3M Quick Connect System (QCS) 2810 Models 2810A and 2810B
|
|
|
- May Parrish
- 10 years ago
- Views:
Transcription
1 3M Quick Connect System (QCS) 2810 Models 2810A and 2810B Instructions October
2 Contents 1.0 General Recommended Installation Procedure for 3M Quick Connect Systems 2810A and 2810B Jumper Running Testing Accessories...7 2
3 1.0 General 1.1 The 3M Quick Connect System (QCS) 2810A cross-connect terminal block consists of the 10-pair 2810 terminal block with installed label holders for pair numbering, single pair jumper caps for hand termination of jumper wires on the front or jumper side of the block, and 5-pair covers for securing terminated feeder and distribution conductors on the back or cable side of the block. The block will accept 22 and 24 AWG plastic insulated jumper wire on the front or jumper side, and AWG plastic insulated conductors on the back or cable side. The 2810A system requires use of punchdown tool for cable side termination. 1.2 The 3M Quick Connect System (QCS) 2810B cross-connect terminal block consists of the 10-pair 2810 terminal block with installed label holders for pair numbering, single pair jumper caps for hand termination of jumper wires on the front or jumper side of the block, and single pair caps for hand termination of feeder and distribution conductors on the back or cable side of the block. The block will accept 22 and 24 AWG plastic insulated jumper wire on the front or jumper side, and AWG plastic insulated conductors on the back or cable side. 2.0 Recommended Installation Procedure for 2810A and 2810B Systems 2.1 Mount frames vertically to supports in cabinet or pedestal. Route feeder and distribution cables into the frames. Using tie wraps, secure cables to frame sides or back, fanning out binder groups above the frame positions where they will be terminated. Be sure to leave adequate length in binder groups to allow slack for possible future maintenance activities. Note: Depending on the specific installation (crossconnect cabinet, NID, etc.) the frame may be integrated into the application. 3
4 Using Frame: 3M Quick Connect System (QCS) 2810A Block on Frame 2.2 Mount the first block to the frame with the 5-pair covers facing out and oriented so the covers open down. 2.3 Fan wires into the block from above, leaving enough slack to allow future reentry to the cable side if necessary. Be sure wires extend at least 5 cm (2 in) past block to allow removal of cutoff wires after termination. 2.4 Use the 3M Punch-Down Tool 2810 or the standard tool 3M Punch-Down Tool SOR-OC to terminate cable conductors and cut off excess. See above for correct orientation and positioning of tool to ensure correct termination and cut-off. After terminating conductors and removing excess wire, close 5-pair covers, making sure they latch firmly to body. 2.5 Remove block from frame. Rotate block 180. backward and remount in same frame position with 1-pair jumper caps facing out. 3M logo on cap is in right-side up orientation. Push block firmly into place on frame. Cable pairs should now enter back side of the block from below. Repeat until all feeder and distribution blocks have been terminated and mounted to frame. Using Frame: 3M Quick Connect System (QCS) 2810B Block 2.6 Mount the first block to the frame with the label holders facing in and the single pair caps facing out and oriented so the caps open down. 4
5 2.7 Fan wires into the caps from above, leaving enough slack to allow future reentry to the cable side, if necessary. Open cable pair cap by pushing down on latch and rotating down. Cut cable wires to length. Insert cable wire ends A (tip) left and B (ring) right into the wire openings in cap, making sure they are inserted all the way to the back of the cap. 2.8 While holding the cable wires in place, close the cap and press to snap latch firmly into place 2.9 Terminate additional cable wires by repeating the above procedure Inspect wires for correct routing. Be sure caps are snapped firmly into place Remove block from frame. Rotate block 180 backward and remount in same frame position with 1-pair jumper caps facing out. 3M logo on cap is in right-side up orientation. Push block firmly into place on frame. Cable pairs should now enter back side of the block from below. Repeat until all feeder and distribution blocks have been terminated and mounted to frame. 3.0 Jumper Running 3.1 Open feeder pair jumper cap by pushing up on latch and rotating up. Insert jumper wire ends A (tip) left and B (ring) right into wire openings in cap, making sure they are inserted all the way to the back of the cap. 3.2 While holding the jumper wires in place, close the cap and press to snap latch firmly into place. 5
