30 X 40 POLE BARN 12 HIGH SIDE WALLS 12 WIDE X 10 HIGH SECTIONAL GARAGE DOOR OPTIONAL WINDOWS DETAILS INCLUDED

Similar documents
Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

POST AND FRAME STRUCTURES (Pole Barns)

Superform Products Ltd.

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

TYPICAL PATIO COVERS 111

Residential Decks. Planning and Development Services Department

Additions and Alterations

COMMONLY USED RESIDENTIAL BUILDING CODES

Residential Deck Safety, Construction, and Repair

STANDARD OPEN PATIO COVER

SUPER SHED. Indoor shelter for your outdoor tools.

Pole Building Estimate Number: /2/2010 NORTH SIDE-EAVE SIDE 2 ELEVATION

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

1/2" CDX PLY W/ 6"/ 6"/ 12" 2x ROOF 16"OC W/ R-30 BATT. INSUL. (COMMON NAILS)

1. Concrete: T W L / 27 = Concrete C.Y. Multiply Feet Thickness x Feet Width x Feet Length / 27 = Cubic Yards.

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Best Barns USA Assembly Book

Section A Roof Truss

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

The minimum reinforcement for the stem wall is the placement of:

609 West Rock Road, Radford,VA / (fax) RECOMMENDED ATTACHMENTS & CONNECTION DETAILS

Chapter 3 Pre-Installation, Foundations and Piers

MUNICODE SERVICES LTD.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Residential Foundations and Basements

How to secure your property after a disaster

Patio Covers / Carports

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

DENVER MODEL 30 X 30 SPECIFICATIONS

ATLANTA MODEL SPECIFICATIONS

NAVAJO COUNTY ADDENDA & ADDITIONS TO THE INTERNATIONAL BUILDING CODES. Public Works/Planning & Zoning Building & Safety AMENDED ( )

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

UNIVERSAL ASSEMBLY INSTRUCTIONS FOR VERSATUBE BUILDINGS CONTRACTOR SERIES 2 X 4 FRAMES

PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings

2.9 WINDOW & DOOR BUCKS

Chapter 6 ROOF-CEILING SYSTEMS

Uncovered Decks & Porches

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

For the purposes of this Part, the following words shall have the following meanings:

March 14, Installation of Bay, Bow and Garden Windows

TORO STEEL BUILDINGS. BOLTS: o " diam. x " diam. x " diam. C.J. - Control Joints to minimize cracking.(0.

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Chapter. Restoration of Damaged Structures

INSTALLATION INSTRUCTIONS

Page & Turnbull imagining change in historic environments through design, research, and technology

COLORADO MODEL. 35 x 65 SPECIFICATIONS

HfHMD uses LP SmartSide siding and trim.

Chapter 3 FOUNDATIONS AND FOUNDATION WALLS

INSTALLATION OF A BAY WINDOW

IF YOU NEED A POLE BARN OR DIY KIT CALL NOW AND LETS MAKE A DEAL

Protecting Your Home From Hurricane Wind Damage

INFORMATION BULLETIN NO.

PANELIZED HOME INSTALLATION GUIDELINE

CALIFORNIA BUILDING CODE

Mark Cramer Inspection Services, Inc.

INFORMATION BULLETIN NO.

International Greenhouse Company

Structural Foundation System

FLAT ROOF CARPORT RECOMMENDED INSTRUCTION MANUAL

CARPENTRY - HOUSING. This is the sloping length of a right-angled triangle.

MANUFACTURED HOME INSTALLATION FOR PERMANENT FOUNDATIONS (TRANSVERSE FLOORS) (SUPPLEMENT TO MANUFACTURED HOME INSTALLATION MANUAL)

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010

Attached/Detached Patio Cover/Carport

DE Frame with C Series Sidelight

CHAPTER 6 CONSTRUCTION TYPES

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing

PART 1 GENERAL 1.1 SECTION INCLUDES

AMERICAN GOTHIC PLAYHOUSE

Ver. 2. Guide to. Inspecting Residential Brick Veneer

ONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

Owner's Manual & Assembly Instructions

Lighthouse Engineering, L.L.C.

