SENTINEL ENTERAL FEEDING PUMP USER TRAINING PACKET

Similar documents
OPERATOR S MANUAL Vet Pump

with FLASH TIPS PLUM A+ INFUSION SYSTEM OPERATING INSTRUCTIONS REFER TO SYSTEM OPERATING MANUAL FOR COMPLETE OPERATING INSTRUCTIONS

ENTERALITE INFINITY PUMP Instructions for use

Regents of the University of Michigan 5/7/2015. Review pump functionality, sets and accessories Understand key process steps for

JORVET INFUSION PUMP J1060M OPERATOR MANUAL

BLOOD COLLECTION MIXER

Operating Manual. Kangaroo TM. Joey Enteral Feed and Flush Pump with Pole Clamp, Progammable

Covering the Spectrum

The phone key, which starts and ends a call. The phone number is prefaced by 1: or 2:, which indicates the line currently in use.

MAINTENANCE & TROUBLESHOOTING

Insulin Delivery System. Reference Guide

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Back-UPS Pro 1300/1500 Installation and Operation

Stove Guard Kit User Manual

Infusovet Veterinary Infusion Pump

site monitoring Kit Site Monitoring Kit User Manual we prove it.

CADD-legacy PCA pump Model ml Cassette

Before you start. How to use this Guide Use this Key to identify what a button or status display looks like in an instruction sequence.

CarePartner Telephone With Reminders

A small, safe, reliable and user-friendly device suitable for inpatient and outpatient use in a variety of applications

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

BeoCom 2. Get started

Operating Manual. Kangaroo TM. Epump Enteral Feed and Flush Pump with Pole Clamp, Programmable

W850. Maintenance Guide

owner s manual EDGE 200 GPS-ENABLED CYCLING COMPUTER December _0B Printed in Taiwan

Automatic Phone-Out Home Monitoring Systems

HP ProDisplay P19A LED Backlit Monitor. User Guide

MAINTENANCE & TROUBLESHOOTING

Single Day Alarm Clock with. Bluetooth and USB Play-through

SYMBOL MC9060 HAND HELD TERMINAL USER MANUAL

How To Program An Autodialer

Deluxe Bottle Warmer

ReSound Unite TV FREQUENTLY ASKED QUESTIONS. Setup & Configuration. Use & Operation. Troubleshooting

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

DSB-100 Portable Premium Bluetooth Speaker Owner s Manual

How To Use A Brother Ql700

BUSINESS COMMUNICATIONS DIVISION. IP4100 SIP DECT User Guide

MZ Series Overview. Introduction. (MZ 220 Illustrated)

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

FLOOR WASHING ROBOT. 300 Series

AU680 Every Other Week or Every 3,000 Samples (ISE) Maintenance. AU680 Weekly (Analyzer and ISE) Maintenance

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Operator s Manual. spectrum 35700BAX & 35700ABB. Gen 2 Operating System Pump Operating Software v6.05 For Use with MDL Editor v6.2.

510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure

OC-3 SERIES OF PRINTERS

PA500II Enterprise Mobile Computer

PAR Tablet 10 Quick Start Guide

TUTA B12. User Manual GSM REMOTE CAMERA. Manual version 3.0

Get started. Issue 1

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

Before you start. This Guide contains instructions in how to set up and use the BeoCom 6000 handset with a BeoLine base.

Nucleus CP810 Sound Processor and Nucleus CR110 Remote Assistant Troubleshooting Guide

ON TRACK Reprocessing Inservice / Competency for GI Endoscopes (EVIS, EXERA, EXERA II)

OPERATIONAL & MAINTENANCE MANUAL SEM Model 244/4 REV: 1

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

User Manual I1010Q16DCZ

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

GE Simon XT Quick User Guide

SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0

Medina, New York v f

irobot Scooba Owner s Manual

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

Portable Air Conditioner

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Multi-Therapy Smart Infusion for Home Care

Patient Manual. Oxygen Concentrator

Ericsson W25. Mobile Networks. Quick Installation Guide

Personal Assistance System Owner's Guide

COASTAL AMUSEMENTS INC.