6 3.3 Route jumper wires to distribution pair through wire loops on block ends and through vertical and horizontal wireways. Cut jumper wires to appropriate length, leaving at least 5 cm (2 in) of slack. 3.4 Terminate the jumper wires to the distribution pair by repeating the procedure described in steps 3.1 and Terminate additional jumper wires by repeating the above procedure. 3.6 To remove jumper wires, open the cap and pull wires straight out from block. 4.0 Testing 4.1 Testing using the 3M Pair Test Probe To test, insert probe onto cap as shown. Black lead to the left and the red lead to the right.testing does not interrupt the circuit. 6
7 5.0 Accessories 5.1 Accessories include frames of various sizes for mounting in cabinets or pedestals; a pair test probe for testing pair circuits on installed blocks;priority caps for identification of special circuits; the 3M Punch-Down Tool 2810 and the standard tool 3M Punch-Down Tool SOR-OC for termination of feeder and distribution cable pairs on 3M Quick Connect System (QCS) 2810A Blocks. (Tools not needed for 3M Quick Connect System (QCS) 2810B Blocks.) Accessories Test Probes XL 2827P 2827PC Priority Caps 2810PC-R 2810PC-P Replacement Caps 2810RC-O 2810RC-P Label Holders 2810L 2810L-P Frame 2810F 7
8 3M is a trademark of 3M Company. All other trademarks are the property of their respective owners. Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. 3 Communication Markets Division 6801 River Place Blvd. Austin, TX Please Recycle. Printed in USA. 3M All Rights Reserved.
3M Quick Connect System (QCS) 2814
Communication Markets Division 3M Quick Connect System (QCS) 2814 Designed for your broadband network The 3M Quick Connect System 2814 is a terminal/cross-connect system featuring integrated protection
Expanding a 40-Type Cabinet
Expanding a 40-Type Cabinet using the 3M Add-On Terminal 4220P 400-Pair and Jumper Trough Instructions January 2006 Table of Contents 1.0 General... 3 2.0 Cabinet Overall Descriptions... 3 3.0 Tools Required...
Dynatel Advanced Modular System 965AMS 30-Megahertz Spectrum Analyzer
3 Dynatel Advanced Modular System 965AMS 30-Megahertz Spectrum Analyzer DSL User s Guide Future-Proof Testing Platform February 2009 78-8140-2658-5-A 2 3M Dynatel Advanced Modular System 965AMS 30-MHz
3M Integrated Splitter Block BRCP-SP
The Network of Networks 3M Integrated Splitter Block BRCP-SP The 3M Integrated Splitter Block BRCP-SP is the latest generation of the Cross Connect System BRCP developed by 3M specifically for xdsl and
3M xdsl Line Conditioners 3620
3M xdsl Line Conditioners 3620 Instructions 1.0 General 1.1 Document Purpose This document provides general and installation information necessary to install the 3M xdsl Line Conditioner. 1.2 Description
3M Dynatel Triple Play Customer Service Test Set INS970
3M Dynatel Triple Play Customer Service Test Set Advanced Diagnostics Software Options DELT, SELT and Spectral Analysis The Test Set has the ability to run advanced diagnostics in different scenarios to
3M Scotchcast Mine and Portable Cable Splice Kit 8096-4
3M Scotchcast Mine and Portable Cable Splice Kit 8096-4 Installation Instructions 1.0 Kit Contents: 2 Funnels 3 EPDM Rubber Cold Shrink Cold Shrink Insulator 1 Wrap-around Mold Assemblies 2 Rubber Mold
3M Serial Attached SCSI (SAS) Connector Boardmount Compliant Pin and Surface Mount, Vertical Receptacle
M Serial Attached SCSI (SAS) Connector 6 Gbps input/output connector for backplane applications Two contact mating levels for early-mate and latebreak allows blind mating or hot swap applications Capable
3M Pin Strip Header 2 mm 2 mm Solder Tail Straight & Right Angle, Surface Mount Straight 1512 Series
