EATON DFDAP-M / FDAP-M Remote Alarm Panels

Similar documents
Fire Pump Controllers Remote Alarm Panels

EATON Diesel Plus Diesel Engine Fire Pump Controller

HM-W536 Install Guide

INSTALLATION INSTRUCTIONS

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Operation and Installation Manual

OPL BASIC. Dosing System for Professional Laundry machines. Contents

SFC-200 SERIES LCD FIRE ALARM PANEL

TSn SERIES Surge Protective Device

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Advantium 2 Plus Alarm

Water Leak Detection System

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

INSTALLATION INSTRUCTIONS MC95HAE-1 MASTER CONTROLLER

World Class Manufacturer of Fire Pump Controllers. Diesel

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

MIC-WKT and MIC-WKT-IR

Limited Service Fire Pump Controllers Features

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

Diesel Engine Fire Pump Controllers

WD-AMX Water Detection Controllers

What is a multimeter?

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Solid State Timers Type F

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

FIREDEX Conventional Fire Panels

Applied Electronics. Commercial Dimming System UPDATE NOTICE

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Conventional Fire Detection and Extinguishant Control System Specification

Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert AC4. User Manual

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Centro-Matic Automatic Lubrication Systems System Controls

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

GENERATOR TRANSFER SWITCH

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

OPERATING INSTRUCTIONS

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

TMS TANK MANAGEMENT SYSTEM

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

LIEBERT VNSA Installation Sheet

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

MANUAL FOR MODEL MP30 ELECTRIC MOTOR DRIVEN LIMITED SERVICE CONTROLLER

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

EKOS Cart. Instructions for Use

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

Liebert Universal Monitor

Digital Keypad Use s Manual

CB200W Water Leak Detection Panel Application Guide

SECTION LOW VOLTAGE LIGHTING CONTROLS

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Secure Keypads for access control

T7079A,B Solid State Remote Temperature Controllers

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

Contractors Guide Central Inverter System Installation

Repeaters and Mimics Data Sheet

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

GST301. (Single Protection Zone) Operation Manual

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

Drayton Digistat +2RF/+3RF

LINE POWERED ADA TELEPHONE USER S MANUAL Use With Part Numbers , , , , , and

Owner's Manual. Automatic Transfer Switch. This manual should remain with the unit.

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

Remote Alarm Monitoring System

ACS-30-EU-EMDR-10-MOD

Fire Alarm System Plans Review Checklist Property location Date of Review

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

EBDSPIR-PRM, EBDSPIR-PRM-IP

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4

Technical Overview Add-on Sensors - Smoke Alarm. Get yours direct at:

Speed Control Relays SX2

AIS750 Series Alarm Annunciator

Generator Transfer Switch Model # HTS15-AUTO

Power Generation. Power Control PCL System Generator Set Control

Transcription:

O & M Manual IM05805008K

O & M Manual IM05805008K TABLE OF CONTENTS 1. INSTALLATION AND MOUNTING OF THE CONTROLLER 1 2. ELECTRICAL CONNECTIONS 1 2.1 ELECTRICAL CHECKOUT INSTRUCTIONS 2 2.2 ELECTRIC ALARM PANELS 2 2.2.1 Pump Running check 2 2.2.2 Common Alarm check 2 2.2.3 Phase Failure check 2 2.3 DIESEL ALARM PANELS 2 2.3.1 Engine Running' & 'Controller in OFF Mode' check 2 2.3.2 Common Alarm' and 'Low Fuel' check 2 2.4 OPERATION 3 2.4.1 Lamp Test Button 3 2.4.2 Normal and Supervisory (Backup) Voltage 3 2.4.3 Audible Alarm 3 2.4.4 Silence Alarm Button 3 2.4.5 Normal Power ON LED 3 2.4.6 Output Contacts 3 2.4.7 Output Relays 3 2.4.8 Alarm Inputs 3 3. FIGURE 1: ELECTRIC DIMENSIONS & SHIPPING WEIGHTS 4 4. FIGURE 2: DIESEL DIMENSIONS & SHIPPING WEIGHTS 5 5. FIGURE 3: ELECTRIC WIRING SCHEMATIC 6 6. FIGURE 4: DIESEL WIRING SCHEMATIC 7 i EATON Corporation www.chfire.com

