Technical Support Bulletin Nr. 20 Special AC Functions



Similar documents
HVAC Processes. Lecture 7

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

Failure code manual. content

Single Zone LCD Thermostat Operating Instructions

REMOTE CONTROL MANUAL

Inwall Room Temperature Unit

INSTALLATION OPERATING & MAINTENANCE MANUAL

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty


Heating and Cooling Basics Thermostat Control

Air Conditioning System

Mixing Valves. ARGUS Application Note: Mixing Valves

CGC s Hybrid System Loop Control

Variable Air Volume - VAV

4 Alarm and info. Alarm. Yes Warning. No Information No Reset alarms > No Current list > Alarm log list > Delete alarm log > No

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

INSTALLATION AND OPERATION MANUAL

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

INSTALLATION MANUAL. Address card EKAC10B

SMM. Installation Operation Maintenance

User's Guide. CTS6000 WebControl

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Lesson 36 Selection Of Air Conditioning Systems

DUCT TYPE AIR CONDITIONER

Impact of Control System Technologies on Industrial Energy Savings

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Glossary of Heating, Ventilation and Air Conditioning Terms

Basic Technology Series

COMPTROL 5000 INDEX 52. Issue 5.99 AIR CONDITIONING MICROPROCESSOR OPERATING INSTRUCTIONS. STULZ GmbH, Hamburg

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

How To Control Humidity With A Humidifier

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

HEATING, VENTILATION & AIR CONDITIONING

AIRAH Presentation April 30 th 2014

RZAHUC program version 1.1 Regulation for Reznor Air Handling Units

AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE HOMEOWNERS GUIDE

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

W3000 TECHNICAL MANUAL C GB

Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E.

How Ground/Water Source Heat Pumps Work

Elements of Energy Efficiency in Data Centre Cooling Architecture

- White Paper - Data Centre Cooling. Best Practice

State of the Art Energy Efficient Data Centre Air Conditioning

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M ES/M , ES/M

30RB/30RQ. Operation and maintenance instructions

Direct Fresh Air Free Cooling of Data Centres

User manual. Application program for pco 1, pco 2, pco 3. Standard Chiller Modular HP 1/4 Generic /Bitzer screw compressor and CAREL valve

SERVICE MANUAL REFRIGERATION

Commercial Refrigeration Temperature and Defrost Controls

C-Bus Application Messages & Behaviour Chapter 25 Air Conditioning

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

Automation System TROVIS 5100 Ventilation Controller TROVIS 5177

Section 6. Introduction to Automatic A/C. Automatic Temperature Control

Chilled Water HVAC Systems

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

CHAPTER CONTENT PAGE. Hybrid: The perfect solution for all systems. Explanation of the - Heat Exchanger 4. Finishes 12

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

We have been working in an ideal climate for thirty years.

How To Get A Passive House

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Using Time-of-Day Scheduling To Save Energy

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ABB i-bus KNX Fan Coil Controller FC/S 1.1

5.6 Technical Specification: Premium Efficiency Electric Air Conditioning Equipment

Fundamentals of HVAC Control Systems

Rev. No. 0 January 5, 2009

HVAC Systems: Overview

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

How To Understand Evaporator

CONTROL STRATEGIES FOR HVAC SYSTEMS

Dyeing Programmer DP - 01

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

GaiaMoto Programmable Differential Temperature Controller

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

Condensing Boiler Efficiency

MODBUS for ECH 200 Serial Communication Protocol <IMG INFO>

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Thermostat with display

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

ECOCIAT. Domestic hot water heat recovery unit

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

Computer Controlled Capacity Control Methods in Refrigeration, with SCADA and PID Control THARA2C/1

Absolute and relative humidity Precise and comfort air-conditioning

CoolTeg Plus Chilled Water (CW) version: AC-TCW

HEAT HEAT COOL HEAT PUMP COOL

Transcription:

Technical Support Bulletin Nr. 20 Special AC Functions Summary! Introduction! Hot Start Control! Adaptive Control! Defrost Start Temperature Compensation Control! Anti-Sticking Control! Water Free Cooling Control! Economiser Control! Antifrost Control with Water and Heat Pumps! Power Limitation Control! Sensor Upstream/Downstream from Valve Control Introduction This bulletin describes the special control functions incorporated in certain air conditioning controllers to supplement conventional control functions. The bulletin describes the potential applications of each function and lists the controllers it is available in. Eliwell Controls s.r.l. Via dell Industria, 15 Zona Industriale Paludi 32010 Pieve d Alpago (BL) ITALY Telephone +39 0437 986 111 Facsimile +39 0437 989 066 Technical helpline +39 0437 986 300 E-mail techsuppeliwell@invensyscontrols.com www.eliwell.it Technical Support Bulletin Eliwell Controls s.r.l. 2007 All rights reserved.

Hot Start Control Description Hot Start Control allows the internal fan to start only when the heat exchanger is hot enough, thus avoiding unpleasant draughts of cold air. Controllers providing this function ERT200, ECH200, Energy ST500 Enabling and activation of Hot Start Control Hot Start Control is enabled and activated if the following conditions are satisfied. The internal fan is enabled. The temperature sensor is configured as NTC water/air output sensor. The controller is in heating mode. Hot Start setpoint and hysteresis are controlled by the following parameters: HOT START setpoint HOT START hysteresis Functioning The following diagram illustrates the functioning of Hot Start Control. Hot Start Control Fan speed SET HOT START Setting OFF HYSTERISIS Temperature (ST2) 2/20 Nr. 20 Special AC Functions Technical Support Bulletin

Adaptive Control Description Many chillers incorporate water accumulators. These provide the thermal inertia required to avoid frequent compressor starts and stops during periods in which there is little call for cooling from the conditioned rooms. For example, if a chiller is dimensioned to serve 10 fan coils but only one is switched on in cooling mode, the compressor would only remain on for a very brief time. Because safety times have to be respected, however, water temperature would soon rise well above the switching point determined by hysteresis. The presence of water accumulators increases thermal capacity and provides the inertia needed to extend compressor functioning times. Water accumulators nevertheless represent a significant cost and also increase the size of the equipment. Adaptive Control modifies setpoint and hysteresis values in order to extend compressor run time and limit the need for water accumulators. Compressor ON OFF Compressor ON time Standard time Time Controllers providing this function ECH200BD, ECH200BP, ECH400SRD, Energy ST500 Enabling and activation of Adaptive Control Adaptive Control is enabled and activated by setting the relevant parameter accordingly. Functioning Adaptive Control analyses the compressor s effective run time and compares it with the minimum run time setting. If effective run time is below minimum run time in cooling mode, every time the compressor switches off at the setpoint or at hysteresis (or both), an offset value is subtracted or added accordingly. In heating mode this offset increments both hysteresis and setpoint. The offset value is determined by summing a fixed value and a value proportional to the difference between minimum run time and effective run time. The following diagram illustrates an example, valid for the ECH200 controller, of how setpoint and hysteresis are changed in cooling mode with an effective compressor run time shorter than minimum run time. The function is disabled (i.e. offsets are disabled) if water output temperature (AI2) reaches the maximum limit in heat mode (Pa C09) or minimum limit in cooling mode (Pa C10). If this happens the compressors are switched off just as if AI1 had reached setpoint. 3/20 Nr. 20 Special AC Functions Technical Support Bulletin

If compressor run time is greater than parameter P C12, the setpoint and hysteresis are decremented by the same fixed value Pa C11. Functioning is cyclical, and is repeated after the compressor has been running for a further Pa C12 seconds. The cycle is interrupted when the setpoint and hysteresis both return to their initial values. Compressor Setpoint offset on basis of minimum run time ON OFF Minimum hysteresis AI1 Maximum hysteresis The following is a description of the parameters governing Adaptive Control. Function enabling Setpoint AI2 for disabling the function in cooling mode (expressed in degrees) Setpoint AI2 for disabling the function in heating mode (expressed in degrees) Setpoint differential: this value is subtracted from the cooling setpoint and added to the heating setpoint; it is added to both the cooling and heating hysteresis. Offset reset time: whenever compressor run time reaches this value, Pa C11 is added to the cooling setpoint and subtracted from the heating setpoint and hysteresis. The count restarts from zero with every reset. Proportional constant: this value is used to multiply the difference between minimum run time and effective run time. 4/20 Nr. 20 Special AC Functions Technical Support Bulletin

