3M ESD Pro ESD Event Indicator CTM082. User s Guide

Similar documents
3M Wrist Strap and Footwear Tester 740. User s Guide

CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok

Wireless Indoor/ Outdoor Thermometer

Nokia Bluetooth Headset BH /1

Alarm Clock USER GUIDE

Nokia Bluetooth Headset BH-800 User Guide Issue 2

Nokia Bluetooth Headset BH /2

Nokia Bluetooth Headset BH-101. Issue 1

Nokia Bluetooth Headset BH-200 User Guide

Nokia Bluetooth Headset BH-104

62 Max/62 Max + Infrared Thermometer

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Nokia Bluetooth Headset BH-607. Issue 2. 1

Dynatel Advanced Modular System 965AMS 30-Megahertz Spectrum Analyzer

User Guide for the Wireless Headset (HS-11W) Issue 1

Nokia Bluetooth Headset BH-109

Pocket Tach 99 (PT99) Non-Contact Tachometer

Nokia Bluetooth Headset BH-102. Issue 1

Nokia Bluetooth Headset BH /1

Temperature Humidity Meter

Architect/Contractor Information Package

Nokia Wireless Keyboard (SU-8W) User Guide

Nokia Bluetooth Headset BH /2

WTSL-SN-1 Alarm Control Unit with Wi-Safe 2 Installation and User Guide

HVAC Clamp Meter. Users Manual

2-Way Wireless Indoor Siren Installation Guide

Wireless Alarm System. Wireless Keypad. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

Original instructions Tina 3A/Aps Adaptor unit

IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS. For use with a Power Wheels vehicle that requires a 12-Volt 9.5 Amp/Hr lead acid battery.

Owner s Manual & Safety Instructions

Tina 2A/B Adaptor unit

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

3M Stats and Status Software for 3M Detection System Model 8900/9900. Staff Guide

G1 GPS Sensor User Manual

Alarm Clock USER GUIDE

Dynatel 2273 Advanced Cable and Fault Locator

Nokia Bluetooth Headset BH-118 User Guide

3M Dynatel Triple Play Customer Service Test Set INS970

CONTOURROAM USER MANUAL

323/324/325. Calibration Manual. Clamp Meter

Passive Infrared Sensor Alarm

VARIO PROX CARD READER INSTALLATION MANUAL

Nokia USB Modem. Issue 1.1

INSTALLATION AND OPERATING INSTRUCTIONS

Powerware Relay-Serial Card User s Guide

Owner s Manual & Safety Instructions

Output Filter Design for EMI Rejection of the AAT5101 Class D Audio Amplifier

Hand Held Metal Detector

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

Weather Radio Alarm Clock

FM-CI Cochlear Implant Adaptor Instructions for Use

ENGLISH USER S MANUAL. compact handheld 1D/2D code scanner

Sip/Puff Switch User Guide

2GB MP3 Player USER GUIDE

Manual Ranging MultiMeter

InHome Water Leak Detection Package

NFC Communication Tray Model: HHX-IT3-Z

PrintPAD CN3/4/3e/4e. User Guide

Detection System Model 500 Series Owner s Manual

PM1109 Mondo QUICK GUIDE

BroadBand PowerShield. User Manual

How To Service A Paper Shredder

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

TABLE OF CONTENTS 11.0 WARRANTY

Safety Notices 安 全 通 知 和 标 签. Securite, Consignes et etiquettes. P/ACE MDQ plus Capillary Electrophoresis System

IN-OUT Thermometer with Cable Free Sensor and Clock

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

AM/FM PLL Clock/Table Radio

WARNING: This product contains chemicals known to the state of California to cause cancer, or birth defects or other reproductive harm.

