Internal Conversion. Laboratory Exercise in Nuclear Physics. Spring 2012

Similar documents
Introduction to Geiger Counters

GAMMA-RAY SPECTRA REFERENCES

Atomic and Nuclear Physics Laboratory (Physics 4780)

Gamma Rays OBJECT: READINGS: APPARATUS: BACKGROUND:

Nuclear Physics. Nuclear Physics comprises the study of:

Tutorial 4.6 Gamma Spectrum Analysis

Radiation Detection and Measurement

Basics of Nuclear Physics and Fission

Main properties of atoms and nucleus

Chapter 18: The Structure of the Atom

ENERGY LOSS OF ALPHA PARTICLES IN GASES

The accurate calibration of all detectors is crucial for the subsequent data

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

BETA DECAY. transition probability/time

Objectives 404 CHAPTER 9 RADIATION

2, 8, 20, 28, 50, 82, 126.

Radioactivity III: Measurement of Half Life.

Nuclear Magnetic Resonance

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

ABSORPTION OF BETA AND GAMMA RADIATION

Chemistry 1000 Lecture 2: Nuclear reactions and radiation. Marc R. Roussel

13C NMR Spectroscopy

ELECTRON SPIN RESONANCE Last Revised: July 2007

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

NMR - Basic principles

ORTEC AN34 Experiment 7 High-Resolution Gamma-Ray Spectroscopy

Vacuum Evaporation Recap

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

Advanced Physics Laboratory. XRF X-Ray Fluorescence: Energy-Dispersive analysis (EDXRF)

Chapter NP-5. Nuclear Physics. Nuclear Reactions TABLE OF CONTENTS INTRODUCTION OBJECTIVES 1.0 NUCLEAR REACTIONS 2.0 NEUTRON INTERACTIONS

History of the Atom & Atomic Theory

INFRARED SPECTROSCOPY (IR)

Atomic Structure: Chapter Problems

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

Measurement of Germanium Detector Efficiency

Arrangement of Electrons in Atoms

Unit 1 Practice Test. Matching

Basic Nuclear Concepts

Name Date Class ELECTRONS IN ATOMS. Standard Curriculum Core content Extension topics

Radiation Strip Thickness Measurement Systems

Nuclear Physics and Radioactivity

[2] At the time of purchase of a Strontium-90 source, the activity is Bq.

Determination of Molecular Structure by MOLECULAR SPECTROSCOPY

Gamma and X-Ray Detection

MASS DEFECT AND BINDING ENERGY

X-ray Spectroscopy. 1. Introduction. 2. X-Ray Spectra of the Elements. Physics Advanced Physics Laboratory

Masses in Atomic Units

Physics 1104 Midterm 2 Review: Solutions

Atomic Structure Ron Robertson

Atomic Calculations. 2.1 Composition of the Atom. number of protons + number of neutrons = mass number

CHEM 1411 Chapter 5 Homework Answers

X Ray Flourescence (XRF)

Theory of electrons and positrons

EDS system. CRF Oxford Instruments INCA CRF EDAX Genesis EVEX- NanoAnalysis Table top system

WAVES AND ELECTROMAGNETIC RADIATION

Calorimetry in particle physics experiments

Introduction to Nuclear Physics

Lectures about XRF (X-Ray Fluorescence)

3 Atomic Structure 15

Proton Nuclear Magnetic Resonance Spectroscopy

Environmental Health and Safety Radiation Safety. Module 1. Radiation Safety Fundamentals

Physical Principle of Formation and Essence of Radio Waves

Introduction to the Monte Carlo method

Electrons in Atoms & Periodic Table Chapter 13 & 14 Assignment & Problem Set

Lecture 2 Macroscopic Interactions Neutron Interactions and Applications Spring 2010

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

University of California at Santa Cruz Electrical Engineering Department EE-145L: Properties of Materials Laboratory

Solid State Detectors = Semi-Conductor based Detectors

Atoms Absorb & Emit Light

NUCLEAR MAGNETIC RESONANCE. Advanced Laboratory, Physics 407, University of Wisconsin Madison, Wisconsin 53706

Chapter 13 Spectroscopy NMR, IR, MS, UV-Vis

Origins of the Cosmos Summer Pre-course assessment

AP* Atomic Structure & Periodicity Free Response Questions KEY page 1

PHYA5/1. General Certificate of Education Advanced Level Examination June Unit 5 Nuclear and Thermal Physics Section A

