DISSOLVED OXYGEN SENSOR ML75M USER S GUIDE

Similar documents
Dissolved Oxygen Probe (Order Code DO-BTA or DO-DIN)

6 H2O + 6 CO 2 (g) + energy

DISSOLVED OXYGEN PROBE

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

CONDUCTIVITY SENSOR. Description D0382. Figure 1. The Conductivity Sensor

Milwaukee USER MANUAL

User Guide Dissolved Oxygen Probes

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

Chloride and Salinity

OxyGuard. Dissolved Oxygen Probe

Dissolved Oxygen Sensors

MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

Trace Dissolved Oxygen Sensor

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Operator Quick Guide EC SENSOR

Measurement by Ion Selective Electrodes

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Professional Plus. Calibration Tips

DISSOLVED OXYGEN METER Model : DO-5509

STANDARD OPERATING PROCEDURE Dissolved Oxygen Measurement, Meter Calibration and Maintenance

EXPERIMENT 7 Electrochemical Cells: A Discovery Exercise 1. Introduction. Discussion

Oxygen Measurement. with CONTENTS

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

Recovery of Elemental Copper from Copper (II) Nitrate

Reaction of Magnesium with Hydrochloric Acid (Gas Laws) Chemicals Needed:

Physical Properties of a Pure Substance, Water

Global Water Instrumentation, Inc.

Experiment 8 - Double Displacement Reactions

YSI Meter Protocol: Specific Conductivity, ph, & Dissolved Oxygen

Figure 1. A voltaic cell Cu,Cu 2+ Ag +, Ag. gas is, by convention, assigned a reduction potential of 0.00 V.

SenTix 950 SenTix 980

INSTRUCTION MANUAL. Handy Polaris

ExStik TM ph Waterproof Meters

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

ph Measurement and Control

Model MC-82 Dissolved Oxygen Temp. Meter Handbook Version : 1.0

Hands-On Labs SM-1 Lab Manual

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

Care and use guide. Contents. a handy solution made easy. page

Petri Dish Electrolysis Electrolysis Reactions

HOBO Dissolved Oxygen Logger (U26-001) Manual

AIRMoN, ph and Conductivity Field Measurement

A Potentiometric Analysis of Fluoride Ion in Toothpaste

Osmosis. Evaluation copy

NANYANG TECHNOLOGICAL UNIVERSITY. School of Civil and Environmental Engineering. CV2701: Laboratory 2A. Laboratory Manual. For

Operations Manual. YSI 550A Dissolved Oxygen Instrument

Tipping Bucket Rain Gauge Models 6011-A 6011-B

Ion Selective Electrodes

Care, Maintenance, and Storage of YSI 6-Series Probes and Sondes

Experiment 3 Limiting Reactants

Lesson 5: Water Conductivity and Total Dissolved Solids Water Quality Sampling

Dissolved Oxygen and Aquatic Primary Productivity1

Determining Equivalent Weight by Copper Electrolysis

Measuring Dissolved Oxygen Concentration in Aquaculture

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

EXPERIMENT # 3 ELECTROLYTES AND NON-ELECTROLYTES

ELECTROCHEMISTRY. Theory and Practice

CSUS Department of Chemistry Experiment 8 Chem.1A

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

USEPA Electrode Method Method 8156

PLANT TISSUE CULTURE

ph Measurements of Common Substances

Compact Water Quality Meter B-700 series

Lab 4: Osmosis and Diffusion

Experiment 9 Electrochemistry I Galvanic Cell

Experiment 6 Coffee-cup Calorimetry

Electrical Conductivity of Aqueous Solutions

Desalination of Sea Water E7-1

Discovering Electrochemical Cells

To see how this data can be used, follow the titration of hydrofluoric acid against sodium hydroxide below. HF (aq) + NaOH (aq) H2O (l) + NaF (aq)

