Tyfo Fibrwrap Blast Panels. Prefabricated Blast Wall System
|
|
|
- Madlyn Booker
- 10 years ago
- Views:
Transcription
1 Tyfo Fibrwrap Blast Panels Prefabricated Blast Wall System
2 Tyfo Fibrwrap Blast Panels Prefabricated Blast Wall System DESCRIPTION Tyfo Fibrwrap Blast Panels are prefabricated composite walls comprised of the various Tyfo Fibrwrap Composite Systems. Typical panel dimensions are 10 feet wide and 12 feet tall with a panel thickness of 7.5 inches. Sizes do vary based on project-specific requirements. USE Tyfo Fibrwrap Blast Panels are unique, prefabricated composite walls. They are tested and custom designed to meet project-specific pressures and impulses associated with both accidental and terrorist explosions. Tyfo Fibrwrap Blast Panels can provide building envelope protection for blast mitigation or protection of interior space in industrial facilities. ADVANTAGES Does not use fiber reinforced concrete (FRC) or (ECC) Validated blast testing Prefabricated system Ease of installation Energy dissipating characteristics Mitigates high pressures and impulses Incorporates the rigorously tested Tyfo Fibrwrap Composites Fire tested per ASTM E119 * Weights and dimensions will vary based on the project parameters. MOMENT PLASTIC MOMENT FIRST YIELD TYPICAL BLAST PANEL CHARACTERISTICS & PROPERTIES PROPERTY Ultimate tensile strength in primary fiber direction, psi PERMANENT ROTATION MAXIMUM ROTATION INTERNAL STRAIN ENERGY ASTM METHOD SUPPORT ROTATION, θ TYPICAL TEST VALUE D ,400 psi (575 MPa) (4.17 kip/in. width) Pressure, (psi) Pressure Impulse DESIGN VALUE 66,720 psi (460 MPa) (3.3 kip/in. width) Elongation at break D % 1.76% Tensile Modulus, psi D x 10 6 psi (26.1 GPa) Typical Weight of Panel* Typical Dimensions* Design Pressures and Impulses 3.03 x 10 6 psi (20.9 GPa) 1,500 to 4,000 lbs. ( to kg) 10 ft. x 12 ft. (3.05M x 3.66M) 5 psi to 30 psi / 80 to 300 psi - msec Time, (msec) Impulse, (psi-ms) HOW TO USE TYFO Fibrwrap Blast Panels DESIGN The Tyfo Fibrwrap System shall be designed to meet specific design criteria. The criteria for each project is dictated by the engineer of record and any relevant building codes and/or guidelines. The design should be based on the allowable strain for each type of application and the design modulus of the material. The Fyfe Co. LLC engineering staff will provide preliminary design at no obligation. Test reports are available upon request. Fyfe Co. LLC Tyfo Fibrwrap Systems 8380 Miralani Drive, San Diego, CA Tel: Fax: [email protected] Statement of Responsibility: The technical information and application advice in this publication is based on the present state of our best scientific and practical knowledge. As the nature of the information herein is general, no assumption can be made as to the product s suitability for a particular use or application, and no warranty as to its accuracy, reliability or completeness, either expressed or implied, is given other than those required by State legislation. The owner, his representative or the contractor is responsible for checking the suitability of products for their intended use. Field service, where provided, does not constitute supervisory responsibility. Suggestions made by the Fyfe Co., either verbally or in writing, may be followed, modified or rejected by the owner, engineer or contractor since they, and not the Fyfe Co., are responsible for carrying out procedure appropriate to a specific application. 1/11 Fibrwrap Blast Panels Tyfo Systems are patented in U.S.A., Canada, and other countries. Copyright Fyfe Co. LLC 6-11
3 TYFO BLAST panels Tyfo Blast Panel Systems are manufactured by Fyfe Co LLC. These blast resistance wall systems are comprised of steel studs sheathed with a thin cementitious wall reinforced with Tyfo Blast Glass and have typical wall thicknesses and weight. Shock tube testing has proven the system s ability to resist pressures up to 30 psi at an impulse of 135 psi-ms. This is equivalent to 750 Ibs. of TNT at 83 ft. After three consecutive tests, the permanent deformation was only 1-1/8 inch. They are easily constructed using conventional construction methods. The wall assembly can be easily finished with any type of material such as brick or stone. Tyfo Blast Panels are easy to install and can be finished with any type of material Tested in a shock tube, the blast-resistance wall system survived high pressures with limited deformations exhibited Interior of shock tube showing driver and expansion sections The blast-resistance capabilities of the prefabricated blast-resistant wall systems can be evaluated using pressure-impulse diagrams Also available - Prefabricated, Field Prefabricated or Super Concrete (Tyfocrete ), block and brick walls reinforced with Tyfo Fibrwrap.
