Tips and Tricks for Successful Power Designs. Part 1: EMI/EMC Part 2: Optimizing Efficiency

Similar documents
UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

EMI and t Layout Fundamentals for Switched-Mode Circuits

SELECTING PROPER CONNECTION POINTS FOR Y-CAPACITOR TO REDUCE EMI IN SMPS

Application Note AN:005. FPA Printed Circuit Board Layout Guidelines. Introduction Contents. The Importance of Board Layout

5. MINIMIZATION OF CONDUCTED EMI. Chapter Five. switch-mode power supply decrease approximately linearly with the increase of the switching

Planar versus conventional transformer

Power supplies. EE328 Power Electronics Assoc. Prof. Dr. Mutlu BOZTEPE Ege University, Dept. of E&E

Power Electronic Circuits

AC/DC Power Supply Reference Design. Advanced SMPS Applications using the dspic DSC SMPS Family

Conducted EMI Issues in a Boost PFC Design

Grounding Demystified

Conducted EMI filter design for SMPS

" PCB Layout for Switching Regulators "

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Electromagnetic Compatibility Considerations for Switching Power Supplies

PCB Layout Considerations for Non-Isolated Switching Power Supplies

Power supply output voltages are dropping with each

Design and Applications of HCPL-3020 and HCPL-0302 Gate Drive Optocouplers

AVX EMI SOLUTIONS Ron Demcko, Fellow of AVX Corporation Chris Mello, Principal Engineer, AVX Corporation Brian Ward, Business Manager, AVX Corporation

ILB, ILBB Ferrite Beads

Understanding SMD Power Inductors. Application Note. July 2011

47000 SERIES - ELECTRONIC TRANSFORMERS

Module 11: Conducted Emissions

G019.A (4/99) UNDERSTANDING COMMON MODE NOISE

1ED Compact A new high performance, cost efficient, high voltage gate driver IC family

This application note is written for a reader that is familiar with Ethernet hardware design.

Printed Circuit Boards. Bypassing, Decoupling, Power, Grounding Building Printed Circuit Boards CAD Tools

High Voltage Power Supplies for Analytical Instrumentation

Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications. Application Note. June 2011

11. High-Speed Differential Interfaces in Cyclone II Devices

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions

Input and Output Capacitor Selection

EMI in Electric Vehicles

Application Note: How to Connect a Lantronix Embedded Module to a Wired Ethernet Port

Application Note: PCB Design By: Wei-Lung Ho

TOPOLOGIES FOR SWITCHED MODE POWER SUPPLIES

Precision Analog Designs Demand Good PCB Layouts. John Wu

Application Note, Rev.1.0, September 2008 TLE8366. Application Information. Automotive Power

DC-DC Converter Basics

ISPS2014 Workshop Energy to Smart Grids Presenting results of ENIAC project: E2SG (Energy to Smart Grid)

Application Report. 1 Description of the Problem. Jeff Falin... PMP Portable Power Applications ABSTRACT

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

The leakage inductance of the power transformer

Application Note AN-1135

Designers Series XII. Switching Power Magazine. Copyright 2005

Evaluating AC Current Sensor Options for Power Delivery Systems

SWITCHING REGULATORS

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

Fairchild On-Line Design Tool: Power Supply WebDesigner Step-by-Step Guide

Chapter 2 Application Requirements

AN1031 Considerations in Designing the Printed Circuit Boards of Embedded Switching Power Supplies Marty Brown

CONDUCTED EMISSION MEASUREMENT OF A CELL PHONE PROCESSOR MODULE

EMI Conducted Interference

LVDS Technology Solves Typical EMI Problems Associated with Cell Phone Cameras and Displays

How to design SMPS to Pass Common Mode Lightning Surge Test

Measurement setup for differential-mode and common-mode channels

Line Reactors and AC Drives

AN ISOLATED GATE DRIVE FOR POWER MOSFETs AND IGBTs

1. Challenges of EMI 2. Typical EMI Sources 3. Low, broadband and high frequency EMI problems

White Paper: Electrical Ground Rules

LM 358 Op Amp. If you have small signals and need a more useful reading we could amplify it using the op amp, this is commonly used in sensors.

