heating system the LA contact is fed from 230V supply. You can connect a three-way valve to the ZAS connector to switch the central heating system circuit for DHW, if necessary. In the case of DHW heating the outlet temperature is set at 80 0 C (standard set point). You can lower the outlet temperature by setting the Extended Menu.Kospel recommends to use the VCZ- MH6000E three-way valve with the VC6012ZZ00 servo-motor and the 45900445-013B wire. The three-way valve work is controlled by supplying voltage of 230V to either brown or black wire. The blue wire must be connected to the terminal of neutral conductor N. If you use the brown wire you will open the port between AB inlet and B outlet. If you use the black wire you will open the port between AB inlet and A outlet. See valve body for the inlet and outlet marking. Fig.6 shows the three-way valve connection diagram. Connection diagram is based on the following assumptions: the boiler hot water outlet is combined with the AB inlet of valve. A and B outlets function: A - supplying of central heating system B - supplying of DHW Cylinder. In this configuration you must connect: - black wire of 45900445-013B cable to the LA terminal (in ZIO board) - brown wire of 45900445-013B cable to LB terminal (see fig.6) - blue wire of 45900445-013B cable to the N terminal(see fig.6) DHW pump The boiler is able to control DHW pump. The pump operation can be set to meet the individual needs (24hours program). The pump should be connected to ZIO board as shown in fig.6 (page 8). The pump is fed from 230V supply. Connecting the three-way mixing valve of the second circuit. The ZTM contacts of ZIO22 board enables to connect the mixing valve with 3 point drive to feed the second heating circle (fig.3 ZM valve). This circle must be attuned to the lower parameters than the circle of the boiler e.g. when the circle of the boiler is set for the maximum temperature of 85 0 C (see the Extended Menu for WChG,WChG2, Tcomax i Tc2max parameters), the second circuit can feed the underfloor heating system with the maximum temperature of 60 0 C. In this case it is necessary to remember that the extra safety devices has to be installed to prevent the overheating of the second circle. The WE-008 sensor measures temperature of the second heating circle. Boiler in cascade connection You can connect number of boilers to increase power. The maximum number of slave unit (EKCO.L1z or ECKO.T) in cascade is 8. The slave unit must be equipped with a special controller to enable cascade connection. For hydraulic connection details see fig.7a. 7a Tzew - outdoor temperature sensor Tpok - room temperature sensor ZP - straight-through valve ZT - thermostatic valve ZO - air-vent valve ZZ - non-return valve NW - expansion vessel RW - expansion pipe F - magnetic filter ZK - cut-off valve Fig.7a Boiler in cascade connection PL-015B/f. Instruction for the installer 9

To set the EKCO.M1z / EKCO.TM to work in cascade change the Nr parameter in the Extended Menu for a required number of slave boiler. To set the EKCO.L1z or EKCO.T to work in cascade the Extended Menu settings have to be changed: a) set for r1 b) set up the unit address e.g. A1 The boiler address is a number that inform about the boiler in the network connection. Each boiler has its own address. The address number can not be higher than number of slave boilers. For example: if you build boilers cascade system with the EKCO.M1z/EKCO.TM (as a master appliance) and three other boilers (as a slave appliances), the slave appliance should have the following addresses: A1, A2 and A3. The boilers must be connected into the mains (use e.g. LIYY 2 x 0,14 wire). See fig.7b. PSK.P4 Controller 7b for the next boilers Fig.7b Additional electrical connection for boilers in cascade The boilers must be connected in the row. External mode switching There is RP input on ZIO board. Close the RP input if you need to switch to antifreeze or night time operating mode. Set-up the Extended Menu to select mode. Do not connect any voltage to RP input! This input enable connecting of external controller with the relay output and simplified boiler controlling by mobile phone. 10 Instruction for the installer