4 TYFO BLAST panel MODELING The composite steel stud wall designs were analyzed based on a nonlinear dynamic Single-Degree-of-Freedom (SDOF) analytical methodology. The key output from the SDOF analysis is the peak dynamic deflection of the structural component. For most flexural components, it is convenient to convert this value into a support rotation, θ, by assuming a center-hinge deformed shape as is typically observed in plastic systems, and then applying simple geometric relationships. Using the dynamic enhanced material properties of the steel studs and concrete, a moment-curvature plot was produced to determine the moment capacity and stiffness of the wall panels. From this, the SDOF model parameters were calculated using one-way beam methods described in UFC These experimental results allow us to analytically predict the response of various shapes and sizes of wall design for our clients prior to committing to full-size testing. Equivalent Spring-Mass SDOF System Experimental vs Analytical Displacement Calculation of Support Rotation from Peak Deflection
5 FEDERAL AVIATION ADMINISTRATION (FAA) AIR TRAFFIC CONTROL TOWER (ATCT) Tyfo Blast Panels were utilized as a prefabricated energy absorbing exterior wall building system. The wall system was designed dynamically to resist the total blast overpressure. The wall system s dynamic design also considered the pressure/time function (impulse). The project required large-scale proof testing on a calibrated blast shock tube at pressures greater than 20 psi with an associated minimum impulse of 120 psi-msec. The blast panel size and shape were configured to meet project geometry requirements.
6 Mission Statement The mission of Fyfe Company is to provide state-of-the-art solutions for today s structural problems. Fyfe Company provides innovative construction products and personalized technical support to meet the needs of engineers, contractors and owners in the most efficient and cost-effective manner. Fyfe Company is committed to developing long-term relationships with our customers by providing the best possible technical assistance and delivering the most professional, up-to-date solutions through continuous research and innovation. For additional information, design assistance or questions about a potential project, please contact us... Fyfe Co. LLC Tyfo Fibrwrap Systems 8380 Miralani Drive, San Diego, CA Tel: Fax: [email protected] Fyfe Asia Pte. Ltd. 24 Sin Ming Lane, # Midview City Singapore Tel: Fax: [email protected] Fyfe LatinAmerica Calle Los Bambues No. 16 Col. San Francisco San Salvador, El Salvador, C.A. Tel: Fax: Cell: [email protected] Fyfe (India) Pvt. Ltd. 226 Hammersmith Industrial Estate Narayan Pathare Marg Mahim (West), Mumbai India Tel: Fax: Cell: [email protected] Fyfe Europe S.A. 51 Ithakis Street & Kordeliou Glyfada, Athens, Greece Tel: Fax: [email protected] Contact Fyfe Europe S.A. for Europe, the Middle Eastern, the Russian Federation, and North Africa Fyfe (China) Pte. Ltd. Chengdu City 1st Ring Road East Section 5 No. 108 Dong Heng International No. 2 Bldg. Area 1 Unit People s Republic of China Tel: Fax: [email protected] Fyfe Asia Pte. Ltd. (Shanghai Representative Office) No. 885 Renmin Road Unit 613 Huai Hai China Tower Huangpu District Shanghai China Tel: Fax: [email protected] Fyfe Korea Co. Ltd. #428-5, Songnae-dong, Kangdong-gu Seoul, , Korea Tel: Fax: [email protected] Fyfe (Hong Kong) Ltd. Unit 5, 22/F Metropole Square 2 on Yiu Street Shatin Hong Kong S.A.R. Tel: Fax: [email protected] Representatives available in over 50 countries around the world Patented in U.S.A., Canada, and other countries. Copyright 2011 Fyfe Co. LLC Reproduction by written permission from Fyfe Co. LLC only. All rights reserved. Tyfo and Fibrwrap are registered trademarks for the products of Fyfe Co. LLC
PCI Design Handbook: Appendix A: Blast-resistant design of precast, prestressed concrete components
PCI Committee Report This report comprises Appendix A of the forthcoming 8 th edition of the PCI Design Handbook. The report has been approved by the PCI Blast Resistance and Structural Integrity Committee