Defrost Start Temperature Compensation Control Description In particularly dry and cold climates, defrost start temperature may not coincide with the actual temperature at which the outdoor unit can freeze. Defrost Start Temperature Compensation Control provides linear compensation for defrost start temperature/pressure by adding negative or positive values on the basis of outdoor temperature. Controllers providing this function ECH200BD, ECH200BDK, ECH200BDT, ECH200BP, ECH400S, ECH400SR, Energy ST500 Enabling and activation of Defrost Start Temperature Compensation Control Example for ECH: Defrost Start Temperature Compensation Control is enabled and activated by setting Pa d12=1 and by configuring sensor AI4 as outdoor sensor (Pa H08=3). Functioning The following is a description of the parameters governing Defrost Start Temperature Compensation Control. Defrost temperature/pressure compensation offset. Defrost temperature/pressure compensation setpoint. Defrost temperature/pressure compensation differential. The following two diagrams illustrate how the defrost setpoint is offset on the basis of outdoor temperature when this is above and below 0. Pa d11 > 0 Pa d12 Pa d12 Temp Pa d11 < 0 Pa d13 < 0 Pa d13 > 0 Temp Pa d13 < 0 Pa d13 > 0 5/20 Nr. 20 Special AC Functions Technical Support Bulletin

Anti-Sticking Control (periodical operation of water pump) Description Anti-Sticking Control allows you to force the water pump on if it has been idle for a set time (determined by a parameter setting) and keep it running for another set time (also determined by a parameter setting). Controllers providing this function ECH200BDT, Energy ST500 Enabling and activation of Anti-Sticking Control Example for ECH 200: To enable Anti-Sticking control simply set parameters P06 (pump idle time expressed in hours) and P07 (pump Anti-sticking run time). The function is disabled by setting both these parameters to 0. Functioning The following diagram illustrates the functioning of Anti-Sticking Control. Pump Pa P06 Pa P06 ON OFF Time Pa P07 Pa P07 6/20 Nr. 20 Special AC Functions Technical Support Bulletin

Water Free Cooling Control Description Water Free Cooling makes use, whenever possible, of outdoor air to lower the temperature of the conditioned circuit. Cooling action is obtained by channelling water returning from the circuit through a finned cooling unit, (the free cooling unit) before it enters the evaporator heat exchanger. When free cooling is active, the compressors are not disabled but continue to follow the same rules and same on/off setpoint. While free cooling remains active, water temperature is controlled not only by the compressors, if needed, but also by modulating the fans controlling air flow through the free cooling unit. These may be the same fans used to control condensation, (internal free cooling Pa L01=3), or fans dedicated to this purpose, (external free cooling Pa L01=2). The following is a brief description of the positioning of the free cooling unit for internal and external free cooling. INTERNAL Free Cooling EXTERNAL Free Cooling The free cooling unit is installed on top of the condensation units, and the fans that provide the air flow for cooling the water are the same fans that regulate compressor condensation pressure. The free cooling unit is installed separately, away from the condensation units, and incorporates its own independent fan. The following diagrams illustrate two systems, with internal and external free cooling unit. Example of system with internal unit: Outdoor air CONDENSER UNIT FREE COOLING UNIT CONDENSER UNIT EVAPORATOR 1 Free cooling valve To circuit EVAPORATOR 2 7/20 Nr. 20 Special AC Functions Technical Support Bulletin