Current Probes. User Manual

Noise Free 90+ for LCD TV AC Adapter Desk Top. 96% x 96% = 92.16% Champion Microelectronic. 96+ Interleaved CRM PFC CM6565 PFC & PFC PWM PWM

Application Note AN-1070

PCB Radiation Mechanisms: Using Component-Level Measurements to

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

PL-277x Series SuperSpeed USB 3.0 SATA Bridge Controllers PCB Layout Guide

ULRASONIC GENERATOR POWER CIRCUITRY. Will it fit on PC board

7-41 POWER FACTOR CORRECTION

Technical Article. EMC filters for medical devices

Application Note 58 Crystal Considerations with Dallas Real Time Clocks

AND8326/D. PCB Design Guidelines for Dual Power Supply Voltage Translators

Output Ripple and Noise Measurement Methods for Ericsson Power Modules

Chapter 4. LLC Resonant Converter

AND8147/D. An Innovative Approach to Achieving Single Stage PFC and Step-Down Conversion for Distributive Systems APPLICATION NOTE

Design of an Auxiliary Power Distribution Network for an Electric Vehicle

Custom Products. Magnetic Components. Vishay Dale.

Application Note AN- 1095

POWER LINE FILTERS FOR SWITCHING POWER SUPPLIES

EMI can be a difficult

1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING

EMC Standards: Standards of good EMC engineering

When the Power Fails: Designing for a Smart Meter s Last Gasp

EMC-conform development of a Tablet-PC

Application Note: How to Connect a Wired Ethernet Port to the WiPort

PCB Design Conference - East Keynote Address EMC ASPECTS OF FUTURE HIGH SPEED DIGITAL DESIGNS

RX-AM4SF Receiver. Pin-out. Connections

Chapter 6: Converter circuits

Cable Discharge Event

Photolink- Fiber Optic Receiver PLR135/T1

Balun Parameter Definitions & Measurement May 2004

Radiated Emission and Susceptibility

Introduction to Power Supplies

Datasheet. 2A 380KHZ 20V PWM Buck DC/DC Converter. Features

Which is the best PFC stage for a 1kW application?

Automotive EMI System

Design A High Performance Buck or Boost Converter With Si9165

Welcome to this presentation on Switch Mode Drivers, part of OSRAM Opto Semiconductors LED Fundamentals series. In this presentation we will look at:

Switching Regulator Series PCB Layout Techniques of Buck Converter

Transcription:

Tips and Tricks for Successful Power Designs Part 1: EMI/EMC Part 2: Optimizing Efficiency 1

Agenda: Part 1 EMI/EMC EMI/EMC Definition & Standards EMI analysis of various power stages Ways to mitigate using PCB Layout EMI in AC/DC s EMI Analysis 2

Key Learnings EMI and the standards Root cause of EMI created by ALL Switched Mode Power Supplies PCB and Ground Techniques to Mitigate EMI Noise Sources in a Real Schematic Measurement of EMI 3

What is EMI & EMC? EMI (Electromagnetic Interference) unwanted coupling of signals from one circuit to another, or to system Conducted EMI: coupling via conduction through parasitic impedances, power and ground connections Radiated EMI: unwanted coupling of signals via radio transmission EMC (Electromagnetic Compatibility) An electrical systems ability to perform its specified functions in the presence of EMI generated either internally or externally by other systems 4

EMI/EMC Standards EMC Standards vary by: Region US = FCC Europe = CISPR = EN Application usage Consumer Medical Automotive What standards do we use FCC part 15 B CISPR 22 = EN 55022 5

Conducted vs. Radiated Emission Limits Conducted FCC/CISPR Conducted Emission Limits Radiated FCC/CISPR Radiated Emission Limits (measured at 10m) FCC and CISPR standards the same FCC and CISPR standards somewhat different FCC B (consumer) much more stringent than FCC A (commercial, industrial, and business) 6

