conference preview Steel outriggers and trusses help solve the challenges of a Shanghai super-skyscraper s twisting design.

Similar documents
Commerzbank Head Office. Frankfurt am Main

Structural Systems for Tall Buildings Professor Mahjoub Elnimeiri, PhD Fall Lecture 1

Chapter 6 ROOF-CEILING SYSTEMS

4B The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

A 38-story design-build steel structure features a staggered-truss frame

Ping An: Insurance and Tall Buildings

OPTIMAL DIAGRID ANGLE TO MINIMIZE DRIFT IN HIGH-RISE STEEL BUILDINGS SUBJECTED TO WIND LOADS

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

How To Build The Burj Dubai Tower

CE591 Lecture 8: Shear Walls

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

Detailing of Reinforcment in Concrete Structures

Hunter College school of Social Work Thesis Proposal

EFFECTS ON NUMBER OF CABLES FOR MODAL ANALYSIS OF CABLE-STAYED BRIDGES

COLUMN-FREE OFFICE SPACE RISES IN CHICAGO S LOOP

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

WORLD S TALLEST TIMBER BUILDING, BERGEN

How To Design A Post Tensioned Deck For A Building

Parametric modeling in AutoCAD By Neil C. Katz Skidmore, Owings & Merrill LLP October 11, 2008

Sapa Building System, first time at BAU

Tall buildings. Florea Dinu. Lecture 13: 25/02/2014

Chapter 3 Pre-Installation, Foundations and Piers

Brock Commons Phase 1 University of British Columbia, Vancouver, Canada

DESIGN OF NATURAL VENTILATION WITH CFD CHAPTER SEVEN. Qingyan Chen. difficult to understand and model, even for simple

Conceptual design and design examples for multi-storey buildings

Designer s NOTEBOOK DESIGN ECONOMY, PART 3

Conceptual Design and Analysis in Autodesk Revit Architecture 2011

First 14-storey wood building in the world at Bergen in Norway Premier bâtiment en bois à 14 niveaux au monde à Bergen en Norvège

GEORGE J. CAMBOURAKIS, P.E., C. ENG. PRESIDENT & CHIEF STRUCTURAL ENGINEER

Optimum proportions for the design of suspension bridge

Residential Deck Safety, Construction, and Repair

Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars

Technical Notes 3B - Brick Masonry Section Properties May 1993

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig some of the trusses that are used in steel bridges

Steel joists and joist girders are

Project Report. Structural Investigations Hotel del Sol Yuma, Arizona

Bracing Webs in Trusses that have Dissimilar Configurations

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, , ]

ETABS. Integrated Building Design Software. Concrete Shear Wall Design Manual. Computers and Structures, Inc. Berkeley, California, USA

Tall Building Form Generation by Parametric Design Process

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

Challenging Skew: Higgins Road Steel I-Girder Bridge over I-90 OTEC October 27, 2015 Session 26

US 51 Ohio River Bridge Engineering and Environmental Study

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Commercial Building Valuation Report

Elegance SC. Solar Control

TechPractices: Home Front Homes:

Elevating Your House. Introduction CHAPTER 5

CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE

Prepared For San Francisco Community College District 33 Gough Street San Francisco, California Prepared By

Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,

PROJECT SUMMARY. Scope of work details: (If phased construction, please see plan submittal guidelines.)

ARCH 331 Structural Glossary S2014abn. Structural Glossary

Truss. are both simple and A Matsuo Example continuous trusses. The

The Collapse of Building 7 by Arthur Scheuerman December 8, 06

MANUFACTURED HOME INSTALLATION FOR PERMANENT FOUNDATIONS (TRANSVERSE FLOORS) (SUPPLEMENT TO MANUFACTURED HOME INSTALLATION MANUAL)

6 RETROFITTING POST & PIER HOUSES

INTRODUCTION TO BEAMS

Design of reinforced concrete columns. Type of columns. Failure of reinforced concrete columns. Short column. Long column

SRISHTI TECHNICAL SERVICES L.L.C

SEISMIC RETROFITTING OF STRUCTURES

The elements used in commercial codes can be classified in two basic categories:

Safe & Sound Bridge Terminology

Building skin and energy efficiency in a hot climate with particular reference to Dubai, UAE

Autodesk Robot Structural Analysis Professional Break it down before you build it up.

Brief on the Construction Planning of the Burj Dubai Project, Dubai, UAE

EAST LYME HIGH SCHOOL

THE COMPOSITE DISC - A NEW JOINT FOR HIGH POWER DRIVESHAFTS

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Uniform Construction Code (UCC) Manufactured Homes. Modular Homes. Building Permit Application Package

METHOD OF STATEMENT FOR STATIC LOADING TEST

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two

POST AND FRAME STRUCTURES (Pole Barns)

The Analysis of Open Web Steel Joists in Existing Buildings

THE ARTICULATED FUNICULATOR and the TUBED MEGA FRAME. The way of the FUTURE

Common Errors in Truss Design

EVALUATION OF SEISMIC RESPONSE - FACULTY OF LAND RECLAMATION AND ENVIRONMENTAL ENGINEERING -BUCHAREST

Wisconsin Building Products Evaluation

CH. 2 LOADS ON BUILDINGS

Introduction...COMB-2 Design Considerations and Examples...COMB-3

Chapter 3 - Structural Design

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM

USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch

Steel, Diagrid, Stability Systems, Architecturally Exposed Structural Steel

Rethinking conventional construction: An interview with Broad Group chairman and CEO Zhang Yue

System. Stability. Security. Integrity. 150 Helical Anchor

FORM DESIGN. easy to work with, and generally available.