APE T CFRP Aslan 500
Carbon Fiber Reinforced Polymer (CFRP) Tape is used for structural strengthening of concrete, masonry or timber elements using the technique known as Near Surface Mount or NSM strengthening. Use of CFRP
AST M F 1642-04/GSA TS01 T EST R EPO R T. Rendered to: UNI T E D ST A T ES A L U M INU M
AST M F 1642-04/GSA TS01 T EST R EPO R T Rendered to: UNI T E D ST A T ES A L U M INU M SE RI ES/M O D E L : B W3250 PR O DU C T T YPE : Aluminum Combination Fixed Window Summary of Results Title Test
The Original Carbon Fiber Reinforced Polymer System
Infrastructure The Original Carbon Fiber Reinforced Polymer System Phone: 52.292.39 Toll Free: 866.38.269 Fax: 52.48.5274 282 E. Fort Lowell Rd. Tucson, AZ 8576 www.dowaksausa.com Test results are supported
In-situ Load Testing to Evaluate New Repair Techniques
In-situ Load Testing to Evaluate New Repair Techniques W.J. Gold 1 and A. Nanni 2 1 Assistant Research Engineer, Univ. of Missouri Rolla, Dept. of Civil Engineering 2 V&M Jones Professor, Univ. of Missouri
Blast Resistant Building BP Refinery Rotterdam
Blast Resistant Building BP Refinery Rotterdam 14 May, 2008 1 1 Contents Presentation Introduction KCI Functional Specification Blast Resistant Building Basis for design Blast & impact loading Design modeling
COMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
SEISMIC UPGRADE OF OAK STREET BRIDGE WITH GFRP
13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 3279 SEISMIC UPGRADE OF OAK STREET BRIDGE WITH GFRP Yuming DING 1, Bruce HAMERSLEY 2 SUMMARY Vancouver
Technical Notes 3B - Brick Masonry Section Properties May 1993
Technical Notes 3B - Brick Masonry Section Properties May 1993 Abstract: This Technical Notes is a design aid for the Building Code Requirements for Masonry Structures (ACI 530/ASCE 5/TMS 402-92) and Specifications
DESIGN OF BLAST RESISTANT BUILDINGS IN AN LNG PROCESSING PLANT
DESIGN OF BLAST RESISTANT BUILDINGS IN AN LNG PROCESSING PLANT Troy Oliver 1, Mark Rea 2 ABSTRACT: This paper provides an overview of the work undertaken in the design of multiple buildings for one of
Incorporating Innovative Materials for Seismic Resilient Bridge Columns
Incorporating Innovative Materials for Seismic Resilient Bridge Columns WSDOT Including Contributions from: Dr. M. Saiid Saiidi University Nevada, Reno Brain Nakashoji University Nevada, Reno Presentation
Retrofitting By Means Of Post Tensioning. Khaled Nahlawi 1
Retrofitting By Means Of Post Tensioning Khaled Nahlawi 1 Abstract An analytical program was prepared to retrofit the Holy Cross Church in Santa Cruz, California. An inelastic analysis was perfonned on
Lymon C. Reese & Associates LCR&A Consulting Services Tests of Piles Under Axial Load
Lymon C. Reese & Associates LCR&A Consulting Services Tests of Piles Under Axial Load Nature of Services The company has a long history of performance of tests of piles and pile groups under a variety
SBEDS. 31st DOD Explosives Safety Seminar. (Single degree of freedom Blast Effects Design Spreadsheets ) San Antonio, Texas 24-26 August 2004
31st DOD Explosives Safety Seminar San Antonio, Texas 24-26 August 2004 SBEDS (Single degree of freedom Blast Effects Spreadsheets ) Dale Nebuda, P.E. U.S. Army Corps of Engineers Chuck Oswald, Ph.D.,
SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 *
SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 * PRODUCT: Polymer (Foam-Filled) Fuel Cells 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards
PERFORMANCE TEST REPORT. Rendered to: FORMTECH ENTERPRISES, INC. SERIES/MODEL: Truline PRODUCT TYPE: PVC Seawall
PERFORMANCE TEST REPORT Rendered to: FORMTECH ENTERPRISES, INC. SERIES/MODEL: Truline PRODUCT TYPE: PVC Seawall Report No.: Test Dates: 04/17/12 Through: 04/18/12 Report Date: 06/13/12 130 Derry Court
Series 4000 Fiberglass Pipe and Fittings
Series 4000 Fiberglass Pipe and Fittings for corrosive industrial service Uses and applications Listings Performance Acid drains Chemical process piping Corrosive slurries Food processing Geothermal Nonoxidizing
beams columns blast walls slabs pipes protective coatings polymer concrete Solutions Looking for Problems...
