Flexi. The perfect friction fit for framed constructions

Similar documents
Rockwool Flexi Insulation Application Guide

Rockwool Cladding Roll

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

ProRox Slabs (formerly known as RW slabs)

ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Multi-layer Insulation Blanket for Roofs

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Timber Frame Walls Rethinking Construction

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Fire Barrier Systems. For inhibiting the spread of fire and smoke in concealed spaces

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

The Pocket Guide To Insulation August 2013

Steel-framed Walls. Insulation

The Kingspan Insulation Price List 1 st January 2013

PB301 July Lightweight Building Solutions. Bushfire Protection.

Rev Code of Practice. SIP Technology.

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

How To Certify The Scottsdale Construction System

Energy Company Obligation (ECO): Technical Monitoring Questions

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Innovation - High performance roof, wall and floor insulation board. delivering better performance

sound reduction systems for commercial, educational and industrial environments

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

Module 3.7. Thermal bridging

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

Providing protection in construction

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

SIP (STRUCTURAL INSULATED PANEL)

Hardrock Dual Density Range

Hardrock Dual Density Range

KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION

Lightweight Partition Design for Residential and Commercial Buildings

Building Control Guidance Note

Report Number BTC 17755F

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION

Composite Panel Firewall Systems

Mineral fibreglass insulation

Fiberglas, Exterior Wall Thermal Insulation

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

European Organisation for Technical Approvals

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

H-Stud Area Separation Wall System

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

Post and Beam Construction

Sealfire W1000 Compound. (2 references for the same product) Fire Stopping and Sealing Product: Penetration Seals

Section 2.3. Flat Roofs. Warm deck single ply membrane. Warm deck single ply membrane. Warm deck built-up felt/ mastic asphalt. Protected membrane

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction

EcoTouch Insulation with PureFiber Technology

Manual lifting and handling

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

GYPSUM AREA SEPARATION FIREWALLS GA

Low Energy Low Carbon Buildings

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

British Gypsum Guide to Timber Frame Construction. March 1998

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

Internal wall insulation in existing housing

European Technical Approval ETA 13/0526

Renovating Your Basement

NordicWood. Scandinavian Timber Frame Buildings

FIRE RATED GLAZING System Guide

How To Repair A Boat Landing Deck With A Boat Bed

2014 British Columbia Building Code Changes

FireWall. High performance fireresistant. FireWall.

FLAT ROOF INSULATION INSULATION ROOFING FLAT. Quick Guide. Quick Guide. Insulation. EcoTherm Insulation UK Sales Team. Insulation

Building Regulations for the Conservation of Fuel and Power

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

Low Energy Low Carbon Buildings

Including. Rubershield-Pro. Breather Membrane

Architectural composite panels

Chapter 2 Basis of design and materials

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

IMPACT DAMAGE RESISTANT WALL SYSTEMS

fire separating walls #2

The WANZ Guide to Window Installation

PRESTRESSED CONCRETE FLOORING BEAMS

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

Unbeatable energy efficient glass curtain wall system

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

Building Control Guidance Note

The Real Value of Space

Acoustic. Publication date June

Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February Foundation Heave Protection

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

Transcription:

1 CONSTRUCTION TYPE: TIMBER AND METAL FRAME The perfect friction fit for framed constructions is a unique, flexi-edged insulation product, specifically developed using patented technology for a fast and easy, perfect friction fit between timber and metal frame systems. The following NBS clauses include : p10:140, p10:210, p10:230, p10:240, p10:250, k10:115, k10:125, k10:145, k10:155, k10:165, k10:185, k10:420, k11:215, k11:225, k11:235, k11:245, k20:150, k20:160, m10:290, m13:260