The Determination of an Equilibrium Constant

Acid Base Titrations

Experiment 12- Classification of Matter Experiment

DO-6. Dissolved Oxygen Meter. Newport Electronics, Inc. Operator s Manual

Bluelab Soil ph Meter Instruction Manual

18 Conductometric Titration

Isolation of Caffeine from Tea

Relative Humidity Calibration Kit

Building Electrochemical Cells

CHEMICAL DETERMINATION OF EVERYDAY HOUSEHOLD CHEMICALS

Neutralizing an Acid and a Base

Lab 7 Soil ph and Salinity OBJECTIVE INTRODUCTION Soil ph active

Mixtures and Pure Substances

Color, True and Apparent

For additional information, please visit our website at

Photosynthesis and Respiration

REDOX AND REFERENCE ELECTRODE USER MANUAL

Lab #13: Qualitative Analysis of Cations and Anions

4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES

Pro1030 USER MANUAL. English

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

Enzyme Action: Testing Catalase Activity

Care and use guide. soil ph meter. Contents. page

Pressure Dew Point Probe / Application Information

THE ACTIVITY OF LACTASE

Photosynthesis and Respiration

Sugar or Salt? Ionic and Covalent Bonds

Transcription:

DISSOLVED OXYGEN SENSOR ML75M USER S GUIDE CENTRE FOR MICROCOMPUTER APPLICATIONS http://www.cma-science.nl

Short description The Dissolved Oxygen sensor ML75m measures the concentration of dissolved oxygen in water samples. The sensor consists of an oxygen electrode, which is a Clark type polarographic electrode that senses the oxygen concentration in water and aqueous solutions. A platinum cathode and a silver/silver chloride reference anode in KCl electrolyte are separated from the sample by a gas permeable plastic membrane. A fixed voltage is applied to the platinum electrode. As oxygen diffuses through the membrane to the cathode, it is reduced, ½ O 2 + H 2 O + 2e > 2 OH. The oxidation taking place at the reference electrode (anode) is Ag + Cl > AgCl + e Accordingly, a current will flow that is proportional to the rate of diffusion of oxygen, and in turn to the concentration of dissolved oxygen in the sample. The Dissolved Oxygen sensor is delivered with: replacement membrane cap, Sodium Sulfite Calibration Standard (2 M Na 2 SO 3 ) oxygen probe electrode filing solution, calibration bottle (empty, lid with hole), and filling pipette. The Dissolved Oxygen sensor is automatically temperature compensated. The temperature output of this sensor is used to automatically compensate for changes in permeability of the membrane with changing temperature. The Dissolved Oxygen sensor is an I2C digital sensor, which gives calibrated values of the measured quantity. This sensor can only be connected to special interfaces that support I2C digital sensors like the CMA MoLab interface. Sensor specifications The Dissolved Oxygen sensor ML75m is a digital sensor that converts the measured oxygen level to a digital value via 16 bit analog to digital conversion. The maximal sampling rate of the sensor is 1 Hz. 2 ML75m Dissolved Oxygen Sensor User s Guide

Collecting data This Dissolved Oxygen sensor works only with specific interfaces. The sensor will be automatically detected when connected to such an interface. For detailed information about measurements with sensors consult the User Manuals of the interface and the Coach 6 software. Preparing the Dissolved Oxygen sensor for use 1. Unscrew the membrane cap from the tip of the electrode. 2. Using a pipette, fill the membrane cap with 1 ml of oxygen probe electrolyte. Mind that there are no air bubbles in the electrolyte. 3. Carefully thread the membrane cap back onto the electrode being careful not to over tighten the cap. Rinse the electrode with distilled water. 4. Place the sensor into a beaker filled with about 100 ml of distilled water. Remove membrane cap Add electrode filling solution Place the membrane back. 5. Connect the sensor to the interface. 6. It is necessary to warm up the sensor for 10 minutes. To warm up the sensor, leave it in the water and collect the data for 10 minutes. The sensor must stay connected at all times to keep it warmed up. If disconnected for a few minutes, it will be necessary to warm up the sensor again. 7. The sensor is ready for measurement. ML75m Dissolved Oxygen Sensor User s Guide 3