beams columns blast walls slabs pipes protective coatings polymer concrete Solutions Looking for Problems... CarbonWrap Solutions Services Turnkey Innovative Solutions and Products CarbonWrap Solutions,
SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:
Reading Assignment SLAB DESIGN Chapter 9 of Text and, Chapter 13 of ACI318-02 Introduction ACI318 Code provides two design procedures for slab systems: 13.6.1 Direct Design Method (DDM) For slab systems
SECTION 5 ANALYSIS OF CONTINUOUS SPANS DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE LEAD AUTHOR: BRYAN ALLRED
SECTION 5 ANALYSIS OF CONTINUOUS SPANS DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE LEAD AUTHOR: BRYAN ALLRED NOTE: MOMENT DIAGRAM CONVENTION In PT design, it is preferable to draw moment diagrams
Foam Injection Molding:
Foam Injection Molding: Unique Process Solutions for Light Weighting Automotive Plastic Parts Steve Braig President & CEO Trexel, Inc. AGENDA Technology Overview > Chemical Foaming > Physical Foaming Foamed
Simulation for the Collapse of WTC after Aeroplane Impact
Simulation for the Collapse of WTC after Aeroplane Impact LU Xinzheng & JIANG Jianjing Department of Civil Engineering, Tsinghua University, Beijing, 100084 Abstract: Mechanical simulation and parameter
Blast Proof Occupied Buildings
Blast Proof Occupied Buildings 1 1 Contents Presentation References Functional Specification Blast Resistant Building Basis for design Blast & impact loading Design modeling & analyses Preliminary design
Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.
Lab 3 Tension Test Objectives Concepts Background Experimental Procedure Report Requirements Discussion Objectives Experimentally determine the yield strength, tensile strength, and modules of elasticity
DESIGN OF PRESTRESSED BARRIER CABLE SYSTEMS
8601 North Black Canyon Highway Suite 103 Phoenix, AZ 8501 For Professionals Engaged in Post-Tensioning Design Issue 14 December 004 DESIGN OF PRESTRESSED BARRIER CABLE SYSTEMS by James D. Rogers 1 1.0
Reinforced Concrete Slab Design Using the Empirical Method
Reinforced Concrete Slab Design Using the Empirical Method BridgeSight Solutions for the AASHTO LRFD Bridge Design Specifications BridgeSight Software TM Creators of effective and reliable solutions for
/ / WORLDWIDE HEADQUARTERS NORTH AMERICA W. R. Grace & Co. Conn. 62 Whittemore Avenue Cambridge, MA 02140-1692 USA Tel. 617-876-1400 Fax 617-498-2643 Grace supplies products to more than 120 countries
Analysis of Steel Moment Frames subjected to Vehicle Impact
APCOM & ISCM 11-14 th December, 2013, Singapore Analysis of Steel Moment Frames subjected to Vehicle Impact Hyungoo Kang¹, Jeongil Shin 1, Jinkoo Kim 2 * 1 Graduate Student, Department of Civil-Architectural
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use
Stress Strain Relationships
Stress Strain Relationships Tensile Testing One basic ingredient in the study of the mechanics of deformable bodies is the resistive properties of materials. These properties relate the stresses to the
Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: [email protected]. The Passive Fire Protection Specialists
Enclosures Sturdy single and double wall fire protection construction Impact resistant Fast & easy installation Pre-manufactured and modular Available in galvanized, stainless steel & other specialty metals
The following are just a few of the advantages that Techno-Solis offers you as a solar contractor: Contact Us!