Owner's Manual & Assembly Instructions

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

Basic Requirements for Residential Plan Review _

8/18/14. Introduction to. Framing. Terminology and Concepts

Featuring TJ Rim Board and TimberStrand LSL

Hunter College school of Social Work Thesis Proposal

Designed and Engineered to Perform

Brick Veneer Construction

EAST LYME HIGH SCHOOL

Electrical Wiring Technical Bulletin

Typical Deck Details

LIGHT FLOOR AND WALL FRAMING

Georgia Association of Home Inspectors

CITY OF SELMA, TEXAS Inspection Checklist: Commercial

SECTION 3 ONM & J STRUCTURAL ANALYSIS

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

Happily PHOTOGRAPHY BY MICHAEL ANDERSON AND LARRY OKREND

SECTION 1 GENERAL REQUIREMENTS

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Transcription:

30 X 40 POLE BARN 12 HIGH SIDE WALLS 12 WIDE X 10 HIGH SECTIONAL GARAGE DOOR OPTIONAL WINDOWS DETAILS INCLUDED 3 ENTRY DOOR METAL ROOF METAL SIDING GABLE ROOF, 4/12 PITCH

INDEX PAGE DESCRIPTION 1 FRONT & RIGHT ELEVATIONS 2 BACK & LEFT ELEVATIONS 3 PLAN, FOOTING PLAN 4 SECTION A, VIEW A, RAFTER TO PLATE FASTENER USE ILLUSTRATION 5 SECTION B, THICKENED EDGE SLAB DETAIL 6 WINDOW FRAME DETAIL, SECTIONS E, F, G 7 PERSONNEL DOOR FRAME SECTION H, GARAGE DOOR FRAME DETAILS, SECTIONS C6 &C8 8 NOTCHING DETAILS, SECTION D 9 FOOTING OPTIONS DETAILS 10 PERSONNEL DOORWAY FRAME, FRAME PICTORIAL 11 SPECIFICATIONS, BILL OF MATERIALS TITLE PAGE 463 North State, Preston, Idaho 83263 COPYRIGHT 2003 SCALE NTS PAGE

METAL ROOFING METAL FASCIA RUN 12 RISE 4 PEAK HEIGHT CEILING HEIGHT 2" ROOFING EXTENTION PAST WALL 17'-7" GRADE METAL CORNER TRIM INSTALL DOOR TRIM AFTER DOOR INSTALLATION TO ENSURE PROPER FIT AGAINST DOOR METAL SIDING FRONT ELEVATION METAL ROOFING VENTED RIDGE PEAK HEIGHT METAL FASCIA CEILING HEIGHT 17'-7" GRADE METAL CORNER TRIM METAL SIDING RIGHT ELEVATION FRONT & RIGHT ELEVATIONS 463 North State, Preston, Idaho 83263 COPYRIGHT 2003 SCALE 1/8" = 1' PAGE 1

METAL ROOFING METAL FASCIA RUN 12 RISE 4 PEAK HEIGHT CEILING HEIGHT 2" ROOFING EXTENTION PAST WALL 17'-7" GRADE METAL CORNER TRIM METAL SIDING BACK ELEVATION METAL ROOFING VENTED RIDGE PEAK HEIGHT METAL FASCIA CEILING HEIGHT 17'-7" GRADE METAL CORNER TRIM METAL SIDING LEFT ELEVATION BACK & LEFT ELEVATIONS 463 North State, Preston, Idaho 83263 COPYRIGHT 2003 SCALE 1/8" = 1' PAGE 2

30' 8' 7' 7' 8' B 5 Ø2'-3/4" Ø1'-6" Ø1'-6" Ø1'-6" Ø2'-3/4" 8' 8' 8' 8' 8' A 4 3'x6'8" EXT. DOOR x10' SECTIONAL GARAGE DOOR 3'-6" 40' Ø2'-3/4" NOTE: FOOTING SIZE BASED ON 1000 PSF. SOIL BEARING CAPACITY. (FOR 1500 PSF SEE FOOTING ALTERNATIVES IN SPECIFICATIONS) DOOR FRAME FOOTINGS CENTERED UNDER MIDDLE OF DOOR FRAME ASS'Y Ø1'-6" Ø1'-6" Ø10" Ø10" Ø2'-3/4" 8'-9" 8" DIA 8'-10 1/2" 6x6-6" 8" DIA -3" 6x6 PLAN SCALE 1/8" = 1' 8'-9" 8" DIA 8'-10 1/2" 6x6 PLAN, FOOTING PLAN 463 North State, Preston, Idaho 83263 COPYRIGHT 2003 FOOTING PLAN SCALE 1/8" = 1' PAGE 3

