3 Phase Simplex Control Panel Grinder & Vortex Pumps

Similar documents
Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

DC400 Dispensing Cutoff System

OPL BASIC. Dosing System for Professional Laundry machines. Contents

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

INSTALLATION INSTRUCTIONS

For Models #6-5001, #6-7501, # & #10-12K1

TMS TANK MANAGEMENT SYSTEM

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Single Phase Soft Starter

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

FAQ s on Siemens Magmeters

Water Leak Detection System

TSn SERIES Surge Protective Device

WGL20, WGL20H, WGL20F Grinder Pumps

PART 1 - INTRODUCTION...

Installation, Operation and Maintenance Manual

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Magnetic Starter - 30A, 120/240V Coils

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

12 Volt 30 Amp Digital Solar Charge Controller

Part I - Installation

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

, User s Manual

Streaming Potential System (SPT1000, SPD1000)

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Digi-Motor Installation Guide

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

Owner's/Installation Manual

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Safety, Operation and Maintenance Manual with Parts List

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Oil and Coolant Circulating Heating System. Model - OCSM

What is a multimeter?

Warrick Series DMS-470/570 Montoring Panels Installation and Operation Bulletin

GENERATOR TRANSFER SWITCH

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR WARNING VDC

Manual for Fire Suppression & Methane Detection System

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Operating Instructions

! WARNING. Before using product, read and understand instructions.

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

MODELS WG/WGX20* GRINDER PUMP. *Used in Hazardous Locations Class I, Division 1, Groups C & D INSTALLATION AND SERVICE MANUAL

R02GA. July 31, Dear Blue Bird Owner:

HM-W536 Install Guide

Control Box Wiring For PRSstandard Tool

i ChatterBox! Motorcycle Security

PRO PLM Installation Instructions

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

WE-350 Series ¼ Turn Electric Actuator

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Comfort Control Relay Panel (CCRP)

8146/5 Series Breaker Panelboards

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

AC-115 Compact Networked Single Door Controller. Installation and User Manual

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

PDS-375-TR Touring CB Power/Data Supply Operator s Manual Rev 1.2

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

HQ Series ¼ Turn Actuator

Light Source User Guide

19 LED Tube Controller ORDERCODE 41003

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

E2 Series Electric Furnaces

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

SECURITY SYSTEM ADP-CAN

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...


Operating Instructions

AMERBRITE UNDERWATER WHITE LED POOL LAMP

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

Explosion proof enclosures

GeniSys 12V. Model Description / Applications. Advanced 12 Vdc Burner Control

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

POWER TRIM 5 F AUTO TRIM AND AUTO TRIM

SECTION LOW VOLTAGE LIGHTING CONTROLS

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

PUSH BUTTON START INSTALLATION MANUAL

SOLAR POWER - THE NEW WAY TO RV!

ATL Fuel Level Sender Probes

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Fire Pump Controllers Remote Alarm Panels

Fire Fighter Phone System Installation Instructions

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Transcription:

Introduction Before proceeding with the installation or operation of the control panel read all instructions thoroughly as well as comply with all Federal, State and Local Codes, Regulations and Practices. The control panel must be installed by qualified personnel familiar with all applicable local electrical and mechanical codes. Refer to the National Electrical Code (NFPA 70). Failure to properly install and test this product can result in personal injury or equipment malfunction. All conduit connected to the panel must be sealed with conduit sealant to prevent moisture or gases from entering the panel. NEMA 1 enclosures are for indoor use only while NEMA 4X panel enclosures may be used indoors or outdoors. Refer to panel model name-plate on inside of door for enclosure rating. Note: If options are ordered that affect the number of floats, refer to the panel schematic for complete information. This Is Used With The Following Pumps G2DT-43 G2D-43 V1D-43 G2DT-03 G2DT-23 V1D-23 V15D-43 V2D-43 G2D-03 G2D-23 G3D-43 V1D-03 V15D-03 V15D-23 V2D-23 V3D-43 G5D-43 G3D-03 G3D-23 V3D-03 V3D-23 V5D-43 V7D-43 G5D-03 G5D-23 Safety Guidelines 1. DO NOT USE WITH FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS GASOLINE, FUEL OIL, KERO- SENE, ETC. DO NOT USE IN EXPLOSIVE ATMOSPHERES. CONTROL PANEL SHOULD ONLY BE USED IN WATER AND WASTEWATER APPLICATIONS THAT ARE NOT RATED AS A HAZARDOUS LOCATION. 2. DO NOT WORK ON THE CONTROL PANEL WITH LIVE VOLTAGE APPLIED TO THE CONTROL PANEL WITH WET HANDS OR WHEN STANDING ON A WET SURFACE. 3. DISCONNECT ALL ELECTRICAL SERVICE BEFORE WORKING OR HANDLING THE CONTROL PANEL. 4. INCOMING VOLTAGE MUST MATCH THE CONTROL PANEL VOLTAGE. REFER TO THE PANEL SCHEMATIC FOR COMPLETE INFORMATION. Installation of the : 1. Determine mounting location for the control panel. If splicing is required between the level switches and the panel, we recommend a junction box. CAUTION! Use conduit sealant and waterproof wire nuts for connections. Make sure all connections are water tight. 2. Determine conduit entrance locations on control panel and install per local codes. Check schematic and determine number of power sources required. Use conduit sealant on all conduits to prevent moisture and gases from entering control panel. 3. Connect control/alarm and pump power conductors to the proper terminals. The schematic and terminal blocks will be labeled for proper connection. 4. Verify correct panel operation after installation of panel, power and level switches are complete. Page 1 of 10