Techno-Solis Solar Pool Heaters The Techno-Solis collector is the most durable solar panel on the market today. In production since 1976, our panels have been installed by Authorized Techno-Solis Dealers
SMIP05 Seminar Proceedings VISUALIZATION OF NONLINEAR SEISMIC BEHAVIOR OF THE INTERSTATE 5/14 NORTH CONNECTOR BRIDGE. Robert K.
VISUALIZATION OF NONLINEAR SEISMIC BEHAVIOR OF THE INTERSTATE 5/14 NORTH CONNECTOR BRIDGE Robert K. Dowell Department of Civil and Environmental Engineering San Diego State University Abstract This paper
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER
Structural Foundation System
Structural Foundation System SLABTEK, a technological advancement in foundation designs for residential and lightweight commercial structures SlabTek is a patent allowed process for concrete foundations
External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902
External Wrapping of Steel Riser Pipe Case Study HJ3 CS200902 Introduction Refineries process a wide variety of petroleum products. As part of the process, they rely on cooling towers, which recycle water
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES 1 PART 1 - GENERAL 1.0 GENERAL 1.1 REFERENCES: SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED FIBERGLASS
RELAYS Solar Energy Systems
RELAYS Solar Energy Systems FUJITSU COMPONENTS CONTENTS Fujitsu relays for solar applications DC voltage versions - AC voltage versions - Latching versions RELAY PRODUCT LINE UP - SOLAR ENERGY SYSTEMS
Outline MICROPILES SUBJECT TO LATERAL LOADING. Dr. Jesús Gómez, P.E.
MICROPILES SUBJECT TO LATERAL LOADING Dr. Jesús Gómez, P.E. Micropile Design and Construction Seminar Las Vegas, NV April 3-4, 2008 Outline When are micropiles subject to lateral load? How do we analyze
Green Thread Product Data
Green Thread Product Data Applications Dilute Acids Caustics Produced Water Industrial Waste Hot Water Condensate Return Materials and Construction All pipe manufactured by filament winding process using
Pavement Thickness. esign and RCC-Pave Software. Roller-Compacted Concrete Pavement: Design and Construction. October 24, 2006 Atlanta, Georgia
Roller-Compacted Concrete Pavement: Design and Construction Pavement Thickness esign and RCC-Pave Software Gregory E. Halsted, P.E. Pavements Engineer Portland Cement Association October 24, 2006 Atlanta,
Physical Dry Conditioned Unit Test method
Technical Data Sheet Ixef 1022 Ixef 1022 is a 50% glass-fiber reinforced, general purpose compound that exhibits very high strength and rigidity, outstanding surface gloss, and excellent creep resistance.
International Journal of Engineering Research-Online A Peer Reviewed International Journal Articles available online http://www.ijoer.
RESEARCH ARTICLE ISSN: 2321-7758 DESIGN AND DEVELOPMENT OF A DYNAMOMETER FOR MEASURING THRUST AND TORQUE IN DRILLING APPLICATION SREEJITH C 1,MANU RAJ K R 2 1 PG Scholar, M.Tech Machine Design, Nehru College
US General Services Administration Standard Test Method for Glazing and Window Systems Subject to Dynamic Overpressure Loadings
US General Services Administration Standard Test Method for Glazing and Window Systems Subject to Dynamic Overpressure Loadings 1. Introduction 4. Terms and Definitions This test standard is intended to
Long term performance of polymers
1.0 Introduction Long term performance of polymers Polymer materials exhibit time dependent behavior. The stress and strain induced when a load is applied are a function of time. In the most general form
How To Design A Post Tensioned Deck For A Building
SAMUEL ÁVILA STRUCTURAL OPTION FACULTY CONSULTANT: THOMAS BOOTHBY UNIVERSITY OF CENTRAL FLORIDA S ACADEMIC VILLAGES ORLANDO, FL THESIS PROPOSAL EXECUTIVE SUMMARY DECEMBER 12, 2005 Introduction: The University
SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS
Fracture Mechanics of Concrete Structures Proceedings FRAMCOS-3 AEDIFICA TIO Publishers, D-79104 Freiburg, Germany SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS H.
