Product Guide CM-Relay



Similar documents
Technical Overview CM-2 Climate Monitor. Get yours direct at:

Technical Overview CM-16 Climate Monitor. Get yours direct at:

Computer Cabinet Environment Monitor

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

Panduit PViQ Switched POU User Manual

Instruction Manual Environmental Monitoring Unit. Watchdog 1200 Series Firmware Version 3

Instruction Manual Environmental Monitoring Unit. RSMINI-P, RSMICRO, RSMINI163 Firmware Version 3

securityprobe 5E Standard

Instruction Manual Environmental Monitoring Unit. Watchdog 1000 Series Firmware Version 3

Network Management Card. User Manual

Environmental Management System

Remote Monitoring Unit SC8100. Monitoring Unit SC8100

Light Level. Sensor. Accessory Device Connector. Serial Connector. Lamps. Temperature and Air Flow. Humidity. Sensor I/O Ports (terminals) Sensor

SNMP Web Management. User s Manual For SNMP Web Card/Box

securityprobe5es -X20

PE6108/PE6208/PE8108/PE8208

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

NMS300 Network Management System

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

HWg-STE HWg-STE PoE MANUAL

Network Power Manager. User Manual

Compatible with all of the Ravica range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.

Power Supply SNMP Interface User Manual for SRL versions

Innovative Electronics for a Changing World INDEX

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

Instruction Manual Rack Power Distribution Unit. RCX, RCM-O and RCU-O Series Firmware Version 3

Gigabyte Content Management System Console User s Guide. Version: 0.1

Alarm Messages Clearing the Hardware Alarms How to Log On Summary Page Navigation Menu... 24

3.5 EXTERNAL NETWORK HDD. User s Manual

Technical Overview Add-on Sensors - Smoke Alarm. Get yours direct at:

Poseidon MANUAL

Intelligent power sockets IQsocket tm IQSB-PicoIP. makes your life more comfortable. User guide. IQSB-PicoIP documentation v1.0 R1

Dominion PX. General Questions. What is Dominion PX (PX)?

Chapter 3 Management. Remote Management

Chapter 4 Management. Viewing the Activity Log

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

Uninterruptible Power Supply

Sensatronics Senturion Environmental Monitor Operations Manual

Cisco RV082 Dual WAN VPN Router Cisco Small Business Routers

HC Products ILF-100WD User Manual

Medical Vacuum Systems-PXMI

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES

Expert Power Control NET 4x 8212 / 8213

Sentry Bulldog Shutdown Management Software (For UNIX Series)

PN5212/PN5320/PN7212/PN7320

USER S GUIDE Switched Rack PDU

How To Log On Main Screen Control Console Menus... 19

Remote monitoring of Crouzet Millenium 3 Using Netbiter EasyConnect EC220 & Netbiter Argos

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Remote monitoring of Millenium 3 Logic Controller using Netbiter EasyConnect EC-220 & Netbiter Argos

Temperature & Environment Monitoring... Made Easy!

SentryPlus. Shutdown Management Software for Windows. User s Manual

Management, Logging and Troubleshooting

Chapter 8 Router and Network Management

Room AlertTM. 7E Advanced Computer Room Environment Monitoring, Alerting & Automatic Corrective Action! Web Server User s Guide & Reference Manual

Application Note Room Alert

NEC Express5800 Series NEC ESMPRO AlertManager User's Guide

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Tk20 Network Infrastructure

BiPAC 7404V series. VoIP/(802.11g) ADSL2+ (VPN) Firewall Router. Quick Start Guide

User s Guide. SNMPWEBCARD Firmware Version through Revision A

How to Log On Main Screen Control Console Menus How to Log On Summary Page Navigation Menu... 29

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5. Initial Configuration Requirements 6

TemPageRTM Real-Time Temperature Monitor With Data Logging, SNMP & Unlimited Alerting!

Firewall VPN Router. Quick Installation Guide M73-APO09-380

ALOHA Load Balancer Quickstart guide


Introducing Tripp Lite s PowerAlert Network Management Software

Cisco SPA901 1-Line IP Phone Cisco Small Business IP Phone

Dell Network Management Card. User's Guide. w w w. d e l l. c o m s u p p o r t. d e l l. c o m

Watchdog Monitor user guide

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

F453. TiF453. User guide 10/11-01 PC

Chapter 8 Monitoring and Logging

M O N I T O R I N G S O L U T I O N S INFRASTRUCTURE MANAGEMENT SOLUTIONS. Varicontrol-P. The Integrated Rack Management System

Online Help StruxureWare Data Center Expert

Product Description... 1 Internal Management Features... 3 Front Panel... 5 Watchdog Features... 7

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module

Power Commander Power Distribution Units from Wiremold/Legrand offer

GPS NTP Time Server for Intranet Networks DIN RAIL Version

Users manual. TCW181B-CM_R1 Page 1

RC2000 Web Server User s Manual RCI P/N: FP-SER-ETH-SERVR1

NeoGate TA Series Quick Installation Guide

SOFTWARE UTILITY OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES

DRO-210i LOAD BALANCING ROUTER. Review Package Contents

sat-nms SMU Signal Management Unit

Monitor Room Alert 7E With PageR Enterprise

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Site Power Monitor Installation/Operation Manual Model: SPM-200

Temperature Alert. LAN-based Temperature and Humidity Data Logger

CMC-TC Processing Unit II DK

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

For additional information, refer to the user guide of Yealink VP530 IP video phone or contact Yealink FAE (Field Application Engineer).