ACCELERATORS AND MEDICAL PHYSICS 2

PHY4604 Introduction to Quantum Mechanics Fall 2004 Practice Test 3 November 22, 2004

Chemistry 2 Chapter 13: Electrons in Atoms Please do not write on the test Use an answer sheet! 1 point/problem 45 points total

Chapter 7. Electron Structure of the Atom. Chapter 7 Topics

Name Partners Date. Energy Diagrams I

4. It is possible to excite, or flip the nuclear magnetic vector from the α-state to the β-state by bridging the energy gap between the two. This is a

NOTES ON The Structure of the Atom

Gamma-Ray Spectroscopy Dan Amidei and Ramón Torres-Isea

TIME OF COMPLETION NAME SOLUTION DEPARTMENT OF NATURAL SCIENCES. PHYS 3650, Exam 2 Section 1 Version 1 October 31, 2005 Total Weight: 100 points

Wave Function, ψ. Chapter 28 Atomic Physics. The Heisenberg Uncertainty Principle. Line Spectrum

ENERGY PER PHOTOELECTRON IN A COINCIDENCE LIQUID SCINTILLATION COUNTER AS A FUNCTION OF ELECTRON ENERGY. Donald L. Horrocks

A-level PHYSICS (7408/1)

Amptek Application Note XRF-1: XRF Spectra and Spectra Analysis Software By R.Redus, Chief Scientist, Amptek Inc, 2008.

Used to determine relative location of atoms within a molecule Most helpful spectroscopic technique in organic chemistry Related to MRI in medicine

Question: Do all electrons in the same level have the same energy?

Current Staff Course Unit/ Length. Basic Outline/ Structure. Unit Objectives/ Big Ideas. Properties of Waves A simple wave has a PH: Sound and Light

The rate of change of velocity with respect to time. The average rate of change of distance/displacement with respect to time.

(3) Interaction of high energy photons with matter

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Pearson Physics Level 30 Unit VIII Atomic Physics: Chapter 17 Solutions

GRID AND PRISM SPECTROMETERS

The Mainz LXe TPC MC simulations for a Compton scattering experiment

Preview of Period 3: Electromagnetic Waves Radiant Energy II

List the 3 main types of subatomic particles and indicate the mass and electrical charge of each.

Crystalline solids. A solid crystal consists of different atoms arranged in a periodic structure.

Transcription:

Internal Conversion Laboratory Exercise in Nuclear Physics Spring 2012 This laboratory exercise deals with a method of measuring the multi-polarity of a γ transition in an atomic nucleus. By measuring (indirectly) the relative intensity of conversion electrons to γ radiation, the multi-polarity will be deduced. Before the lab. exercise you should read the following parts in the Krane textbook (K.S. Krane, Introductory Nuclear Physics) or corresponding sections in the other recommended course literature. β Decay. Angular Momentum and Parity Selection Rules (Krane, chapter 9.1-9.4) γ Decay. Angular Momentum and Parity Selection Rules (Krane, chapter 10.1-10.4) Internal Conversion (Krane, chapter 10.6) Auger Effect (Any textbook in Atomic Physics, for example: Ch. 18.7 in Haken & Wolf, The Physics of Atoms and Quanta.) Scintillation Detectors (Krane, chapter 7.3) 1 Detection of Radiation This section summarizes some basics about the interaction of ionizing radiation associated with nuclear decays with matter. To understand the techniques used to detect the particles emitted from a nucleus or an atom it is necessary to understand these processes. 1.1 Protons and α Particles When a charged particle enters a material it will slow down and also change direction due to primarily electromagnetic interactions with the atomic electrons in the material. The electric field of the particle will excite electrons to higher states or will free bound electrons from the atoms in the material. If an electron acquires enough energy to travel through the material it can excite other electrons, so-called secondary electrons. The possible ways of excitation depend 1

