SMART SENSOR COLLECTION

HWg-STE HWg-STE PoE MANUAL

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

IntesisBox KNX LG Air Conditioning

User Manual. EtherUSB

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

IntesisBox Modbus Server SAMSUNG Air Conditioners

SNMP Web Management. User s Manual For SNMP Web Card/Box

IntesisBox KNX Modbus TCP master

Uninterruptible Power Supply

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

PE6108/PE6208/PE8108/PE8208

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Modbus Server SAMSUNG Air Conditioners

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

MAJORSINE Power Inverter

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

securityprobe 5E Standard

User Manual. EtherUSB

IntesisBox Modbus Server Fidelio IP

How To Run An Nport I5000A Device Server

Outdoor-Ready Box. Hardware Manual KCM-5211E, KCM-5311E KCM-5511, KCM Ver. 2014/10/15

Compatible with all of the Ravica range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

securityprobe5es -X20

8-Port PoE Network Switch

KNX Panasonic Air Conditioners

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

ROOM GUARD VT300. Environmental Infrastructure monitoring

OZS Web server. For LPB/BSB plants

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Poseidon MANUAL

Zertico Rack Monitoring Unit

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Temperature & Humidity SMS Alert Controller

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Model #: SMART2200CRMXL

RC8021 Indoor Camera Installation Guide

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

Technical Overview CM-2 Climate Monitor. Get yours direct at:

Fire & Security DETECTORS

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

DSL Installation Guide

TrueAlarm Fire Alarm Systems

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Remote Monitoring Unit SC8100. Monitoring Unit SC8100

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

HARTING mcon 1000 Introduction and features

PE8216/PE8324. Energy Intelligence Solutions

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

RC8061 Pan and Tilt Camera Installation Guide

IP DSLAM IDL Quick Installation Guide

GPS NTP Time Server for Intranet Networks DIN RAIL Version

IntesisBox KNX - LON

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

MSNswitch: 1. Automatically Power-Cycle Unresponsive Network Devices 2. Watch-Dog for Network Devices

Intelligent power sockets IQsocket tm IQSB-PicoIP. makes your life more comfortable. User guide. IQSB-PicoIP documentation v1.0 R1

OC810 Outdoor Camera Setup Guide

Computer Cabinet Environment Monitor

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Job Aid Pre-Installation Information S8500 Media Server

2012 uptimedevices.com

OC810 Outdoor Camera Installation Guide

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

Technical Overview CM-16 Climate Monitor. Get yours direct at:

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Loop-IP6702 TDMoEthernet

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

OC821 Iris Outdoor Camera Set-Up Guide. RC8221 Iris. Camera Set-Up Guide

SECTION DETECTION AND ALARM

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

IntesisBox KNX Mitsubishi Heavy Industries AC

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /01/02

IntesisBox Modbus Server - Mitsubishi Electric G50

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Emerson Smart Firewall

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

UPS Network Interface. Quick InstallationGuide

GPS NTP TIME SERVER Rack Version V2.2x

Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

Rack mounted telephone- and leased line modem for industrial applications

Loop-IP6510 Multiple WAN Router/Bridge

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

I STAR COMPUTER CO., LTD

Transcription:

ENVIROMUX-MINI with ENVIROMUX-T-3 Temperature Sensor Features & Applications Monitors Threats: Temperature Humidity Water Leakage Intrusion The Mini Server Environment Monitoring System monitors critical environmental conditions (such as temperature, humidity, and water leakage) that could destroy network components in your server room. When a sensor goes out of range of a configurable threshold, the system will notify you via email, SNMP traps, web-page alerts, a visual indicator (red LED), and SMS messages (via external GSM or 3G modem). Monitor and manage server room environmental conditions over IP. Integrates with various Open Source monitoring packages Nagios Sensors supported: and MRTG. 2 temperature/humidity sensors Optional industrial mini server environment monitoring system for 1 liquid detection sensor high temperature environments. This industrial system has the ability 4 digital inputs sensitive to contact closure to operate and monitor in harsh environments at high temperatures up Alerts are posted in message log, which is accessible through Web to 167 F (75 C). user interface. Add "-IND" to the end of the part number to specify this option. The log can be downloaded as a tab-delimited plain text file. Use in data centers, co-lo sites, web hosting facilities, telecom Flexible Zero-RU mounting. switching sites, POP sites, server closets, or any unmanned area that Mounting tabs included. needs to be monitored. Optional DIN mounting available. Temperature/Humidity Inputs Two female RJ45 connectors for connecting temperature sensors, humidity sensors and/or combined temperature/humidity sensors. Water Detection Cable Input One screw terminal pair for connecting liquid detection sensor. Additional water detection sensors can be connected to the dry contact closures. Output voltage: +5VDC. Current limited to 10mA Maximum resistance to close contact: 300K Ohm. Dry Contact Closures Four screw terminal pairs for connecting dry contact devices. Potential-free. Output voltage: +5VDC Current limited to 10mA Maximum resistance to close contact: 300K Ohm RS232 Port One female RJ45 connector for controlling a GSM modem. Supports 3-wire interface (Tx, Rx and GND) Used for flash upgrades (includes DB9F-RJ45F adapter). GSM modem supported: Teltonika WirelessCom/G10. 3G modem supported: NetComm N3GS003 MTBF 80,327 hrs. Specifications Ethernet Port One female RJ45 connector with LEDs. 10 BaseT Ethernet interface. Protocols HTTP, SNMP V1, SMTP, TCP/IP, UDP, DHCP Compatible with any SNMP management software. Operates and configures via HTTP web page. Supports Microsoft Internet Explorer 6.0 and higher. An IP address can be assigned to the ENVIROMUX-MINI automatically by a DHCP server. Generates SNMP traps, email alerts, and syslog messages. Email alerts can be sent to three addresses. Up to four users can access the Web interface simultaneously. Dimensions WxDxH (in.): 5.6x2x2 Regulatory Approvals ENVIROMUX-MINI: CE, UL, cul, RoHS ENVIROMUX-MINI-IND: CE, UL, cul, RoHS Power 110 or 220 VAC at 50 or 60 Hz via AC adapter. Power consumption: 5W Use the PWR-48V-5V1A DC-DC power converter to install the ENVIROMUX-MINI in a Telecom environment. 1