2 CONSTRUCTION TYPE: TIMBER AND METAL FRAME FlexI slabs ensure essential tight fitting for thermal and acoustic integrity between frames in walls, partitions, floors and roofs, without the need for cutting or waste. Made from renewable volcanic rock, they are extremely fire resistant and significantly reduce the carbon footprint of a building. Advantages Outstanding thermal, acoustic and fire properties FlexI edge offers accurate fit to all widths Multi-application; fits all typical metal and timber stud spacing Wide range of thicknesses No waste Easy to handle and install without gaps Fire classification A1 Can be used as a full fill solution in timberframe party walls to achieve zero effective U-value within SAP 2012 Product properties and design Dimensions suits standard stud and floor joist spacings and is available in the following sized slabs: Installation guidance Slabs are light and easy to cut to any shape with a sharp knife. Ensuring a perfect insulation fit is essential to maintain the thermal and acoustic integrity of the wall. Typical softwood timber moisture contents can range between 6-30%, dependant on exposure to the elements. As a rule of thumb, timber will expand 1% for every 4% of moisture content. If insulation is installed when timber has high moisture content, it can result in a potential 6 mm vertical void on each side, when the timber dries out. expands into this void, ensuring thermal and acoustic integrity, whilst rigid insulations may leave a 6 mm gap, or even fall out. Where studs or joists are spaced at 400mm centres, 400mm wide should be used. is also fast and easy to friction fit between floor joists from below, prior to fixing the plasterboard ceiling. Once installed does not require any maintenance. Length x width (mm) *Standard available thicknesses (mm) 1200 x 600 50, 60, 70, 90, 100, 120, 140, 180 & 200 1200 x 400 50, 100 & 140 Packaging is supplied palletised, compression packed in polyethylene bags, protected by a weatherproof covering allowing it to be stored outside. However the FlexI slabs should not be left permanently exposed to the elements.

3 CONSTRUCTION TYPE: TIMBER AND METAL FRAME Thermal applications timber frame walls The additional thermal benefits offered by using high performance (HP) breather membranes (BM) and vapour control layers (VCL) over standard membranes are also shown in the tables below. Effective thermal resistance (R-values) comparisons used for external cavities are as follows: a) Standard BM =0.18m 2 /K/W: or b) Tyvek Reflex BM= 0.540m 2 /K/W c) Glidevale TF200 Thermo = 0.77m 2 /K/W Effective thermal resistance (R-values) comparisons used for service void cavities are as follows: a) Standard vcl =0.18m 2 /K/W: or b) DuPont AirGuard vcl = 0.680m 2 /K/W c) Glidevale Protect VC Foil = 0.78m 2 /K/W Construction 1: Cold frame with no service void Timber frame cavity wall, standard construction, insulated with between studs. Breather membrane (see options below) between stud Construction 2: Cold frame with service void Timber frame cavity wall with separate 25mm battened service void, between studs: Timber frame construction 2 - with service void U-value FLEXI (mm) Stud depth between stud Breather membrane (see options below) Vapour control layer (VCL) (see options below) 25mm service zone between battens Breather membrane type Std Tyvek Reflex Protect TF200 Thermo Service void VCL options and types Std Tyvek Air- Guard Protect VC Foil 0.27 140 140 3 3 0.21 140 140 3 3 0.20 140 140 3 3 0.22 180 184 3 3 0.18 180 184 3 3 0.17 180 184 3 3 0.19 200 220 3 3 0.17 200 220 3 3 0.16 200 220 3 3 Standard vapour control layer (VCL) Timber frame construction 1 U-value No service void FLEXI (mm) Stud depth Breather membrane type Std Tyvek Reflex Protect TF200 Thermo 0.28 140 140 3 0.25 140 140 3 0.24 140 140 3 0.23 180 184 3 0.21 180 184 3 0.20 180 184 3 0.20 200 220 3 0.19 200 220 3 0.18 200 220 3

4 CONSTRUCTION TYPE: TIMBER AND METAL FRAME Construction 3: Warm/Hybrid frame (with no service void) Warm/hybrid timber frame cavity wall with Rockwool insulation between studs and 50mm Rockwool HP Partial Fill, fixed to face of OSB over breather membrane. Construction 4: Single timber frame with cladding External cladding or tile hanging, 50mm ROCKWOOL between outer vertical battens, breather membrane on 9mm OSB. ROCKWOOL between timber studs, standard vapour control layer, 12.5mm plasterboard finish. 50mm ROCKWOOL HP Partial Fill Cavity Slab Standard vapour control layer (VCL) Standard breather membrane Breather membrane standard 50mm between counter battens OSB between studs Standard vapour control layer (VCL) Construction 3 warm/hybrid timber frame No service void (Standard BM & VCL) U-value RW P/fill over OSB in frame Stud depth 0.25 50mm 90mm 89 0.19 50 140 140 0.17 50 180 184 0.15 50 200 220 Construction 4 : Timber frame with cladding and 50mm between battens U-value w/m 2 K FLEXI in frame Stud depth between battens 0.27 50 100 100 0.22 50 140 140 0.18 50 180 184 Note the U-values shown in table 3 above can be further enhanced upon by the inclusion of a service void see construction 3a table below Construction 3a: Timber frame warm/hybrid frame construction (with service void) As construction 3 above, but with additional 25mm battened service void Construction 3a warm/hybrid timber frame - with service void Service void VCL options and types U-value RW P/ fill over OSB in frame Stud depth Std Tyvek Protect AirGuard VC Foil 0.24 50 90 89 3 0.22 50 90 140 3 0.21 50 90 90 3 0.19 50 140 140 3 0.17 50 140 140 3 0.17 50 140 140 3 0.16 50 180 184 3 0.15 50 180 184 3 0.15 50 180 184 3