Example of system with external unit: Outdoor air CONDENSER UNIT CONDENSER UNIT Free cooling valve EVAPORATOR 1 To circuit EVAPORATOR 2 FREE COOLING UNIT EXTERNAL free cooling units are located separately from the condensing units, and have their own independent fans. Controllers providing this function ECH400F, XT Enabling and activation of Free Cooling control Example for ECH: Free Cooling Control is activated by parameter L01 (Pa L01=1), and starts and stops only under the following conditions: Free cooling starts if: Outdoor temperature (AI4) is below the value determined by: AI4 Current setpoint + L02 (Pa L02 Free Cooling inlet differential) The digital input that enables free cooling is NOT ACTIVE. The lower of the evaporator output water temperatures is above the anti-frost prealarm threshold value (Pa L04 anti-frost pre-threshold) plus 1 C. Free cooling stops when: Outdoor temperature (AI4) is above the value determined by: AI4 > (Current setpoint +L02) + L03 (Pa L03 Free Cooling output hysteresis) The digital input that enables free cooling is ACTIVE. The lower of the evaporator output water temperatures is below the anti-frost prealarm threshold value (L04). (Valid only if compressors are already stopped). 8/20 Nr. 20 Special AC Functions Technical Support Bulletin

SET FC FC active atti vo L02 L03 FC not active FC non atti vo AI4 Functioning Free cooling works by deviating the flow of water returning from the user circuit through the free cooling unit before it enters the evaporator heat exchanger. Free cooling is only activated if outdoor air temperature is below a certain value (dynamically linked to the system s cooling setpoint). This means that water leaving the free cooling unit will already have been cooled. The extent of this cooling will depend on outdoor temperature, and on the air flow rate provided by the fans. Free cooled water then enters the evaporator heat exchanger, where its temperature is measured by sensor AI1. The compressors are switched on or off on the basis of this temperature, just as in normal operation without free cooling. Water temperature during free cooling is regulated by varying the rate of air flow. Air flow is controlled on the basis of evaporator inlet temperature. 9/20 Nr. 20 Special AC Functions Technical Support Bulletin

G INFO> 42 27 1 2 65-13 -1 32,2 FREE COOLING FANS The following graph shows the curve for the proportional fan control outputs. (The graph shows the behaviour of the temperature controller when free cooling is active). For simplicity s sake we assume in this example that the unit has just two steps). Velocità % Speed % Cooling setpoint Max 0 Pa F11 Pa L05 Water Temperatura evaporator temperature acqua evaporatore Pa L06 Pa L07 The fans are stopped when evaporator inlet water temperature (AI1) is below the value determined by: Current setpoint + L07 (free cooling cut-off temperature differential). They start up again when evaporator inlet water temperature rises to the free cooling minimum value (AI1> Cooling setpoint + L07 + F11). 10/20 Nr. 20 Special AC Functions Technical Support Bulletin

Economiser Control Description Example for ECH: Economiser Control uses the controller s 0-10V dc analog output or relay output (Pa H35-H40 or N06-N010 = 15) to control the gate valve. Economiser Control permits room temperature to be controlled by free cooling or free heating using outdoor air entering the rooms through the gate valve. Gate valve control is proportional. Temperature and enthalpia based free cooling/heating functions are described below. Controllers providing this function ERT400, ERT200 (the latter model only provides temperature based free cooling/heating) Temperature based free cooling and free heating Enabling and activation of temperature Free Cooling/Heating Control The function is enabled if: Free-cooling is enabled (Pa L01=1) Sensor AI1 is configured as analog control input (Pa H11) Sensor AI4 is configured as analog input for outdoor temperature (Pa H14 = 1) Outdoor temperature is above Pa L08 + Pa L09 Functioning If outdoor temperature is near the free cooling/heating setpoint, and outdoor temperature and the free cooling/heating setpoint are both higher or both lower than the system temperature setpoint, the gate valve must be completely open. This will help indoor temperature reach the free cooling/heating setpoint more rapidly. If on the other hand outdoor temperature is far off the free cooling/heating setpoint, the gate valve is modulated in order to bring indoor temperature closer to the system temperature setpoint. If outdoor temperature (AI4) falls below the value set in Pa L08, Economiser Control is deactivated and the gate valve is set to minimum aperture Pa L07. When outdoor temperature rises above Pa L08 + Pa L09, the function is re-enabled and the controller again assumes control over the gate valve. Care must be taken to distinguish between free cooling mode and free heating mode. Let us examine two possible scenarios. Cooling mode The following cases illustrate free cooling mode. Outdoor temperature is below the cooling setpoint. If the free cooling setpoint coincides with the cooling setpoint, as soon as the compressors are switched off the gate valve closes, making it impossible to save energy through the use of cooler outdoor air. The free cooling setpoint is calculated by subtracting the value set in parameter Pa L02 (cooling mode free cooling offset) from the cooling setpoint. The gate valve is set at its minimum aperture at the free cooling set point. If indoor temperature falls below the free cooling setpoint and below outdoor temperature, the gate valve is 11/20 Nr. 20 Special AC Functions Technical Support Bulletin