ENVIROMUX-T-xx Control Methods Configuration can be done over the Internet/LAN via Web page. Front Panel Interface LEDs indicate the following: Fault (red) lights up if a sensor goes out of range of a configurable threshold. Power (green) lights up when the device is powered/all clear. Web Interface Supports Internet Explorer 6.0 and higher, Firefox 1.5 and higher, Netscape 9, Safari 1.3 and higher for MAC, and Safari 3.0 and higher for PC. Configure sensor s thresholds, alarm methods, formats of alerts, and system data log. View/edit sensors current values, thresholds and alert statuses. All sensors connected to the ENVIROMUX-MINI can be viewed on one summary page. User configurable settings allow sensors to return to normal status when alert condition clears, without manually acknowledging/dismissing the alert. View/edit entries stored in the system data log. The log can be downloaded as a tab-delimited plain text file. Configure IP information (address, subnet mask, default gateway, DNS, etc.), user administrative settings, and data logging settings. Up to four users can access the web page at one time. WAP Mobile Summary Page View summary page on WAP 2.0 compatible devices (smartphones, PDAs, cell phones, etc.) Supports Blackberry Software 4.2 and higher. Supports iphones using Safari 3.0 and higher. Summary page lists all connected sensors' current values and alert statuses. Temperature Sensor Applications from 32 F to 104 F (0ºC to 40ºC). Accurate to within ±1.35 F (±0.75ºC). Environmental Sensors Configuration and Cable Illustration Temperature Sensor, Extended Range ENVIROMUX-T-IND-xx DIN Rail Mounting Option ENVIROMUX-MINI-D with optional DIN rail mounting for industrial applications For use with ENVIROMUX-MINI-IND. Applications from 32 F to 167 F (0ºC and 75ºC). Accurate to within ±2.25 F (±1.25ºC). 330.562.1999 Worldwide fax sales@ntigo.com www.networktechinc.com 2005, 2014 NTI All rights reserved 2

Temperature/Humidity Combination Sensor ENVIROMUX-TRH-xx ENVIROMUX-LDx-y ENVIROMUX-2W-xx Liquid Detection Sensor For warning of flooding. 100% waterproof electronics. Detects any conductive liquid. Puddle: 0.6" diameter. Detects liquid depth >0.1". Available water sensor cable (x) lengths: 1/10/50/100/200/400/600/ 800/1000 feet. Available 2-wire cable (y) lengths: 5/10/20/50/100 feet. Sensor Cables Environmental Sensors (continued) Applications from 32 F to 104 F (0ºC and 40ºC) and 20% to 80% relative humidity. Accurate to within ±1.35 F (±0.75ºC) and ±5% relative humidity. 2-wire sensor cable. Use to connect dry contact sensors to the ENVIROMUX-MINI. Available lengths (ft): 3/6/10/25/50/100, UL ENVIROMUX-RH-xx ENVIROMUX-SDS-PA ENVIROMUX-CMD-P Humidity Sensor Applications from 20% to 80% relative humidity at temperatures between 0ºC and 40ºC. Accurate to within ±5% relative humidity. Smoke Detection Sensor For warning of smoke. Built-in 135 F (57 C) thermal heat sensor. Photoelectric smoke detector. Regulatory approvals: UL Carbon Monoxide Detector Continuous air monitoring. Pre-set alarm points alert at: 70 ppm after 60 to 240 minutes 150 ppm after 10 to 50 minutes 400 ppm after 4 to 15 minutes Flush or surface mount. Test functionality of electrochemical CO sensing cell. LED indicators for operation status and system test. Regulatory approvals: UL 3

