Assembly. Front view. LED red: Fault. Switch HiDMux2700. Mux/ HART ...

Similar documents
PROCESS AUTOMATION FLEXIBLE ASSET MANAGEMENT HART INTERFACE SOLUTIONS

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

SAFETY MANUAL SIL Switch Amplifier

SAFETY MANUAL SIL RELAY MODULE

Rosemount 333 HART Tri-Loop

TX OPEN RS232/485 module

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Inductive sensor NI10-M18-Y1X-H1141

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

SAFETY MANUAL SIL SMART Transmitter Power Supply

Modular I/O System Analog and Digital Interface Modules

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

PCS0100en Persy Control Services B.V. Netherlands

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

2002 IS Catalog. Page

HARTING econ 3000 Introduction and features

Permissible ambient temperature Operation Storage, transport

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Digital input modules

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

Panel Meters and Controllers Modular Panel Meter Type EDM 35

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

SYSTEM DESCRIPTION Termination Boards

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

NC-12 Modbus Application

Rosemount 333 HART Tri-Loop

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

S-series DeviceNet Interface Card

Current Loop Application Note 1495

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

650W Single Output Power Supply

DATA SHEET. TDA1518BQ 24 W BTL or 2 x 12 watt stereo car radio power amplifier INTEGRATED CIRCUITS

Telephone- and leased line modem for industrial applications TD-36

S-series Mass Connection Solutions

TX2123 RS485 TO ETHERNET ADAPTOR

M-series FOUNDATION Fieldbus I/O

S-series SQ Controller

is then retained absolutely without interruption.

DATA SHEET. TDA8560Q 2 40 W/2 Ω stereo BTL car radio power amplifier with diagnostic facility INTEGRATED CIRCUITS Jan 08

HARTING mcon 3000 Introduction and features

How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip

ZC-24DO CANopen I/O Module: 24 Digital Outputs

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Inductive slot sensor

Rack mounted telephone- and leased line modem for industrial applications

Technical Data. Dimensions

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

USB-to-CAN V2 compact

Technical Data. Dimensions

Waveguide Access Point WGA631. Product Guide

SAFETY MANUAL SIL SWITCH AMPLIFIER

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

OZW30. Central Unit SYNERGYR

Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Safety technique. Emergency stop module BO 5988 safemaster

Voltage Regulator SPAU 341 C. Product Guide

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Repeaters and Mimics Data Sheet

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

II Intelligent PC/CAN Interface. Manual

Manual Serial PCI Cards

Application Note TMA Series

M-Bus-Logger Data Logger

PROFIBUS Links & Coupler

Optocoupler, Phototransistor Output, Dual Channel, SOIC-8 Package

DeltaV SISnet Repeater

EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

CP Page 1342 Mar 2008 Siemens ITS

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

1701/22 FieldMonitor Management Interface Module

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

Smart DeviceNet Remote I/O Terminals

The CP provides access to different communication services of the PROFIBUS bus system:

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Product Specification. 1000BASE-T RoHS Compliant Copper SFP Transceiver FCLF8520P2BTL / FCLF8521P2BTL / FCLF8522P2BTL

Transcription:

HART Multiplexer Master Features Assembly 32-channel 24 V DC supply HART field device inputs RS 485 interface Up to SIL3 acc. to IEC 61508 Front view PWR LED green: Power supply Function LED red: Fault FAULT HART TX LED yellow: HART transmission The HART Multiplexer Master provides 32 signal channels for connection to SMART transmitters or control devices supporting digital communication according to the HART standard. Full three-port isolation is included and each input channel has dual capacitor isolation for freedom of loop connection. Each HART Multiplexer Master is networked simply by connecting the high-speed RS 485 output in a multidrop configuration. The device interrogates each field device, under the supervision of the workstation, retrieving information for storage in its internal database, which is then easily accessed. This module is intended to mount on an HiD Termination Board or HART Communcation Board. Also special boards for DCS integration are available. For additional information, refer to the manual and www.pepperl-fuchs.com. Switch 1... 8 MUX 2700 32 Channel Hart Multiplexer OFF 3 Connection 1 2... 32 Mux/ HART RS 485 I/F + - RS 485 24 V DC Zone 2 Div. 2 Pepperl+Fuchs Group Tel.: Germany +49-621-776-0 USA +1-330-4253555 Singapore +65-67-799091 Internet www.pepperl-fuchs.com 1

