Catalogue Easy 9 Price list

Similar documents
The complete range of consumer switchboards and switchgear

R.C.C.B. s two-pole LEXIC

5SV Residual Current Protective Devices

Residual Current Circuit Breaker

SELECTION OF FINAL CIRCUIT PROTECTION

SURGE PROTECTIVE DEVICES

Electrical safety and protection devices

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

ASSEMBLED SOCKET-COMBINATIONS

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

How can a charging station for electric vehicles be set up simply and safely?

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Building Regulations P.4. Socket Outlets P.6. Other Considerations P.10. Training Seminars P.24

Residual Current Protective Devices

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Unified requirements for systems with voltages above 1 kv up to 15 kv

Technical guide Protection against earth faults with Residual Current Devices

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Electronic overload relay EF65, EF96 and EF146

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Circuit Breakers. Next Generation of Protection Capabilities

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electrical auxiliaries 0 For i DPN (DPN), C60 and C120

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Electrical Resistance Resistance (R)

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Electronic overload relay EF19 and EF45

The power distribution board that sets new standards

Safety technique. Emergency stop module BO 5988 safemaster

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Safety automation solutions

RM4TG20 three-phase network control relay RM4-T - range V

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Product and functional description

Manual Motor Starter MS 116 up to 16 A Technical Data

Three-phase monitoring relay CM-PFE

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Manual motor starter MS116

Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection

Catalog Edition DIN-Rail components for rolling stock applications

CompactLogix Power Supplies Specifications

Guide to the Selection & Use of Residual Current Devices

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Breaking and protection devices

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Quick Connect. quick - simple - efficient.

Power supply unit Model: PAC-SC50KUA

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

ADM1TE 5/30A DIN rail single phase two wire energy meter

GUIDELINES FOR ELECTRICAL WIRING IN RESIDENTIAL BUILDINGS

Bimetallic Overload Relay Specifications

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

Protection catalogue 15

6.0 Electrical Installations

Catalog. Modular DIN rail components Installation contactors

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Technicaldata General

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

RCD Type F Residual current protection for single phase inverters applications

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Technical catalogue. Modular DIN rail components Installation contactors

How To Build A Low Voltage Capacitor Lvcp

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Contact expansion modules

Actuator-Sensor-Interface

Use of Residual Current Devices in Departmental Infrastructure

Building Circuit Protection

White paper. ABB solutions for switching and protection of low speed wind turbines

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Unit 4: Electricity (Part 2)

Power Meter Series 700

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Contact expander modules

NZECP 14: 1995 ISSN COVER PAGE

IEC & 2 standard. The reference for safe and reliable LV switchboards

Secondary Unit Substations

Type-Tested Power Distribution Board 8PT with Rear Busbars. sivacon

E-STOP relays, safety gate monitors

How To Understand The Electrical Power Supply Of A Power Supply System

Relés e Contatores de Estado Sólido SIRIUS

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Thermistor motor protection

Transcription:

Easy 9 Catalogue Price list Miniature circuit breakers 6 ka Miniature circuit breakers 10kA Switch disconnectors Residual current Circuit-breakers Residual current devices with overcurrent protection Surge protection devices Contactors Impulse relays Comb busbars Switchboard enclosures