on the material. In a gaseous detector electron-ion pairs are generated, move towards the electrodes, and are collected due to a strong electric field. The resulting signal can be made proportional to the energy deposited by the ionizing radiation. In a semiconductor the idea is to excite electrons from the valence band into the conduction band creating electron-hole pairs. An applied voltage can also in this case extract the created charge. In scintillating materials the excited atomic electrons will de-excite, sending out photons. The resulting light can be collected and amplified with a photomultiplier, creating an electronic pulse for which the amplitude is proportional to the deposited energy. The general expression for the change in energy per distance, de/dx, for a charged particle slowing down in a material is called Bethe-Blochs formula and is given by: de ( ) e 2 2 4πz 2 [ dx = N a Z ρ 4πɛ 0 m e c 2 β 2 ln A where: e is the electron charge ɛ 0 is the permeability in vacuum ( 2me c 2 β 2 z is the incoming particle s charge in e ρ is the density of the material m e is the electron mass C is the shell correction parameter c is the speed of light β is v/c for the incoming particle A is the molar mass of the material I is the mean excitation potential δ is a density correction term I ) ln(1 β 2 ) β 2 δ C ], Z (1) Note that de/dx is proportionated to z 2. This means for example that an alpha particle will stop much faster compared to a proton in a given material. 1.2 Electrons There are resons why the electron (and the positron) must be treated differently from the other charged particles. One reason is the small mass. One of the assumptions of the Bethe-Blochs formula is that the mass of the incoming particle is much larger than the mass of the electrons in the material. We therefore assume the particle to move in the same direction after interacting with 2

an electron. This can be a good approximation for incoming protons or α particles, but not for electrons. Another difference is that two colliding electrons are not separable. A quantum mechanical treatment of the problem therefore introduces new terms for the electrons. Apart from the inelastic scattering against other electrons, another mechanism will also be important, namely emission of Bremsstrahlung. This emission of electromagnetic radiation is due to the deceleration of the electrons when they enter the material. The cross section for Bremsstrahlung is dependent on the mass as: σ b = ( e2 mc 2 )2. (2) We se that Bremsstrahlung is more important for high energies, and that it must be much more important for electrons than for heavier particles like protons or α-particles. For electrons at an energy of about 10 MeV, the Bremsstrahlung effect is about as large as the effect from inelastic scattering. 1.3 Gamma Radiation A γ-photon can interact with a material in three ways: Photo absorption Compton scattering Pair production 1.3.1 Photo Absorption The γ-photon can be absorbed completely by giving all its energy to an atomic electron in the material. This electron will have the same energy as the photon (except for the small binding energy). The electron will then excite many other so-called secondary electrons. The total energy of these electrons corresponds to the photon energy, so if we can measure this total energy we get the photon energy. 1.3.2 Compton Scattering If the photon only gives part of its energy to an electron in the material, the photon will continue to travel through the material, but in a new direction and with a lower energy. It can then be photo-absorbed, it can Compton scatter again, or it can escape from the material (for example from a detector). The electron that was hit will excite other electrons in the material. If the scattered photon ecapes from the detector, the total electron energy will be lower than the energy of the incoming photon. In this case, the measured energy does not correspond to the γ-ray energy. 3

1.3.3 Pair Production If the γ-photon has enough energy, it can interact with the electromagnetic field of a nucleus and create an electron-positron pair. The positron will soon find an electron in the material and this electron will annihilate with the positron after a short time, creating (in most cases) two 511 kev γ-photons emitted in approximately opposite directions. 2 Multipolarity A discrete state in an atomic nucleus is characterised by (among other things) its parity, and its spin. If we can determine the spin and parity experimentally, we can learn something about the inner structure of the nucleus (using a given model). It is therefore important to find ways of deducing the spin and parity for the different states of the nucleus. To find information about the different states of a nucleus we study the transitions between the states. A transition from one state to a energetically lower state will result in the emission of energy from the nucleus. This energy is usually emitted in the form of a γ photon, but the nucleus can also interact with the electrons of its atom to release the excess energy. The latter process is called Internal Conversion. A γ photon emitted from a nucleus will have an energy corresponding to the difference in energy between the initial and final state of the nucleus. The multipolarity of the photon corresponds to the angular momentum that the photon carries away from the nucleus. If we know the spin and parity of one of the states, we can learn something about the spin and parity of the other state by measuring the multipolarity of the emitted photon. The multipolarity of a nuclear transition can be measured in various ways. One striking difference between different multipolarities is the angular intensity distribution of the radiation. The distribution is given by the Legendre polynomials (as a function of cosθ where θ is the angle of emission with respect to the quatization axis) of the corresponding order. The distribution of the radiation for one transition will only give us information about the order of the transition, it is not possible to see if the transition is magnetic or electric. To do this we also need to measure the polarisation of the radiation. To get an non-isotropic intensity distribution, the magnetic sub-levels must be unevenly populated. Assuming, see figure 1 that an I=1 state is de-excited into an I=0 state, we have three possible transitions corresponding to the three magnetic sublevels for I=1. Each transition has a different m, and therefore a different angular intensity distribution. The problem is that it is not trivial to separate the three transitions. We can split the levels by applying an external magnetic field (Nuclear Zeeman effect), but even a very large field will not make it possible to separate the transitions with a normal γ-ray detector. We will therefore see a sum of the three angular distributions, and if the sub-levels are evenly populated the sum will be isotropic. One way to solve the problem is 4