ENVIROMUX-M-DCS ENVIROMUX-TDS Door Contact Sensor Monitors access with a magnetic bridge sensor, which responds to any magnetic material (no special inserts necessary). Can also be used for monitoring side wall and covers. For normally closed circuit connection. 2-wire interface; screw terminal Wide actuating gap, about 1". Dimensions WxDxH (in): 0.5x0.5x2 (Switch), 0.5x0.5x2 (Magnet). Ceiling Mount Infrared Motion Detector ENVIROMUX-IMD-CMP ENVIROMUX-GBS-P Detects movement across the detection field. 360 detection pattern. 113 conical detection angle from ceiling. 36' diameter protection when mounted 12' high. Provides substantial immunity to false alarms caused by environmental disturbances. Good RFI protection Glass Break Detection Sensor Acoustically detects the cracking of glass. Adjustable sensitivity. Tamper Switch Sends activation signal when tamper switch is released. Normally closed contact when depressed. Dimensions (in): inner diameter: 0.8, outer diameter: 0.9, height: 2.9 2-wire interface. Motion/Intrusion Sensors (Continued) Sensors ENVIROMUX-IMD-P ENVIROMUX-IMD-MWP ENVIROMUX-EBS Infrared Motion Detector Registers movement in the area covered. Condition display via LED. Provides immunity from common-mode signals such as the effect of strong hot or cold air currents, variation in ambient temperature, background radiation and acoustic noise. 24 dual-element detection zones for long, mid and short range protections. Good RFI protection. Mini Infrared Motion Detector Detects movement across the detection field. Provides substantial immunity to false alarms caused by environmental disturbances. Good RFI protection. Dimensions WxDxH (in): 2.2x1.2x2.9 Emergency / Panic Button Sends activation signal when button is pressed. For normally closed or normally open circuit connections. 2-wire interface. Dimensions WxDxH (in): 0.4x0.9x3 330.562.1999 Worldwide fax sales@ntigo.com www.networktechinc.com 2005, 2014 NTI All rights reserved 4

PWR-48V-5V1A Power Over Ethernet Adapter Enables ENVIROMUX-MINI to be powered over Ethernet connection. Eliminate the need to place ethernetenabled devices near power outlets, giving more freedom of placement. Supply Power and Data up to 300 feet using standard Ethernet cabling. ENVIROMUX-POE Outputs Power on an attached DC power cable, and Data on an attached Ethernet cable. Ethernet Pin Usage: Data: 1,2,3,6 Power: 4,5,7,8 No tools or software necessary for installation. Overload and short circuit protection. Standards: 802.3af Dimensions WxDxH (in): 3x3.25x1.5 Maximum power output: 5VDC @ 2.4A., FCC, CE Power Converter Use the PWR-48V-5V1A power converter to install the ENVIROMUX- MINI in a Telecom environment. Accepts 36~72VDC (48 VDC nominal). Accepts positive or negative polarity. Outputs +5VDC and can handle 1A load. 3-pole detachable screw terminal for connecting 48V input. 2.1x5.5mm male DC power jack. Dimensions WxDxH (in): 1.8x2.1x1 Power Sensors & Accessories ENVIROMUX-ACVD-515M ENVIROMUX-ACVD-515 ENVIROMUX-ACVD-C14M ENVIROMUX-ACVD-C14 AC Voltage Detector Measurement range: detects voltage from 50 to 250 VAC. Measurement indication: Alarm or Normal. Sensor type: open/closed contact switch. Attached 3-foot power cord. ENVIROMUX-ACVD-515M: Standard US 120V 15A NEMA 5-15 plug (When using with ENVIROMUX-MINI that was purchased before 11/1/2008, use part number ENVIROMUX-ACVD-515) ENVIROMUX-ACVD-C14M: Universal 250V IEC C14 socket (When using with ENVIROMUX- MINI that was purchased before 11/1/2008, use part number ENVIROMUX-ACVD-C14). DC Voltage Detector Measurement range: detects voltage from 24-36 VDC. Contacts remain closed between 26-36 VDC Contacts open when monitored ENVIROMUX-DCVD-24V-M voltage drops below 24 VDC Measurement indication: Alarm or Normal. Sensor type: open/closed contact switch. Includes 6-foot 2-wire cable to connect to the ENVIROMUX-MINI. Attached 3-foot power cord with tinned leads on 3 wires. For use with ENVIROMUX-MINI purchased on or after 11/1/2007. 5