5 CONSTRUCTION TYPE: TIMBER AND METAL FRAME Thermal applications floors Suspended timber floor is installed between joists, supported by polypropylene netting or breather membrane. The insulation should be fitted as close as is practical to the underside of floor deck to avoid any air gaps: 100 mm to fit tightly between the joists and supported by the mesh. Lay new floor of either (a) 19 mm flooring grade t&g chipboard or (b) square edged boards with a layer of 3mm hardboard above or below the boards. 100mm ROCKWOOL FLEXI supported by wire mesh 195x47mm gs grade softwood joists at 400mm centres 19mm T&G floor boarding between joists Perimeter edge insulation between joist and wall Continuous run of 25mm ø wire mesh stapled to sides of joist and laid over ceiling 9.5mm plasterboard (or lath and plaster in good condition) Acoustic applications walls Product FLEXI U-value 0.25 0.22 0.20 0.18 thickness thickness thickness thickness P/A ratio (mm) (mm) (mm) (mm) 0.4 120 140 150 180 0.5 120 140 160 200 0.6 120 140 180 200 0.8-1.0 140 140 180 200 The P/A ratio is determined by dividing the total of the exposed perimeter length of the floor by the area of the floor. Fire protection: Upgrading existing timber floor to achieve one hour fire resistance 1 hour fire resistant floor based on fire test to BS476: Part 21 using. Remove existing floor boards and install a continuous run of 25mm ø chicken wire mesh across the whole floor. Form the mesh so that it follows the profile of the joists and the top face of the ceiling lining. works in two distinct ways to reduce noise, either by impeding the transmission of sound through the structure, or by absorbing sound at the surface. Acoustic and thermal insulation for timber frame party walls to help reduce Party wall bypass Heat loss via Separating party cavity walls Building Regulations Approved Documents L1A & L2A of England and Wales and Section 6 of Scotland s Building standards have recognised that where party cavity-walls between connected buildings are untreated, considerable heat can escape through them. Minimising heat loss from party walls. Rockwool has a range of solutions to help eliminate the heat loss from timber frame party walls. Extensive site trials have demonstrated that the U-value for a party wall can potentially be reduced to zero if the cavity of a timber frame party wall is fully filled with insulation and effective edge sealing (such as Rockwool PWCB) is applied around the perimeter edges of the party wall cavity (further details about Rockwool PWCB can be found in the Rockwool FirePro CAVITY BARRIER data sheet).

6 CONSTRUCTION TYPE: TIMBER AND METAL FRAME Robust Details: Separating timber framed walls Robust Details reference E-WT-1 Without sheathing board Twin timber frames (for use in conjunction with timber frame dwellings and apartments) Robust Details reference E-WT-2 Separating wall - timber frame With sheathing board Twin timber frames (for use in conjunction with timber framed dwellings and apartments) Rockwool SoundPro robust detail guidance specification Wall width: a minimum of 240mm between inner faces of wall linings and a 50mm gap between the two frames. Wall lining: 2 or more layers of gypsum-based board (total nominal mass per unit area 22kg/m²) both sides. : a minimum of 60mm in both wall frames. Thermal Regulations: Minimising heat loss via party walls To assist in achieving a zero U-value for thermal applications we would recommend the following: 1. Fully fill the depth of the studs in both wall frames with 90mm (this assumes the depth of the stud to be 89mm). 2. Fully fill the cavity space between the wall frames with 60mm batt (this assumes the cavity width to be 60mm). Rockwool SoundPro robust detail guidance specification Wall width: a minimum of 240mm between inner faces of wall linings and a 50mm gap between studs. Wall lining: 2 or more layers of gypsum-based board (total nominal mass per unit area 22kg/m²) both sides. : a minimum of 60mm in both wall frames. Thermal Regulations: Minimising heat loss via party walls To assist in achieving a zero U-value for thermal applications we would recommend the following: 1. Use a minimum thickness of 60mm between studs in each frame. 2. Fully fill the cavity space between the wall panels with *60mm batt (*Note for this construction type, the thickness of insulation used to fully fill the cavity should be 10mm wider than the as built cavity width. eg. use 60mm in 50mm Cavities or 70mm in a 60mm Cavity.