Electronic Time Recorder

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

EKOS Cart. Instructions for Use

THE NEW GENERATION IN TECHNOLOGY. NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking. Operating Instructions

AUTODIALLER / QUICKDIALLER - SA132

Using a Graseby MS26 Syringe Driver for Continuous Subcutaneous Infusions (CSCI) Protocol

Operating Instructions - Recovery, Backup and Troubleshooting Guide

BARD MEDICAL DIVISION UROLOGICAL DRAINAGE. Foley Catheter Care & Maintenance. Patient Education Guide

Installation and Operation Back-UPS 1250, 1300, 1500

MCR1900 Media Converter 19-Slot Chassis

HP 22-in-1 Media Card Reader

Home Theater PC Chassis

OM2260VW2 USER MANUAL VERIZON WIRELESS HOME PHONE CONNECT

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Your Phone This section introduces you to the hardware of the device.

NIKI V4 Infusion Pump

Please read and keep these instructions. Run water through your machine before first use

User Manual. Therapy System. Electronic Printed Document. Not For Commercial Print. User Responsible For Current Revision Level Rev D

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

ExStik TM ph Waterproof Meters

INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM

Notice. Reverse engineering and disassembly are prohibited.

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Your Simple Guide to Battery. Replacement. Customer Care:

Manual for Fire Suppression & Methane Detection System

BW-500 BED WEIGHER USER MANUAL

FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL

Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)

Transcription:

SENTINEL ENTERAL FEEDING PUMP USER TRAINING PACKET

TABLE OF CONTENTS Section Page I. Sentinel Enteral Feeding Pump Inservice Video DVD (inside front cover of binder) II. Sentinel Enteral Feeding Pump and Sets Safety Features & Benefits. 4 III. Pump Components (Front & back photos with parts labeled).. 5 IV. Set Installation. 6 V. Pump Programming Step by Step Programming Guide... Programming Quick Reference (back pocket of binder) 7-9 VI. Troubleshooting Guide. 0 VII. Proficiency Test.. VIII. Frequently Asked Questions... IX. Key Contacts (for technical questions, customer service, etc.)... X. Support Materials ALCOR /AMSure Enteral Feeding Systems sell sheet Sentinel Enteral Feeding Pump Operating Manual ALCOR AMSure Enteral sets IFUs Set Spike/Container Compatibility Guide Enteral Set Cross Reference

SECTION I: SENTINEL ENTERAL FEEDING PUMP INSERVICE VIDEO (DVD)

SECTION II: SENTINEL PUMP AND SETS KEY FEATURES & BENEFITS Pump Large, dual display shows infusion rate and volume delivered simultaneously Patented drop detection technology minimizes nuisance alarms Advanced memory keeps settings until manually erased Clear audible & visual alarms Easy to use. Press ON to turn on pump. UP or DOWN to set infusion rate. Press RUN to begin feeding Sets Purple anti-iv spikes compatible with Abbott & Nestle safety ports* Purple Secure Lock distal tip minimizes inadvertent disconnections Smooth ridged distal tip reduces feeding tube damage IV warning tag Latex-free * See Set Spike/Container Compatibility Guide (at back of manual) ALCOR AMSure Enteral Feeding Pump Sets Enteral pump spike set compatible with Nestle 00mL enteral feeding bag with E-004 SpikeRight E-00 PLUS and Abbott attached pump set Safety Screw 500mL enteral feeding bag with 00mL enteral feeding bag with E-0500M E-00M attached pump set and magnet attached pump set and magnet Also available: Full line of irrigation syringes, kits & trays flat top piston, thumb ring piston and bulb syringes. 4

SECTION III: PUMP COMPONENTS Front INFUSION RATE DISPLAY VOLUME INFUSED DISPLAY DROP SENSOR TUBING HOOK SET LOCATOR SHELF KEYPAD ROTOR VISUAL INDICATORS Back CAP HOLDER 5

SECTION IV: SET INSTALLATION. Close roller clamp and insert and seat drip chamber.. Open roller clamp and expel air from tubing.. Close roller clamp. 4. Pull tubing under rotor. 7. Seat tube adapter into locator shelf. 5. Wrap tubing behind tubing retainer. 6. Open roller clamp. 6

SENTINEL ENTERAL FEEDING PUMP Programming Guide Refer to Operating Manual for detailed instructions See also Programming Directions on the pump 7