VIEW A-4 METAL ROOFING 2x4 BLOCKING (ON END TRUSS) 2x4 PURLINS @24" O.C. 2x12 BEAM INSET INTO OF ENGINEERED TRUSS 4/12 PITCH, 40 PSF LL, 15 PSF DL @ 24" O.C. BLOCK PER CODE AND MANUFACTURER'S SPECIFICATIONS SIDING BUTTS AGAINST UNDER SIDE OF ROOFING CEILING HEIGHT 2x6 NAILER INSET DEEP INTO OF 3 ROWS PRESSURE TREATED OR EQUAL 2x6 INSET DEEP INTO OF SEE DOOR FRAME DETAIL PAGE 7 5'-4 1 2 " 7'-4 1 2 " 9'-4 1 2 " 8" DIA. DFL # 2 OR EQUAL (6x6 ALTERNATE SIZE) CONC. FTG. SEE OPTIONS PAGE 9 9' 9' 4' 1'-4 1 2 " 3'-4 1 2 " GRADE ENGINEERED TRUSS SECTION A-3 SCALE: 1/8" = 1' 2x6 BLOCKING 2x8 TOP PLATE (2x6 W/6x6 ) 1 3/4"X7 1/4" LVL BEAM INSET 1 3/4" DEEP INTO OF 1 3/4"X7 1/4" LVL BEAM INSET INTO INSIDE OF FLUSH WITH EDGE OF TOP PLATE METAL SIDING VIEW A-4 SCALE: 1/4" = 1' 2x8 TOP PLATE (2x6 W/6x6 ) 2x12 BEAM INSET DEEP INTO OF TIE PER CODE ALL TRUSSES RAFTER TO PLATE FASTENER USE ILLUSTRATION SCALE: NTS SECTION A, VIEW A, RAFTER TO PLATE FASTENER USE ILLUSTRATION 463 North State, Preston, Idaho 83263 COPYRIGHT 2003 PAGE 4

METAL FASCIA 2x8 TOP PLATE (2x6 W/6x6 ) 2x12 BEAM INSET INTO OF ENGINEERED TRUSS 4/12 PITCH, 40 PSF LL, 15 PSF DL @ 24" O.C. BLOCK PER CODE AND MANUF'S SPECIFICATIONS METAL ROOFING 2x4 PURLINS @ 24" O.C. 1 3/4"X7 1/4" LVL BEAM INSET INTO INSIDE OF FLUSH WITH EDGE OF TOP PLATE GRADE 9'-4 1 2 " 7'-4 1 2 " 5'-4 1 2 " 3'-4 1 2 " 1'-4 1 2 " 4' 2x6 NAILERS INSET INTO OF 3 ROWS PRESSURE TREATED OR EQUAL 2x6 INSET DEEP INTO OF CONC. FTG. SEE OPTIONS PAGE 9 8" DIA. DFL # 2 OR EQUAL (6x6 ALTERNATE SIZE) SECTION B-3 SCALE: 1/8" = 1' SEE DOOR FRAMING DETAILS PAGE 7 METAL SIDING 1' 3" 1' #4 REBAR THICKENED EDGE SLAB DETAIL SCALE: 1/2" = 1' NOTE: WHEN A CEMENT IS USED, SET THE HEADER FOR THE 3'x6'-8" ENTRY DOOR TO 6'-9 1/2" ABOVE THE TOP OF THE SLAB INSTEAD OF FROM GRADE SO THE DOOR WILL CLEAR THE CEMENT. THE CEMENT IS TO BE ON A 4" THICK BED OF COMPACTED GRAVEL OR SAND AND REINFORCED W/ 6x6-6/6 WWM AND REBAR PER CODE. THICKEN THE EDGE OF THE SLAB AT THE GARAGE DOOR TO 12"x12" MINIMUM WITH 2-#4 HORIZONTAL REBAR MIN. 3 INCHES FROM THE BOTTOM. SECTION B, THICKENED EDGE SLAB DETAIL 463 North State, Preston, Idaho 83263 COPYRIGHT 2003 PAGE 5