Blue 3 Phase Simplex Connecting the Pump and Thermal Wires: Your pump has 5 colored wires. White, Black, Red, Blue and Orange Pump Connection: The White, Black and Red wires connect to the terminal block labeled Pump #1 Pump Connection. The pump leads are connected to T1, T2 and T3. WARNING! After wiring a 3 phase control panel YOU MUST CHECK THE PHASE ROTATION. The wire leads may need to be reversed to match rotation. Refer to your pumps O&M manual for more information. Pump 1 Thermal Sensor: The remaining two wires will be Blue and Orange. They are connected to the terminal block labeled Pump 1 Thermal Sensor. BL=Blue, OR=Orange The Blue wire is connected to #7 and the Orange wire is connected to #8. Pump Lead T1 Pump Lead T2 Pump Lead T3 Thermal Overload Blue to 7 Thermal Overload Orange to 8 Pump BL OR BK YW Testing the Thermal Sensor: #1. Put one ohm meter probe on the Blue wire and one on the Orange wire. #2. If the reading is 0 or near 0 the thermal sensor is good. 0 If the reading is OL the pump has been or currently is overloaded. Orange Page 2 of 10

Pump 1 Seal Fail Probe: (Seal Fail may not be an option on your pump) The Seal Probe wires are connected to terminals 9 and 10 which are labeled Pump 1 Seal Sensor. The Black wire from the Seal Probe is connected to terminal 9 which is labeled BK for Black. The Yellow wire from the Seal Probe is connected to terminal 10 which is labeled YW for Yellow. Seal Probe from pump Seal Fail may not be an option on your pump. Black Seal Sensor to BK 9 BL OR BK Yellow Seal Sensor to YW 10 YW Testing Seal Fail Probes: #1. Put one ohm meter probe on the Black wire of the sensor. #2. Place the other ohm meter probe on the Hex Nut portion of the sensor. The ohm meter should read continuity or close to zero ohms, If it reads open or High ohms then the sensor is defective. #1. 0 0 #3. Put one ohm meter probe on the seal probe. #2. #4. Place the other ohm meter probe on the yellow wire. The ohm meter should read continuity or close to zero ohms, If it reads open or High ohms then the sensor is defective. Sensor is good: Sensor is good: Page 3 of 10

Setting the MPS (Motor Protective Switch): The MPS is used for pump short circuit and overload protection. #1. Use a screw driver to set the yellow dial on the MPS (Motor Protective Switch) to the FLA (Full Load Amps) of the pump. i.e. If your pumps FLA is 6.3 set the yellow dial to 6.3. #2. When the panel is ready for operation, place the switch in the on position by turning the switch clockwise to the 12 o clock position. #2. #1. Test the MPS (Motor Protective Switch): To test the MPS: #1. Turn the switch to the On or 12 o clock position. #2. Place a screw driver in the test slot. #3. The switch should snap to the Off or 9 o clock position. #1. #2. #3. Re-Setting the MPS (Motor Protective Switch): To Re-Set the MPS turn the switch back to the On or 12 o clock position. Tripped Reset Page 4 of 10

Mounting Level Switches: Float switches are most commonly used, but 3 Phase Grinder & Vortex control panels can be used with any dry contact type level or pressure switch. The Illustration below shows float switches installed for Pump Down applications. Refer to float switch instructions for mounting of pipe clamp or weighted floats. Float switches are labeled on both bouy end and cord end for easy installation. Stop 1 & 2 Start Float Stop 1 & 2 Stop/Off Float Normal Float switch function as tank fills: Alarm Float Start Float Normal Float switch function as tank empty s: Start Off Pump Starts Pump continues to run Pump continues to run Pump turns off Abnormal Float switch function as tank fills: Abnormal Float switch function as tank empty s: Alarm Float Start Float Start Off Pump Starts Alarm Sounds, Pump continues to run Alarm turns off, pump continues to run Pump continues to run Pump turns off Page 5 of 10

