SMD-301. Smoke Dampers Steel Airfoil Blades UL 555S Leakage Class I. Application. UL555S Leakage Rating. Size Limitations. Features: Maximum Size*

Similar documents
AMD-33 Air Measuring Station with VCD-33 Control Damper

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.

Life Safety Dampers Selection and Application Manual. Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers

HVAC Control & Balancing Dampers Models VCD, MBD and RBD

DUCT SMOKE DETECTOR D4120

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS

PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB

FIRE DAMPER APPLICATION GUIDE

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

CURTAIN TYPE FIRE DAMPERS

POWERS Controls No. 4 Pneumatic Damper Actuator

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

Fire and Smoke Dampers: Best Practice Design Tips. An AMCA International White Paper. July 2015

ISSUE A, MAY Mechanical Release Fire Smoke Dampers. Model Advanced Air

4 Installation Requirements

AIR CONDITIONING PRODUCTS COMPANY

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

CARNES COMPANY 448 S. Main St., P. O. Box , Verona, WI Phone: (608) Fax: (608) Depth (10 std.

Dampers and Actuators Catalog

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

product application guide

plenum slot diffusers

Subject: DKS Steel Door and Frames Systems, Inc., ITS / Warnock Hersey Procedural Specification, Certification, and Inspection.

Automatic Door Selection Guide

ROOF TOP MOUNTED Air Handler Specification

Roof Curbs, Extensions and Equipment Supports

Damper Selection and Sizing

DUCT SYSTEMS CHAPTER 6

E-PDD Duct Smoke Detector Installation Sheet

4-Wire Air Duct Smoke Detector. Protection Systems. A UTC Fire & Security Company. Models DH-60 FEATURES APPLICATION DESCRIPTION SAMPLING TUBES

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

Element D Services Heating, Ventilating, and Air Conditioning

How To Test For An Architectural Test

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

AMCA Publication (Rev )

Lift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge...

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

Ventilation Solutions Kitchens. fantech

Section 5: Machine Overview

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

EMF/EMR. Holder/Release Devices with Integral Door Closers

PART 1 GENERAL 1.1 SECTION INCLUDES

Installation Instructions and Ordering Information

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

DE Frame with C Series Sidelight

VariTrane Duct Designer An in depth look...

INDEX. Chapter8. air master. Perforated Ceiling Diffusers

security products metric sizes Redefine your comfort zone.

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

City of San Diego, CWP Guidelines

SECTION HVAC AIR DISTRIBUTION

DOORS HOLLOW METAL MANUAL NAAMM STANDARD NAAMM HMMA METAL DOORS & FRAMES METAL. A Division of

VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes. Accurate airflow measurement for demanding applications

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24


STANDARD FOR NON-FIRE RATED ROLLING DOORS

CONCEALED BEARING HINGES. StANLEy ARCHItECtuRAL HARDwARE

WHI TEST REPORT # FIRE RATED DOORS

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

An ASSA ABLOY Group brand. 4800LN Series. Interconnected Locks

PHA 2000 PHB 3000 EXIT PAD

bts 80 f/emb/flb/bsr Floor spring system

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

BLADE S-MAX Cabinet for Blade Server

Scraper Passage Indicator. Electrical Indicator. Features

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Terminal Boxes Series 8146

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Incorporating V2.3. Product spec >>> > Series ECG - Egg Crate Grilles. > Series ECG45-45 Egg Crate Grilles

Butterfly Valves PN 6/10/16 for flanged connection

UPBLAST & HOODED PROPELLER ROOF VENTILATORS

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

Uni-Quick Duct System. Moveable. Uni-Quick. Duct System. DUST COLLECTION and MATERIAL HANDLING APPLICATIONS a McGill AirFlow product

Cooktop Low-Profile Ventilation Hoods

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

Electrified Products TABLE OF CONTENTS. Power Transfers...12 Pressure Sense Bars...12 Proximity Cards & Keys... 4

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

National System of Garage Ventilation s Engineering Guide

The risk assessment of fire damper installations

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES

Miami-Dade Qualified Drainable Blade Louvered Penthouse

280+ Mortise Mounted Series Shear Locks Special Application Solution

Series 3502 Thermal Series 3902 Fixed Thermal Architectural Grade Horizontal Sliding Window