2x4 INSIDE TRIMMER 2x4 TRIMMER NOTCH TO FIT AROUND NAILERS 2x4 TRIMMER BACKER TOP PLATE 2x4 TRIMMER NOTCH TO FIT AROUND BEAMS SECTION E-6 SCALE 1/2" = 1' 2x4 ROUGH SILL BEAM 2x6 NAILERS 3 ROWS PRESSURE TREATED OR EQUAL 2x6 E 6 DOUBLE 2x6 HEADER W/ 1/2" SPACER BETWEEN 2x4 INSIDE TRIMMER 2x4 TRIMMER BACKER 2x6 NAILERS 2x4 TRIMMER PRESSURE TREATED OR EQUAL NOTCH TO FIT AROUND BEAMS 3 ROWS PRESSURE TREATED OR EQUAL 2x6 SECTION F-6 SECTION G-6 SCALE 1/4" = 1' SCALE 1/4" = 1' 2x6 NAILER DOUBLE 2x6 HEADER W/ 1/2" SPACER BETWEEN 2x4 INSIDE TRIMMER 2x4 ROUGH SILL W/ DOUBLE 2x6 BEAM BENEATH 2x6 NAILER 2x4 INSIDE TRIMMER OR EQUAL NOTCH TO FIT AROUND NAILERS F 6 G 6 OPTIONAL WINDOW FRAME DETAIL ( ELEVATION VIEW) SCALE 1/4" = 1' 2x4 ROUGH SILL W/ DOUBLE 2x6 BEAM UNDERNEATH NOTE: 1. ILLUSTRATED WINDOW ROUGH OPENING IS 3'-0"x2'-6". 2. WINDOW HEADER HIEGHT IS 6'-9 1/2". 3. ADJUST ROUGH SILL HEIGHT AND WIDTH TO SUIT DESIRED WINDOW PER MANUFACTURES INSTRUCTIONS. 4. WINDOW FRAME MATERIALS ARE NOT ON BILL OF MATERIALS LIST. 2x4 INSIDE TRIMMER NOTCH TO FIT AROUND NAILERS WINDOW FRAME DETAIL, SECTIONS E, F, G 463 North State, Preston, Idaho 83263 COPYRIGHT 2003 PAGE 6

2x6 SPRING SUPPORT C6 7 2x12 INSIDE HEADER 2x6 TOP PLATE 2x4 TRIMMER BACKER TO BOTTOM SIDE OF TOP PLATE 2x12 BEAM 6x6 D6 8 TRIMMED 2x6 HEADER BOTTOM PLATE 6x6 10' ABOVE GRADE OR CONC. 2x6 INSIDE TRIMMER 6'-9 1/2" LONG 2x6 TRIMMER TO BOTTOM OF LVL BEAM MIN. R.O. 3'-2" 2x6 TRIMMER OR EQUAL GARAGE DOOR FRAME DETAIL (SECTION A-3 VIEW, 6x6 ) SCALE 1/8" = 1' SECTION H-10 SCALE: 1/4" = 1' 2x6 SPRING SUPPORT 2x12 INSIDE HEADER 2x6 SPRING SUPPORT 2x12 INSIDE HEADER 2x8 HEADER BOTTOM PLATE SECTION C8-7 (8" DIA ) SCALE 1/4" = 1' 2x6 HEADER BOTTOM PLATE TRIMMED TO 4" SECTION C6-7 (6x6 ) SCALE 1/4" = 1' 8 3/4" 2x6 TOP PLATE 2x6 SPRING SUPPORT BACKER 2x12 BEAM 2x12 HEADER 2x6 TRIMMER 2x8 TOP PLATE 2x6 SPRING SUPPORT BACKER 2x12 BEAM 2x12 HEADER 2x10 TRIMMER CUT DOWN TO 8 3/4" 2x6 SPRING SUPPORT 2x12 BEAM 2x10 TRIMMER CUT DOWN TO 8 3/4" OR EQUAL PERSONNEL DOOR FRAME SECTION H, GARAGE DOOR FRAME DETAILS, SECTIONS C6 &C8 463 North State, Preston, Idaho 83263 COPYRIGHT 2003 D8 8 2x8 HEADER BOTTOM PLATE C8 7 GARAGE DOOR FRAME DETAIL (SECTION A-3 VIEW, 8" DIA ) SCALE 1/8" = 1' 2x12 INSIDE HEADER 2x8 TOP PLATE 10' ABOVE GRADE OR CONC. 2x4 PRESSURE TREATED OR EQUAL BRACKET HOLDER PAGE 7

