Locking a Door Unlocked by a Schedule using a Card

Similar documents
Access Control & Burglar Alarm Integration with KT-300

MTP: Continuous User Authentication on Android Using Face Recognition

AS-525. AxTrax Access Control Management Software. Software Manual

5.6.2 Optional Lab: Restore Points in Windows Vista

NetworX TM NX-8E Alarm Panel. Application Note. NetworX NX-8E. 1.0 The NetworX NX-8E Alarm Panel

Configuring Network Load Balancing with Cerberus FTP Server

Using triggers and actions

Access Control Interface Module D9210C. Program Entry Guide

Configuring Napco Integration

Connection and Configuration of Baudisch SIP unit with Display and RFID Reader Module

Intelli-M Access Quick Start Guide

Access Control in Surveillance Station 7.0

OnGuard Online User Guide

Access Control Unit User s Guide

Allegion PIM-400/485 and AD-400 Installation Application Note. 1.0 Hardware Requirements. 2.0 Software/Licensing Requirements

Vehicle Security System VSS3 - Alarm system remote. System Setting Guide - English

YOUR INTERACTIVE SECURITY

Quick Installation Guide LCD GSM ALARM SYSTEM LH

GSM Autodialer Professional GJD700 Speech & Text Autodialer

HAI Access Control. The HAI Access Control Card Reader can be used for:

How to Configure Alarm Notification

Config software for D2 systems USER S MANUAL

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Versions Addressed: Microsoft Office Outlook 2010/2013. Document Updated: Copyright 2014 Smarsh, Inc. All right reserved

Setting Up the EntraPass Mirror Database and Redundant Server

Outlook Profile Setup Guide Exchange 2010 Quick Start and Detailed Instructions

Seamless and Secure Access (SSA) Manual Configuration Guide for Windows Mobile 6.1

Lab: Data Backup and Recovery in Windows XP

2012 November. AxTraxNG Access Control Management Software Software Manual (Version 21.x)

Rational Quality Manager. Quick Start Tutorial

INSTALLATION MANUAL XM3 Reader

Outlook 2010 Setup Guide (POP3)

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Yale Software Library

Allegion AD-300 Installation Application Note. 1.0 Hardware Requirements. 2.0 Software/Licensing Requirements

7. Lenel Job Aid: Running Reports

How to Configure Alarm Notification

User Guide for TASKE Desktop

INF-USB2 and SI-USB Quick Start Guide

Lab - Data Backup and Recovery in Windows XP

Using Bluetooth-Enabled PosiTector 6000 with Statistical Process Control Software

SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions

TC 3/10 Rev. A

NT500 Offline Getting Started Guide

FALCON WORLD CLASS SECURITY. Advanced Alarm System for Vehicles with CAN-Bus. Installer Manual NATIONWIDE INSTALLATION SERVICE

Windows XP Manual Installation

How to Set Up Outlook 2007 and Outlook 2010 for Hosted Microsoft Exchange if the Program is Already Installed

B.A.S.I.S. Offline Setup Guide

High Performance Access Control and Integrated Security Systems

The Access Engine. Building Integration System - The Access Engine. Security Systems

MONAHRQ Installation Permissions Guide. Version 2.0.4

GSM Voice Auto Dialer& SMS sender JC-999. User Manual

Optional Lab: Install, Configure, and Partition a Second Hard Drive in Windows Vista

PAC1 Door Access Controller

Apps for Android. Apps for iphone & ipad INS584-3

D8X / D16X IPHONE INTERFACE

If you are unable to set up your Linksys Router by using one of the above options, use the steps below to manually configure your router.

Quick Start Guide. GV-AS Controller

BioWin Network Installation

Installation Guide and Machine Setup

DC-8706K Auto Dial Alarm System

CipherLab 5100 Time Attendance Utility Manual

e-ask electronic Access Security Keyless-entry

Bosch Alarm Panel Interface Manual

Doors in a Network Environment

THRUST CURVE LOGGER V-4.200

SCORPION. micron security products

AVS A4 alarm Owner s manual

Access Control and Security Management Software User Manual

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

LiNC-Ez iam TM Programming Manual REV: H

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Installation Instructions

Use the below instructions to configure your wireless settings to connect to the secure wireless network using Microsoft Windows Vista/7.

LP 2844 Thermal Printer

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS

Volume. EverAccess. User s Manual

EMBEDDED ACCESS CONTROL Hardware Installation Guide

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

Access Control Management Software

User s Manual for Fingerprint Door Control Software

INS580. Apps for Android. Android is a trademark of Google Inc.

Matrix 424/832/832+ ICON & LCD User Manual. Software Version 5 RINS EN Security Grade 2 Environmental Class 2

B.A.S.I.S. G and V Offline Setup Guide

S-IA-PRO Intelli-M Access Professional V4.0

Configuring Your Network s Security

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

How to Program a Commander or Scout to Connect to Pilot Software

The FlexiSchools Online Order Management System Installation Guide

Vantage Point Access Control Software

Active Directory (AD) Self-Service

Reference Manual Access Control and Security Management Software

GE Simon XT Quick User Guide

Please refer to the guide below to use the latest Android version of the UCam247Live app.