Front control panel introduction There is a control panel (fig.8) that enable user to boiler control. Tu 8 Fig.8 Control panel 1 - display 2-7 - push-buttons When you switch boiler on, the controller gets reset (fig.9) and the display will show you the software number. +GSM symbol informs that the boiler is equipped with GSM module. 9a 9b 84 Fig.9a Main view Controller reset (EKCO.M1z) Fig.9b Controller reset (EKCO.TM) After the reset operation, the controller automatically switches to the Main View. Main view can display a configuration as below (depend on current mode). For more details about the boiler configuration see page 13 Boiler and DHW Cylinder configuration The boiler can co-operate with both the central heating circuit and DHW Cylinder or any of them individually. Fig.10 Main view in configuration C.0.TAK ZAS. 10 Mo TAK ( Central heating mode on and DHW mode on ) or C.O.TAK ZAS.NIE (central heating mode on and DHW mode off ) If the Central heating mode is on the main view displays information as shown in fig.10. I row current time and day - GG:MM DT and current work ing mode (see page 16 Working mode ). Working mode marks: PX 24h program X (e.g. P0 program no. 0), after an equal sign (=) you can read a daily temperature. For temperature programs details see page 16 Automatic working mode (daily, weekly programs) antifreez - anti-freeze program manp5 - program no 5 (fixed outlet temperature) man+ - fixed daily temperature program + (higher) man - fixed daily temperature program (lower) man* - fixed daily temperature program man ( - fixed night temperature program II row - current outdoor temperature III row - current room temperature, after (- ) you can read a desire temperature IV row current boiler inlet temperature, after (- ) you can read a set-point of outlet temperature. At the bottom right corner you can read current boiler power (kw) or special start-up procedure mark (see page.5) PL-015B/f. 11

11 Fig.11 Main view in configuration central heating mode off and DHW mode on If the CH mode is off and the DHW mode is on the main view displays information as shown in fig.11 I row - HE mode (DHW mode). The power is shown only, when the DHW heating is on In the last row you can see: TZ mark - DHW heating mode is on. 12 Fig.12 Main view in configuration central heating mode off and DHW mode off If te both the central heating mode and the DWH mode is off the main view displays information as shown in fig.12. Faults Main view shows some information about faults.!! - sensor failure.?? - transmission failure between controller and sensor or an extremely high temperature sensor reading (over 45 0 C), e.g. when the sensor is placed in direct sunshine. - - room sensor missed. It s not an error as room sensor is optional equipment. Main view can show! mark that inform you about flow failure. This failure is only possible when the circulation pump is active. Display view settings There are push buttons (see fig.8) on control panel to set the display view and parameters. After 30 seconds (if you don t use any button) the display view automatically returns to the main view and the back light turns off. is an exit key enables to return to the previous view or to the main view. If you are in the main view use an appropriate push button to access to the next page: to the daily modes, to the central heating parameters view & to other pages. Press to go to: Mode Configuration Time Edit Curve Tp - Hysteresis Maximum Tz Central heatingpump DHW pump DHW Cylinder (1) DHW Cylinder (2) Central Heating Circuit #2 Errors Extended menu Week mode ABC Daily mode GSM (+GSM) Press to return to the previous page. 12

Language version To change the language menu go to the ABC page. The menu is available in the following languages: Polish English Russian (optional) French 13 Fig.13 Language page save language version return to the previous page select language version select language version Boiler and DHW Cylinder Configuration Boiler can co-operate with both the DHW Cylinder and central heating system. Configuration page is shown in fig.14 14 Fig.14 Configuration view C.O. YES CH on C.O. NO CH off H.E. YES DHW Cylinder (Heat Exchanger) on H.E. NO - DHW Cylinder (Heat Exchanger) off To change configuration press or. save changes return to the previous page on/ off central heating circuit on/off DHW heating Important! Make sure you save your changes by pressing button. PL-015B/f. 13