Calibration The Dissolved Oxygen sensor is supplied with a factory calibration for dissolved oxygen level in mg/l. The Coach 6 program allows shifting the pre defined calibration if needed. The user calibration is stored in non volatile user sensor memory. The user calibration can be done for two calibration points (prior to calibration the sensor must be warmed up about 10 minutes). Zero Oxygen Calibration Point Use the provided Sodium Sulfite Calibration Solution. Sodium sulfite is a good reducing agent that readily removes dissolved oxygen from a solution. If the sulfite solution has been stored brim fully in its storage bottle, you can assume it to be oxygen free. Remove the sensor from the water and place the tip of the sensor into the Sodium Sulfite Calibration Solution. Important: Beware that no air bubbles will be trapped below the tip of the sensor or the sensor will sense an inaccurate dissolved oxygen level. If the voltage does not rapidly decrease, tap the side of the bottle with the sensor to dislodge the bubble. When the voltage stabilizes (~1 minute) enter 0 as the known value in mg/l. Saturated DO Calibration Point - Rinse the sensor with distilled water and gently blot dry. - Unscrew the lid of the calibration bottle provided with the sensor. - Slide the lid and the grommet about 1 cm onto the sensor body. - Add water to the bottle to a depth of about 1/2 cm and screw the bottle into the cap. Important: Do not touch the membrane or get it wet during this step. - Keep the sensor in this position for about a minute. When the reading stabilizes enter the correct saturated dissolved oxygen value (in mg/l) from Table 1 (for example, 8.66 ) using the current barometric pressure and air temperature values. If you do not have the current air pressure, use Table 2 to estimate the air pressure at your altitude. Collecting data You are now ready to collect dissolved oxygen concentration data. Place the tip of the sensor into the water being tested (submerge 4 6 cm). Do not completely submerge. The handle is not waterproof. Gently stir the probe in the water sample. Monitor the dissolved oxygen concentration. Note: It is important to keep stirring the probe in the water sample. There must always be water flowing past the probe tip when you are taking measurements. As the probe measures the concentration of dissolved oxygen, it removes oxygen from the 4 ML75m Dissolved Oxygen Sensor User s Guide

water at the junction of the probe membrane. If the probe is left still in calm water, reported dissolved oxygen readings will appear to be dropping. Table 1. Dissolved oxygen levels (in mg/l) in air saturated distilled water (at various temperature and pressure values). ML75m Dissolved Oxygen Sensor User s Guide 5

6 ML75m Dissolved Oxygen Sensor User s Guide Table 1. (continuation)

Elevation Barometric Pressure Table If you do not have a barometer available to read barometric pressure, you can estimate the barometric pressure reading at your elevation in feet (1 feet= 30.48 cm) from Table 2. Table 2. The values are calculated based on a barometric air pressure reading of 760 mm Hg at sea level. Suggested experiments Since dissolved oxygen is one of the primary indicators of the quality of an aquatic environment, you can use this sensor to perform a wide variety of tests or planned experiments to determine the changes in dissolved oxygen levels: Monitor dissolved oxygen in an aquarium containing different combinations of plant and animal species. Measure changes in dissolved oxygen concentration resulting from photosynthesis and respiration in aquatic plants. Use this sensor for an accurate on site test of dissolved oxygen concentration in a stream or lake survey, in order to evaluate the capability of the water to support different types of plant and animal life. Measure Biological Oxygen Demand (B.O.D.) in water samples containing organic matter that consumes oxygen as it decays. Determine the relationship between the dissolved oxygen concentration and the temperature of a water sample. ML75m Dissolved Oxygen Sensor User s Guide 7