M Pin Strip Header 2 2 Solder Tail Straight & Right Angle, Surface Mount Straight 1512 Series Mates with a variety of dual row 2 board mount and wire mount sockets High temperature insulator compatible
3M High Flex Life Cable.050" 28 AWG Stranded, PVC 3319 Series
M High Flex Life Cable.050" 28 AWG Stranded, PVC 19 Series Flex life of 100 million cycles at 1 /4 inch diameter 19 strands of high strength copper alloy provide the longest flex life available for dynamic
BIX Termination Blocks
Characteristics One piece unit that passes the connection through Unit is reversed after cable connection for the cross-connect field Mounting Frames are available 250-pair, in 50-pair, 300-pair and 900-pair
Physical. Electrical. Environmental. Insulation: Contact: Plating: Temperature Rating: -55 C to +85 C
M I/O Interconnect System 2.0 mm for IEEE 194 Wiremount Receptacle (Female) E206 Series Designed to mate to all M I/O Interconnect System 2.0 mm for IEEE 194 Boardmount Plugs Polarized to provide proper
3M Twisted Pair Flat Cable.050" 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series
M Twisted Pair Flat Cable.050" 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series Wires are color-coded for easy identification Twist and flat repeat has variable length option Can be mass terminated
Cables and Accessories Selection Guide
Cables and Accessories Selection Guide From data centers to robotics to patient monitoring equipment, we re committed to enabling the next generation of faster, smaller and smarter design. 3M offers an
Scotchlok Connectors and Tools
Scotchlok Connectors and Tools Proven Solutions For Today s Applications A New Series of Tools and Connectors from 3M. 50 years ago, 3M introduced the industry s original insulation displacement connector
Terminating 25-Pair Cable and 4-Pair Cross Connects
Terminating 25-Pair Cable and 4-Pair Cross Connects Estimated Time: 90 minutes Number of Teams: 2 Number of Team Members: one to four This Lab has four major parts that will be addressed separately. 1.
3M Wire Connectors. Reliable, high performing solutions for every wire connecting application. 3Innovation
3M Wire Connectors Reliable, high performing solutions for every wire connecting application. 3Innovation SAVE TIME, REDUCE INVENTORY YOU CAN NEVER BE TOO WELL-CONNECTED ON THE JOB The best connectors
3M Pin Strip Header Single and Dual Row.100,.235 /.318 Mating Length, Straight & Right Angle, Solder Tails 929 Series
M Pin Strip Header Single and Dual Row.100,.25 /.18 Mating Length, &, Solder Tails 929 Series Stackable Gold, Matte Sn, or -Lead plating options High Temperature (PCT) plastic for Wave or IR soldering
3M Pin Strip Header.100,.295 Mating Length, Straight & Right Angle, Solder Tails 929 Series
M Pin Strip Header.100,.295 Mating Length, Straight & Right Angle, Solder Tails 929 Series Stackable Tin Lead or gold plating available Solder stand-offs facilitate production wave soldering Board pin
BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors
C O M M E R C I A L N E T W O R K I N G C O P P E R 15.13 Distribution Connectors, Multiplying Connectors and Modular Jack Connectors A0393146 QCBIX1A4 Connector BIX Distribution Connector The BIX Distribution
MTV-FS1 / FS1T / FSB375
MTV-FS1 / FS1T / FSB375 MYE Entertainment Freestanding LCD TV Floor Stand with Base Assembly Instructions man_mtvfs1_b3 www.myeclubtv.com Table of Contents Parts List 3 Parts Identification......3 Hardware
24.2L M.A.N. V12 Engine Module
24.2L M.A.N. V12 Engine Module MANV1224 INSTALLATION INSTRUCTIONS For 24.2L M.A.N. V12 Engines V12 M.A.N. Engine Instructions Module ECM s (male and female, connect to the same ECM) ECM s (male and female,
FTTX Solutions FDH 3000 Cross-Connect
TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions
FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON
FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number 7911751VERIZON SERIAL NUMBER Flash Technology, 332 Nichol Mill Lane, Franklin, TN 37067 (615) 261-2000 Front Matter Abstract This
Anthro Tablet Charging Cabinets
Owner's Manual for Anthro Tablet Charging Cabinets Covers part numbers beginning TAB16 and TAB20. Components at a Glance The open views of the front and side of the cabinet below are for the TAB20 cabinet.