Outdoor temperature compensation The main function of PSK.M3 Controller is to maintain the proper CH medium temperature level in relation to outdoor temperature. Heat demand of building rises quickly with the dropping outdoor temperature. The exemplary relationship between the outdoor temperature and the temperature of CH medium is shown in fig.15. 15 Fig.15 Heating curve. N - the slope of a curve Tc - temperature of CH medium Tz - outdoor temperature Tp - room temperature The heating curve is loaded into memory of controller. Tp axe can be used to move the curve to the desired room temperature. The fig.15 shows the group of heating curves for different N parameters and the room temperature of 20 0 C. The slope of the curve (N) depends on heat loss of building. When the building is well isolated the N parameter will be accordingly low and vice versa. The N parameter is factory pre-set to value of 14 and should be appropriate for the majority of nowadays buildings (radiators heating). For the under floor heating the recommended value is 8. Setting the heating curve To set N value go to Edit page (see fig 16). The N value range is 4-25. Example: The factory preset value of 14 informs that CH medium temperature reaches 20 C degree (Tpok = 20 C) when Tc =76 C and Tzew = 20 C. Increase the N value if the room temp. is too low. Reduce N value in the case of rooms overheating. For more information about N value refer to section Heating curve view (fig.17, page 15). To change N value press or. 16 Fig.16 Heating curve edit page. The display shows the calculated value of heating medium in the current outdoor temperature mode. This value is calculated from the 24 hour temperature. For more information about the 24 hour temperature value and others temperature values refer to the next pages. Important! Make sure you save your changes by pressing button. Push-buttons specification: save changes return to the previous page increase N value decrease N value 14

Heating curve view To change Tz value press or. The controller calculates the temperature of CH medium on the basis of daily temperature and N value. 17 Fig.17 Heating curve Push-buttons specification: exit key to the Main view not applicable previous page next page outdoor temperature increase outdoor temperature decrease Automatic summer mode The Maximum Tz page (fig.18) enables to set the outdoor temperature limit value. Reaching or exceeding the limit value will automatically off boiler operation. Important! Make sure you save your changes by pressing button. 18 Fig.18 Outdoor temperature limit Push-buttons specification: save changes return to the previous page increase max. Tz value decrease max. Tz value PL-015B/f. 15

Boiler working mode The Mode page enables to set an appropriate working mode of the boiler (see fig.19). 19 Fig19. Working mode Working modes of boiler: Auto automatic work mode antifreez. antifreeze work mode AlwaysP5 program no. 5 work mode Always- daily temperature mode (lower) Always+ - daily temperature mode + (higher) Always* - daily temperature mode Always ( - night temperature mode Push-buttons specification: save changes return to the previous page go to the next work mode return to the previous work mode Automatic work mode (24 hours, weekly programs) A controller is enable to load into its memory up to 4 values of estimated room temperature. (see fig.20). + - daily temperature + (higher) * daily temperature - daily temperature (lower) ( night temperature You can set the above temperatures to any value. Important! The daily temperature + must be set at the highest value and the night temperature at the lowest. See the next page for 24 h temperature setting details. (fig.21). 20 Fig.20 24 h temperature settings To change temperature value press or. 16

Push-buttons specification: save changes, go to the next program return to the previous page increase temparature value decrease temperature value Important! Make sure you save your changes by pressing button. To build an appropriate 24 h program you have to assign daily temperatures for relevant hours. There are eight (8) 24 h programs loaded into controller memory. You can edit 2 programs only. To enter into 24 h program mode press. 21 Fig.21 24h program + - daily temperature + (higher) * - daily temperature - daily temperature (lower) ( - night temperature To change program press or 0-4 Programs modification is not available 5 Program fixed CH medium temperature (irrespective of outdoor temperature) 6-7 Programs user editable programs Each program has its own mark e.g +. Mark position relates to a given 30min within 24hours. If you point at any mark, a corresponding hour will be displayed in the right upper corner of the display. To edit/view 24 h program press or If you point at any mark you will see the related hour (at the right upper corner). To change the mark press or. Important! Make sure you save your changes by pressing button. If the courser is pointed at program no - return to the main view - save changes - go to the 24h program ( time:23.30) - go to the 24h program ( time:00.00) - go to another 24h program - go to another 24h program If the courser is pointed at hour - to point at program no - save changes - go to the previous hour edition - go to the next hour edition - to change temperature related to a given hour - to change temperature related to a given hour PL-015B/f. 17