Field Wiring Connections: 3 Phase Simplex Grinder & Vortex control panels are multi voltage. #1. Set the transformer voltage to match incoming power voltage. #2. Connect the incoming power. #1. Setting the Transformer: #1. Set the transformer voltage to match incoming power voltage. WARNING! Incoming power must be off when wiring the transformer. Remove the label from the (field installed) red wire after verifying which voltage terminal the wire is supposed to be connected to. The incoming voltage has to match the transformer voltage or DAMAGE WILL OCCUR. 460 230 208 0 - (Field installed) red wire (Factory installed) red wire #2. Connecting the Incoming Power: #2. Connect your incoming power to L1, L2 and L3 Incoming Power WARNING! After wiring a 3 phase control panel YOU MUST CHECK THE PHASE ROTATION. The wire leads may need to be reversed to match rotation. Refer to your pumps O&M manual for more information. Page 6 of 10

for Grinder and Vortex Pumps Simplex Circuit Board Command Center 3. 4. 5. 6. 1. 2. There is one HOA (Hand-Off-Auto) switch. This HOA switch is also used as the System Test switch for diagnosing the control panel. Two green power on indicators provide visual indication for the control and alarm fuses. Fuses must be replaced with 1 amp fast acting 5mm X 20mm fuses. The Pump Run indicator light is green. If this light is illuminated the pump is running. The Stop float, Start float and Alarm float indicator lights are red. Circuit Board Terminal Blocks: 3 Phase Simplex Grinder & Vortex control panels use two terminal blocks for alarm mode configurations. An 8 position main terminal block is for power and level switch connections. A separate 3 position terminal block is used for dry auxiliary contacts. A 5 amp, 120 VAC max load can be applied to the auxiliary terminals. The auxiliary contacts are Form C, Single Pole, Double Throw. (Common, Normally Open, Normally Closed). Contacts change state when in alarm condition. 8 position terminal block Auxiliary contact terminal block Page 7 of 10

for Grinder and Vortex Pumps 3 Phase Simplex - How to use the System Test switch #1. Check the incoming power on the top of the command center. Fuses are good. If the indicator lights are illuminated the fuses are good. If one or both of the indicators are not illuminated the fuse or fuses need to be replaced. If the fuse or fuses do not fix the problem the incoming power needs to be examined. Alarm Fuse needs to be replaced Control Fuse needs to be #2. View the current status of your system. The indicator lights illuminate as each float rises with the liquid level in the tank. #1. #2. Start Float Stop Float Start Float Stop Float All three floats are not activated. Only the Control Power and Alarm Power indicator lights should be illuminated. #3. Start Float Stop Float If the Stop float is activated the Stop light will illuminate. Start Float Stop Float #4. The Stop float and the Start float are activated so the Stop float and the Start float indicator lights are illuminated. All floats are up so all indicators are illuminated. Page 8 of 10

for Grinder and Vortex Pumps 3 Phase Simplex - How to use the System Test switch #3. Operating the pump manually with the HOA (Hand-Off-Auto) Place the HOA (Hand-Off-Auto) switch in the pump on manually. Hand position to turn the 1 Phase Simplex command center Place the HOA (Hand-Off-Auto) switch in the the pump off from operation completely. Off position to turn Place the HOA (Hand-Off-Auto) switch in the Auto position to turn the pump with float control. When the water level raises the stop and start float the pump turns on and stays on until the stop float drops down. If the liquid raises the high level float a visual and audio alarm will trigger. Page 9 of 10

for Grinder and Vortex Pumps 3 Phase Simplex - How to use the System Test switch #4. Using the System Test switch to troubleshoot your control panel. Fig. #1. Place the HOA (Hand-Off-Auto) switch in the Hand position. The Pump Run indicator light will illuminate and turn on the pump. Place the HOA (Hand-Off-Auto) switch in the Hand position and you will be automatically checking the true status of the floats. EXAMPLE: Fig #2. The green pump run light is illuminated because the HOA switch is in the hand mode. Fig. #2. Fig. #2A. EXAMPLE: Fig#2A The Start float indicator is illumi- The Stop float indicator light is not. Illustration (Fig#3A) shows the Stop float is activated, but the indicator light on the command center in (Fig#2A) is not illuminated. The Stop float is not working properly and should be replaced. EXAMPLE: Fig#2B The same indicator lights are illuminated. The Start float indicator is illumi- The Stop float indicator light is not. Example (Fig#3B) shown below is demonstrating that the same float is not working, but for a different reason. In this example the float is hung up in the tank. (Fig#3A) Start Float is activated Stop Float is activated (Fig#3B) Start Float is activated Stop Float is NOT activated Page 10 of 10