User s Manual Network Management Card

Transcription:

Product Guide CM-Relay www.theclimate.co.uk tel: 01491 410913 The Climate, Badgers Bank, Harpsden, Henley-on-Thames, Oxfordshire RG9 4HL.

Overview CM-Relay combines climate monitoring with remote relay control. The output relays can be triggered manually or tied to specific alarm settings. Includes a built-in temperature sensor and 6 analogue inputs. Supports up to 16 remote digital sensors with a total cable length up to 600. Configure alarms to get alerts by email or SNMP. Access to data logs and graphs through a simple web interface. Web-based climate monitor with output relays, digital sensor support, and expanded analogue input capabilities. Accessible through a web browser 3 output relays to control external devices Built-in temperature sensor 6 analogue inputs for 0-5 VDC sensors 4 digital sensor ports for remote sensors LCD display cycles through sensor readings Multi level alarms with escalation Alarm notifications sent by email and SNMP Audible horn triggered by alarm Output relays allow the CM-Relay to control and signal external low-voltage devices. Applications would include: Trigger an autodialer to alert personnel by phone Send a signal to a building-security system Control a larger relay to power external equipment Trigger an A/C unit with dry-contact inputs Activate a remote warning light or buzzer

CM-Relay Alarms If a sensor reading exceeds a user-defined threshold the CM-Relay sends alerts by email or SNMP trap. A special feature of the CM-Relay is to change relay status (turn on or off ) according to alarm conditions. The following table summarizes alert options: Event Latching Normal Email SNMP Trap Buzzer Alarm tripped On On trip notice trip trap On Alarm cleared Stays On Off clear notice clear trap Off cleared & acknowledged Off Alert actions for the CM-Relay (including relay behavior) Features The CM-Relay occupies a 1-U space, provides environment monitoring and contains output relays controlled either manually or triggered by alarm. Ethernet 6VDC www.theclimate.co.uk IP Reset Reboot Horn OFF tel: 01491 410913 Audible Alarm and Temperature Sensor Digital Sensor Ports Analog Inputs LCD Display (w/ Status LEDs) The Climate, Badgers Bank, Harpsden, Henley-on-Thames, Oxfordshire RG9 4HL.

Remote Sensors Analogue: Analogue sensors include dry-contact and industry standard sensors providing a 0-5VDC signal. There are connections for 6 analogue inputs. Digital: Digital sensors provide sensor data through a serial protocol. Once connected, the CM-Relay automatically detects and identifies the sensor type. With splitters, up to 16 digital sensors can be attached. Web Interface The web interface is the primary way to interact with the CM-Relay. This allows a user to remotely check the status of the environment, view graphs and webcam images, and update the firmware. Manual relay controls are also provided. CM-Relay is configured and administrated through the web interface. Access is user name and password protected. For added security, the device supports SSL encryption, provided by browsers using HTTPS. Other Access Methods Besides web access, there are several ways to obtain sensor data from the unit. Meta-tagged system info is available in XML. Logged data can be downloaded as a CSV file. The device also supports SNMP (v1, v2c, v3). This allows dozens of Network Monitoring programs such as HP OpenView, IP Sentry, MRTG, or What s Up Gold (Ipswitch) to easily add the CM-Relay to the list of monitored devices. There are several status indicators for local viewing. A back-lit LCD display cycles through real-time values, selected by the user. Bi-color LEDs under the relay terminals indicate relay state. Additional LED indicators show network activity and link status.

Device Details Built-in Sensors Temperature: -22 to 185 F (-30 to 85 C), +/- 0.5 C 3 SPDT dry-contact relays Max switching capacity: 60V, 30W Connectors: 3 screw terminals per relay 3 Relay Status LEDs (bi-color, green= on, red= off ) Remote Sensor Support Digital sensor: 4 ports (supports up to 16 with splitters) Analogue sensor: 6 inputs (contact closure, 0-5 VDC) Specifications Physical: 19 rack-mount, 1-U space Power: 6VDC (supplied wall transformer) Ethernet: 10 Mbps, RJ-45 receptacle 2 Network Status LEDs ( Link and Activity ) Real Time Clock (RTC) with power backup Reset IP push-button: restores factory defaults Horn Off push-button: silences alarm buzzer Reboot push-button: reboots system LCD Display: 2 lines x 8, back lit, cycling sensor values Warranty: 1 year (extended warranties available) Software Features HTTP / HTTPS: web access Control relays through web interface Alarms: high/low values, multiple thresholds per sensor Options to trigger relays or buzzer on alarm ESMTP / POP3: email alerts, ESMTP / POP3 auth SNMP (v1, v2c, v3): gets, trap and clear alerts, MIB Paging: email to pager proxy XML: meta-tagged sensor values, alarms, config, relays Syslog: send debug messages to Syslog server

Climate Sales Climate monitor products and supporting components are available directly via our website or you can contact us using the details below. The Original Climate Badger Banks Harpsden Henley-on-Thames Oxfordshire RG9 4HL tel: 01491 410913 web: www.theclimate.co.uk