SIDE EDGE (4" W/6x6) 1 3/4" END EDGE END EDGE SIDE EDGE (4" W/6x6) 1 3/4" 7 1/4" SIDE SURFACE TOP VIEW (4" W/6x6) 1 3/4" VIEW FROM FRONT OF AT LEFT SIDE SIDE NOTCHING DETAIL SCALE 1/2" = 1' END SURFACE 11 1/4" TOP VIEW SIDE VIEW BACK END NOTCHING DETAIL SCALE 1/2" = 1' END SURFACE 22 1/2" TOP VIEW SIDE VIEW FRONT END NOTCHING DETAIL SCALE 1/2" = 1' SIDE SURFACE 11 1/4" 11 1/4" TOP VIEW (4" W/6x6) 1 3/4" 7 1/4" VIEW OF FRONT LEFT CORNER FROM FRONT OF 1/4" SPACE BETWEEN NAILER AND FRAME NAILER TRIM 2x4 CORNER TO FIT 2x4 BRACKET HOLDER SCREW TO, FRAME & TOP PLATE 2x6 OR EQUAL FRAME SCREW TO 8 3/4" 2x10 TRIMMER CUT DOWN TO 8 3/4" OR EQUAL SECTION D8-7 SECTION D6-7 (8" VERSION) (6x6 VERSION) SCALE 1/2" = 1' SCALE 1/2" = 1' NOTCHING DETAILS, SECTION D 463 North State, Preston, Idaho 83263 COPYRIGHT 2003 NAILER LET INTO NOTCHED FOR BEAMS AND NAILERS 2x6 TRIMMER PRESSURE TREATED OR EQUAL END SURFACE VIEW OF RIGHT FRONT CORNER FROM RIGHT SIDE OF PAGE 8 7 1/4" CORNER NOTCHING DETAIL SCALE 1/2" = 1'

TAMPED FILL TREATED WOOD 9" MIN. TAMPED FILL CONCRETE FOOTING CONCRETE FOOTING REINFORCE PER CODE MIN. SIZE PER PAGE 3 GRAVEL 9" MIN. MIN. SIZE PER PAGE 3 CONCRETE FOOTING REINFORCE PER CODE CONCRETE BACKFILL TREATED WOOD CONCRETE BACKFILL 4" MIN. TAMPED FILL TREATED WOOD 12" MIN. GALVANIZED METAL STRAP 2'-0" MAX. FOR USE IN TEMPERATE CLIMATES (FROST LINE NO DEEPER THAN 2'-0") REINFORCED CONCRETE COLLAR FROST LINE MIN. SIZE PER PAGE 3 LAG BOLTS CONCRETE COLLAR REINFORCE PER CODE GRAVEL TAMPED FILL TREATED WOOD TREATED WOOD 9" MIN. CONCRETE FOOTING REINFORCE PER CODE SPIKES OR LAG SCREWS MIN. SIZE PER PAGE 3 CONCRETE FOOTING WITH SPIKED ANCHORAGE 9" MIN. CONCRETE FOOTING WITH STRAP ANCHOR CONCRETE FOOTING REINFORCE PER CODE MIN. SIZE PER PAGE 3 FOOTING OPTIONS DETAILS 463 North State, Preston, Idaho 83263 COPYRIGHT 2003 SCALE NTS PAGE 9

2x8 TOP PLATE (2x6 W/6x6 ) 1 3/4"X7 1/4" LVL BEAM 2x6 NAILERS 3 ROWS PRESSURE TREATED OR EQUAL 2x6 6'-9 1/2" H 7 2-2x4 HEADER SPACED TO PTDFL 2x6 OR EQUAL TRIMMER NOTCHED TO FIT AROUND NAILERS PTDFL 2x4 OR EQUAL TRIMMER BACKER DOOR FRAME FOOTING PER CODE PTDFL 2x6 OR EQUAL INSIDE TRIMMER PERSONNEL DOORWAY FRAME ELEVATION DETAIL SCALE 1/4" = 1' CONSTRUCTION INFORMATION. FRAME PICTORIAL SCALE NTS PERSONNEL DOORWAY FRAME, FRAME PICTORIAL 463 North State, Preston, Idaho 83263 COPYRIGHT 2003 NOTE: FRAME PICTORIAL IS ONLY TO GIVE A GENERAL IDEA OF HOW FRAME PARTS FIT TOGETHER IT IS NOT AN ACTUAL REPRESENTATION OF THE FINISHED FRAME. USE THE DETAILED DRAWINGS FOR ACTUAL PAGE 10