opened fully to warm the indoor rooms and bring indoor temperature up to the system setpoint. Damper Freecooling Setpoint = Cooling Setpoint - L02 Outdoor temperature 100% L07 % L06 L03 Inside temperature Outdoor temperature is above the cooling setpoint. In this case outdoor temperature cannot be used to cool the indoor rooms unless indoor temperature rises above outdoor temperature (in which case the gate valve is fully opened). Outdoor air can instead be used to warm the rooms if indoor temperature is below the setpoint. In this case the free heating setpoint coincides with the cooling setpoint. Damper Freeheating Setpoint = Cooling Setpoint Outdoor temperature 100% L07 % L03 L06 Inside temperature 12/20 Nr. 20 Special AC Functions Technical Support Bulletin

Heating mode The same considerations apply in heating mode as in cooling mode, with the difference that the logic for calculating the free heating setpoint is reversed. Outdoor temperature is below the heating setpoint. In this case outdoor temperature cannot be used to heat the rooms unless indoor temperature drops below outdoor temperature (in which case the gate valve is fully opened). Outdoor air can be used instead to cool the rooms if indoor temperature is above the setpoint. In this case the free cooling setpoint coincides with the heating setpoint. Damper Freecooling Setpoint = Heating Setpoint Outdoor temperature 100% L07 % L06 L05 Inside temperature Outdoor temperature is above the heating setpoint. If the free heating setpoint coincides with the heating setpoint, as soon as the compressors are switched off the gate valve closes, making it impossible to save energy through the use of warmer outdoor air. The free heating setpoint is calculated by adding the value set in parameter Pa F28 (heating mode free cooling offset) to the cooling setpoint. The gate valve is set to its minimum aperture at the free heating setpoint. If indoor temperature rises above the free heating setpoint and above outdoor temperature, the gate valve is opened fully to cool the indoor rooms and bring indoor temperature to the system temperature setpoint. 13/20 Nr. 20 Special AC Functions Technical Support Bulletin

Damper Freeheating Setpoint = Heating Setpoint + L04 Outdoor temperature 100% L07 % L05 L06 Inside temperature Enthalpia based free cooling and free heating Enabling and activation of enthalpia based Free Cooling/Heating Control This function is enabled by setting the following parameters: Pa L01: free cooling enabling Set the outdoor air temperature sensor Pa H14=1 Sensor AI4 present Set the outdoor humidity sensor Pa H13 = 3, sensor AI3 configured as 4-20mA outdoor humidity input If AI3 is not configured as humidity input you can set parameter N12 instead Pa N12 = 1, sensor AI8 configured as 4-20mA outdoor humidity input Set the indoor humidity sensor Pa H16 = 3, sensor AI6 configured as 4-20mA recirculated air humidity input If AI6 is not configured as humidity input you can set parameter N11 instead. Pa N11 = 1, sensor AI7 configured as 4-20mA recirculated air humidity input Dummy humidity sensor If no sensor is configured as outdoor humidity sensor, and parameter L15 is set to a value other than 0, this value will be used as the outdoor humidity value for the purposes of enthalpia calculations. Automatic free cooling recognition If sensor AI4 is present and free cooling is enabled, the free cooling function provides temperature based free cooling. If the 2 humidity sensors are also present, the function provides enthalpia based free cooling instead. If a dummy humidity setting other than 0 is made (in Pa L15), an outdoor humidity sensor is assumed to be present even if no physical sensor is installed. Functioning 14/20 Nr. 20 Special AC Functions Technical Support Bulletin