Program no 5 is editable only to set the CH medium temperature (you can set a temperature the same way as for other daily programs) Week program enables to assign one of the eight programs for relevant day of the week. See fig.22. 22 Fig.22 Week program There are numbers 1,2,3,4,5,6,7. The numbers relate to day of the week (e.g. no 1- Monday) Prog. shows the related daily program number. The cursor shows current 24 h program number. To change program press or (if you proceed to the next program you will save automatically your previous settings). save program no., go to the next program go to the previous page to change daily program no to change daily program no Pump working mode To set the pump working mode go to page Pump mode 23 Fig.23 Pump working mode There are two working modes of pump: - automatic work mode - continuous working mode save changes go to the previous page to change pump work mode to change pump work mode If you select Auto work mode, the pump will stop operation in the case of: a room temperature reaches the desired value, b) NA contacts are opened ( master appliance is on ), c) outdoor temperature reaches or exceeds maximum outdoor temperature (Tz Maximum value). Important! Pump stops working after 90 sec. Irrespective of working mode, the pump is activated once every 24hr for 1 min. (it protects a unit and CH system against silting up). The pump activation time: 12.00. In boiler (fig.6, page8) both the CH pump and the second circuit pump Pump2 will run simultaneously. The second pump is connected to ZIO22 board (to the POMPA2 connectors). 18

Current time setting To set the current time go to page Time (fig.24) 24 Fig.24 Time To change hour/minute/day press or. Press to save your changes. Important: If the clock battery runs flat, change the CR 2032 battery located inside of the controller. save changes go to the previous page to increase the value to decrease the value Room temperature sensor. A room temperature sensor is optional accessory. The room temperature is measured to turn off heating operation in the case of room over heating (when the room is overheated for a reason other than operation of CH system e.g. exposition to the direct sunshine). Controller turns off heating operation when the room temperature exceeds the hysteresis value. The value of hysteresis is expressed in Celsius degrees. For the hysteresis settings details refer to fig.25. 25 Fig.25 Hysteresis Hysteresis temperature range is 0,5-3,0 C. A controller turns on heating operation shortly after the temperature drops below the temperature that has been set at 24hours temperature program. A value of desired room temperature is displayed on the Main View (see page 11). The desired temperature value includes value of hysteresis. Example: If the daily temperature is set at 20 C and the hysteresis value is set at 1 C then the desired room temperature is 1 C degree higher. When controller turns off heating operation due to exceeded temperature limit (daily temp. +hysteresis) the desired temperature is 20 C (daily temperature hysteresis). save changes go to the previous page to increase the value to decrease the value PL-015B/f. 19

DHW Pump To set the DHW pump program (on/off time) go to page DHW Pump. On/off pump program can be set for every one hour (24hours). 26 Fig.26 DHW Pump To change the value (0-1) press or. 1 pump on 0 pump off To go to the next hour without changing the previous one press. go to the next hour go to the previous page to set to 1 (pump on ) to set to 0 (pump off ) DHW Cylinder DHW Cylinder temperature reading Controller enables measuring a water temperature in the cylinder. To measure the water temperaure the cylinder has to be equipped with either a thermostat or the WE-008 KOSPEL temperature sensor. To set the measurement method (thermostat or WE-008 sensor) go to Extended Menu page For thermostat/sensor wiring details see fig.6 on page 8. DHW Cylinder programming To set up a program of DHW Cylinder go to page a or b. a) Heat exchanger (1) 24hr program b) Heat exchanger (2) current temperature reading and setting You can set the page a) the same way you set the page of DHW pump (refer to DHW pump section) 27 Fig.27 DHW Cylinder 24 hr program 1 cylinder on 0 cylinder off In order to ensure an energy efficient operation you can set the DHW Cylinder working time according to hours of the low-tariff rate. 20