Easy9 Protection Circuit protection Miniature circuit breaker MCB18 Fast closing independent of the speed of actuation of the toggle. DB406017 Quality brands e Country approval pictograms PB111299-40 Easy9 monoconnect circuit breakers combine the following functions: Circuit protection against short-circuit currents Circuit protection against overload currents. Fault tripping indication on the front panel by the position of the handle. Curves B and C Connection DB405600 1000 100 Specification Rating Copper cables Rigid, finely stranded DB406001 14 mm 6.5 mm DB405599 DB122945 Flexible t(s) 10 1 to 40 A 1 to 25 mm 2 1 to 16 mm 2 50-63 A 1 to 35 mm 2 1 to 25 mm 2 1 PZ2 0,1 B C 0,01 1 3...5 6.4...9.6 I / In MCB selection for domestic applications (single-phase) Load Max. Rated power Curves Socket Quantity 16 A rated - - - 2 4 5 - - B 32 A rated - - - - - - - 1 B Maximum power (W) y 2000 y 3000 y 4500 y 7500 Lighting (W) Incandescent y 400 y 750 y 1000 y 2000 y 3000 B Fluocompact - - - - - - - - B LED - - - - - - - - B Air conditioner (ton) - 0.5 1 1.5 2 C Refrigerator (liters) 200 350 520 C Washing machine, dishwasher (W) 300 700 1000 1800 2500 C Domestic pump set - 0.5 HP 1 HP 2 HP B Water heater, cooking range, oven microwave, kettle, room heater, pressing iron (W) - y 750 y 1000 y 2000 y 3000 y 4500 y 6000 y 7500 B Cable Min cross section Copper 1 1 1 1.5 1.5 2.5 2.5 4 Aluminium 1.5 1.5 1.5 2.5 2.5 4 4 6 Circuit-breaker Max current rating (A) 2 4 6 10 16 20 25 32 2 Version : 1.0 18/10/2012 CE901001E

Miniature circuit breaker MCB18 3000 A - IEC 60898 PB107401-40 PB107405-40 PB107407-40 1P Circuit breakers Rating (In) Curve B Price Curve C Price 2 A - EZ9F33102 4 A - EZ9F33104 6 A EZ9F13106 EZ9F33106 10 A EZ9F13110 EZ9F33110 16 A EZ9F13116 EZ9F33116 20 A EZ9F13120 EZ9F33120 25 A EZ9F13125 EZ9F33125 32 A EZ9F13132 EZ9F33132 40 A EZ9F13140 EZ9F33140 50 A EZ9F13150 EZ9F33150 63 A EZ9F13163 EZ9F33163 Width in 9-mm modules 2 2P Circuit breakers Rating (In) Curve B Price Curve C Price 2 A - EZ9F33202 4 A - EZ9F33204 6 A EZ9F13206 EZ9F33206 10 A EZ9F13210 EZ9F33210 16 A EZ9F13216 EZ9F33216 20 A EZ9F13220 EZ9F33220 25 A EZ9F13225 EZ9F33225 32 A EZ9F13232 EZ9F33232 40 A EZ9F13240 EZ9F33240 50 A EZ9F13250 EZ9F33250 63 A EZ9F13263 EZ9F33263 Width in 9-mm modules 4 Circuit breakers Rating (In) Curve B Price Curve C Price 2 A - EZ9F33302 4 A - EZ9F33304 6 A EZ9F13306 EZ9F33306 10 A EZ9F13310 EZ9F33310 16 A EZ9F13316 EZ9F33316 20 A EZ9F13320 EZ9F33320 25 A EZ9F13325 EZ9F33325 32 A EZ9F13332 EZ9F33332 40 A EZ9F13340 EZ9F33340 50 A EZ9F13350 EZ9F33350 63 A EZ9F13363 EZ9F33363 Width in 9-mm modules 6 Specific technical data According to IEC/EN 60898-1 Breaking capacity (Icn) Ph/Ph 400 V AC 3000 A 220 V AC 5000 A 127 V AC 5000 A Ph/N 230 V AC 3000 A Limitation class 1 Additional characteristics Electrical feeding By the Top Endurance (O-C) Electrical 4,000 cycles Mechanical 10,000 cycles Operating temperature -5 C to +60 C CE901001E Version : 1.0 18/10/2012 3