Compliance Tests for DC s There are no specified EMC limits for DC converters EMC requirements are for complete systems measured on AC lines (and signal lines) DC converter is a subcomponent Pre-compliance testing can be performed to determine if EMI issues might exist Use limit curves from FCC Part 15 B/CISPR 22/EN55022 Use same test set up and LISN as AC mains testing Use same average, quasi-peak, peak measurement methods Eception is Power over Ethernet (PoE) DC input power is on CAT-5 ethernet cable which also is system (signal) cable EMC requirements usually apply to this cable EMC specifications and testing the same as AC lines Special TLISN required to measure 8 wires inside CAT-5 cable (no shield or ground connections) 7

Understanding EMI log scale Define dbμv: V db V V 20Log 10 6 Ex: 500µV = 54dBµV; 2000µV=66dBµV Noise voltage ratio is 4. Only 12dBμV difference In dbμv scale! Be careful! Small difference in dbμv could refer to large difference in μv! 8

How does Noise show up in the System? NOISE SOURCE Emissions!!! ENERGY COUPLING MECHANISM Conducted Electric Fields Magnetic Fields Radiated Low Frequency Low, Mid Frequency, LC Resonance High Frequency SUSCEPTIBLE SYSTEM Immunity 9

Field Apps Engineering Approach to mitigate EMI identify significant EMI Sources EMI Filters NOISE SOURCE Unwanted Emissions Shielding figure out EMI Coupling Paths engineer Circuit Layout to mitigate EMI Conducted ENERGY COUPLING MECHANISM Electric Fields Magnetic Fields Radiated add EMI Filter / Snubber / Shielding EMI Filters SUSCEPTIBLE SYSTEM Shielding 10

SMPS is Big Generator of Radiated and Conducted Emissions Due to High power High di/dt on the switches and diodes Fast transients (voltage and current) Not generally enclosed (not shielded) Parasitic inductance and capacitance in current paths Causing Noise Conducted to Supply and / or Load Interfere with circuits in the same system Interfere with other systems 11

EMI to be considered for a SMPS Conduction emission issue: Solve by EMI filter. Near-field radiation emission issue: Solve by better PCB layout and component placement. Far-field radiation emission issue: Not focused on in this presentation 12

Identify Critical Path Buck Switching Current exist in the input side Boost + - Buck-Boost Critical path 13

Identify Critical Path Buck + Boost - Buck-Boost Critical path 14

Identify Critical Path Non-Inverting Buck + - Boost Inverting Critical path Buck-Boost + - 15

What can we do in PCB Layout? Buck Example +Buck - Boost + - Buck-Boost Minimize critical path area Separate noisy ground path from quiet ground 16

Identify Critical Paths in Isolated s Flyback FLYBACK Forward Vin N P N S D1 C O Vout Push-Pull Half Bridge Full Bridge C in Q1 Critical paths 17

Identify Critical Paths in Isolated s Flyback FORWARD Forward Vin N P N T N S D1 D2 L Vout C O Push-Pull Half Bridge Full Bridge C in Q1 D3 Critical paths 18

Identify Critical Paths in Isolated s Flyback Forward Vin N P1 PUSH-PULL N P2 N S1 D1 L Vout C O Push-Pull C O Q1 Q2 N S2 Half Bridge D2 Full Bridge Critical paths 19

Identify Critical Paths in Isolated s Flyback Forward Push-Pull Vin C2 VIN/2 HALF-BRIDGE Q2 D1 N P N S1 L Vout C O Half Bridge Full Bridge C1 Q1 N S2 D2 Critical paths 20

Identify Critical Paths in Isolated s Flyback Vin FULL-BRIDGE Forward Q3 Q2 D1 L Vout Push-Pull Half Bridge Full Bridge C in Q4 Q1 N P N S1 N S2 D2 Critical paths C O 21