7 CONSTRUCTION TYPE: TIMBER AND METAL FRAME Robust Details reference E-WS-1 Separating wall - steel frame Twin metal frames for use in lightweight steel frame houses and flats/apartments (for use in conjunction with light steel framed dwellings and apartments). Acoustic applications partitions will provide both acoustic and fire benefits when used in partitions. Lightweight domestic timber stud partition: meeting Approved Document E2 (domestic internal partitions) Solution 1 - Timber frame Studs: 38 75 timber studs @ 600mm centres Facings: 1 layer 12.5mm acoustic rated plasterboard (11 kg/m²) each side Insulation: a minimum of 50mm of Rockwool Rockwool SoundPro robust detail guidance specification Wall width: a minimum of 200mm between inner faces of wall linings Wall lining: 2 or more layers of gypsum-based board (total nominal mass per unit area 22kg/m²) both sides : a minimum of 50mm fully filling the cavity between frames (this thickness will vary pending as built cavity width). Please note: The steel frame profiles shown are indicative only. Other profiles are acceptable. This robust detail is only suitable for use in lightweight steel frame houses and flats/apartments. 38 x 75mm timber studs at 600mm centres 50 x 600mm wide 12.5mm acoustic rated plasterboard both sides Results Weighted sound reduction (Rw db) 40 Fire resistance (minutes) 30 Max height (metres) 3 Nominal wall thickness (millimetres) 100

8 CONSTRUCTION TYPE: TIMBER AND METAL FRAME Solution 2 - Metal frame Lightweight domestic metal stud Studs: 50mm metal studs @ 600mm centres Facings: 1 layer of 12.5mm standard plasterboard (8kg/m²) each side Insulation: a minimum of 50mm of Rockwool Enhanced performance (timber frame) Typical office partition adjacent to factory Studs: 38 75 timber studs @ 600mm centres Facings: 2 layers of 12.5 mm standard plasterboard (16kg/m²) each side Insulation: a minimum of 50mm of Rockwool 50x600mm wide 38x75mm timber studs at 600mm centres 50x600mm wide 12.5mm standard plasterboard both sides 12.5mm 2 layers of standard plasterboard both sides Results Weighted sound reduction (Rw db) 41 Fire resistance (minutes) 30 Max height (metres) 2.5 Nominal wall thickness (millimetres) 75 Results Weighted sound reduction (Rw db) 46 Fire resistance (minutes) 60 Max height (metres) 3 Nominal wall thickness (millimetres) 125

9 CONSTRUCTION TYPE: TIMBER AND METAL FRAME Enhanced performance (metal frame): schools, offices and public buildings: NBS Plus Clause K10:115, K10:125 Studs: 70mm metal studs @ 600mm centres Facings: 2 layers of 15.0mm acoustic rated plasterboard (26kg/m²) each side Insulation: a minimum of 70mm of Rockwool 70x600mm wide Two layers of 15mm acoustic rated plasterboard both sides Results Weighted sound reduction (Rw db) 57 Fire resistance (minutes) 90 Max height (metres) 4.6 Nominal wall thickness (millimetres) 130 Alternative Rockwool systems for Approved Document E compliance New build separating timber floor The following Rockwool solutions have the potential to meet the requirements set out in Part E Section 3 and provide a minimum fire resistance of 60 minutes. Airborne: Rw 54 db (Rw 66-12 Ctr) Impact: Lnw 54 db Test Report ref. L03 272 & 273 Rockwool floor type 18mm of tongue and groove flooring grade chipboard 15mm acoustic rated plasterboard with a minimum mass 12.5 kg/m² mass per unit area 50mm of Rockwool Rockfloor resilient layer 15mm of OSB on 200 50mm timber joists @ 400mm centres 100mm of between joists Resilient bars fixed at right angles to joists @ 400mm centres Ceiling finish: 2 layers of 15mm acoustic rated plasterboard (26 kg/m²) Pre-completion site testing required on site For details of this acoustic solution with downlights, refer to SoundPro brochure, Section E1 (New build), page 3, solution 6.