go to the next hour go to the previous page to set to 1 (cylinder on ) to set to 0 (cylinder off ) 28 Fig.28 DHW Cylinder with temp. sensor Fig. 28 and 29 shows the page b) depends on temperature measurement method. If the sensor is applied the page shows both the current DHW temperature and the desired temperature. To change desired temperature press or. To save your changes press. The desired temperature value includes value of hysteresis. The hysteresis value is pre-set in factory to 10 degree. To change hysteresis value go to Extended Menu page. Failures specification: sensor disconnection failure zw - sensor short circuit failure Desired temperature range: 40 do 80 C. Important! Make sure you save your changes by pressing button. save changes go to the previous page to increase the value to decrease the value If the thermostat is applied the page b) displays information as shown in fig 29. 29 Fig.29 DHW Cylinder with thermostat Thermostat opened - informs that the thermostat contacts are opened. Thermostat closed - informs that the thermostat contacts are closed (DHW heating on ) To change the desired temperature value use thermostat knob control. PL-015B/f. 21

Second heating circuit settings Boiler is designed to supply and control two heating circuits (e.g. radiators and under-floor circuit). To control the second circuit (e.g. under-floor) the three-way valve has to be connected to ZIO board. The desired temperature of the second circuit is set on 24h temperature page. The N parameter is set on Circuit #2 page. (fig.30).to set the heating circuits go to page Extended Menu. 30 Fig.30 Second circuit To change N parameter value of second circuit press or. To save your changes press. save changes go to the previous page to increase the value to decrease the value Important: To control the second circuit the circuit must be equipped with the following devices: mixing valve, WE-008 Kospel S.A. temperature sensor and the second circuit pump (fig.6). Devices connection details: Mixing valve - ZTM entry Sensor - Tco2 entry Pump - Pump 2 entry The sensor measures temperature of CH medium on the second circuit inlet (after the mixing valve). For the mixing valve connection details see fig.4 on page 7. ZTM contacts of ZIO board enables controlling the mixing valve. The mixing valve has to be fixed as shown in fig.6 Central heating parameters view To switch over from the Main View to Heating data press a. 31a 31b Fig.31a Heating data (EKCO.M1z) Fig.31b Heating data (EKCO.TM) Heating data display view shows (in sequence): boiler inlet temp, boiler outlet temp, desired temp - in brackets, current power (kw), flow rate (litres/minute) EKCO.TM model measures the outlet temperatures from both heating boxes. not applicable not applicable not applicable 22

Faults To switch over from the Main View to Faults press or. 32 Fig.32 Faults Faults display view shows possible failures: flow failure, outdoor/room temperature sensor failure, inlet /outlet boiler sensor failure. To switch over to the next failure press The controller enables you to recognise the sensor failure: short circuit or sensor disconnection/ missing. Moreover, the controller shows a flow value in the case of very low rate of flow. Sensors specification: Tz outdoor sensor Tp room Tco-we inlet boiler sensor Tco-wy outlet boiler sensor not applicable go to the previous page next fault not applicable Extended Menu Extended Menu settings can be changed by qualified person only. To edit Extended Menu go to Extended Menu code page (fig.33)and enter the 3 digit code. To enter the code press or and. Standard factory preset code is 000 or 001. 33 Fig.33 Extended Menu code save the digit go to the previous page to change the digit to change the digit PL-015B/f. 23