Set Infusion Rate (Left Display) Set Dose Limit (Right Display). Press ON. Alarm will sound. Right display will. Press UP or DOWN until desired infusion rate is displayed on left.. Press RUN/STOP to begin feeding. 4. Press RUN/STOP.. Press SET. dos Set will display on left.. Press UP or DOWN until desired dose limit is displayed on right. 4. Wait 5 seconds - Press RUN/STOP to resume feeding. Adjust Infusion Rate (Left Display) Adjust Dose Limit (Right Display). Press RUN/STOP.. Press UP or DOWN until desired infusion rate is displayed on left.. Press RUN/STOP to resume feeding. 4. Press RUN/STOP.. Press SET. dos Set will display on left.. Press UP or DOWN until desired dose limit is displayed on right. 4. Wait 5 seconds - Press RUN/STOP to resume feeding. Check Dose Limit (Right Display) Check Accumulated Volume Delivered (Right Display). Press RUN/STOP.. Press SET. Dose Limit will display on right.. Wait 5 seconds - Press RUN/STOP to resume feeding. 8. Press RUN/STOP.. Press DOSE CHECK. tot will display on left. Accumulated volume delivered will display on right.. Wait 5 seconds - Press RUN/STOP to resume feeding.

Reset Volume Delivered (current dose) to Zero Reset Volume Delivered (current dose) & Dose Limit to Zero & Infusion Rate to 5. Press RUN/STOP.. Press CLEAR. Hold for beeps. Right display will reset to zero.. Press RUN/STOP to resume feeding.. Press RUN/STOP.. Press CLEAR. Hold for 7 beeps. Left display will reset to 5, right display will reset to zero.. Press RUN/STOP to resume feeding. Reset Accumulated Volume Delivered to Zero 4. Press RUN/STOP.. Press DOSE CHECK. tot will display on left. Accumulated volume delivered will display on right.. Press CLEAR. Hold for beeps. Right display will reset to zero. 4. Wait 5 seconds - Press RUN/STOP to resume feeding. Change Alarm Volume Change Display Brightness SIMULTANEOUSLY PRESS AND Hold for 5 seconds. Press RUN/STOP. Lock/Unlock Keypad SIMULTANEOUSLY PRESS AND. Press RUN/STOP. While pump is running SIMULTANEOUSLY PRESS AND Hold for 5 seconds 9

ALARMS & INDICATORS OCC/EMP Pathway occluded Container empty Drip chamber improperly installed, or Pump inactive for over ½ minutes DOSE COMP Dose limit has been reached. (4 beeps, flashing indicator, ½ minute repeats) FLO FAST Tubing not on rotor, or Drop sensor blocked over 6 seconds. (Loud tone beep) LOW BAT Low battery. Plug into AC outlet To Reset Alarms. Press RUN/STOP. Correct alarm condition. Press RUN/STOP to resume feeding 0

SECTION VI: TROUBLESHOOTING GUIDE SITUATION POSSIBLE CAUSE SOLUTIONS Battery light flashes. After 5 minutes, pump stops, displays flash, & alarm beeps. Battery charge level is low. Plug cord into AC outlet for 0 hours for full recharge. OCC/EMP alarm activates. Pump stops, alarm sounds, displays Alarm sounds when attempting rate change. Pump does not stop.. Container is empty.. Occlusion is restricting flow. Drip chamber not properly placed in locator shelf; drops not being sensed 4. Pump is on standby (STOP) more than ½ minutes. UP, DOWN, or CLEAR will only work when pump has been stopped.. Replace or refill.. Find point of occlusion: kinked tubing or closed roller clamp in pump set; feeding tube; container.. Place properly. 4. Press RUN/STOP or OFF Press RUN/STOP once. Change rate. Press RUN/STOP again to restart. DOSE COMP alarm sounds. Displays FLO FASt alarm sounds. Displays Pump has delivered set dose.. Pump set is dislodged. Tubing is off the rotor.. Drop sensor blocked due to formula on drip chamber walls.. Drop sensor blocked due to overfilled drip chamber. Increase dose limit. Press RUN/STOP. Pump will run until dose is complete again. If feeding has been completed, press RUN/STOP then OFF. If feeding incomplete, set the dose limit to zero.. Stop excess flow. Check set placement on rotor. Restart pump.. Clear drip chamber or replace pump set.. Invert and reinstall drip chamber