10 CONSTRUCTION TYPE: TIMBER AND METAL FRAME Internal floors Rockwool system for compliance with ADE Section 5 internal floors, within the same dwellings Timber joist internal floor (domestic internal floor) To meet part E2: Rw 40 db Test Report ref. L03 264 & 265 18mm of tongue and groove flooring grade chipboard with a mass per unit area of 12.4 kg/m² Timber joists @ 400mm centres 100mm of between joists A single layer of standard 12.5mm plasterboard ceiling with a mass per unit area of 8kg/m² Existing ceiling should be upgraded to 20kg/m². If the existing ceiling is of lath & plaster it should be retained, providing it satisfies Part B Fire Safety. (if in doubt then, underdraw the ceiling with an additional layer of 12.5mm fire rated plasterboard and screw into the joists) Pre-completion site testing Acoustic applications separating walls (material change of use) ADE Section 4 ADE construction guidance specifications for wall treatment 1: existing solid masonry wall with independent panel(s); Acoustic applications separating floors (material change of use) ADE Section 4 ADE Construction guidance specifications for material change of use separating timber floor treatment 2: Platform floor with absorbent material: NBS Plus Clause K11:215, 225, 235 & 245 A minimum of 2 layers of board material to provide minimum a total mass of 25kg/m², spot bonded together with joints staggered (eg 18mm of tongue and groove flooring grade chipboard and 19mm of plasterboard plank) 25mm (min) Rockwool Rockfloor resilient layer laid on The floating layer to be loose laid over the Rockfloor Existing floor deck on existing timber floor joists 100mm of A minimum of 100mm of existing solid masonry wall, plastered on both faces Independent timber or steel studs. A minimum 10mm gap to be maintained between the frame and the existing wall 50mm of between studs 2 layers of plasterboard at a minimum of 20kg/m² (approximately equal to 2 15 mm layers) Avoid flanking transmission: seal perimeter edges of new plasterboard with tape or Rockwool Acoustic Sealant If the existing masonry wall is not plastered or is less than 100mm thick then independent panels should be applied to both sides Pre-completion site testing

11 CONSTRUCTION TYPE: TIMBER AND METAL FRAME Standards and quality approvals Fire classification achieves a reaction to fire classification of A1, as defined in EN13501-1. Product performance Thermal Performance has a thermal conductivity of 0.038W/mK and 0.035W/mK at 140 mm thickness and above. Ordering : Please quote thickness, width and area required. Rockwool Rockfloor: Please quote thickness and area required. Rockwool HP Partial Fill Slabs: Please quote thickness and area required. ROCKWOOL properties As an environmentally conscious company, ROCKWOOL promotes the sustainable production and use of insulation and is committed to a continuous process of environmental improvement. Health and Safety The safety of ROCKWOOL stone wool is confirmed by current UK and Republic of Ireland health & safety regulations and EU directive 97/69/EC: ROCKWOOL fibres are not classified as a possible human carcinogen. A Material Safety Data Sheet is available and can be downloaded from www.rockwool.co.uk to assist in the preparation of risk assessments, as required by the Control of Substances Hazardous to Health Regulations (COSHH). Environment Made from a renewable and plentiful naturally occuring resource, Rockwool insulation saves fuel costs and energy in use and relies on trapped air for its thermal properties. ROCKWOOL insulation does not contain (and has never contained) gases that have ozone depletion potential (ODP) or global warming potential (GWP). ROCKWOOL is approximately 97% recyclable. For waste Rockwool material that may be generated during installation or at end of life, we are happy to discuss the individual requirements of contractors and users considering returning these materials to our factory for recycling. Interested? All ROCKWOOL products provide outstanding thermal protection as well as four added benefits: Fire resistance For further details visit our website at www.rockwool.co.uk or phone ROCKWOOL Technical Solutions on 0871 222 1780. Copyright ROCKWOOL April 2014 Acoustic comfort Sustainable materials Durability ROCKWOOL Limited Pencoed Bridgend CF35 6NY info@rockwool.co.uk www.rockwool.co.uk ROCKWOOL Limited reserves the right to alter or amend the specification of products without notice as our policy is one of constant improvement. The information contained in this data sheet is believed to be correct at the date of publication. Whilst ROCKWOOL will endeavour to keep its publications up to date, readers will appreciate that between publications there may be pertinent changes in the law, or other developments affecting the accuracy of the information contained in this data sheet. The above applications do not necessarily represent an exhaustive list of applications for ROCKWOOL FLEXI. ROCKWOOL Limited does not accept responsibility for the consequences of using ROCKWOOL FLEXI in applications different from those described within this data sheet. Expert advice should be sought where such different applications are contemplated, or where the extent of any listed application is in doubt.