In-Line Fluid Monitoring Packages
In-Line Fluid Monitoring Packages Informer TM & ProControl TM 1KE PROVEN QUALITY. LEADING TECHNOLOGY. The Affordable Way to Measure Fluids & Reduce Paint Waste The InformerTM and ProControlTM 1KE are easy-to-use
Optimum proportions for the design of suspension bridge
Journal of Civil Engineering (IEB), 34 (1) (26) 1-14 Optimum proportions for the design of suspension bridge Tanvir Manzur and Alamgir Habib Department of Civil Engineering Bangladesh University of Engineering
DuPont Kapton HN. polyimide film
DuPont Kapton HN polyimide film Technical Data Sheet DuPont Kapton HN general-purpose film has been used successfully in applications at temperatures as low as -269 C (-452 F) and as high as 400 C (752
Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick
Photo courtesy of Delta Stone, Heber City, UT Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick THIN VENEER INSTALLATION SYSTEMS PREMIUM BONDING MORTARS Premium PCL Stone
Assistant Professor of Civil Engineering, University of Texas at Arlington
FRC Performance Comparison: Direct Tensile Test, Beam Type Bending Test, and Round Panel Test Shih Ho Chao (Presenting Author) Assistant Professor of Civil Engineering, University of Texas at Arlington
LAYING BLOCK AND BRICK
LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct
Seismic Risk Prioritization of RC Public Buildings
Seismic Risk Prioritization of RC Public Buildings In Turkey H. Sucuoğlu & A. Yakut Middle East Technical University, Ankara, Turkey J. Kubin & A. Özmen Prota Inc, Ankara, Turkey SUMMARY Over the past
CelCulture. CelCulture CO2 Incubator Model CCL-170_-_. CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications
1 CO2 Incubator Model CCL-170_-_ CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications Welcome to Esco Esco s Vision is to provide enabling technologies for scientific
Formwork for Concrete
UNIVERSITY OF WASHINGTON DEPARTMENT OF CONSTRUCTION MANAGEMENT CM 420 TEMPORARY STRUCTURES Winter Quarter 2007 Professor Kamran M. Nemati Formwork for Concrete Horizontal Formwork Design and Formwork Design
Connection Solutions
Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction
Foam Firmness Measurements IFD For Most Furniture And Bedding Applications
INTOUCH is a regular publication of the Polyurethane Foam Association. It covers topics of interest to users of flexible polyurethane foam and is designed as a quick reference e for background information
DELRIN HYTREL MINLON RYNITE
ddupont Engineering Polymers Design Check Chart DELRIN HYTREL MINLON RYNITE ZYTEL DELRIN HYTREL MINLON RYNITE ZYTEL DELRIN HYTREL MINLON RYNITE ZYTEL DELRIN HYTREL MINLON RYNITE ZYTEL DELRIN HYTREL MINLON
5 G R A TINGS ENGINEERING DESIGN MANUAL. MBG Metal Bar Grating METAL BAR GRATING MANUAL MBG 534-12 METAL BAR GRATING NAAMM
METAL BAR NAAMM GRATNG MANUAL MBG 534-12 5 G R A TNG NAAMM MBG 534-12 November 4, 2012 METAL BAR GRATNG ENGNEERNG DEGN MANUAL NAAMM MBG 534-12 November 4, 2012 5 G R A TNG MBG Metal Bar Grating A Division
Amendment 1 Preliminary Engineering Report for the City of Salida
Amendment 1 Preliminary Engineering Report for the City of Salida Galleries Water Tank Rehabilitation Project February 11, 2010 Prepared by 1.0 Executive Summary The work of this Preliminary Engineering
SECTION 1 GENERAL REQUIREMENTS
Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,
ETABS. Integrated Building Design Software. Concrete Shear Wall Design Manual. Computers and Structures, Inc. Berkeley, California, USA
ETABS Integrated Building Design Software Concrete Shear Wall Design Manual Computers and Structures, Inc. Berkeley, California, USA Version 8 January 2002 Copyright The computer program ETABS and all
Payroll Services Hong Kong
Payroll Services Hong Kong Gain peace of mind Leave your back office issues with us Tricor Business Services partners with you to enhance your competitiveness and generate business value. Our comprehensive
Chapter 8. Flexural Analysis of T-Beams
Chapter 8. Flexural Analysis of T-s 8.1. Reading Assignments Text Chapter 3.7; ACI 318, Section 8.10. 8.2. Occurrence and Configuration of T-s Common construction type.- used in conjunction with either
PAINT BOOTH LIGHTING
PAINT BOOTH LIGHTING PAINT BOOTH LIGHTING Lighting is comprised of many components that need to be considered when selecting the appropriate fixtures and lamps to accomplish a specific task. Selecting
Modern Techniques for Concrete Pavement Design
Modern Techniques for Concrete Pavement Design Robert Rodden, P.E. Director of Technical Services & Product Development American Concrete Pavement Association km of Paved Roadway by Country 5.000.000 4.500.000
Thin Whitetopping Application at Williamsburg Regional Airport and Other Thin Whitetopping Airport Applications.
