Modular three-phase UPS system. PowerLine DPA kva Full power for industrial applications

Similar documents
Product catalog ABB UPS products and solutions Power protection for critical infrastructures

Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA

Phase Modular Finally the benefits of Modular ups are for all

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

4.0 UPS dedicated to ICT for unmatched energy savings

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

RIELLO ELETTRONICA. Master HP

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Thyristor-controlled power supplies and battery chargers

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

MGE Galaxy /200/250/300/400/500 kva Power efficiency for business continuity

Conceptpower DPA kva. True modular UPS system for critical applications. Modular Three-phase UPS system

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work

Chloride 80-NET from 60 to 500 kw. Secure Power for Mission Critical Applications

ABB PSPS Erich Steinmann; Generator control-2013

Galaxy VM. Three-phase power protection. schneider-electric.com

Technical Specification Kohler PW 5000/TP

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

PowerGem Pro Uninterruptible Power Supply

Re-defining the utility-scale inverter

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Power protection for data centers

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Liebert NXC from 10 to 200 kva

User s Manual Before using the inverter, you need to read and save the safety instructions.

ABB central inverters PVS to 1000 kw

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

MAJORSINE Power Inverter

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Square D Model 6 Motor Control Centers

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

Standardization and modularity as the foundation of data center UPS infrastructure

Online UPS. PowerWalker VFI 1000R/1U

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Eaton 93PM UPS Where aesthetics meet intelligence.

OZW30. Central Unit SYNERGYR

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Product Information Fire alarm panel 8000 C

Low Voltage Products

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

LAP ENERGIA PARA DATACENTERS

TLE Series. Product Description kva / 400Vac / S1 KEY BENEFIT APPLICATIONS FEATURES

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

SNMP Web Management. User s Manual For SNMP Web Card/Box

Protect. UPS Solutions for large Data centers

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Eaton UPS kVA. Energía. 20 kva/18 kw and 30 kva/27 kw 0.9 power factor. True double-conversion online UPS.

Galaxy 7000: Unitary Specification guide: Single UPS, three-phase, 160 to 500 kva

Real-time Video Monitoring Increases the Efficiency of SCADA Process Management

UPS system for emergency lighting and smoke extraction

Eaton 93PM UPS Efficient. Scalable. Innovative.

IPSIP M series-m Modular Data Center

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

PowerValue TM. Compact protection for power supply For Continous Power Protection Availability

SolarMax P series The power package for residential solar plants

HUAWEI TECHNOLOGIES CO., LTD. Huawei IDS2000-S Small Modular Data Center Solution

S-series DC to DC Power Supply

TMS TANK MANAGEMENT SYSTEM

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

Tender Technical Specification. For Three phase UPS, on line double conversion (VFI) 30 kva 30 kw

Temperature & Humidity SMS Alert Controller

Technical data UNIBLOCK UBSF

PCS0100en Persy Control Services B.V. Netherlands

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

User Manual 1K/2K/3K Online UPS

UNINTERRUPTIBLE POWER SUPPLY (UPS)


Smart-UPS 3 Phase And MGE Galaxy 3500

TOSHIBA G /100/160/225 kva

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

Photovoltaic Solar Energy Unit EESFB

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

NC-12 Modbus Application

The UPS for the highest security in industry and data centres

Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理. Schneider Electric - Division - Name Date

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

Number 1 in efficiency

Repeaters and Mimics Data Sheet

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers

Transcription:

Modular three-phase UPS system PowerLine DPA 20 120 kva Full power for industrial applications

Smooth power in rough places For many industries, the consequences of electrical power loss can be disastrous: Production lines may have to go through a complex and costly restart; expensive product may be ruined; valuable production time can be lost; process equipment can be damaged; and safety issues may arise. Because a reliable supply of clean power usually cannot be guaranteed by the grid, ABB s PowerLine DPA UPS (uninterruptible power supplies) makes sure that the operation of industrial applications keeps running continuously as it should. PowerLine DPA is an online double conversion UPS and makes the advantages of ABB s unique modular UPS architecture available for locations that are usually rough on electronic equipment. PowerLine DPA is based on ABB s Decentralized Parallel Architecture (DPA) that ensures the very best UPS design in terms of availability, flexibility, cost and ease of use. DPA the very best UPS design With DPA, the UPS is modularized and each module has all the hardware and software needed for autonomous operation: rectifier, inverter, battery converter, static bypass switch, backfeed protection, control logic, display, and mimic diagram for monitoring and control. A module s output is not affected by failures elsewhere in the UPS. If one module is lost, the others take up its load. In other words, a multimodule system is fault tolerant and there are no single points of failure. Rectifier input Bypass input UPS module Control logic display Its robust design is suitable for industrial plant environments that have a variety of temperatures, dust, moisture and corrosive contaminants. The PowerLine DPA is designed to have a design life of 15 years. UPS module UPS module Control logic display Control logic display Output to the critical load Each UPS module has all the hardware and software it needs for autonomous operation; there are no shared critical elements. 2 PowerLine DPA ABB UPS systems