O & M Manual IM05805008K INSTALLATION & MAINTENANCE MANUAL FOR REMOTE ALARM PANELS In order to familiarize yourself with the Remote Alarm Panel, please read the instruction manual thoroughly and carefully. Retain the manual for future reference.? Incoming Normal power and Supervisory (backup) power connections are clearly marked L and N and are located on the upper right side of the microprocessor board. 1. Installation and Mounting of the Controller Carefully unpack the controller and inspect thoroughly. The controller is not free standing and must be bolted securely to a wall. For dimensional and weight data please refer to the respective data sheets for the. Figure #1 - Electric Remote Alarm Panel Figure #2 - Diesel Remote Alarm Panel 2. Electrical Connections All electrical connections should meet national and local electrical codes and standards. The controller should be located or so protected that they will not be damaged by water escaping from pumps or pump connections. Current carrying parts of controllers shall be a minimum of 12 inches (305 mm) above the floor level.? Prior to starting, verify all data on the nameplate such as, catalog number and AC line voltage.? Inspect all electrical connections, components and wiring for any visible damage and correct as necessary. Ensure that all electrical connections are tightened before energizing.? Install necessary conduit using proper methods and tools. EATON Corporation www.chfire.com 1

O & M Manual IM05805008K 2.1 Electrical Checkout Instructions (For Use with Eaton ) WARNING:The following procedures should be carried out by a qualified electrician familiar with the electrical safety procedures associated with this product and its associated equipment. 2.2 Electric (Full Service) For Electrical Schematic Refer to Figure #3 Note: The alarm buzzer can be silenced by pressing the 'Silence Alarm' button on the front of the controller. 2.2. - Turn power on to the Fire Pump Controller and to the Remote Alarm Panel - In the Fire Pump Controller press the 'Local Start' pushbutton, the controller will start - The 'Pump Running' LED should illuminate and the alarm will sound on the Alarm Panel - Press the 'Stop' pushbutton on the front of the fire pump controller 2.2. - Move the disconnect handle on the Fire Pump Controller to the 'OFF' Position - The 'Common Alarm' and 'Phase Failure' LED's should illuminate and the alarm will sound on the Alarm Panel - Move the disconnect handle back to the 'ON' Position 2.2.3 - In the menu under the Alarm category, change the phase rotation to the opposite of what it is currently set for. - The 'Common Alarm' and 'Phase Reversal' LED's should illuminate and the alarm will sound on the Alarm Panel - Return the menu setting to the correct rotation. 2.3 Diesel For Electrical Schematic Refer to Figure #4 Note: The alarm buzzer can be silenced by pressing the 'Silence Alarm' button on the front of the controller. 2.3.1 - Turn power on to the Fire Pump Controller and to the Remote Alarm Panel - Place the controller in the 'AUTO' mode by turning the Main Switch to AUTO - Start the controller either by jumpering the remote start (Terminal #11 & #34) or by dropping the pressure in the Fire Pump Controller - The 'Engine Running' light should illuminate and the alarm will sound on the alarm panel - Place the controller in the 'OFF' mode by turning the Main Switch to OFF - The 'Not in Auto Mode' LED will illuminate and the alarm will sound on the alarm panel 2.3.2 - Place the controller in the 'AUTO' mode by turning the Main Switch to AUTO - Start the controller either by jumpering the remote start (Terminal #11 & #34) or by dropping the pressure in the Fire Pump Controller - Place a jumper between Terminal #38 & #11 in the Fire Pump Controller (Low Fuel) - The 'Common Alarm and Low Fuel LED s should illuminate and the alarm will sound on the alarm panel - Place the controller in the 'OFF' mode by turning the Main Switch to OFF 2 EATON Corporation www.chfire.com