Enthalpia is a thermodynamic quantity that takes account of humidity as well as air temperature. In simple terms it can be considered as the heat to be subtracted or added to air in order to pass from one set of humidity and temperature values to another set of humidity and temperature values. Let us examine the following scenarios for the enthalpia setpoint. Outdoor enthalpia is below the enthalpia setpoint. The enthalpia setpoint is set in parameter L10 (cooling mode enthalpia). The gate valve is set to its minimum aperture at the setpoint. If indoor enthalpia falls below the enthalpia setpoint and below the outdoor enthalpia value, the gate valve is opened fully to bring indoor enthalpia to the setpoint. Damper Enthalpy Hentalpy Setpoint = L10 or L12 100% Outdoor enthalpy hentalpy L07 % L14 L11 or L13 Inside Enthalpy Hentalpy Outdoor enthalpia is above the enthalpia setpoint. In this case outdoor enthalpia cannot be used to reduce indoor enthalpia unless indoor enthalpia rises above outdoor enthalpia (in which case the gate valve is fully opened). Outdoor air can be used instead to increase indoor enthalpia if it is below the setpoint. 15/20 Nr. 20 Special AC Functions Technical Support Bulletin

Damper Enthalpy Hentalpy Setpoint = L10 or L12 Outdoor enthalpy hentalpy 100% L07 % L11 or L13 L14 Inside Hentalpy Enthalpy 16/20 Nr. 20 Special AC Functions Technical Support Bulletin

Antifrost Control with Water Pump and Heat Pump Description Antifrost Control with Water Pump and Heat Pump is a special function that uses the water pump and heat pump to provide anti-frost protection. Controllers providing this function ECH400 Special Enabling and activation of Antifrost Control with Water Pump and Heat Pump (Tsinghua function) Antifrost Control with Water Pump and Heat Pump is activated by setting parameter A23=1. Functioning Antifrost Control with Water Pump and Heat Pump works in two ways according to the temperature read by sensor ST1. The temperature read by ST1< Pa 20 (water pump on setpoint) The water pump is switched on (if off). This occurs in all functioning modes (cooling, heating, stand-by, off) and does not alter display status. The temperature read by ST1< Pa 21 (heating mode on setpoint) The heat pump is temporarily switched on (if off). This occurs in all functioning modes (cooling, stand-by, off) and alters the display status (heating mode is displayed). When this function is active it is not possible to change functioning mode either from the keypad or by means of a digital input. The controller returns to normal functioning if temperature ST1> Pa A22 (function off setpoint). 17/20 Nr. 20 Special AC Functions Technical Support Bulletin

Anti-Sticking Control (periodical switching on of water pump) Description In the controllers in which it is implemented, Anti-Sticking Control reduces the power (i.e. the number of active steps), either by means of a digital input, or at a set threshold (e.g. a pressure value). This avoids the inconvenience of system safety devices tripping. 18/20 Nr. 20 Special AC Functions Technical Support Bulletin

Sensor Upstream/Downstream from Valve Control Description Sensor Upstream/Downstream from Valve Control is implemented on two tube fan coil controllers with a valve thermostat, and allows the valves and fans to be controlled on the basis of water sensor position. Controllers providing this function FAN COIL BASICOM, FAN COIL PLUS Functioning Sensor Upstream/Downstream from Valve Control works differently depending on the position of the water temperature sensor. We can distinguish two situations. Water sensor fitted downstream from valve (Pa P50=0) The Hot Start and Too Cool functions stop the fan operating but not the valve. Water sensor fitted upstream from valve (Pa P50=1) The Hot Start and Too Cool functions stop the valve operating but not the fan. N.B. On 2 and 4 tube systems with a fan thermostat, the meaning of parameter P50 is irrelevant (see the controller s user manual for details of functioning). 19/20 Nr. 20 Special AC Functions Technical Support Bulletin

DISCLAIMER This document is the exclusive property of Eliwell and may not be reproduced or circulated unless expressly authorized by Eliwell. Although Eliwell has done everything possible to guarantee the accuracy of this document, it declines any responsibility for damage arising from its use. The same applies to any person or company involved in preparing and writing this document. Eliwell reserves the right to make changes or improvements at any time without notice. 20/20 Nr. 20 Special AC Functions Technical Support Bulletin