High serviceability One major advantage of DPA is that the modules can be swapped online, ie, removed or inserted without the need to power down or transfer to raw mains supply and without risk to the critical load. This unique aspect of modularity directly addresses continuous uptime requirements, significantly reduces MTTR (mean time to repair), reduces inventory levels of specialist spare parts and simplifies system upgrades. Modularity pays off too when it comes to serviceability: local service personnel do not need special skills, visiting service engineers spend less time on site, and any risks of data or production loss are minimized. An anti-condensation heater, lifting eyelets, dust filters, IP42 protection, halogen-free cables and cold start capability are some of PowerLine DPA s other features that are designed specifically for deployment in demanding industrial situations. The Powerline DPA is engineered to comply with projectspecific requirements. Its pre-configured options, tailored for industry, allow agile implementations with short lead times. The solution delivered is well documented for both the operational and the maintenance crew. The robust UPS Survivability is crucial, so particular attention has been paid to physical robustness. PowerLine DPA s IP31-rated protection can easily cope with dust, water condensation, excessive humidity (up to 95 percent), corrosive air contamination and rough manhandling. The UPS is designed to operate in a temperature range of 5 to +45 C. High priority has been given to safety and PowerLine DPA features a high degree of protection for users and maintenance staff. The device s compliance with the relevant standards IEC/EN 62040-1 for general and safety aspects, IEC/EN 62040-2 for EMC and IEC/EN 62040-3 for performance and test has been verified. All sort of transformers are available to meet customer voltage requirements and electrical isolation. In addition, PowerLine DPA has a high overload capacity and robust short-circuit capability, and is available with rated powers of 20 to 120 kva. With input and output (three-phase) voltages in the range 220 to 415 VAC the UPS requires no onerous electrical installation considerations and is straightforward to service. ABB UPS systems PowerLine DPA 3

Tough meets rough A UPS for rough conditions The guarantee of a continuous supply of clean power for their critical operations has become an essential prerequisite for the success of many enterprises. The PowerLine DPA UPS, designed to withstand the rigors of rough industrial environments, can provide this guarantee. PowerLine DPA s modular architecture makes it simple to service and because its online swapping attributes mean it never has to be switched off (it is designed to run up to 15 years continuously), first-class availability is achieved. Applications The PowerLine DPA UPS is ideal for ensuring a constant supply of good-quality power to industrial automation systems such as SCADAs, DCSs, etc. as well as the broad range of ancillary systems commonly found in the manufacturing and process industries such as those for sensors, valves, meters, data concentrators, emergency lighting, fire and gas monitors, telecoms and security. Other low-power and medium-power (up to 120 kva) applications are also supported, such as motors, pumps, etc. For industrial applications with heavier power demands, ABB s PCS100 product line has a selection of suitable solutions. In the area of transportation, the Powerline DPA UPS is perfect for supporting critical infrastructure such as rail control and signaling systems, paging and information distribution systems as well as the emergency lighting systems that are often mandatory in the transport network. Rail control & signaling system Paging & Information system Control & Automation system Lighting system Instrumentation / sensor and valves Telcom system Security systems Industrial Infrastructure 4 PowerLine DPA ABB UPS systems

Remote monitoring In a power fail situation, it is important for all relevant personnel to be quickly and fully informed of the system status. For this reason, the PowerLine DPA UPS can be supplied with relay boards and a network management card that provide connection to a DCS (distributed control system) or SCADA (supervisory control and data acquisition) system via SNMP, Modbus TCP or Modbus RS 485. These interfaces allow: Environmental monitoring Extensive alarm handling and dispatching Redundant UPS monitoring Integration of PowerLine DPA into multivendor and multiplatform environments The supply of UPS data to Web applications Connectivity via interfaces such as Modbus and SNMP allows the UPS to be part of a network that enables industrial production systems to exchange information and interact. The remote monitoring services makes UPS data available throughout the entire value chain and supply chain in real time. A presence on the network enhances the overall capabilities of data acquisition, operations, maintenance and advanced service. Local control and metering are provided via a HMI (humanmachine interface) consisting of graphical display showing the UPS mimic diagram, UPS operating status (normal, battery and bypass), and programmable alarms. Battery bank Most industrial processes will draw substantial amounts of power from a UPS. Therefore, PowerLine DPA is able to work with valve-regulated lead-acid (VLRA) or NiCad batteries to support autonomy times up to 10 h. Fast recharging is also catered for to get the UPS battery bank back up to operational levels as quickly as possible. ABB UPS systems PowerLine DPA 5