8/18/14. Introduction to. Framing. Terminology and Concepts

Five reasons buildings fail in an earthquake and how to avoid them

Aluminium systems profile selection

Retrofitting By Means Of Post Tensioning. Khaled Nahlawi 1

Tyfo Fibrwrap Blast Panels. Prefabricated Blast Wall System

ADVANCED SYSTEMS FOR RATIONAL SLAB REINFORCEMENT

Forensic engineering of a bored pile wall

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

SUSPENSION TRAIL BRIDGE USING SUSTAINABLE MATERIALS

Seismic performance evaluation of an existing school building in Turkey

Transcription:

conference preview Shanghai Sky by Dennis Poon, P.E. Steel outriggers and trusses help solve the challenges of a Shanghai super-skyscraper s twisting design. The Shanghai Tower is in good company. The super-tall skyscraper, currently under construction in the Pudong district of Shanghai, China, and scheduled to be completed next year, is in close proximity to two other giants that have transformed the Shanghai skyline in recent years: the Jin Mao Tower and the Shanghai World Financial Center. As a matter of fact, once completed the Shanghai Tower will reach 2,074 ft high 121 stories and will be the secondor third-tallest building in the world. The total floor area of 4,090,285 sq. ft will house Class-A office space, retail space, a luxury hotel, cultural venues and the world s highest non-enclosed observation deck; the building will anchor one of East Asia s leading financial centers, the Lujiazui Finance and Trade Zone. The tower s program is organized into nine vertical zones, each rising from a sky lobby, a light-filled garden atrium that creates a sense of community and supports daily life with a mixed-use program catering to tenants and visitors; the lobbies function much like traditional town plazas and squares, bringing people together throughout the day. Dennis Poon is a vice chairman with, Inc., and is located in the firm s New York office. You can reach him at dpoon@thorntontomasetti.com. In the Zone Faced with many geographical challenges a windy climate, active earthquake zone and clay-based soils typical of a river delta the structural engineers sought to simplify the building structure as much as possible. The heart of the building is a composite concrete core, about 30 sq. meters (323 sq. ft) in plan. Structural steel columns, beams and plates are embedded in the core in the low zones to increase the capacity of the core. The core acts in concert with an outrigger and composite supercolumn system. There are four paired supercolumns, two at each end of each orthonormal axis. In addition, four diagonal supercolumns along each 45 axis are required by the long distances at the base between the main orthonormal supercolumns. The two-story-tall outriggers and belt trusses are structural steel and the supercolumns are composite structures with concrete-encased steel vertical sections. The tower is divided vertically into nine zones, each with 12 to 15 floors, and an inner cylindrical tower steps in at each zone. At the interface of the adjacent zones, a two-story, full-floor area houses mechanical, electrical and plumbing equipment and also serves as that zone s life safety refuge area. This full-floor platform creates a base for the atrium spaces directly above. Above the topmost zone is the tower crown. Built to enclose MEP equipment, the structure is framed with a series of vertical steel fin trusses and horizontal struts to kick back to the core wall. The fin trusses are spaced roughly 14.5 ft apart and are 6.6 ft deep, and the tallest truss is approximately 233 ft. The lateral and vertical resistance of the tower is provided by the inner cylindrical tower, and the primary lateral resistance is provided by the core, outrigger and supercolumn system. This system is supplemented by a mega-frame consisting of all the supercolumns, including the diagonal columns together with a double belt truss at each zone that picks up the zone s columns and the mechanical and refuge floors. The supercolumn and outrigger assemblies act as ski poles, stabilizing the building in high winds, earthquakes and typhoons common to the area, while also supporting the twisting-form curtain wall. The outrigger trusses and supercolumns derive stiffness from the concrete inner building, comprising an effective system for resisting wind and seismic loads for super tall buildings. Ample Analysis The building was designed to meet the performance-based design (PBD) requirements as specified in the China s seismic design code. In order to do this, the non-linear (plastic) behavior of the members and connections had to be determined. This was accomplished via the three-dimensional, finite element program, ABAQUS, which not only modeled the encased steel element, but also the concrete encasement itself. In ABAQUS, the concrete elements are modeled as shell elements and the steel elements are modeled as beam elements. The code provides the post-elastic behavior of the steel and concrete. The encased steel sections in the supercolumns are the key element to ensuring the proper performance of the connections and A trifecta of super-tall Shanghai skyscrapers: the Shanghai World Financial Center, Jin Mao Tower and the soon-to-becompleted Shanghai Tower. 62 MODERN STEEL CONSTRUCTION april 2013