Storage and Maintenance of the Dissolved Oxygen Sensor Following the procedure outlined below will enhance the lifetime of your sensor. - Long term storage (more than 24 hours): Remove the membrane cap and rinse the inside and outside of the cap with distilled water. Shake the membrane cap dry. Also rinse a tip of the sensor. Reinstall the membrane cap loosely onto the sensor body for storage. Do not screw it on tightly. - Short term storage (less than 24 hours): Store the sensor with the membrane end submerged in about 2 cm of distilled water. Important: Storing the sensor in this manner for longer than 24 ours may result in damage to the membrane. - Polishing the metal electrodes: If the cathode (the small metal contact in the center of the electrode) and anode (the silver, metal surrounding the lower portion of the inner body) become discolored or appear corroded, polish them with the polishing strip that is provided with the sensor. Perform this operation only as needed to restore electrode performance (necessary circa once every year). Remove the membrane cap. Thoroughly rinse the inner elements of the sensor with distilled water to remove all filling solution. Cut a 2 cm piece from the polishing strip provided. Wet the dull (abrasive) side of the polishing strip with distilled water. Using a circular motion, gently polish the center glass element of the cathode (on the very end of the electrode). Polish only enough to restore a bright, clean surface to the center element. Next, polish the silver anode located around the base of the electrode inner element. Polish only enough to restore a silver appearance. NOTE: Aggressive polishing will damage the sensor inner elements. Be sure to use only gentle pressure when performing the polishing of the anode and cathode. When you have completed the polishing, rinse the cathode and anode elements thoroughly and dry with a lab wipe. With normal use, the Dissolved Oxygen sensor will last for years. The membrane cap will, however, require replacement after about 6 months of continuous use. Replacement of the membrane is recommended when your Dissolved Oxygen sensor will no longer respond rapidly during calibration or when taking D.O. readings. Use of your Dissolved Oxygen Sensor in samples that are non aqueous or in those that contain oil, grease, or other coating agents will result in shortened membrane life. Replacement membranes can be obtained from CMA. 8 ML75m Dissolved Oxygen Sensor User s Guide

Maintaining and replenishing the Sodium Sulfite Calibration Solution Having an oxygen free solution to perform a zero oxygen calibration point is essential for accurate readings with your Dissolved Oxygen sensor. The Sodium Sulfite Calibration Solution that was included with your sensor will last a long time, but not indefinitely. Here are some suggestions for maintaining and replacing this solution: After your first use of the solution for calibration, the solution will no longer be brim full (some overflow results when the sensor is inserted into the solution). If you cap the solution with an air space above the sensor, oxygen gas in the space will dissolve in the sodium sulfite solution as a result, the solution may not be oxygen free. To prevent this from occurring, before putting on the lid, gently squeeze the bottle so the level of the solution is at the very top of the bottleneck; with the solution at this level, screw on the lid. The bottle will remain in this collapsed position. Using this procedure, the 2.0 M Na 2 SO 3 should remain oxygen free for a long period of time. If the calibration voltage reading displayed during the first calibration point is higher than in previous calibrations, it may be time to replace the solution, as described below. The 2.0 M sodium sulfite (Na 2 SO 3 ) solution can be prepared from solid sodium sulfite crystals: add 25.0 g of solid anhydrous sodium sulfite crystals (Na 2 SO 3 ) to enough distilled water to yield a final volume of 100 ml of solution. The sodium sulfite crystals do not need to be reagent grade; laboratory grade will work fine. Prepare the solution 24 hours in advance of doing the calibration to ensure that all oxygen has been depleted 1. If solid sodium sulfite is not available, you may substitute either 2.0 M sodium hydrogen sulfite solution, (20.8 g of NaHSO 3 per 100 ml of solution) or 2.0 M potassium nitrite (17.0 g of KNO 2 per 100 ml of solution). Using the Dissolved Oxygen sensor with other sensors The Dissolved Oxygen Sensor interacts with some other sensors, if they are placed in the same solution (in the same aquarium or beaker, for example), and they are connected to the same interface. This situation arises because the Dissolved Oxygen sensor outputs a signal in the solution, and this signal can affect the reading of another sensor. The Conductivity, Salinity and ph sensors cannot be connected to the same interface as a Dissolved Oxygen sensor and placed in the same solution. 1 Adding one or two crystals of solid cobalt chloride solid (CoCl 2 ) to 100 ml of the sodium sulfite solution will catalyze the initial removal of oxygen. ML75m Dissolved Oxygen Sensor User s Guide 9

