Main Offices and Factory

Similar documents
S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

Pressure and Temperature Controls

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

VAD Variable Area Desuperheaters

VAD. Variable Area Desuperheaters

QLM and QLD Series Three-port Control Valves

Type 92S Pilot-Operated Steam Regulator

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

RUBBER SLEEVE KNIFE GATE VALVE

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Direct steam injection humidifiers

2- and 3-port valves with flanged connections, PN 10

Type 3353 Angle Seat Valve

GS-General Service Control Valves

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

valve solutions Chemical Cosmetic Cryogenic Food & Beverage Marine Mining Nuclear Oil & Gas Paint Pharmaceutical Pulp & Paper

Industrial Steam System Process Control Schemes

HOPPER SHAPE KNIFE GATE VALVE

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range

V47 Series Temperature Actuated Modulating Water Valves

PRESSURE REDUCING CONTROL VALVE

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Overview of the. measurement and control technology range

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

REGULATORS D& HD Series

DOUBLE SEAT BRONZE BODY HIGH CAPACITY

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

DOUBLE GATE KNIFE GATE VALVE

Kämmer Series Laboratory Valves

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

ARI-ASTRA / ASTRA Plus Combinend flow regulating valve

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

WD600 STEAM TRAPS. Thermodynamic Steam Trap

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

FlowPak TM General Application Valve 1/2-4, Class 150

How To Use A Flowmeter

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

PBM has solutions for your valve application.

HERZ-Thermal Actuators

Digital inductive conductivity transmitter

CCI 100 DPC DRAG Wellhead Production Choke Valve

Fisher 657 and 667 Diaphragm Actuators

The Axial Flow Valve. Class 300/ SERIES

Float and Thermostatic Traps Series H, C and X

VALVE TECHNOLOGY ONE STEP AHEAD.

PBX Series Quick Fit Connector Bimetallic Steam Traps

Vacuum Gate Valve DN 100 and DN 150

VALVE TECHNOLOGY ONE STEP AHEAD.

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

API Flanged Safety Relief Valves Series 526 CATALOG

BULLETIN OCTOBER DeZURIK ROTARY DIAPHRAGM ACTUATORS

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Assisted lift operated 2/2-way solenoid valves Type EV250B

Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators

MFP14, MFP14S and MFP14SS Automatic Pumps

Tyco PremiAir Pneumatic Actuators

PRESSURE REDUCING VALVES

APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module.

Butterfly Valves PN 6/10/16 for flanged connection

Grey cast iron Fig. 600 Page 2. Forged steel High temperature steel Stainless steel Fig. 600/601 (Y) DN15-25 Page 4 DN40-50 Page 6

Example. Fluid Power. Circuits

SD SEVERE DUTY CONTROL VALVES BULLETIN 1149 JULY 2002

COUNTERBALANCE VALVES

Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

T U R B I N E G A S M E T E R

Self-operated Temperature Regulators Temperature Regulator Type 1u

Electric Rotary Actuator - On/Off or programmable control actuator

Pressure & Flame Protection

BUTTERFLY VALVES API 609 WAFER LUG U-SECTION BODY STYLE DIAPHRAGM VALVES EN13397:2000 WEIR BODY STYLE

1.1 Z 011-A WAFER PATTERN BUTTERFLY TYP Z 011-A TECHNICAL DATA

Contents. LWN edition:

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

FlowLine Controls. An Engineer's Guide for Sizing and Specifying Pressure Independent Control Valves for Building Services

BERMAD Waterworks. High Pressure, Surge Anticipating Control Valve. 800 Series. Model 835-M. Features and Benefits. Major Additional Features

Baumann Way Bronze or Stainless Steel Control Valve

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Thermostatic element RAVV for 2-way valves

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

ABsOlute flow control. SERIES 3E // DN (6-16 ) // Oil & Gas // Power Generation // Petrochemistry TRIPLE OFFSET BUTTERFLY VALVES

MP8000 Series Pneumatic Valve Actuators

Control- and feedback head for integrated mounting on Robolux valves Type 2036

A descriptive definition of valve actuators

REGULATING VALVE APPLICATIONS

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

FT43, FT44, FT46 and FT47 Ball Float Steam Traps

Unit 24: Applications of Pneumatics and Hydraulics

Pressure reducing valves. for steam and industrial fluids

Transcription:

Main Offices and Factory Design, Manufacture and Servicing of Pneumatic/Electric Powered Valves, Control&ON-OFF Valves and Self-Acting Pressure Reducers Trading of Heat Exchangers & Components for Industrial Plants Automation - Integrated Solution for Industry

Pneumatic Control Valves

PNEUMATIC CONTROL VALVES Two way Valves - Single seat TYPE 2000 AR control Normally closed air opens Face-to-face EN 558-1 (DIN 3202) From DN 15 to DN 100 TYPE 2100 AR ON-OFF Normally closed air opens Face-to-face EN 558-1 (DIN 3202) From DN 15 to DN 100 TYPE 2100 AD ON-OFF Normally opened air closes Face-to-face EN 558-1 (DIN 3202) TYPE 2000 AD control Normally opened air closes Face-to-face EN 558-1 (DIN 3202) From DN 15 to DN 100 From DN 15 to DN 100 TYPE 2100 DE ON-OFF Double effect - air closes air opens Face-to-face EN 558-1 (DIN 3202) From DN 15 to DN 100

TYPE 5000 AD control Normally opened air closes Face-to-face ASME / ANSI B16.10 From DN 15 to DN 200 TYPE 5100 AD ON-OFF Normally opened air closes Face-to-face ASME / ANSI B16.10 From DN 15 to DN 200 TYPE 5000 AR control Normally closed air opens Face-to-face ASME / ANSI B16.10 From DN 15 to DN 200 TYPE 5100 AR ON-OFF Normally closed air opens Face-to-face ASME / ANSI B16.10 From DN 15 to DN 200 TYPE 5100 DE ON-OFF Double effect air closes air opens Face-to-face ASME / ANSI B16.10 From DN 15 to DN 200

Three way Valves Mixing TYPE 2600 AD A = CLOSED C-B = OPENED TYPE 2600 AD control Normally closed port A on air failure TYPE 5600 AD A = CLOSED C-B = OPENED TYPE 5600 AD control Normally closed port A on air failure TYPE 2600 AR C = CLOSED A-B = OPENED Face-to-face EN 558-1 From DN 15 to DN 100 TYPE 2600 AR control Normally closed port C on air failure TYPE 5600 AR C = CLOSED A-B = OPENED Face-to-face ASME / ANSI B16.10 From DN 15 to DN 200 TYPE 5600 AR control Normally closed port C on air failure Face-to-face ASME / ANSI

TYPE 2700 AD DN15-20 B = CLOSED A-C = OPENED TYPE 2700 AD control Normally closed port B DN15-20 TYPE 2700 AR DN15-20 C = CLOSED A-B = OPENED TYPE 2700 AR control Normally closed port C DN15-20 TYPE 2700 AD DN25-100 Normally closed port C DN25-100 TYPE 2700 AR DN25-100 Normally closed port B DN25-100 C = CLOSED Face-to-face EN 558-1 B = CLOSED Face-to-face EN 558-1 A-B = OPENED From DN 15 to DN 100 A-C = OPENED From DN 15 to DN 100

Three way Valves Diverting TYPE 5700 AD DN15-20 TYPE 5700 AD control TYPE 5700 AR DN15-20 TYPE 5700 AR control B = CLOSED On air failure: C = CLOSED On air failure: A-C = OPENED TYPE 5700 AD DN25-100 C = CLOSED A-B = OPENED Normally closed port B DN15-20 Normally closed port C DN25-200 Face-to-face ASME / ANSI B16.10 A-B = OPENED TYPE 5700 AR DN25-100 B = CLOSED A-C = OPENED Normally closed port C DN15-20 Normally closed port B DN25-200 Face-to-face ASME / ANSI B16.10 From DN 15 to DN 200 From DN 15 to DN 200

Pneumatic Control Valves

3.1 Temperature Control THE CONFLOW s.p.a.

3.4 Temperature Control THERMOIL / SUPERHEATED WATER CONFLOW s.p.a.

3.5 Pressure reducing station with Control Valve CONFLOW s.p.a.

3.6 Flow rate control CONFLOW s.p.a.

LOW NOISE INTRODUCTION Conflow s control valves Low Noise minimize hydrodynamic noise even under the most severe liquid and steam application. Warning! High acoustic noise levels are accompanied by high mechanical vibration levels and vibrations can cause failure of the valve, for this reason noise control trim (inside the valve) should always considered in any high energy ( high differential drop pressure ). Conflow s control valves Low Noise are equipped with one or two-stage cages by permitting up to 12% dba noise reduction for each stage. The reduction of the noise is made by high numbers of holes of small diameter. Having a multi-hole cage the valve can permit also a very high range-ability. The cage is constructed from heavy-duty, 316 stainless steel, drilled-hole cylinders, for this reason we can obtain lower prices and quicker deliveries. All internal parts are inter-changeability and the simplicity of the design also permits easy removal and cleaning. Double Cage