Easy9 Protection Earth leakage protection 0.5 ma 10 ma Muscular contraction Burns respiratory 40 ma Severe burns ventricular fibrilation 80 ma Severity of Injuries is closely related to intensity of current bbinjuries become serious when currents exceed 40 to 50 ma during one second. bbtheoretically, a 150 ma current flows through the body when a person touches a 230 V energised conductor under dry conditions. Perception Cardiac arrest 1 A Research worldwide shows that the intensity of current flowing through the body determines the extent and severity of an electric shock. 16 A RDC 30 ma 30 ma How RCDs operate in electrical installations By measuring the intensity difference between live and neutral conductors, RCDs actually detect the current flowing through the human body. If this current reaches the 30 ma limit, the RC trips within a few milliseconds, so preventing injury or worse. International wiring regulation IEC 60 364 Protection by means of a residual current protective device (RCD), shall be provided for: bbsocket outlets with a rated current not exceeding 20 A, that are for ordinary persons and intended for general use, and Mobile equipment with a current rating not exceeding 32 A for use outdoors. bbin rooms containing a bath or a shower. To comply with this regulation, just one RCD can protect all bathroom sockets and equipment. Bathroom Check RCDs regularly Testing the RCD every 3 months enables detection of any event that may have impaired its operation. 2 Version : 1.0 19/10/2012 CE902001E

Easy9 Protection Earth leakage protection Easy9 RCCB Positive contact indication fault tripping indication on the front panel by the position of the handle (O - I engraved) DB116619 Quality brands DB404807 Country approval pictograms e PB111307-40 The Easy9 RCCB residual current circuit breakers provide: Protection of persons against electric shock by direct contact (30 ma). Protection of persons against electric shock by indirect contact (u 100 ma). Protection of installations against the risk of fire (300 ma). Dimensions (mm) Connection DB406002 +N / 4P 1P+N / 2P 1P 72 54 36 18 5.5 79 1P:77.5 66.5 50 Specification Type Copper cables Rigid, finely stranded DB406001 14 mm 6.5 mm DB405599 DB122945 Flexible 87 82 45 Easy9 RCCB 1 to 35 mm 2 1 to 25 mm 2 5 75 PZ2 Weight (g) Type Easy9 MCB 2P 125 375 4P 500 Characteristics Main characteristics Insulation voltage (Ui) 440 V AC Pollution degree 2 Rated impulse withstand voltage (Uimp) 4 kv According to IEC/EN 60898-1 Making and breaking capacity (Im/IDm) Surge current withstand (8/20 μs) without tripping 500 A 250 Â Additional characteristics Degree of protection Device only IP20 (IEC 60529) Device in modular IP40 enclosure Insulation classe II Endurance (O-C) Electrical (AC1) 2000 cycles Mechanical 5000 cycles Overvoltage category (IEC 60364) IV Storage temperature -40 C to +85 C Tropicalisation (IEC 60068-1) Treatment 2 (relative humidity 95 % to 55 C) Hazardous substances RoHs 2003 compliant 4 Version : 1.0 19/10/2012 CE902001E

Easy9 RCCB IEC/EN 61008-1 BS EN 61008-1 PB111307-40 2P Residual current circuit breakers AC Rating (In) 30 ma Price 100 ma Price 300 ma Price 25 A EZ9R33225 EZ9R53225 EZ9R63225 40 A EZ9R33240 EZ9R53240 EZ9R63240 63 A EZ9R33263 EZ9R53263 EZ9R63263 80 A EZ9R33280 - - Width in 9-mm modules 4 PB111308-40 Residual current circuit breakers AC Rating (In) 30 ma Price 100 ma Price 300 ma Price 25 A EZ9R33325 - - 40 A EZ9R33340 - - 63 A EZ9R33363 - - 80 A EZ9R33380 - - Width in 9-mm modules 8 PB111309-40 4P Residual current circuit breakers AC Rating (In) 30 ma Price 100 ma Price 300 ma Price 25 A EZ9R33425 EZ9R33480 EZ9R63425 40 A EZ9R33440 EZ9R53440 EZ9R63440 63 A EZ9R33463 EZ9R53463 EZ9R63463 80 A EZ9R33480 - - Width in 9-mm modules 8 Offer selection see page 2 Offer 1 This sticker must be removed before publishing Specific technical data Main characteristics Voltage rating (Ue) 2P 127-230 - 240 V 400-415 V 4P 400-415 V Operating frequency 50/60 Hz ± 5 % Conditional rated short circuit With fuse 3000 A current (Inc/ IDc) With Easy9 MCB 3000 A Additional characteristics Operating temperature Electrical feeding -5 C to +60 C By the Top and the bottom CE902001E Version : 1.0 19/10/2012 5