General Specifications and Notes General: 1. Construction shall meet all applicable codes and ordinances. Site Work: 1. Make sure setbacks are in compliance with local building codes. 2. All stumps, roots, and organic matter shall be removed from the soil in the area of the building. 3. Lot must be graded to insure proper drainage away from building. 4. Soil should not be a highly expansive soil type without having a soil report preformed by a soils engineer and receiving approval from local building department to construct building on said type soil. 5. Soil bearing capacity assumed to be 1000 psi at 2' below adjacent finished grade for design. Concrete: 1. All slabs are to be 4" concrete over 4" gravel unless otherwise noted on the plans. 2. Concrete to be ACI 301-66, Type II cement, 2500 psi at 28 days, 5" maximum slump. 3. Reinforcing to be ASTM A 615-Bars with Fy=60 ksi lap 40 diameter minimum at splices or weld per ACI Std. in footings. 4. Reinforcing to be ASTM A 185-welded wire mesh in slabs. Roof Framing: 1. For spans and dimensions refer to plans. 2. Use Simpson or equal anchors at each truss to wall connection 3. Use Simpson or equal anchors at plate to beam or plate to nailer joints. General framing: (Douglas Fir) 1. Exterior wall framing to be as shown on drawings. 2. Framing lumber shall be Douglas Fir construction grade Fb 1450 or better unless otherwise noted. 3. Use pressure treated posts and use redwood or pressure treated lumber for nailers closer than 8" to the ground and for any other use where the lumber is closer than 8" to the ground or on cement. Door and window framing: 1. Door and window manufacturer specified rough opening dimensions shall take precedence over drawing rough opening dimensions if there is a conflict. Footing Alternatives: 1. For soil bearing capacity of 1500 psf the footings listed on page 3 as are lowered to Ø2'-4 1/2", the footings listed as Ø2'-3/4" are lowered to Ø1'-8 1/4", all other footings and pads remain the same as stated on page 3. SPECIFICATIONS, BILL OF MATERIALS 463 North State, Preston, Idaho 83263 COPYRIGHT 2003 BILL OF MATERIAL Size Item Count Unit 2 x 12 x 8' top beam 2 ea 2 x 12 x 10' top beam 2 ea 2 x 12 x 14' top beam 2 ea 2 x 12 x 14' garage door header 2 ea 1 3/4" x 7 1/4" x 40' LVL top beam 4 ea 2 x 10 x 10' garage door trimmer, pressure treated 2 ea 2 x 8 x 8' top plate 4 ea 2 x 8 x 10' top plate 2 ea 2 x 8 x14' top plate 2 ea 2 x 8 x14' garage door header bottom plate 1 ea 2 x 8 x16' top plate 4 ea` 2 x 6 x 11 1/4" spring support 1 ea 2 x 6 x 21 spring support backer 1 ea 2 x 6 x 8' beam 16 ea 2 x 6 x 10' beam 8 ea 2 x 6 x 14' beam 4 ea 2 x 6 x 16' beam 16 ea 2 x 6 x 8' beam, pressure treated 12 ea 2 x 6 x 10' beam, pressure treated 6 ea 2 x 6 x 11'-10 1/2" garage door frame, pressure treated 2 ea 2 x 6 x 14' beam, pressure treated 3 ea 2 x 6 x 16' beam, pressure treated 12 ea 2 x 4 x 8' purlin 18 ea 2 x 4 x 16' purlin 36 ea 2 x 4 x 6'-10" entry door frame, pressure treated 2 ea 2 x 4 x 9'-1 3/4" entry door frame, pressure treated 2 ea 2 x 4 x 11'-10 1/2" entry door frame, pressure treated 2 ea 2 x 4 x bracket holder, pressure treated 2 ea 3'x13' Siding, Vertical 49 ea 2x12x40" entry door header 2 ea 1x4-16ft+ entry door casing 18 ft entry door jamb, ext. side 18 ft TR-1 360" roof truss 2 ea TR-0 360" roof truss 19 ea 3'x16' Roofing Metal 27 ea metal angle gable fascia 64 ft ridge cap 40 ft 36x80x1 3/4L ext. hinged door 1 8" dia. X 16' long pressure treated post 17 garage door trim 32 ft x 10' sectional garage door 1 ea This is a computer generated estimate of the materials needed. It is not to be construed as an accurate or complete list of materials. For a more accurate list of materials needed, you will have to calculate it by hand. SCALE NTS PAGE 11