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

GLOSSARY of SECURITY TERMS

Basic Mercury Powered NXT Configuration in Doors.NET TM Application Note. 1.0 Adding an NXT-MSC Controller to the NXT Gateway

Cloud Services ADM. Agent Deployment Guide

Keypad Programming Instructions for the Profile Series LK and v.g1 Locks

Transcription:

Objective Locking a Door Unlocked by a Schedule using a Card This document shows you how to configure EntraPass to unlock a door using a schedule (with or without the First Man In feature) and re-lock before the schedule ends by presenting a card to the reader and pressing a button. An external alarm system will be used to illustrate our purpose. Requirements Running EntraPass software with defined access levels Door connected to a KT-300 controller An external button installed next to the reader (or keypad button such as * or # with the P225KP or P325KP) 2 pieces of wire (Jumpers) Steps 1. Connect the hardware as shown below 2. Connect the controller, then configure the controller using the Express Setup utility 3. Define the desired schedules (Definition > Schedules 4. Define the required relays (Devices > Relays) 5. Define the required inputs (Devices > Inputs). 6. Define the door and external alarm system options (Devices >Doors). Telephone: 1 (450) 444 2030 Toll free: 1 888 222-1560 Fax: 1 (450) 444 2029 Internet: www.kantech.com page 1 / 8

Step by Step Instructions 1. Connect the external push button and the 2 jumpers as illustrated by the following diagram. 2. Access EntraPass to configure the KT-300 controller and define door contacts and REX (refer to the EntraPass reference manual for details on how to configure controllers using Express setup). Telephone: 1 (450) 444 2030 Toll free: 1 888 222-1560 Fax: 1 (450) 444 2029 Internet: www.kantech.com page 2 / 8

3. Define the schedule during which the door will be unlocked: Definition > Schedule. 4. Define the two (2) onboard output relays: Devices > Relays. Identify the first one as Request to arm (lock) and the second as Request to disarm (unlock). Leave the default values. Telephone: 1 (450) 444 2030 Toll free: 1 888 222-1560 Fax: 1 (450) 444 2029 Internet: www.kantech.com page 3 / 8

5. Define the three (3) required inputs: Devices > Input. Assign an Always valid schedule to all the defined inputs. 5.1 Select input # 5 and label it Request to arm input. Leave the default value unchanged and save. 5.2 Select input # 6 and identify it as an Arming status input, set it for normally Opened and save. Telephone: 1 (450) 444 2030 Toll free: 1 888 222-1560 Fax: 1 (450) 444 2029 Internet: www.kantech.com page 4 / 8

5.3 Select input # 7 and label it Shunt request to arm. Leave it to normally Closed. 5.4. Select the Relay and Input tab and select relay 1 for the Activate relay field, then assign Input 6 as the Shunt input and save. Telephone: 1 (450) 444 2030 Toll free: 1 888 222-1560 Fax: 1 (450) 444 2029 Internet: www.kantech.com page 5 / 8

6 Go to Devices > Door to bring up the door definition window. Select the door you want to define for this application. 6.1 Assign the Unlock schedule for this door. This is the schedule defined earlier in Step 3. Select the Options and alarm system tab. 6.2 Check the Unlock door by schedule after first access granted option. Telephone: 1 (450) 444 2030 Toll free: 1 888 222-1560 Fax: 1 (450) 444 2029 Internet: www.kantech.com page 6 / 8

6.3 Click the External alarm system options button. 6.4 Assign Input 5 as the Arming request input. 6.5 Select the Always valid schedule as the Enable Arming request schedule. 6.6 Under the Arming access level field, select the access level or the group of access levels for the cardholders who will have permission to relock the door after the door was unlocked by a schedule. 6.7 Check the Wait for access granted to arm checkbox. 6.8 Check the Re-Lock door on request to arm checkbox. 6.9 Select Input 6 as the External alarm system panel status input. 6.10 Select the Input tab. 6.11 Check the Shunted on exit and Shunted on disarm checkbox for input 7. Telephone: 1 (450) 444 2030 Toll free: 1 888 222-1560 Fax: 1 (450) 444 2029 Internet: www.kantech.com page 7 / 8

6.12 Select the Postpone arming tab. 6.13 Assign the access level or group of access level of the cardholders who will be allowed to unlock the door by schedule (first people in) under the Postpone or disarm access level field. 6.14 Select the Relay tab. 6.15 Assign relay # 1 as the Arming alarm panel Exit delay. 6.16 Assign relay # 2 as the Disarming alarm panel Entry delay. 6.17 Click OK and save the door definition. Telephone: 1 (450) 444 2030 Toll free: 1 888 222-1560 Fax: 1 (450) 444 2029 Internet: www.kantech.com page 8 / 8