EMI Mitigation by PCB Layout Critical Path Area Reduction High di/dt Caps BUCK Example + Grounding - SW Node FETs & Driver Bypass Caps in High di/dt loop should be placed as close as possible to the switching components Low side FET SOURCE should be connected as close as possible to the input capacitor Apply to critical paths in other SMPS topologies 22

Lower EMI can be achieved by Place capacitors on same side of board as component being decoupled Locate as close to pin as possible Keep trace width thick and minimized in Ground Terrible! Good Better Best Connecting to decoupling capacitors in out out output return Ground output return Good Connecting to output capacitors 23

EMI Mitigation by PCB Layout Critical Path Area Reduction Grounding High di/dt Caps SW Node FETs & Driver Switch node SW swings from V IN or V OUT to ground at Fsw. = very high dv/dt node! = electrostatic radiator! Requires a contradiction: As large as possible for current handling, yet as small as possible for electrical noise reasons Solutions: Switch node short and wide Minimum Copper Width Requirement: Roughly 30mils/Amp for 1 Oz Cu and 60 mils/amp for ½ Oz Cu 24

EMI Mitigation by PCB Layout Critical Path Loop Reduction Grounding High di/dt Caps SW Node FETs & Driver Contradiction on SW node transition rate: Faster Rising and Falling Times = Less Losses = Higher EMI Resistor Value: Start with 1-10 ohms and adjust from there 25

EMI Mitigation by PCB Layout Critical Path Loop Reduction Grounding Ground Plane Return Current takes the least IMPEDANCE path Unbroken Ground Plane provides shortest return path image current return path: Trace or Cut on the ground plane Current flow in top layer trace Ground Plane Ground Plane Return current path in unbroken ground plane directly under path: Area minimized & B field minimized Return current path enclose much larger area if the direct path is blocked! 26

Conduction EMI Common mode noise Key parameters: 1. C ps. 2. V ps. 27

Conduction EMI Differential mode noise Key parameters: 1. ESL of Cbus. 2. EPC of L, L pfc. 3. V ds dv/dt. 28

The Usual Suspects - Noise Sources Input Ripple Current Inter-winding Capacitance Stray Capacitance from High DV/DT Surfaces to the Outside World 29

Conduction EMI Lower transformer C PS Target: lower CPS to reduce CM noise. Possible actions: 1. Increase the distance between primary and secondary. Side effect: larger leakage and larger losses. 2. Decrease the facing area between primary and secondary. Side effect: larger leakage and larger losses. 3. Shielding. Side effect: increase cost and need more space. 4. Suitable terminal connection: easy and a must do! 30

Conduction EMI Better transformer winding Original design Better design Original design Better design 31

Typical Mitigation Techniques Filtering for Differentialmode Noise Shielding Techniques Inside Transformer Common-mode Choke And Y-Cap to reduce Common-Mode Noise Snubber to Reduce Ringing 32

Rectifier Location in Flyback Rectifier in return lead of transformer CIN/CEMI/COUT couple dot end of primary and non-dot end of secondary to 0 Vac Maximum voltage potential between windings AC current flows in transformer capacitance, resulting in common mode current flow and EMI issues CIN 0 Vac 0 Vac CEMI COUT Iac 0 33

Rectifier Location in Flyback Rectifier in positive lead of transformer CIN/CEMI/COUT couple dot end of primary and dot end of secondary to 0 Vac No voltage potential between windings No AC current flows in transformer capacitance, no common mode currents, less EMI 0 Vac 0 Vac Iac = 0 34

Conducted EMI Test Setup 35

Compliance Test Procedure Start with Peak Detector measurement If Peak measurement is below AVG and QP, no need for further testing Only test AVG and QP at frequencies where Peak measurement is above AVG/QP limits 36

Compliance Testing Data Example Just Barely Failed 37

What Scan to Use for Testing PMP Boards? Scan Type Time Per Scan Time for Complete Set of Scans Average Detector ~1 hour 4-5 hours Quasi-Peak Detector 1-2 hours 6-8 hours Peak Detector <1 minute 5 minutes Peak Detector Max- Hold 1-5 minutes 10-20 minutes 38