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000

Table of Contents WARNING SYMBOLS AND DEFINITIONS

Ultrasonic Distance Meter. Operation Manual

Nokia Bluetooth Headset BH-110 User Guide

Digital Fingerprint safe

How to connect your D200 using Bluetooth. How to connect your D200 using GPRS (SIM Card)

Periodic Verification System Model 775PVS

Model Owner s Manual. Español - P. 19 Français - P. 39

User Manual (English)

Thermometer model 00754

3M Quick Connect System (QCS) 2810 Models 2810A and 2810B

el-720 Carbon Dioxide Gas Leak Detector User s Guide

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

User Guide Microsoft Screen Sharing for Lumia Phones (HD-10)

Installation guide H A. HSI hardwired system interface

VERIFICATION OF ESD ENVIRONMENT IN PRODUCTION PHILOSOPHY, METHODOLOGY AND TOOLS

Installation Instructions

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

AXIS T81B22 DC 30W Midspan

Trilogy DL2700 Programming Instructions OI209A 2/04

Installing Your MS Access Database (Manual Installation Instructions)

Nokia Bluetooth Headset BH-604 User Guide

Remote Alarm Monitoring System

EzFlex Combustible Gas Leak Detector Model EZ40

Instructions A Amp AC/DC Current Probe

safe, smart, protected

Touchless Forehead Thermometer

Smile 11 AS-i Emergency stop with safe AS-i input node

Bounce & Spin ZebraTM

Transcription:

3M ESD Pro ESD Event Indicator CTM082 User s Guide

Table of Contents Section Page Safety Information...3 Event Counter...4 CDM Mode...4 Operation...5 Brief Tour...6 Controls and Indicators...6 General Information...7 Warranty...9 2

Safety Information Please read, understand, and follow all safety information contained in these instructions prior to the use of this device. Retain these instructions for future reference. Explanation of Signal Word Consequences WARNING CAUTION NOTICE Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury and/or property damage. Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury and/or property damage. Indicates a potentially hazardous situation, which, if not avoided, may result in property damage. WARNING To reduce the risks associated with environmental contamination: When working with the automated equipment, always observe safety precautions as recommended by equipment manufacturer and your company s practices. CAUTION To reduce the risks associated with environmental contamination: Dispose of the monitor in accordance with local, state, and federal regulations. NOTICE To reduce the risks associated with property damage: Periodically check that the indicator is functioning properly. 3

The 3M ESD Pro ESD Event Indicator CTM082 is an easy-to-use handheld device that is designed to detect and count ESD events that can damage sensitive components and cause tool lockups, erratic behavior and parametric errors. Event Counter A four-digit display counts the number of events equal to or exceeding the threshold. To reset the counter, press the actuator of the Set side switch inwards. The counter is also reset when the power is turned off. CDM Mode In a typical industrial environment there are many sources that produce signals similar to those of ESD events. Such signals may include relays, solenoids, stepper motors or similar devices. In order to separate ESD events from nonrelated EMI (electromagnetic interference) events, the ESD Pro ESD Event Indicator CTM082 employs a filter that separates waveforms of the signals and rejects the ones that are different from a classic shape of an ESD event. First, try to use the ESD Pro ESD Event Indicator CTM082 with CDM filter switch turned off. This allows you to assess the complete environment. If you observe extraneous events, then the turn CDM filter switch on. The ESD Pro ESD Event Indicator CTM082 detects most ESD events by the specific electromagnetic signature these events produce.therefore, the performance of the ESD Pro ESD Event Indicator CTM082 must be looked at in view of wave propagation. Just like with a microphone, the farther away from the source of the signal you are, the weaker the signal will be. When searching for the sources of ESD events, it is advisable to get as close as is practical, considering necessary safety precautions, to the suspected sources. In a typical tool, such as an IC handler or a pick-and-place SMT machine, such sources of ESD events may include places of IC pick-up and IC placement on any conductive or even dissipative surface. When working with the automated equipment, always observe safety precations as recommended by equipment manufacturer and your company s practices. 4

Operation When the 3M ESD Pro ESD Event Indicator CTM082 is turned on, it is ready to detect, count and measure most ESD events. Bar Graph Display The 10-LED bar graph shows the relative strength of most ESD events. If an ESD event does not exceed the set alarm level, LEDs indicating its strength are green. Whenever the strength of an event exceeds the set threshold, LEDs turn red. Event strength is a factor of many variables: the accumulated static voltage the capacitance of the charged objects (a larger object holds more charge than a smaller one) the physical size of discharging objects the environment the distance from ESD event occurrence Therefore, one should exercise good judgement in comparing the strength of ESD events captured under different conditions. Threshold Adjustment The ESD Pro ESD Event Indicator CTM082 can detect ESD events in a wide dynamic range. For most applications, only the events that exceed certain strengths are of importance. Threshold setting in the ESD Pro ESD Event Indicator CTM082 is critical in identifying only ESD events of the strength equal or above the level of importance to you. Threshold setting is done by a small rotary/push switch on the right side of the ESD Pro ESD Event Indicator CTM082. Checking the Current Threshold Simply push the actuator of the switch inwards. One red LED will show the current ESD event threshold. Any event equal to or exceeding this level will produce a count and a beep, and the LED bar graph will show it in red. An event below this level will still be shown on the bar graph in green, but no count or sound will be produced. Setting the Threshold To set a new threshold, do not press the switch. Rather, move its actuator up or down. Once the switch begins to move, one red LED appears on the bar graph display. As the switch moves up and down, this red LED moves accordingly and its position indicates the new theshold level. 5