I=1 B = 0 m I -1 0 +1 m=0 m=+1,-1 I=0 Total Figure 1: The degenerate energy levels can be separated by a magnetic field. Each component in the decay will then have a specific angular distribution. But if the sub-levels are evenly populated the sum distribution will be isotropic. to lower the temperature of the source so that the Boltzmann distribution will give an uneven population of the sub-levels. To do this, the temperature must typically be as low as about 0.01 K. We see that there are several difficulties in using the intensity distribution for measuring the multipolarity of a nuclear transition. There are however other ways of solving these difficulties, like using so-called angular correlation measurements (Krane, ch. 10.4). In this laboration we will use another technique to measure the multipolarity of a transition. This method does not depend on the angular intensity distribution of the γ radiation. Instead, we use the fact that the the relative intensity of internal conversion depend on the multipolarity of the transition (the intensity does also depend on other factors, see Krane, page 346). By measuring the internal conversion intensity, we can therefore deduce the multipolarity of the transition. 3 Internal Conversion The internal conversion coefficient is defined as: α ic = I e I γ, (3) where I e is the intensity of the conversion electrons and I γ is the intensity of the gamma radiation. I γ can easily be determined by calculating the area of the corresponding peak in the energy spectrum obtained with the γ-ray detector (NaI scintillation detector). To determine the intensity of the conversion electrons we will first not measure the electrons directly (for this we need an 5

(4) e - L K Hole (2) e - (1) e - γ (3) X-ray Figure 2: A schematic picture of different ways to de-excite an atomic nucleus. The nucleus can be de-excited by γ-ray emission (1), but also by emitting a closely bound electron from the atom (2). Usually a K-electron is emitted, but an electron in the L-shell (or a higher shell) can also be emitted. The electron hole that appears will soon be filled by another electron. This can result in the emission of an X-ray photon (3), or the emission of an Auger electron (4). 6

electron detector, see below). We will measure the electron intensity indirectly by deducing it from the X-ray radiation that is sent out when the electron vacancies (created by sending out the conversion electrons) are filled by electrons from higher lying shells. This intensity must however be corrected to account for the Auger effect, since this process competes with X-ray emission. The ratio, η, between the X-ray intensity I X and the intensity of internal conversion I ic is called fluorescent yield and it is given as: η = I X I ic. (4) Diagrams for η can be found in Appendix A. Another problem is that we must compensate for the efficiency of the detector. The efficiency of a γ-ray detector is strongly energy dependent. An efficiency curve can be determined by measuring the intensities of some γ-ray peaks for a number of calibration sources. Using the efficiency curve, the ratio between the detector efficiencies for the X-rays and γ-rays of interest can be measured as: ɛ = ɛ γ. (5) ɛ X By combining the relations above we can now calculate α ic. Diagrams that relate α ic to energy and multi-polarity can be found in Appendix B. From the multipolarity we can conclude the spin and parity for the 662 kev state of 137 Ba by using the selection rules for γ-ray transitions. 4 Equipment A schematic picture of the detector set-up of the present lab exercise is seen in figure 3. A radioactive source is placed in front of a germanium detector or a scintillation detector. The source will emit γ-rays from nuclear de-excitation, and also X-rays that originate from internal conversion. If it is sealed any α or β radiation is absorbed in the encapsulation. The electronic signal from the detector is fed into an amplifier and then to a multi-channel analyser (MCA) that can sort the signal into a large number of energy channels. The Tukan PC software is then used to display and analyse the energy spectrum. There is another measurement station which uses a thin plastic scintillation detector which is mainly sensitive to the beta particles and conversion electrons. For this measurement open radioactive sources are used. Let the lab assistant handle the sources! 5 The Laboration In the present laboration we use a sources of 137 Cs to study internal conversion. The 137 Cs nucleus decays by β-decay into two different states in 137 Ba (figure 4). One of these states is the ground state, the other is an excited state, 662 kev above the ground state. 7