Effect of salt concentration on dissolved oxygen (at salinity levels > 1000 mg/l) The Dissolved Oxygen concentration for air saturated water at various salinity values, DO(s), can be calculated using the formula: DO(s) = DO (k * s) where DO(s) is the concentration of dissolved oxygen (in mg/l) in salt water solutions. DO is the dissolved oxygen concentration for air saturated distilled water as determined from Table 1. s is the salinity value in ppt (part per thousand). Salinity values can be determined using the Conductivity or Salinity sensor. k is a constant. The value of k varies according to the sample temperature, and can be determined from Table 3. Temp ( C) Constant, k Temp ( C) Constant, k Temp ( C) Constant, k Temp ( C) Constant, k 1 0.08796 8 0.06916 15 0.05602 22 0.04754 2 0.08485 9 0.06697 16 0.05456 23 0.04662 3 0.08184 10 0.06478 17 0.05328 24 0.04580 4 0.07911 11 0.06286 18 0.05201 25 0.04498 5 0.07646 12 0.06104 19 0.05073 26 0.04425 6 0.07391 13 0.05931 20 0.04964 27 0.04361 7 0.07135 14 0.05757 21 0.04854 28 0.04296 Table 3. Salinity correction constant values Example: Determine the saturated DO calibration value at a temperature of 23 C and a pressure of 750 mm Hg, when the Dissolved Oxygen Sensor is used in seawater with a salinity value of 2.0 ppt 2 (2000 mg/l NaCl). First, find the dissolved oxygen value in Table 1 (DO = 8.55 mg/l). Then find k in Table 3 at 23 C (k = 0.04662). Substitute these values, as well as the salinity value, into the previous equation: DO(for 2 ppt) = DO (k * s) = 8.55 (0.04662 * 2) = 8.55 0.09324 = 8.46 mg/l Use the value 8.46 mg/l when performing the saturated DO calibration point (watersaturated air) as described in the Calibration section. The Dissolved Oxygen Sensor will be then calibrated to give correct DO readings in salt water samples with a salinity of 2.0 ppt (2000 mg/l NaCl). 2 parts per thousand 10 ML75m Dissolved Oxygen Sensor User s Guide

Important: For most dissolved oxygen testing, it is not necessary to compensate for salinity; for example, if the salinity value is 0.5 ppt (500 mg/l NaCl), using 25 C and 760 mm Hg, the calculation for DO(s) would be: DO(for 0.5 ppt) = DO (k * s) = 8.36 (0.04498 * 0.5) = 8.36 0.023 = 8.34 mg/l At salinity levels less than 1.0 ppt (1000 mg/l), neglecting this correction results in an error of less than 0.2%. Technical Specifications Sensor kind Measuring range Resolution Digital 16 bits resolution (on sensor digital conversion) communication via I2C 0.. 15 mg/l 0.0002 mg/l Accuracy Typical 2% after calibration at 25 C Maximal sampling rate Respond time 1 Hz Temperature compensation Automatic 5 35 C Pressure compensation Salinity compensation 95% of final readings in 30 s, 98% in 45 s Manual Manual Storage temperature 0 ~ 50 C Minimum sample flow 20 cm/s Note: Automatic temperature compensation does not mean that the reading for a saturated solution will be the same at two different temperatures the two solutions have different concentrations of dissolved oxygen, and the sensor reading should reflect this difference. ML75m Dissolved Oxygen Sensor User s Guide 11

Warranty: The Dissolved Oxygen sensor ML75m is warranted to be free from defects in materials and workmanship for a period of 12 months from the date of purchase provided that it has been used under normal laboratory conditions. This warranty does not apply if the sensor has been damaged by accident or misuse. Note: This product is to be used for educational purposes only. It is not appropriate for industrial, medical, research, or commercial applications. Rev. 10/06/2012 12 ML75m Dissolved Oxygen Sensor User s Guide