Saving the Threshold Level After the new threshold is set, release the switch actuator and then press it inwards. The new current threshold is now saved. The next time you power up your 3M ESD Pro ESD Event Indicator CTM082, this level will be automatically set. Brief Tour of your ESD Pro ESD Event Indicator CTM082 Please refer to the following pages of this User s Guide for a detailed explanation of each control, indicator and connection. Antenna Power Switch ESD Event Strength Bar Graph Sound Switch CDM Filter Switch Filter Indicator Alarm Threshold Adjustment / Reset Low-Battery Indicator Event Counter Battery Compartment (on the back) Controls and Indicators Power Switch: Turns power on and off Sound Switch: Turns the sound on and off CDM Filter Switch: Turns EMI-rejection mode on and off Alarm Threshold: Adjusts alarm threshold up and down. Displays current alarm threshold. Resets the Event Counter Event Counter: Counts ESD events above the set threshold ESD Event: Bar Graph Shows relative ESD event strength Filter Indicator: Shows that 3M ESD Pro ESD Event Indicator CTM082 is in filter mode (rejection of EMI most Events) Low Battery: Shows that the battery needs to be replaced 6

General Power 3M ESD Pro ESD Event Indicator CTM082 uses a 9V alkaline battery. Do not use any other type of battery. If you are not using your ESD Pro ESD Event Indicator CTM082 for an extended period of time, remove the battery from the unit in order to prevent damage caused by battery leakage. Installing the Battery Remove the battery door at the back of ESD Pro ESD Event Indicator CTM082 and attach the 9V battery to the battery clips. Observe the polarity of the battery. Re-install the battery door. Low-Battery Indicator When battery voltage gets low, the low battery indicator on the display appears. Turning ESD Pro ESD Event Indicator CTM082 On and Off Move the actuator of the power slide switch to the right. The ESD event counter should display a number of captured events, usually 0 at this point. The events counter is reset when the power is turned off. To turn the power off, move the actuator of power slide switch to the left. The ESD Pro ESD Event Indicator CTM082 has no automatic shut-off. Don t forget to turn it off when not in active use. Antenna In order for the ESD Pro ESD Event Indicator CTM082 to detect most ESD events, its antenna needs to be properly installed. Screw the antenna using only your fingers no tools since overtightening the connection may lead to damage to the instrument. Sound The ESD Pro ESD Event Indicator CTM082 can produce audible alarm when an event is deleted. In order to enable this function, move the actuator of sound slide switch to the right. 7

Customer and Technical Support For customer and technical support: within the US Contact: 3M Electronics Materials Solutions Division, Customer Service Department 866-722-3736 For customer service and technical support outside the US contact your local authorized 3M representative see the distributor section at www.3mstatic.com. 8

WEEE Statement The following information is only for EU-members States: The mark shown to the right is in compliance with Waste Electrical and Electronic Equipment Directive 2002/96/EC (WEEE). The mark indicates the requirement NOT to dispose the equipment as unsorted municipal waste, but use the return and collection systems according to local law. CE Statement Meets CE (European Confomity) requirements. 3M is a trademark of 3M Company. Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for one year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. 3 Electronics Materials Solutions Division Static Control Products 926 JR Industrial Drive Sanford, NC 27332-9733 Toll-Free: 866-722-3736 International: 919-718-0000 Email: 3mstaticinfo@mmm.com www.3mstatic.com Please recycle. Printed in USA. 3M 2014. All rights reserved. 78-9100-6154-4B JHA