Source PC NaI/plastic det Amplifier TUKAN X-ray γ -ray MCA Card Figure 3: The detector set-up of the present laboration. + 7/2 137 Cs β - 94.6% π I =?? 661.6 kev 5.4% γ α ik =? + 3/2 0 kev 137 Ba Figure 4: The decay of 137 Cs into two states of 137 Ba. The purpose of the lab. exercise is to determine the spin and parity of the excited 662 kev state of 137 Ba. 8

5.1 Start the ACQ The MCA PC card is controlled by the Tukan software on the PC. Let the lab assistant put a source a 137 Cs source in front of the NaI detector and start the acquisition system from within Tukan. Try to explain what you see in the different parts of the spectrum. 5.2 Energy Calibration The multichannel analyser (MCA) is not energy calibrated before the lab. exercise. Use the known energies of barium K X-rays (32 kev) and γ rays from the 137 Cs source to perform the energy calibration. 5.3 Efficiency Curve To determine the conversion coefficient α ic we must first measure the efficiency of the detector as a function of energy. This is done by using the known intensity for a number of γ-transitions in a few calibration sources. The half-lifes and reltive gamma intensities are found in table 1. 5.4 Determine α ic Now we can determine the conversion coefficient α ic by using the relations above, using the graphs given in Appendix B. Intensities can obtained from the MCA software online. For a somewhat more careful analysis, export the spectrum to ascii format and fit the peaks using Gaussian shapes with a proper background subtraction using your favourite software. Include the result of your more careful analysis in the lab report. 5.5 Error estimation In order to have a meaningful and correct interpretation of the extracted result an error estimation is required. 5.6 Spin and Parity The multipolarity for the 662 kev transition can now be determined from a the calculated values for different multipolarities and energies. When we know the multipolarity we can deduce the spin and parity for the 662 kev level in 137 Ba by using the selection rules. 5.7 Direct measurement of α ic Measure the β spectrum using the plastic scintillation detector (marked β) and identify the different components. Store the spectrum and export it to ascii form for later analysis. Determine α ic from this measurement. Here you may assume that the detector efficiency is independent on the electron energy. Note 9

Source Half-life E γ (kev) I γ (%) 57 Co 271.7 d 14.4 9.2 122.1 85.6 136.5 10.7 241 Am 432 y 26.3 2.4 59.5 36.0 133 Ba 10.52 y 81.0 34.1 276.4 7.1 302.9 18.3 356.0 61.9 383.8 8.9 22 Na 2.6019 y 1274.5 99.9 60 Co 5.2714 y 1173.2 99.9 1332.5 100.0 152 Eu 13.542 y 121.8 28.4 244.7 7.5 344.3 26.6 411.1 2.2 444.0 3.1 778.9 13.0 867.4 4.2 964.1 14.6 1085.8 10.1 1089.7 1.7 1112.1 13.5 1212.9 1.4 1299.1 1.6 1408.0 20.8 Table 1: sources. Half-lifes, energies, and intensities for a few common calibration 10

that the principal shape of the β spectrum should follow e.g. Krane eq. 9.25. What are the possible sources of error? Discuss any differences between the two complementary measurements of α ic in your lab report. Do they agree within the estimated experimental uncertainties? 6 Questions Try to answer the following questions before the laboration. These questions will be the basis for a discussion at the beginning of the lab. exercise. What is the meaning of the multipolarity of a electro-magnetic transition? What selection rules are valid for the electro-magnetic transitions? Why can there be no M0-transitions? How can a E0-transition be realised? What is internal conversion? How is the internal conversion coefficient defined? What parameters does it depend on? Which conversion electron energies can be observed? 11

Appendix A 12

Appendix B 10 10 10 10 10 9 10 8 Z= 55 Total 10 9 10 8 Z= 55 Total 10 7 10 7 10 6 10 6 10 5 10 5 10 4 10 4 10 3 10 3 10 2 10 2 10 1 10 1 10 0 10 0 10-1 10-2 10-3 E4 E3 E2 E1 10-1 10-2 M4 M3 M2 M1 10-4 101 102 103 E, kev 10-3 F-23 101 102 103 E, kev 13