Pipe Cutting and Beveling Clamshells

STANLEY DOOR CLOSERS D-4550/D-4551 D-4550 / D-4551 SERIES OOR CLOSERS

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

Electrical Wiring Technical Bulletin

TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER

PERFORMANCE TEST REPORT. Rendered to: BAMCO INC. PRODUCT TYPE: ACM Wall Panel Systems

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Speed-Mat Rectangle Cutter

Transcription:

R Application Model is a leakage rated smoke damper with extremely low leakage. The serves the function of both a control damper and smoke damper. High strength airfoil blades insure lowest resistance to airflow in HVAC systems with velocities to 4000 fpm (20.3m/s) and 8 in. wg (2 kpa) Model may be installed vertically (with blades running horizontal) or horizontally and is rated for airflow and leakage in either direction. UL555S Leakage Rating Leakage Class: I Operational Rating Maximum : Maximum Pressure: 4000 fpm (20.3 m/s) 8 in. wg (2 kpa) Maximum Temperature: 350ºF (177ºC) depending on actuator Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness Frame Type 16 ga. (1.5mm) - 5 in. x 1in. (127mm x 25mm) hat channel Blade Material Galvanized Steel - Blade Material Thickness 14 ga. (2mm) Equivalent Blade Type Double Skin Airfoil - Linkage Plated Steel Out of Airstream, Concealed in Jamb Axle Bearings Bronze 304SS Axle Material Plated Steel - Blade Seals Silicone - Jamb Seals 304SS - Size Limitations W x H Size Single Section Maximum Size* - - - Multiple Section Inches 8 x 6 32 x 50 192 x 100 mm 203 x 152 813 x1270 4877 x 2540 Note: Maximum sizes are dependent on velocities and pressures. Features: Frames are constructed with reinforced corners. Low profile head and sill are used on sizes less than 17 in. high (432mm). Blades are double skin airfoil shape of galvanized steel with full length structural reinforcement Actuators: 120V, 24V, 230V, Pneumatic Model meets the requirements for smoke dampers established by: National Fire Protection Association NFPA Standards 92A, 92B, 101 & 105 IBC International Building Codes New York City (MEA listing #260-91-M) Smoke Dampers Steel Airfoil Blades UL 555S Leakage Class I CSFM California State Fire Marshal Leakage (Smoke) Damper Listing (#3230-0981:104) LH UL CLASSIFIED (see complete marking on product) UL CLASSIFIED to Canadian safety standards (see complete marking on product) Standard 555S (Listing #R13317) W* *W&H dimensions furnished approximately 1 /4 in. (6mm) undersize. Right hand drive is shown. Left hand drive is available upon request. Damper also may be rotated 180 in the field for opposite side drive. (Add sleeve thickness for overall sleeved damper dimension) RH H* Installation instructions available at www.greenheck.com

Options & Options for : Factory mounted accessories - Retaining angles - Quick connect breakaway connections - S & drive connections - Access doors Greenheck test switches (GTS-3 & GTS-4) Momentary test switch POC retaining angles OCI (Open closed indication switches) Sealed transitions and sleeves Security bars Smoke detectors Transitions: R, C, O Data This pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of.075 lb/ft 3 (1.201 kg/m 3 ). Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. 6D Figure 5.3 D 4 (W) (H) 3.14 Figure 5.2 Figure 5.5