Thin Whitetopping Application at Williamsburg Regional Airport and Other Thin Whitetopping Airport Applications. Author: Gary L. Mitchell, P.E. Director Airports, American Concrete Pavement Association
BEIJING SHANGHAI HONG KONG
BEIJING SHANGHAI HONG KONG BEIJING - SHANGHAI - HONG KONG ASIAN PRACTICE Chiomenti Studio Legale is an international law firm present in China, with offices in BEIJING, Shanghai and Hong Kong. Expansion
Concrete Design Manual
The Reinforced Concrete Design Manual In Accordance with ACI 318-11 SP-17(11) Vol 2 ACI SP-17(11) Volume 2 THE REINFORCED CONCRETE DESIGN MANUAL in Accordance with ACI 318-11 Anchoring to concrete Publication:
TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION
TECHNICAL NOTE On Cold-Formed Steel Construction 1201 15th Street, NW, Suite 320 W ashington, DC 20005 (202) 785-2022 $5.00 Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006
ZBuilder Ultra. Delivers the capabilities of a highend rapid prototyping system at a fraction of the cost. 2010 Z Corporation 2
2010 Z Corporation ZBuilder Ultra Accurate, High-Resolution Plastic Prototypes Delivers the capabilities of a highend rapid prototyping system at a fraction of the cost 2010 Z Corporation 2 ZBuilder Ultra
SR Door co-ordinators
SR Door co-ordinators DORMA SR 390 DORMA SR 392 Door co-ordinators DORMA SR 390 door co-ordinator, surface-installed 40 70 Active leaf (2nd closing) The DORMA SR 390 is a thoroughly proven, purely mechanical
Amodel AS-1133 HS. polyphthalamide. Technical Data Sheet
Technical Data Sheet Amodel AS-1133 HS Amodel AS-1133 HS is a 33% glass reinforced, heat stabilized (PPA) resin that provides excellent structural integrity in molded parts, even those with wall thicknesses
Chapter 5 Bridge Deck Slabs. Bridge Engineering 1
Chapter 5 Bridge Deck Slabs Bridge Engineering 1 Basic types of bridge decks In-situ reinforced concrete deck- (most common type) Pre-cast concrete deck (minimize the use of local labor) Open steel grid
Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick ARCHITECTURAL SPECIFICATIONS / CAD MODELS TVISTM WARRANTIES
ARCHITECTURAL SPECIFICATIONS / CAD MODELS With more than 40 years of manufacturing high quality, innovative building products in the commercial and residential markets, Custom Building Products TVISTM
CRASH ANALYSIS OF AN IMPACT ATTENUATOR FOR RACING CAR IN SANDWICH MATERIAL
F2008-SC-016 CRASH ANALYSIS OF AN IMPACT ATTENUATOR FOR RACING CAR IN SANDWICH MATERIAL Boria, Simonetta *, Forasassi, Giuseppe Department of Mechanical, Nuclear and Production Engineering, University
Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,
Volume, Special Issue, ICSTSD Behaviour of Steel Bracing as a Global Retrofitting Technique Miss S. S. Nibhorkar M. E (Structure) Scholar, Civil Engineering Department, G. H. Raisoni College of Engineering
METU DEPARTMENT OF METALLURGICAL AND MATERIALS ENGINEERING
METU DEPARTMENT OF METALLURGICAL AND MATERIALS ENGINEERING Met E 206 MATERIALS LABORATORY EXPERIMENT 1 Prof. Dr. Rıza GÜRBÜZ Res. Assist. Gül ÇEVİK (Room: B-306) INTRODUCTION TENSION TEST Mechanical testing
METHOD OF STATEMENT FOR STATIC LOADING TEST
Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents
SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM
SLAM-SHUT VALVE Type OSE Process Management TM DESCRIPTION The purpose of the OSE slam shut valve is to totally and rapidly cut off gas flow when the outlet pressure exceeds or drops below the setting.