The code let you go to Extended Menu page as shown in fig.34 34 Fig.34 Extended Menu To change parameters press or. To save your changes press. save changes not applicable not applicable to increase the value to decrease the value Important: The boiler doesn t operate while the parameters are being changed. Heating parameters fig. 3a or fig.4 - for radiator central heating system fig.3b for under-floor heating system Tco0 CH medium temperature in the case of outdoor temperature sensor failure 70 50 IKEYt time (sec.) the Main View page automatically returns if you don t use any buttons This parameter is not applicable for Extended Menu page 30 30 Tcomax maximum CH medium temperature in the central heating system 85 60 3F_e zew_t pok_t ZG_MOC 1 indicates the symmetry failure, 0 indicates that there is no symmetry failure. Parameter value is 0 for single-phase boilers. outdoor temperature reading intervals (min.). 0 indicates the reading for every sec. 1 indicates the reading for every minute room temperature reading intervals (min.). 0 indicates the reading for every sec. 1 indicates the reading for every minute power of the heating box 10 10 5 5 NS number of heating elements 6 6 WChG Grz. Nag. Pod. radiator coefficient main circuit (radiator) main circuit (heater) main circuit (under-floor heating) Tcomin minimum CH medium temperature in the central heating system. 29 29 PZMR desired room temperature for antifreeze program 7 7 Nr number of slave boiler in cascade connection 0 0 code1, code2, code3 three digit code to enter Extended Menu. Tcwu outlet boiler temperature (DHW heating) 85 85 Tzas styk DS. parameter of the following value: if you use cylinder thermostat if you apply Kospel temperature sensor Tzas_h DHW Cylinder hysteresis (Celcious degree) 10 10 Tc2max maximum heating temperature of the second circuit 60 - Grz. Pod. 24

Tc2_0 second circuit temperature in the case of outdoor sensor failure 50 - Tc2_d Higher parameter value will affect more delay for the three-way valve opening and closing operation. In the case of the three-way valve outlet oscillation (valve opens or closes too quick) and 5 5 outlet temperature oscillation then increase the parameter value. Important! If you rise this parameter too far it may slow down the control time too much. RP parameter of the following value: Pzmr if you close the WR contacts on extended module the controller switches for antifreeze program. Noc if you close the WR contacts on extended module the controller switches for night temperature program. WChG2 this parameter relates to second heating circuit see WChG. Pod. - GSM value of 0 GSM not applied, value of 1 GSM is applied. CYRL P P2 2Tco value of 0 display without cyrillic letters, value of 1 cyrillic letters display to move the heating curve for the main heating circuit to move the heating curve for the second heating circuit independent view of outlet temperature from the left and right heating box. 0 view off 1- view on The last page asks, if you want to return to factory settings. If you enter TAK, all settings (except for the heating box power) will return to the standard value. Some of the factory settings e.g. 3F_e, after completing this function, may be not suitable for this particular version of the boiler or installation system. Please maintain cautious while using this function. When you save your changes, the controller will reset automatically. Boiler co-operation in cascade connection CH Parameters page shows the working parameters of slave boilers in cascade connection. See fig. 35 35 Fig.35 Boiler in cascade connection The cursor points the ID number of boiler which parameters are being displayed. Boiler no. 0 master boiler. To change ID number of boiler press or CH parameters page shows (in sequence): inlet temp., outlet temp., desire temp., time (sec.) that went by from your last successful communication with the boiler. The last row shows: current boiler power, current rate of flow (litres/min.). ---- mark informs that the boiler is off F mark informs that master boiler switched off the slave boiler due to its insufficient rate of flow (but different than 0). The boiler switches on every hour to verify its rate of flow. The slave boilers can individually co-operate with DHW Cylinder even though they work in cascade. PL-015B/f. 25