O & M Manual IM05805008K 2.4 Operation 2.4.1 Lamp Test Button 2.4.7 Each remote alarm panel is equipped with a Lamp Test button that fully tests all LED s when pressed. Operating the lamp test button will not change the state of the internal output relays The alarm panel relays are printed circuit board style mounted on the alarm panel main circuit board. They are rated for 8 amps / 250VAC. They are de-energized under normal conditions regardless of input status selected. 2.4.2 Normal and Supervisory (backup) Supply Voltage 2.4.8 Alarm Inputs The remote alarm panels will accept both 120 volt 50/60Hz and 240 volt 50/60Hz power supply on either of the normal and supervisory (backup) source inputs. If the normal source of supply is lost, the panel will automatically switch to the supervisory (backup) source. Both the normal and supervisory (backup) sources must be independent of each other. Output Relays Each controller is equipped with eight user selectable alarm inputs. Each can be selected as normally open (N.O.) or normally closed (N.C.) by the use of jumpers on the microprocessor board. 2.4.3 Audible Alarm When any alarm conditions are present, the audible alarm will sound. It will continue to sound until either the silence alarm button is pressed, or the alarm condition is satisfied. 2.4.4 Silence Alarm Button An audible alarm silencing button is provided that silences all active alarms when pressed. Pressing the button has no effect on the associated alarm LED(s). Should a second alarm condition occur after the silence button has been pressed, the audible alarm will re-sound until the silence button is pressed again, or the alarm condition has been satisfied. 2.4.5 Normal Power ON LED The normal power ON LED indicates when normal power is available and will turn off when the controller switches to the supervisory (backup) power source. An audible alarm will sound when normal power is not available and will remain ON until normal power is restored, or the silence pushbutton is pressed. 2.4.6 Output Contacts The FDAP-M electric remote alarm panel has four alarm outputs to indicate Phase Failure, Pump Running, Common Alarm and Phase Reversal. The DFDAP-M diesel remote alarm panel also has four alarm outputs that indicate Not in AUTO Mode, Engine Running, Common Alarm and Low Fuel. Two additional Form-C alarm outputs can be programmed to indicate specific alarm conditions. EATON Corporation www.chfire.com 3

O & M Manual IM05805008K Electrical Remote Alarm Panel - FDAP-M 15.49 [393] 11.56 [294] 9.75 [248] 9.55 [243] 8.00 [203] 0.27 [ 7]x4 WALL MTG. HOLES 4.74 [120] NOTE: 1. ALL ENCLOSURES FINISHED IN FIRE PUMP RED 2. CABLE ENTRANCE EITHER TOP OR BOTTOM 3. STANDARD ENCLOSURE TYPE NEMA 1 N. Y. C. APPROVED FIGURE 1 4 EATON Corporation www.chfire.com

O & M Manual IM05805008K Diesel Engine Remote Alarm Panel - DFDAP-M 15.49 [393] 11.56 [294] 9.75 [248] 9.55 [243] 8.00 [203] 0.27 [ 7]x4 WALL MTG. HOLES 4.74 [120] NOTE: 1. ALL ENCLOSURES FINISHED IN FIRE PUMP RED 2. CABLE ENTRANCE EITHER TOP OR BOTTOM 3. STANDARD ENCLOSURE TYPE NEMA 1 N. Y. C. APPROVED FIGURE 2 EATON Corporation www.chfire.com 5

O & M Manual IM05805008K Wiring Schematic - Electric Remote Alarm Panel - FDAP-M : N. Y. C. APPROVED 6 EATON Corporation www.chfire.com FIGURE 3

O & M Manual IM05805008K Wiring Schematic - Diesel Remote Alarm Panel - FDAP-M : N. Y. C. APPROVED FIGURE 4 EATON Corporation www.chfire.com 7

2010 Eaton Corporation All Rights Reserved Printed in Canada Publication No.: IM05805008K March 2010 Eaton Corporation 10725-25th Street NE Unit 124 Calgary, Alberta, Canada T3N 0A4 Tel: +1-403-717-2000 Fax: +1-403-717-0567 email: chcfirepump@eaton.com www.chfire.com