Matrix system with enhanced mechanical performance: new infusion system for wind energy applications enables lighter, longer, lower cost rotor blades
White Paper Matrix system with enhanced mechanical performance: new infusion system for wind energy applications enables lighter, longer, lower cost rotor blades Malte Wichmann Momentive Specialty Chemicals
SILASTIC 9161 RTV Silicone Elastomer
Product Information SILASTIC 9161 RTV Silicone Elastomer FEATURES Room temperature cure Usable at temperatures from -50 C to +250 C Excellent dielectric properties Highly resistant to moisture, oxidation
Introduction...COMB-2 Design Considerations and Examples...COMB-3
SECTION DIRECTORY General Information Introduction...COMB-2 Design Considerations and Examples...COMB-3 Combination Assembly Recommendations and Limitations Composite Configurations...COMB-4 Typical Sealant
DEVELOPMENT OF A NEW TEST FOR DETERMINATION OF TENSILE STRENGTH OF CONCRETE BLOCKS
1 th Canadian Masonry Symposium Vancouver, British Columbia, June -5, 013 DEVELOPMENT OF A NEW TEST FOR DETERMINATION OF TENSILE STRENGTH OF CONCRETE BLOCKS Vladimir G. Haach 1, Graça Vasconcelos and Paulo
MATERIAL SUBMISSION GUIDELINES & FORM
MATERIAL SUBMISSION GUIDELINES & FORM Material submissions are reviewed on a monthly basis by our New York City headquarters. The information you provide will be used to write a description of your material.
09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec 03500 Master Spec. 03 49 00 Page 1
C. S. I. Spec 03500 Page 1 PART 1 - GENERAL 1.01 SUMMARY:.01 Provide special glassfiber reinforced cement (GRC) shapes in accordance with the requirements of the contract documents..02 The installing contractor
HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars
Report on Wind Resistance of Signs supported by Glass Fiber Reinforced Concrete (GFRC) Pillars Prepared for US Sign and Fabrication Corporation January, 2006 SUMMARY This study found the attachment of
Performance of Existing Reinforced Concrete Columns under Bidirectional Shear & Axial Loading
Performance of Existing Reinforced Concrete Columns under Bidirectional Shear & Axial Loading Laura M. Flores University of California, San Diego REU Institution: University of California, Berkeley REU
DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1
Building Science Bulletin DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1 and IECC Air Leakage Requirements When Tested in Accordance with ASTM E2357
s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In
Family GUIDE FOR RESIDENTIAL applications Foamular Where quality and performance make a home The OWENS CORNING FOAMULAR XPS INSULATION FAMILY ALBUM is a critical feature of any home impacting overall comfort
Software Tax Characterization Helpdesk Quarterly June 2008
& McKenzie Software Tax Characterization Helpdesk Quarterly June 2008 Characterizing foreign software revenues is a complex challenge for large and small software firms alike. Variations in the rules around
DIGITAL DISPLACEMENT RISING STEP LOAD LRA/RSL TEST EQUIPMENT
DIGITAL DISPLACEMENT RISING STEP LOAD LRA/RSL TEST EQUIPMENT BACKGROUND AND PRODUCT DESCRIPTIONS Fracture Diagnostics provides state-of-the-art test equipment, utilizing the Rising Step Load testing technique.
4B-2. 2. The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.
Shear Walls Buildings that use shear walls as the lateral force-resisting system can be designed to provide a safe, serviceable, and economical solution for wind and earthquake resistance. Shear walls
Native InDesign 2890 SaniTite Brochure 1/8" 100 300 CMYK April 17, 07
Sanitary Sewer Pipe Tough pipe for a tough environment SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling, toughness