Gensler april 2013 MODERN STEEL CONSTRUCTION 63

thus the performance of the structure. At the building core, localized vertical steel members are used to facilitate the outrigger connections and a similar 3D finite element analysis was performed. From these finite element analyses using ABAQUS, a moment, axial force and rotational deformation profile was created. Based on these profiles, using a performance-based program (Perform 3D) and ABAQUS, the performance of the primary structure was developed using seismic time history graphs for a similar soil profile as that of the site. The soil conditions in Shanghai are challenging from a seismic perspective defined in China s technical specification for concrete and composite tall structures as type IV, which approaches Class F classification in the International Building Code (IBC). The resulting foundation for the tower consists of bore piles one meter (3.28 ft) in diameter and 52 to 56 meters (170 to 184 ft) long. In total, the tower is supported on a 6-meterdeep (20-ft-deep) mat reinforced by 947 bore piles. Seven sets of seismic time histories that matched Shanghai s soil profile and earthquake intensity were modeled. From the performance-based design analysis, the following conclusions were reached: The average maximum drift ratio in either axis is less than 1/130. This meets the 1/100 limit specified in the China Building Code. The core wall stresses are elastic, except in limited areas. Most core wall link beams exhibit fully plastic deformations, and plastic hinge rotations are still within the limit set for Life Safety. Most outrigger trusses and belt trusses are within the elastic range. Embedded steel elements in supercolumns and core walls remained elastic. The Shanghai Center achieved the performance levels for life safety in the code. Gensler The Shanghai skyline as it will appear upon completion of the Shanghai Tower. A Revit model of the structure. A 3D stuctural model of one of the vertical zones of the building. 64 MODERN STEEL CONSTRUCTION april 2013

Starting with the supercolumn connections to the outrigger and belt trusses, the emphasis was on continuity of forces. The main axis of the supercolumns has an embedded steel built-up section coincident with the axis of the outrigger to simplify the connection. In the orthonormal direction, the belt truss frames into the supercolumn at a slightly non-orthonormal direction due to being in the circumferential direction. In the steel section of the supercolumns, there are perpendicular cross ribs that align with belt trusses. Any slight deviation of the cross ribs with the axis of the belt trusses is resolved by stiffeners within the embedded steel section. A similar detail is used at the intersection of the core and the outrigger. At this location there is a small embedded vertical steel column at the intersection, which simplified the outrigger connection to the core. At the levels of the outriggers, tie plates level with the outrigger top and bottom chord pass through the core. Double Skin Shanghai Tower will be one of the most sustainably advanced tall buildings in the world. A central aspect of its design and a main contributor to its environmental efficiency is the transparent, second skin that wraps the entire building. The ventilated atriums it encloses conserve energy by modulating the temperature within the void. The space acts as a buffer between the inside and outside, warming up the cool outside air in the winter and dissipating heat from the building interior in the summer. The tower is divided vertically into nine zones, each with 12 to 15 floors, and an inner cylindrical tower steps in at each zone. At the interface of the adjacent zones, a two-story, full-floor area houses MEP equipment and life safety refuge areas. april 2013 MODERN STEEL CONSTRUCTION 65

conference preview The design process revolved around a series of advanced parametric software programs (Rhino and Revit for the geometry and SAP 2000 for structural analysis), which allowed the design team to manipulate and refine the project s complex geometry iteratively, as well as a building information modeling (BIM) approach. The parametric platform played a pivotal role in assisting the design team to define the tower s unique and environmentally responsive shape, structure and façade. The façade is one of the defining features of the Shanghai Tower. The twisting design implements an inner and outer curtain wall system, which creates an inhabitable double-skin zone, and a flexible hanging curtain wall support structure was ultimately developed to suit the complex needs of the façade. The spiraling inclined curved outer skin features laminated glass panels that filter the sun, wind and rain. The inner skin encloses the interior space with a conventional low-e coated insulating glass curtain wall system with operable solar control devices. This double skin wall system takes advantage of the stack effect to provide natural ventilation and cooling. The buffer area between the inner and outer skins helps regulate the environment and collect and recycle rain water. When completed, Shanghai Tower won t simply be a skyscraper or even a super-skyscraper. It will represent a new way of envisioning and creating cities, and it will address the tremendous challenges faced by designers of super-tall buildings today. By incorporating cutting-edge sustainable design, weaving the building into the urban fabric and drawing community life high into the tower, the project is attempting to redefine the role of tall buildings for decades to come. This article serves as a preview of Session N34a/b at NASCC: The Steel Conference, taking place April 17-19 in St. Louis. Learn more about the conference at www.aisc.org/nascc. Owner The Shanghai Tower Construction and Development Company, Ltd. General Contractor Shanghai Construction Group Architect Gensler, Shanghai Structural Engineer, New York 66 MODERN STEEL CONSTRUCTION april 2013