Supply Connection via Termination Board Rated voltage 20.4... 30 V DC via Termination Board Rated current 28 ma at 24 V, RS 485, quiescent current Power loss 0.7 W at 24 V HART signal channels Number of channels 32 Signal range 0.12 V pp < signal < 1.5 V pp Leakage current < 3 µa at -20... 85 C (253... 358 K) Terminating resistor external 230... 500 Ω standard (up to 1000 Ω possible) Output voltage Output resistance DC isolation Common mode voltage Input impedance Input voltage range Common mode voltage Differential mode clamping Common mode clamping Carrier detect level Transmit amplitude Device type Impedance Data link type Field multi point support Interface Transfer rate Address Type Toplogy Electrical isolation Interface/power supply Interface/field channels Power supply/field channels Indicators/settings Display elements Operating elements 400 mv pp (with the terminator resistance specified above) 100 Ω or smaller, capacitive coupling dual capacitor each channel up to 30 V > 5 kω, according to HART specification 0.12... 1.5 V pp 30 V ± 5.2 V, for transient or AC signals ± 10 V, for transient or AC signals signal > 0.12 V pp, carrier detection activated signal < 0.08 V pp, carrier detection not activated 200 Ω load, 0.43 V pp < signal < 0.49 V pp 500 Ω load, 1.1 V pp < signal < 1.2 V pp DC isolated bus device high impedance HART primary and secondary option available upon request 9600 MBit/s, 19200 MBit/s or 38400 Mbit/s, selectable via switch 1... 31, adjustable via DIP switch RS 485, differential pair and grounding multi point, master/slave connection 1400 V rms 500 V rms 1400 V rms LED PWR (power supply), one green LED LED HART TX (HART transmission), one yellow LED LED FAULT (lead fault), one red LED DIP switches at the housing side for: - unit slave address - baud rate - test mode on/off Directive conformity Electromagnetic compatibility Directive 2004/108/EC EN 61326-1:2006 Conformity Protection degree IEC 60529 Ambient conditions Ambient temperature 0... 60 C (273... 333 K) Storage temperature -40... 70 C (233... 343 K) Relative humidity 5... 95 %, non-condensing Mechanical specifications Protection degree IP20 Material Polycarbonate Mass approx. 140 g Dimensions 18 x 106 x 128 mm (0.7 x 4.2 x 5 in) Data for application in conjunction with hazardous areas Declaration of conformity Pepperl+Fuchs Group, category, type of protection, II 3G Ex na II T4 temperature classification International approvals CSA approval 1256050 Approved for Class I, Division 2, Groups A, B, C, D; Class I, Zone 2, IIC Pepperl+Fuchs Group Tel.: Germany +49-621-776-0 USA +1-330-4253555 Singapore +65-67-799091 Internet www.pepperl-fuchs.com 2

General information Supplementary information Statement of Conformity, Declaration of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. Pepperl+Fuchs Group Tel.: Germany +49-621-776-0 USA +1-330-4253555 Singapore +65-67-799091 Internet www.pepperl-fuchs.com 3

Configuration Address Baud rate Switch 1... 8 SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 FAULT PWR HART TX MUX 2700 32 Channel Hart Multiplexer OFF RS 485 baud rate SW6 SW7 SW8 9600 OFF OFF OFF 19200 OFF OFF 38400 OFF OFF RS 485 address SW1 SW2 SW3 SW4 SW5 1 OFF OFF OFF OFF 2 OFF OFF OFF OFF 3 OFF OFF OFF 4 OFF OFF OFF OFF 5 OFF OFF OFF 6 OFF OFF OFF 7 OFF OFF 8 OFF OFF OFF OFF 9 OFF OFF OFF 10 OFF OFF OFF 11 OFF OFF 12 OFF OFF OFF 13 OFF OFF 14 OFF OFF 15 OFF 16 OFF OFF OFF OFF 17 OFF OFF OFF 18 OFF OFF OFF 19 OFF OFF 20 OFF OFF OFF 21 OFF OFF 22 OFF OFF 23 OFF 24 OFF OFF OFF 25 OFF OFF 26 OFF OFF 27 OFF 28 OFF OFF 29 OFF 30 OFF 31 Pepperl+Fuchs Group Tel.: Germany +49-621-776-0 USA +1-330-4253555 Singapore +65-67-799091 Internet www.pepperl-fuchs.com 4

Additional information Conformity The HART Multiplexer Master generally complies with the HART FSK physical layer specification rev. 8.0 available from the HART Communication Foundation. HART is a registered trademark of the HART Communication Foundation. High specification front end design Two decoupling capacitors are provided, one for each signal connection. Both the positive (+U e ) and the negative (-U e ) signal wires are therefore decoupled from DC signal. Only the high frequency digital HART protocol signal passes through to the internal multiplexer circuitry. Failure of any one capacitor from either a short circuit or open circuit means that availability of 4 ma... 20 ma control signal will not be affected. no DC loading of 4 ma... 20 ma control signal no single point of failure high noise immunity The max. 30 V DC input voltage (specified between all terminals, both belonging to the same channel or not) makes it possible to connect any multiplexer terminal to whatever voltage level can be derived from a 24 V DC supply, +20 % tolerance included. Three port isolation The three port isolation structure of the HART Multiplexer Master is depicted in the previous page. As you can see, both the 24 V supply input and the RS 485 serial interface are isolated from the HART section, i. e. from the HART signals on the field devices. This is full galvanic isolation, implemented either by transformer or by optocoupler. Self contained architecture Each HART Multiplexer Master module is a stand alone device containing all necessary hardware to communicate with up to 32 HART protocol enabled field devices and a host PC via RS 485 interface. The advantages are: fast polling one module design RS 485 direct from module no communications bottleneck ideal for valve diagnostics Wide software compatibility The HART Multiplexer Master is fully compatible with F-R AMS (Ver 5.0 is also an OPC server), Valve Link and Cornerstone. Additional compatibility extends to HART OPC server software available from HCF (HART Communication Foundation). Allowing users to write dedicated applications for their specific needs. Fully tested, by all key PAM vendors. Pepperl+Fuchs Group Tel.: Germany +49-621-776-0 USA +1-330-4253555 Singapore +65-67-799091 Internet www.pepperl-fuchs.com 5