Simple Cage on Types 2200 and 5200

Double Cage on Types 2400 and 5400

From DN65 up to DN200 the valve could be equipped with balanced plug to obtain high differential drop pressure

Double cage valve cut sample

Double cage valve cut sample

TYPE 2200 AD control Integral cage plug Normally opened air closes Face-to-face EN 558-1 From DN 15 to DN 50 TYPE 2200 AR control Simple cage Normally closed air opens Face-to-face EN 558-1 From DN 15 to DN 50

TYPE 5200 AD control Integral cage plug Normally opened air closes Face-to-face ASME / ANSI B16.10 From DN 15 to DN 50 TYPE 5200 AR control Simple cage Normally closed air opens Face-to-face ASME / ANSI B16.10 From DN 15 to DN 50

2300 Simple Cage TYPE 2300 AD control Simple cage TYPE 2400 AD control Double cage Normally opened air closes Face-to-face EN 558-1 2400 Double Cage From DN 65 to DN 100 TYPE 2300 AR Simple cage TYPE 2400 AR Double cage Normally closed air opens Face-to-face EN 558-1 From DN 65 to DN 100

5300 Simple Cage TYPE 5300 AD control Simple cage TYPE 5400 AD control Double cage Normally closed air opens Face-to-face ASME / ANSI B16.10 From DN 65 to DN 200 5400 Double Cage TYPE 5300 AR Simple cage TYPE 5400 AR Double cage Normally closed air opens Face-to-face ASME / ANSI B16.10 From DN 65 to DN 200

ELECTRIC POWERED VALVES There are two different lines TENSION OPENS AND CLOSES Standard manual handwheel Standard supply 220 V AC Optional 24 V AC 110 V AC Standard Input signal 3 points modulating Optional Input signal 4-20 ma (with potentiometer and positioner card) Optional Input signal 0-10 V (with potentiometer and positioner card)

SPRING RETURN Safety Condition Standard manual handwheel with lock Standard supply 24 V AC DC ( same electronic card ) Optional : Supply 220 V AC ( only with 3 points modulating input signal) Standard Input signal 4-20 ma 0-10V 3 points modulating

SPECIAL APPLICATIONS Smart Actuator ATEX Actuator

HYGIENIC VALVES Hygienic Valves are recommended in pharmaceutical and food industry, their distinctive features are: 1. High cleaning level 2. Usage flexibility The body Valve is wholly made in Stainless-steel AISI 316L with a special care to prevent any deposit area. Clamp connections, between upper and lower body of the Valve, provide a rapid disassembly essential to carry out the Industrial Cleaning Process ICP. Control Valves are equipped with a Pneumatic actuator made in Carbon-steel painted RAL 5020 or Stainless-steel AISI 304. ON-OFF Valves are equipped with a piston actuator, simple or double effect, made in Stainless-steel AISI 304. TYPE 1200 AR Normally closed Air opens From DN 15 to DN 100

Hygienic control and ON-OFF Valves

7.4.1 Milk Pasteurization DPC = Differntial Pressure Controller TC1 = Temperature Controller Milk pasteurization TC2 = Temperature Controller Milk Cooling TC3 = Master Temperature Controller E.V. = Expansion Vessel CONFLOW s.p.a.