AT&T. PARTNER Plus Door Phone. Installation and Operation Manual
AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a
3M Wrist Strap and Footwear Tester 740. User s Guide
3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Start Here. 3200 Series. All-in-One Printer. Print Copy Scan. Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer
Start Here All-in-One Printer 3200 Series MS SD/HC MMC Print Copy Scan Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer Note: A USB 2.0 cable is required to connect
QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000
QUICK INSTALLATION 8-Port Telephony Gateway Model: SPA8000 Table of Contents Connect................................................. 4 Regulatory Information....................................12 WEEE
SC, FC and ST * Hot Melt Fiber Optic Connectors
SC, FC and ST * Hot Melt Fiber Optic Connectors Instructions September 1998 78-8073-7873-8 2 Contents 1.0 Safety and Helpful Hints...4 2.0 Field Termination Kit Contents...4 3.0 STÑInstallation on 900
3 740 Wrist strap + shoe tester
3 740 Wrist strap + shoe tester Operating Instructions April, 2001 740 wrist strap + shoe tester 3 < o.k. > 1 2 1 / 11 LED for «too w resistance» 740 wrist strap + shoe tester 3 < o.k. > 1 2 LED for «too
Quick Tip 19317. Introduction. Repositioning the Hookswitch Tab. Wallmount Instructions for SoundPoint IP Phones
19317 Wallmount Instructions for SoundPoint IP Phones This quick tip provides step-by-step instructions for mounting your SoundPoint IP phone to a wall. Introduction Instead of using your phone on a tabletop
LST-3800. In-Dash Digital Sonar Gauge. Installation & Operation Instructions
Pub. 988-0064-351 LST-3800 In-Dash Digital Sonar Gauge Installation & Operation Instructions The LST-3800 is a depth and temperature gauge that comes with a 200 khz transducer, features deep and shallow
Dynatel 2273 Advanced Cable and Fault Locator
Dynatel 2273 Advanced Cable and Fault Locator Operators Manual September 1999 78-8097-6517-1-B TABLE OF CONTENTS Introduction... 2 Installing or Replacing the Batteries... 2 Initial Receiver Configuration...
E8887 First Edition February 2014
E8887 First Edition February 2014 Copyright 2014 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may be reproduced, transmitted,
LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories
LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 2015 PRODUCT CATALOG 2ND EDITION LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially
UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS
UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS CONTENTS Parts List... 2 Parts Diagram... 2 Helpful Hints... 3 Installation... 4 Operation and Troubleshooting Guide... 6 Warranty Information... 8 Form #3132,
3M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series
M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series Wiper-on-wiper contact for reliable repetitive plugging Ultra-low signal skew for high data rate transmission
SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE
SP4LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE INSTALLATION AND OPERATION MANUAL MASS NOTIFICATION SYSTEM Part Number: P84767 Rev. A Copyright 2006 Cooper Wheelock, Inc. All rights reserved.