SECTION VII: PROFICIENCY TEST SENTINEL ENTERAL FEEDING PUMP PROFICIENCY TEST NAME DATE FACILITY CITY, STATE PART A: DEMONSTRATE THESE PUMP/SET SETUP STEPS Task Satisfactory Completion (initial). Load the set into the pump and prime the line. Set the infusion rate at 50 ml/hour and the dose at 450 ml. View total accumulated volume then reset it to 0 4. Change infusion rate to 75 ml/hour and the dose to 750 ml 5. Clear the volume delivered and dose limit, and reset infusion rate to 5 PART B: ANSWER THESE QUESTIONS. Why do the ALCOR AMSure Enteral Feeding Sets have a purple spike and distal tip?. Can a non- ALCOR AMSure set be used on the pump? [Circle either YES or NO]. Name things that the OCC/EMP alarm could indicate. 4. What is the alarm that signals the dose limit has been reached? 5. What steps can you take to resolve an excess flow ( FLO FASt alarm), if it occurs? Trainer/Facility Manager Signature of Successful Completion (Please print name)

SECTION VIII: FREQUENTLY ASKED QUESTIONS. How can I clean the Sentinel Enteral Feeding Pump? Clean the pump housing with warm soapy water and a damp cloth or sponge. Clean the drop sensor parts with soft cotton swabs dipped in isopropyl alcohol. Do not use cleaners that will degrade polycarbonate.. What are the minimum and maximum flow rates? 5 95 ml/hr in ml increments.. What is the dose accuracy? +/- 0% of selected flow rate with ALCOR AMSure sets. 4. What are the dimensions of the pump? H: 9 cm (7.48 inches) W: cm (9.06 inches) D: cm (5. inches) 5. What is the weight of the pump?.45 kg (5.4 lbs) 6. Can I use a non- ALCOR AMSure set on the pump? No. To assure patient safety and accuracy of the pump delivery only a validated ALCOR AMSure set can be used on the Sentinel Enteral Feeding pump. 7. Does the pump retain its memory in a power failure or when the unit is turned off? Yes 8. Can I infuse water with the Sentinel pump? Yes. The Sentinel Enteral Feeding Pump is designed to work with all liquid nutrition formulas and water. It has a patented system to recognize fluid drops and to minimize false alarms caused by soiled drip chambers. 9. What is the battery life of the pump? 6 hours minimum at 5 ml/hr 0. Is there a pause button on the pump? To pause the pump, simply press RUN/STOP button and the pump will notify you every ½ minutes that it is not running.. Why do the ALCOR AMSure Enteral Feeding Sets have purple colored connectors? This is the universal color for enteral feeding set connectors and is designed to help prevent the set from inadvertently being connected to an IV container or catheter.. Why do the ALCOR AMSure Enteral Feeding Sets have a locking slot on the distal tip? The tethered G-tube cap can be placed in the designated locking slot on the distal dip to help prevent unwanted disconnects.. When a programmed dose limit is reached, how many beeps does the pump alarm signal? The alarm will signal 4 beeps and the indicator will flash DOSE COMP. This repeats every ½ minutes

SECTION IX: KEY CONTACTS Orders/Customer Service.Amsino (800) 6-6746 Sets Technical Information..Amsino (800) 6-6746 Pump Technical Information. ALCOR Scientific (800) 495-570 Warranty/Repair. ALCOR Scientific (800) 495-570 4

Sentinel Enteral Feeding Pump Quick Reference Refer to Operating Manual for detailed instructions See also Programming Directions on the pump Set Infusion Rate (Left Display) Set Dose Limit (Right Display) 4 Adjust Infusion Rate (Left Display) Adjust Dose Limit (Right Display) 4 Check Dose Limit (Right Display) Check Accumulated Volume Delivered (Right Display) 5

Sentinel Enteral Feeding Pump Quick Reference Refer to Operating Manual for detailed instructions See also Programming Directions on the pump Reset Volume Delivered (current dose) to Zero Reset Volume Delivered (current dose) & Dose Limit to Zero & Infusion Rate to 5 Hold for beeps Hold for 7 beeps Reset Accumulated Volume Delivered to Zero Hold for beeps 4 Reset Alarms Alarms & Indicators OCC/EMP Pathway occluded Container empty Drip chamber improperly installed, or Pump inactive for over ½ minutes DOSE COMP Dose limit has been reached. (4 beeps, flashing indicator, ½ minute repeats) FLO FAST Tubing not on rotor, or Drop sensor blocked over 6 seconds. (Loud tone beep) LOW BAT Low battery. Plug into AC outlet Correct alarm condition 6