7.4.3 Filler Automation LC = Level Controller PC = Pressure Controller (Inlet CO2 - Outlet CO2) CONFLOW s.p.a.

WHAT IS A PRESSURE REDUCER Pressure reduction is a thermodynamic process carried out to adapt and to stabilize the pressure according to the user requests. The flow modulation (made by a good working reducer) counterbalance immediately the imbalances produced by flow or pressure alterations; it also keeps pressure value within the preset range. Naturally a self-actuated pressure reducer can t reach high range-ability values like a control valve; therefore if the flow or the pressure alteration is considerable it s better to use a control valve as pressure reducer. There are two types of pressure reducers made by CONFLOW s.p.a. : Type RP 13 and RP 300, these are self-actuated proportional pressure reducers, composed by a direct action single seat special body valve. In RP13/300 the flow tries to close the passageway while the feedback spring, controlled by downstream pressure, tries to open it. These two different forces generate the reducing effect. The heads of RP13/300 are interchangeable according to the reduced pressure range set by the user. In case of steam reduction the RP13/300 is provided with a dash pot and all the needed connections to guarantee a water cooling system to the head of the pressure reducer. Type RP 10, is a pressure reducer self-actuated internally. In RP10 the main fluid tries to close the plug and the balancing bellows while the feedback spring tries to open it. Three different types of springs provide three different reduction ranges.

SELF ACTUATED PRESSURE REDUCER (PRV) TYPE RP13 Cast Iron EN-GJL-250 PN16 Carbon Steel 1.0619 PN40 Face-to-face EN 558-1 From DN 15 to DN 100

SELF ACTUATED PRESSURE REDUCER (PRV) TYPE RP300 Carbon Steel ASTM A 216 WCB Flanged ANSI B16.5 150 RF 300 RF Face-to-face ASME / ANSI B16.10 From DN 15 to DN 100

TYPE RP10 Carbon Steel Nickel Plated PN25 Stainless-steel AISI 316 L PN25 Flanged Screwed

9.3.1 Pressure reducing station with RP13 CONFLOW s.p.a.

POWER GENEX by CONFLOW PPL Pneumatic Linear EPL Electro-pneumatic linear PPR Pneumatic rotary EPR Elettro-pneumatic rotary

SEL with AUTO-TUNING FUNCTION Linear Digital

SER with AUTO-TUNING FUNCTION Rortary Digital

SSL Smart Linear SSR Smart Rotary

LINEAR POSITIONERS Mechanical ZERO setting Mechanical SPAN setting

DIGITAL POSITIONERS Electronic ZERO setting AUTO-TUNING Electronic SPAN setting Electronic SPEED setting Electronic DUMPING setting

SMART PILOT POSITIONER with DISPLAY All settings by keyboard

ELECTRO PNEUMATIC CONVERTER TYPE IPC DIGITAL IPC converter is employed for conversion of a standard DC current signal into a standard pneumatic signal. IPC converter is provided of high speed piezoelectric valve with the possibility to obtain zero output signal for a correct control of pneumatic control valves without pilot positioner.

MOUNTING RAIL DIN EN 50022 35 mm ZERO DUMPING SPAN

BALL FLOAT STEAM TRAPS TYPE GTS SCREWED GTF FLANGED GTS - Ø 1/2 - Ø 3/4 - Ø 1 Internal materials: Stainless-steel AISI 304 GTF - DN 15 - DN 20 - DN 25 Body materials: Cast Iron GGG40.3 TYPE GTSH SCREWED GTFH FLANGED GTSH - Ø 1 - Ø 1.1/2 - Ø 2 Internal materials: Stainless-steel AISI 304 GTFH - DN 25 - DN 40 - DN 50 Body materials: Cast Iron GGG40.3

THERMOSTATIC STEAM TRAPS TYPE TYPE STK 42 STK 11 Available diameters : - Ø 1/2 standard - Ø 3/4 - Ø 1 a richiesta Internal and body material: - Stainless-steel AISI 304 Available diameters : - Ø 1/2 Internal and body material: Stainless-steel AISI 304 Body and cap: Brass Cu-Zn 40 Pb2

TYPE STK 61 Available diameters : - Ø 1/2 Internal and body material: Stainless-steel AISI 304 Body and cap: Brass Cu-Zn 40 Pb2

THERMODYNAMIC STEAM TRAPS TYPE TDK 42 Available diameters: - Ø 1/2 standard - Ø 3/4-1 a richiesta Body material: Acciaio Inox ASTM A743 Internal material: Stainless Steel AISI 304 DESCRIPTION (THERMODYNAMIC STEAM TRAP) The main characteristic of the Thermodynamics steam traps is the movement of the internal plug (typical disk shape) who allows the condensate to be discharged as soon as the steam, present in the upstream chamber, will transform in a liquid state. When the vapour state arise again, the pressure and the plug closure prevent any further steam leakage.