R AMCA Figure 5.2 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36in. x 36 in. (914mm x 914mm) 12in. X 48 in. (305mm x 1219mm) 48 in. x 12 in. (1219mm x 305mm) 500 0.03 500 0.01 500 0.01 500 0.01 500 0.02 1000 0.12 1000 0.06 1000 0.06 1000 0.05 1000 0.08 1500 0.26 1500 0.12 1500 0.12 1500 0.12 1500 0.18 2000 0.46 2000 0.22 2000 0.22 2000 0.21 2000 0.33 2500 0.72 2500 0.34 2500 0.34 2500 0.33 2500 0.51 3000 1.04 3000 0.49 3000 0.49 3000 0.48 3000 0.74 3500 1.41 3500 0.67 3500 0.67 3500 0.65 3500 1.00 4000 1.84 4000 0.87 4000 0.88 4000 0.85 4000 1.31 AMCA Figure 5.3 6D 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36in. x 36 in. (914mm x 914mm) 12in. X 48 in. (305mm x 1219mm) 48 in. x 12 in. (1219mm x 305mm) 500 0.01 500 0.01 500 0.01 500 0.01 500 0.01 1000 0.06 1000 0.02 1000 0.02 1000 0.02 1000 0.04 1500 0.13 1500 0.06 1500 0.05 1500 0.06 1500 0.10 2000 0.23 2000 0.10 2000 0.09 2000 0.10 2000 0.18 2500 0.37 2500 0.16 2500 0.14 2500 0.16 2500 0.29 3000 0.53 3000 0.23 3000 0.21 3000 0.24 3000 0.42 3500 0.73 3500 0.32 3500 0.29 3500 0.33 3500 0.57 4000 0.95 4000 0.42 4000 0.38 4000 0.43 4000 0.74 AMCA Figure 5.5 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36in. x 36 in. (914mm x 914mm) 12in. X 48 in. (305mm x 1219mm) 48 in. x 12 in. (1219mm x 305mm) 500 0.04 500 0.03 500 0.03 500 0.03 500 0.03 1000 0.18 1000 0.13 1000 0.12 1000 0.12 1000 0.14 1500 0.42 1500 0.29 1500 0.27 1500 0.27 1500 0.32 2000 0.75 2000 0.52 2000 0.48 2000 0.49 2000 0.57 2500 1.17 2500 0.81 2500 0.75 2500 0.77 2500 0.89 3000 1.68 3000 1.17 3000 1.08 3000 1.11 3000 1.28 3500 2.29 3500 1.60 3500 1.48 3500 1.51 3500 1.75 4000 2.09 4000 2.14 4000 1.93 4000 1.97 4000 2.29 Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only.

Application Data Space Envelopes Required for Actuators and Accessories Externally mounted actuators always require space outside of the damper sideplate or sleeve. The S dimension illustrates the clearance required for various available actuators. On dampers less than 18 in. (457mm) high, actuators may also require clearances above and/or below the sideplate or sleeve. B and T dimensions are worst case clearance requirements for some dampers less than 18 in. (457mm) high. All damper sizes under 18 in. (457mm) high do not require these worst case clearances. If space availability above or below the damper sleeve is limited, each damper size should be individually evaluated. S T* B* Actuator Type/Model B* T* S With RRL, RRL/OCI, or TOR With RRL, RRL/OCI, or TOR 120 Volt AC No PiggyBack FSLF120 (-S) Belimo 3 1/2 in (89mm) 0 6 in. (152mm) NA FSNF120 (-S) Belimo 12 3/4 in. (324mm) 0 6 in. (152mm) 9 in. (229mm) FSTF120 (-S) Belimo 3 1/2 in. (89mm) 0 6 in. (152mm) NA ML4XXX Series Honeywell 4 3/4 in. (121mm) 0 6 in. (152mm) NA MS4X09 Series Honeywell 4 3/4 in. (121mm) 0 6 in. (152mm) NA MS4120 Series Honeywell 12 3/4 in. (324mm) 0 6 in. (152mm) 9 in. (229mm) 24 Volt AC FSAF24 (-S) Belimo 12 3/4 in. (324mm) 0 6 in. (152mm) NA FSAF24-BAL (-S) Belimo 12 3/4 in. (324mm) 0 6 in. (152mm) NA FSLF24 (-S) Belimo 3 1/2 in (89mm) 0 6 in. (152mm) NA FSNF24 (-S) Belimo 12 3/4 in. (324mm) 0 6 in. (152mm) 9 in. (229mm) ML8XXX Series Honeywell 4 3/4 in. (121mm) 0 6 in. (152mm) NA MS8X09 Series Honeywell 4 3/4 in. (121mm) 0 6 in. (152mm) NA MS8120 Series Honeywell 12 3/4 in. (324mm) 0 6 in. (152mm) 9 in. (229m) 230 Volt AC FSLF230 (-S) Belimo 3 1/2 in (89mm) 0 6 in. (152mm) NA FSNF230 (-S) Belimo 12 3/4 in. (324mm) 0 6 in. (152mm) 9 in. (229mm) ML4XXX Series Honeywell 4 3/4 in. (121mm) 0 6 in. (152mm) NA MS4X09 Series Honeywell 4 3/4 in. (121mm) 0 6 in. (152mm) NA MS4620 Series Honeywell 12 3/4 in. (324mm) 0 6 in. (152mm) 9 in. (229mm) Pneumatic (25 psi min.) 331-4551 Siemans 7 1/2 in. (191mm) 0 6 in. (152mm) NA 331-2976 Siemens 12 3/4 in. (324mm) 0 6 in. (152mm) NA 331-2856 Siemens 2 1/2 in. (64mm) 0 9 in. (229mm) NA MK2-7121 TAC (Invensys) 2 1/2 in. (64mm) 0 9 in. (229mm) NA Yes * For dampers 18 in. (457mm) or more in height these dimensions are 0 in..