GSM remote control 36 Fig.36 GSM module EKCO.M1z model equipped with PSK.M2 controller and GSM module or EKCO.TM model equipped with PSK.M3 controller and GSM module allows you to control boiler operation via mobile phone. automatic antifreeze The GSM module can also send information about the current boiler status to your mobile phone. Set the GSM parameter value at 1 (in Extended Menu ) to display a view as shown in fig.36. An exclamation mark after GSM indicates connection failure. Message e.g. + CSQ: 29,0, indicated successful connection. The numerical value shows the signal strength. The value below 15 indicates a very weak signal. Insert the active SIM card into the GSM module (PIN code function must be off ). Send the appropriate short text message (capital letter) to switch boiler operation to the desired work mode. SMS specification list: A automatic mode P antifreeze mode D fixed daily temperature N - fixed night temperature Z DHW.YES DHW.NO or DHW.NO DHW.YES see boiler and DHW Cylinder configuration K - CH.YES CH.NO or CH.NO CH.YES, see boiler and DHW Cylinder configuration H - If you send H (or any other letter that is not recognised by the system) you will receive the support message 0 boiler off 1 to change configuration CH-YES, DHW-YES When you send another SMS than listed above the boiler skip it over. After you received the SMS the display will show AUTHORIZED and the message that has been sent. The support message shows the SMS specification list. After you switch to the desired working mode you will receive SMS about the current boiler status. e.g.: 15:42 Boiler on. DHW Cylinder on. Auto mode. Tz=1 Tp=24 Tc=55 The exemplary SMS above informs that the boiler is on and co-operates with DHW Cylinder (see Boiler and DHW Cylinder configuration on page 13). The parameters above informs that: Outdoor temp. = 1 0 C Room temp. = 24 0 C CH medium temp. = 55 0 C The SMS may also inform you about fault e.g. flow failure or missing sensor if occurs. You can also receive SMS about the current boiler status by dialling the SIM card phone number. The boiler will interrupt your phone call and send you the SMS immediately. Only the authorised phones can be used to control the boiler operation. To authorise the phones number go to GSM page, fig.36. You can authorise two phone numbers only ( Nr1 and Nr2 ). To switch to the next phone number press or. To go to the next number press To switch the number press or. To save the complete phone number press (after you set the last digit). fixed daily temperature fixed night temperature wyłączenie kotła save digit and go to the next one or save the whole phone number after you set the last digit go to the previous page to increase the number value or to switch to NR2 to decrease the number value or to switch to NR1 26

List of figures. Fig.1a, 1b, 1c Fixing the boiler to the wall. 5 Fig.2 Exemplary scheme of central heating system 6 Fig.3 Exemplary scheme of central heating system radiators, under-floor heating, DHW cylinder, DHW circuit. 6 Fig.4 Connection to the electric mains 7 Fig.5a Connection of the EKCO.M1z to the three phase system. 7 Fig.5b Connection of the EKCO.M1z to the single phase system (for boilers of 4kW,6kW and 8kW) 7 Fig.6 Connecting external appliances to the ZIO board. 8 Fig.7a Boiler in cascade connection 9 Fig.7b Additional electrical connection for boilers in cascade 10 Fig.8 Control panel 11 Fig.9a Controller reset (EKCO.M1z) 11 Fig.9b Controller reset (EKCO.TM) 11 Fig.10 Main view in configuration - CH mode on & DHW mode on or CH mode on & DHW mode off 11 Fig.11 Main view in configuration central heating mode off and DHW mode on 12 Fig.12 Main view in configuration central heating mode off and DHW mode off 12 Fig.13 Language page 13 Fig.14 Configuration view 13 Fig.15 Heating curve. 14 Fig.16 Heating curve edit page. 14 Fig.17 Heating curve 15 Fig.18 Outdoor temperature limit 15 Fig19. Working mode 16 Fig.20 24 h temperature settings 16 Fig.21 24h program 17 Fig.22 Week program 18 Fig.23 Pump working mode 18 Fig.24 Time 19 Fig.25 Hysteresis 19 Fig.26 DHW Pump 20 Fig.27 DHW Cylinder 24 hr program 20 Fig.28 DHW Cylinder with temp. sensor 21 Fig.29 DHW Cylinder with thermostat 21 Fig.30 Second circuit 22 Fig.31a Heating data (EKCO.M1z) 22 Fig.31b Heating data (EKCO.TM) 22 Fig.32 Faults 23 Fig.33 Extended Menu code 23 Fig.34 Extended Menu 24 Fig.35 Boiler in cascade connection 25 Fig.36 GSM module 26 This product must not be treated as a communal waste. Dismantled appliance ought to be given to an appropriate recycling point for electrical and electronic waste. Appropriate disposal of the used product prevents potential negative influence on the environment, which could occur in case of an improper waste disposal. In order to obtain more detailed information on the recycling of the product, contact your local authority, refuse disposal services or the store, where the product has been purchased.

KOSPEL S.A. ul. Olchowa 1 75-136 Koszalin tel. +48 94 346 38 08 info@kospel.pl www.kospel.pl