PowerLine DPA Technical specification General data System power range 20 120 kw Nominal power / frame 20 kw 40 kw 60 kw 80 kw 100 kw 120 kw Number of UPS modules 1 2 3 Output power factor 1.0 Topology Online double conversion UPS configuration Single, parallel-redundant, dual UPS type Modular (Decentralized Parallel Architecture) Input Nominal input voltage 3 380/220 V + N, 3 400/230 V + N, 3 415/240 V + N (others on request) Voltage tolerance For loads <100% ( 15%, +10%), <80% ( 20%, +10%), <60% ( 30%, +10%) (referred to 3 400 / 230 V) Input distortion THDi 4% Frequency 50 or 60 (selectable) Power factor 0.99 Output Rated output voltage 3 380/220 V, 3 400/230 V, 3 415/240 V (others on request) Voltage distortion (referred to 3 400/230 V) <2.5% Frequency 50 Hz or 60 Hz Overload capability 150% 1 min, 125% 10 min Output short capability 2.7 Inom Unbalanced load 100% (all three phases regulated independently) Crest factor 3 : 1 (load supported) Efficiency Overall efficiency / transformerless Up to 96% In eco-mode configuration 98% Environment Storage temperature 25 C to +70 C Operating temperature 5 C to +45 C Humidity 5% to 95% without condensation Altitude configuration 1000 m without derating Communications HMI Graphical display for control and metering, 8 programmable alarm indications Relay contactors 8 in / 9 out programmable relays LCD On system level HMI with graphical display and alarm indications; on module level service control interface LEDs LED for notification and alarm Communication ports USB, RS-232, SNMP slot, potential-free contacts Electrical / Mechanical Degree of protection IP31, IP42 (optional) Color RAL 7035 Cable entry Bottom, Top (optional) Wiring Halogen free cable Operating and maintenance access Front access Ventilation Forced ventilation with monitored fans Battery Battery type VLRA / NiCd Autonomy According to customer s requirement Standards Safety IEC / EN 62040-1 Electromagnetic compatibility (EMC) IEC / EN 62040-2 Performance IEC / EN 62040-3 Product certification CE Manufacturing ISO 9001:2008, ISO 14001:2004, OHSAS18001 Weight, dimensions Weight (with modules / without transformers) Up to 550 kg Up to 650 kg Up to 850 kg Dimensions w h d (mm) 800 2200 800 mm 1200 2200 800 mm 1600 2200 800 mm 6 PowerLine DPA ABB UPS systems

PowerLine DPA Product features Water protection roof Modular UPS modules Output protection Power module service panel MBS Input/bypass protection Communication interfaces Air filter with dust filter (optional) lncoming terminals N+1 redundant ventilation fans Input/output/bypass transformer (optional) Available models Cabinet type PowerLine DPA 20 40 PowerLine DPA 60 80 PowerLine DPA 100 120 Number of modules 1 2 3 Dimension w h d 800 2200 800 mm 1200 2200 800 mm 1600 2200 800 mm Weight in kg (without transformers) Up to 550 kg Up to 650 kg Up to 850 kg UPS cabinet configuration 3ph online double conversion UPS Decentralized Parallel Architecture Housed in an industrial metal enclosure, IP31, RAL 7035, bottom cable entry Halogen free cable Forced ventilation with monitored fans Input, bypass and battery protection Manual bypass switch Integrated back-feed protection HMI interface with graphical display, control push keys, UPS operating status indication and programmable alarm section Communication interfaces: Relay board with 9 programmable outputs and 8 inputs, RS-232 and USB ports Options Input, output, bypass aluminum transformer Customized input & output voltages Ingress protection IP42 Top cable entry Redundant fan monitoring (N+1) Tropicalization and anti-corrosion protection for electrical boards Anti-condensator heater Lifting eyes Control and monitoring (ModBus RS-485, ModBus TCP/IP, SNMP) Battery temperature sensor Cold start Redundant configuration ABB UPS systems PowerLine DPA 7

Contact us www.abb.com/ups ups.sales@ch.abb.com Copyright 2016 ABB. All rights reserved. Specifications subject to change without notice. 4NWP101121R0001 EN