Application Data Damper Sideplate and Sleeve Dimensional Data The drawings below illustrate the factory standard sideplate and sleeve mountings for the. The standard "A" dimensions listed in the table provide adequate space for the mounting of actuators and controls. If space constraints are a problem the "A" dimension can be varied between 5 3 /8 in. (136mm) and 12 in. (305mm). Sideplate in. (mm) Standard "A" Dimension Sleeve Maximum Sideplate All Dampers* 7 3/16 (183) 12 (305) 6 3/16 (157) When height is 11 in. (279) or less with OCI 11 3/16 (284) 12 (305) 10 3/16 (259) Sleeve 3 3 /4" 11/2" max. 6 in. (152mm) A 5 in. (127mm) Sideplate Length *With the exception of dampers 11 in. (279mm) high or less (12 in. (305mm)high or less if width is greater than 64 in. (1625mm)) with OCI option. ** On dampers 11 in. (279mm) high or less (12 in. (305mm)high or less if width is greater than 64 in. (1625mm)) with OCI option, sideplate is 16 in. (406mm) Varies 5 3 /8" A 5" Sleeve Length Damper Sizing Information Dampers larger than maximum single section size are supplied as a factory assembly of two or more sections of equal size. The following figures show damper sections and assemblies that have been qualified for operation with a single actuator. Larger sizes can be accommodated using multiples of these assembles. Single Section Double Section 50 in. (1270mm) 50 in. (1270mm) 32 in. (813mm) 32 in. (813mm) 64 in. (1626mm)

Transitioned Damper Dimensions When a fire/smoke damper is being used in conjunction with round or oval ductwork, the can be supplied in a factory sleeve with round or oval transitions on both ends of the sleeve. Dampers should be ordered to the duct dimensions. Drawings below show overall damper size. D* + 2 in. (51mm) +Ts W* + 2 in. (51mm)+T s W* + 2 in. (51mm)+T s D* + 2 in. (51mm)+T s 2 1/8 in. (54mm) H* + 2 in. (51mm)+T s 2 1/8 in. (54mm) H* H* + 2 in. (51mm)+T s 2 1/8 in. (54mm) H* 16 in. (406mm) D* 16 in. (406mm) W* 16 in. (406mm) W* TYPE R TYPE O TYPE C * These dimensions are furnished approximately 1 /4 in. (6mm) undersize, except round and oval dimensions which are approximately 1 /8 in. (3mm) undersize. Ts = (2)(Sleeve Thickness) Specifications Smoke Dampers meeting the following specifications shall be furnished and installed where shown on plans and/or as described in schedules. Dampers shall meet the requirements of NFPA 92A, 92B, 101 and 105 and further shall be tested, rated and labeled in accordance with the latest edition of UL Standard 555S. Smoke dampers shall be of low leakage design qualified to UL 555S Leakage Class I. Each damper /actuator combination shall have a UL555S elevated temperature rating of 250 F (121º C) minimum and shall be rated to operate at maximum design air flow at its installed location. Each damper shall be supplied with an appropriate actuator installed by the damper manufacturer at the time of damper fabrication. Damper actuator shall be (specifier select one of the following) electric type for 120 (24 or 230) Volt operation or pneumatic type for 25 psi minimum (30 psi maximum) operation. Damper blades shall be of the double skin airfoil type and shall have an equivalent metal thickness of 14 ga. (2mm) Damper frame shall be galvanized steel formed into a structural hat channel shape with reinforced corners. Bearings shall be sintered bronze sleeve type rotating in extruded holes in the damper frame. Blade edge seals shall be silicone rubber designed to inflate and provide a tighter seal against leakage as pressure on either side of the damper increases. Jamb seals shall be stainless steel compression type. Blades shall be completely symmetrical relative to their axle pivot point, presenting identical resistance to airflow in either direction or pressure on either side of the damper. Damper must be rated for mounting vertically (with blades running horizontal) or horizontally and be UL 555S rated for leakage and airflow in either direction through the damper. The basis of design is Greenheck Model. Copyright 2015 Greenheck Fan Corporation Rev. 11 June 2015