I NTERFACE CABLE ADAPTER MODULE
I NTERFACE CABLE ADAPTER MODULE The Interface Cable Adapter Module (ICAM) has two basic uses. First, it enables you to run shielded cable between the industrial sensor interface module (SIM) and the weather
UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M5 13 8 To mount outer member to rack
UPDATEUPDATEUPDATE Converting the tower chassis to a rack-mount chassis Rail overview Converting your Server to Rack-Mount The rail kit includes the following: Two rail units Five packages of screws (labeled
Retractable Screen. Replacement Screen Instructions
Retractable Screen Patent Pending Replacement Screen Instructions For RTS, RET, & RTM Products ATTENTION! Retractable screens are not intended to provide security or provide for the retention of objects,
MICROMAPPER. Users Manual. LAN Wiremap Checker
TM MICROMAPPER LAN Wiremap Checker Users Manual (English) November 00, Rev., 9/0 00-00 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. i LIMITED
Architect/Contractor Information Package
Architect/Contractor Information Package 3M SelfCheck System C-Series C1 Model 877 This package provides architects and contractors with the information necessary for the successful installation of the
Quick Reference Guide Euro Style Terminal Blocks
Quick Reference Guide Euro Style terminal block connectors feature various wire termination methods including rising cage clamp, wire protector, spring, IDC and crimp snap. The design of terminal block
Advanced Systems Tester 900AST
Advanced Systems Tester 900AST Clear skies ahead with the 900AST TESTER The internal wiring in aircraft is under constant bombardment from age, vibration and moisture especially in airplanes that work
DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060
DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060 (FOR DUSTTRAK II AND DRX AEROSOL MONITOR MODELS 8540 AND 8543) OPERATION AND MAINTENANCE MANUAL P/N 6008416, REVISION A MAY 2015 Copyright TSI Incorporated
3M Scotchcast Electrical Resin 251 Two-Part, Oven-Curing, Class F, Rigid, Filled, Epoxy Liquid Resin
3M Scotchcast Electrical Resin 251 Two-Part, Oven-Curing, Class F, Rigid, Filled, Epoxy Liquid Resin Data Sheet April 2013 Description 3M Scotchcast Electrical Resin 251 is a medium viscosity, rigid, Class
Installing Your 960 or 980 Server into a Rackmount Cabinet
Installing Your 960 or 980 Server into a Rackmount Cabinet 1 2 Contents Installing Your Gateway Server into a Rackmount Cabinet...1 Identifyingpartsintheaccessorykit...2 Rackmounthandlekit... 2 Rackmountrailkit...
Unpacking, Installation, and Customization
Unpacking, Installation, and Customization NetShelter WX Enclosure AR100 AR100HD Contents Unpacking... 1 How to Unpack the Enclosure............................... 1 Please Recycle..........................................
16/32 Channel 1U Rack Mount CCTV Power Supply
16/32 Channel 1U Rack Mount CCTV Power Supply Manual PH-A3224-GUQ Shown 16-Channel 32-Channel PTC PH-A1612-PUQ PH-A3224-PUQ Glass Fuse PH-A1612-GUQ PH-A3224-GUQ Industrial design 12 Amp 3 Amps per channel
Integrated Home Networks
Integrated Home Networks 8050 Series elephone/data Hubs Instruction Manual & Structured Wiring Guide 8053 8051 8052 8052 multiplex technology, inc. 3001 Enterprise Street, Brea, CA 92821-6213, U.S.A. 714-996-4100
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT
Main Power Connections NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT Camlok style "J" series connectors are for connection of up to a 300 Amp 120/240 VAC or 120/208 VAC electrical service. These connections
FLEX by 3M Light Module System
FLEX by M Light Module System Application FLEX by M (the Product ) is a modular lighting system for dry, interior use (the Application ). The Product allows easy creation of long, D lighting paths along
Sunny Boy Accessories SMA POWER BALANCER
Sunny Boy Accessories SMA POWER BALANCER Installation Guide SBUS-PowBal-IUS102810 IMUS-SBUS-PBL Version 1.0 US SMA America, LLC Legal Restrictions Copyright 2010 SMA America, LLC. All rights reserved.
Introduction... 3 Setting the Combination... 4 Securing the DEFCON CL... 5 Locking the DEFCON CL to your Notebook Computer...
notebook security DEFCON CL cable lock USER GUIDE Visit our Website at www.targus.com Features and specifications subject to change without notice. 2006 Targus Group International, Inc. and Targus, Inc.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Power Max Level 2 Charging Station en Installation and Operating Instructions This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
Scotchgard Multi-Layer Protective Film 1004
Scotchgard Multi-Layer Protective Film 1004 3 Technical Bulletin September, 2008 Scotchgard Multi-Layer Protective Film 1004 Application Kit (3M Part No. 70-0710-4666-1) includes: (clockwise) Heavy Duty
Scotch-Weld PUR Easy 250 Adhesive Applicator
Scotch-Weld September, 2014 Product Description PUR Easy 250 Applicator is a self contained pneumatic applicator designed to dispense 1/10 th gallon(300ml) cartridges of 3M PUR adhesives. PURs are a family
*PATENT PENDING. NS1100 / NS2200 Installation Manual & Owner s Guide
*PATENT PENDING NS1100 / NS2200 Installation Manual & Owner s Guide Installation Tips Contents 1 Control Panel 1 Spool of Signal Wire 2 Mounting Screws & Drywall Inserts 2 Wire Clips 3 Wire Ties Tools
Mini-led spotlight with magnetic base
Mini-led spotlight with magnetic base Model 95799 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.
Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s
MIRAGE. Set-Up Instructions. www.skyline-exhibits.com
MIRAGE Set-Up Instructions www.skyline-exhibits.com Table of Contents Mirage is available in many sizes from 32 tall tabletops to 92 tall backwalls. The following set-up and repacking instructions depict
How To Install A Power Supply (Uplast) With A Battery Pack
APC Smart-UPS RT SURTA48XLBP/SURTA48XLBPJ External Battery Pack User Manual Introduction/Before Installation About this Manual The APC Smart-UPS RT external battery pack (SURTA48XLBP or SURTA48XLBPJ) connects
About this Manual. Support for Your Product
About this Manual We ve added this manual to the Agilent website in an effort to help you support your product. This manual is the best copy we could find; it may be incomplete or contain dated information.
Schneider Automation Modbus Plus Network Installing Clustered Node Devices 31000939 00 Version 2.0
Schneider Automation Modbus Plus Network Installing Clustered Node Devices 3000939 00 Version.0 Modbus Plus devices must be installed as specified in a network layout plan, showing each device s mounting
Ceiling Mount Air Handler Manual
www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty
ChargePoint Home. Installation Guide. ATTENTION: Please read thoroughly and keep this installation guide.
ChargePoint Home Installation Guide ATTENTION: Please read thoroughly and keep this installation guide. Contents Meet ChargePoint Home... 3 Setup and Installation... 4 For Professional Electricians...
Zetron Desktop Microphone Manual 025-9589F
Zetron Desktop Microphone Manual 025-9589F Software License The Zetron software described in this manual is subject to the terms and conditions of Zetron's Software License Agreement, a copy of which is
TracRac G2. Overhead Rack Installation Instructions. TracRac Inc. 994 Jefferson St. FallRiver MA 02721 www.tracrac.com 800-501-1587 IN-42000_B
IN-42000_B TracRac G2 Overhead Rack Installation Instructions TracRac Inc. 994 Jefferson St. FallRiver MA 02721 www.tracrac.com 800-501-1587 Thank you for your purchase of a TracRac G2 Sliding Cargo Manaagement
User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.
User s Guide Oreck Air Purifier with HEPA Filtration Important! Read this manual carefully, and keep for future reference. Enjoy Congratulations on your purchase of the Oreck Air Purifier with HEPA Filtration.
EMI Shielding Tapes Product Selection Guide. Trusted. Performance. from the. Tape Experts
EMI Shielding Tapes Product Selection Guide Trusted Performance from the Tape Experts 3M EMI Shielding Tapes A wide variety of tapes for EMI shielding and grounding Copper, aluminum, and tin-plated copper
Nest Learning Thermostat Installation Guide. Installation step-by-step
Nest Learning Thermostat Installation Guide Installation step-by-step Contents Compatibility. 3 In the box. 4 Before you start. 5 Choose an installation method. 6 Replacing an existing wired thermostat.
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
Lionel O-27 Gauge 27 Path Remote-Control Switch Owner s Manual
70-5121-250 3/05 Lionel O-27 Gauge 27 Path Remote-Control Switch Owner s Manual Congratulations on your purchase of the Lionel O-27 Gauge 27 Path Remote-Control Switch! This non-derailing switch is operated
GPS 35 USB. installation and quick start guide
GPS 35 USB installation and quick start guide 2001 GARMIN Corporation GARMIN International, Inc. 1200 E 151 st Street, Olathe, Kansas 66062 U.S.A. Tel. 913/397.8200 Fax. 913/397.8282 GARMIN (Europe) Ltd.
Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly
Replacing the Cover Micro-Switch To remove and replace the Cover Micro-Switch you will need the following tools: #2 Phillips screwdriver (magnetic tip preferred) #1 Phillips screwdriver (magnetic tip preferred)
12-Volt Negative Ground Installation Instructions
12-Volt Negative Ground Installation Instructions For Part Number: 1141, 1164, 1165, 1181 CAUTION!!! Before installing, please read the following important information... 1. The Ignitor is designed for
InHome Water Leak Detection Package
InHome Water Leak Detection Package For Model Numbers ILD10A-L and ILD10A-B Installation Guide / Wiring Diagram For Creating Water Leak Detection-based Events with Line-Powered or Battery-Powered Sensors
Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011
WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers Installation Guide February, 2011 Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 [email protected] 1 Disclaimer The following warranty
Super Slider ADJUSTABLE FROM 3.5-12 Model #HD26229
Super Slider ADJUSTABLE FROM 3.5-12 Model #HD26229 IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS
Installation Instructions
520 Installation Instructions Thank you very much for purchasing PIAA product. Please read this entire manual before installation and use of this product. For Installers Please give this Installation Manual
2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN-00076-A
2-3 SAS/SATA II HDD Canister XC-23D1-SA10-0-R USER S MANUAL Document number: MAN-00076-A ii Preface Important Information Warranty Our product is warranted against defects in materials and workmanship
P O W E R S U P P L Y M A N U A L
POWER SUPPLY MANUAL Congratulations on the purchase of your new Corsair power supply. This User Agreement (the Agreement ) is a legal agreement between you ( You ), and Corsair Memory, Inc. ( Corsair ).
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U SURT192RMXLBP2 SURT192RMXLBP2J English 990-2485B 02/2009 Introduction About this UPS The American Power Conversion (APC ) SURT192RMXLBP2 external
HotLok Pass Through Blanking Panel
HotLok Pass Through Blanking Panel Part Numbers 1U - 10112 2U - 10113 Table of Contents Tools Required for Installation Page 2 Dimensions and Rack Requirements Page 2 Installation Procedures Page 3 Removal
OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS
Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN
Installation and Operation Guide for PD5100 Automatic Transfer Switch
Installation and Operation Guide for PD5100 Automatic Transfer Switch Member P r o gr e ssive Dynamics, Inc. 507 Industrial Rd Marshall, MI 49068 www.progressivedyn.com 2012 Progressive Dynamics, Inc.
Quick Reference Guide AMP CT Connector Series
Quick Reference Guide The AMP CT connectors are a miniature wire-to-board and wire-to-wire interconnect solution. The AMP CT connector series has proven performance in its harness making capability. A
Dell P Series Monitor VESA Mounting Bracket Installation Instructions
Dell P Series Monitor VESA Mounting Bracket Installation Instructions The VESA mounting bracket enables a Wyse cloud client to be mounted to the Dell P Series Monitor and the Dell E24 Monitor. The cloud
Discontinued. Volition. Fiber Optic Cable. 3Innovation
Volition Fiber Optic Cable Tough enough to take it. Easy to handle. The Volition Network Solution from 3M includes horizontal and backbone cable with 62.5/125 µm and 50/125 µm multimode fiber, and 9/125
AUTOMATIC SWINGING DOOR
AAADM American Association of Automatic Door Manufacturers AUTOMATIC SWINGING DOOR OWNER'S MANUAL Distributed by: Section Contents Page Caution 2 To Our Customers 3 Service Availability 3 Compliance with
7 High-Resolution Digital Photo Frame
TM 16-1003 User s Guide 7 High-Resolution Digital Photo Frame One demo photo included, as illustrated Please read this user s guide before using your new photo frame. Package contents Photo Frame AC Adapter
4RU High Density Shelf Installation Instructions
4RU High Density Shelf Installation Instructions Table of Contents General Product Information... 1.0 Safety Precautions... 2.0 Tools Required... 3.0 Package Contents... 4.0 Installing the Product Unpacking...
3M Stats and Status Software for 3M Detection System Model 8900/9900. Staff Guide
3M Stats and Status Software for 3M Detection System Model 8900/9900 Staff Guide Copyright 2009, 3M. All rights reserved. 3M Stats and Status Software for 3M Detection System Model 8900/9900 Staff Guide
