GIS BASED URBAN SCALE AIR POLLUTION MODELING WITHIN A GERMAN-BULGARIAN TWINNING PROJECT

Similar documents
usage of these types of fuels with production price far higher then diesel and petrol, is also a measure. We can say that in Bulgaria there are

PROKAS (As at: April 1999, last changes )... Calculation method to determine traffic induced pollution levels

Comparison of PM10 and SO 2 Concentrations in the Cities Located at the Mediterranean Coast of Turkey

How To Reduce No 2 Emissions In Nordic Cities

EMISSIONS OF AIR POLLUTANTS IN THE UK, 1970 TO 2014

Energy from Waste Combined Heat and Power Facility, North Yard, Devonport. Community Ambient Air Quality Monitoring Programme Report Quarter 4, 2015

Revealing the costs of air pollution from industrial facilities in Europe a summary for policymakers

Controlling Dust. Dr Claire Holman. London Pollution Study Group 11 th February Brook Cottage Consultants

UFIPOLNET. Street detailed calculation of the air quality in Saxony. Landesamt für Umwelt und Geologie

Emissions estimate from forest fires: methodology, software and European case studies

A STUDY OF ENVIRONMENTAL BENEFITS OF INDUSTRIAL INTEGRATION

Layman Report. Stirling Power Station. Mini CHP with longlife Stirling engine. Mayer & Cie. GmbH & Co. P.O. Box D Albstadt

The design of the Romanian national air quality monitoring network

A GUIDANCE NOTE ON THE BEST PRACTICABLE MEANS FOR ELECTRICITY WORKS BPM 7/1 (2014)

EN A new unified testing and approval scheme for automated measuring systems

Costs of air pollution from European industrial facilities an updated assessment

Ground Power Unit (GPU) Exhaust Emissions at Zurich Airport

Emission inventory system in Latvia

Linkoping is in Sweden, where winters are cold

Air Quality: Public Health Impacts and Local Actions

Federal Ministry for Environment, Nature Conservation and Nuclear Safety

AN AMBIENT AIR QUALITY MONITORING NETWORK FOR BUENOS AIRES CITY

Air quality and biomass installations. A briefing for local authorities

The Ambient Air Monitoring System

SEATTLE STEAM COMPANY FREQUENTLY ASKED QUESTIONS

Temporary Batch Plants

SUMMARY OF THE IMPACT ASSESSMENT

The Introduction of Euro 5 and Euro 6 Emissions Regulations for Light Passenger and Commercial Vehicles

2/ Analysis of the origin of the PM10 concentration levels in Belgian towns

C E R C. Cambridge Environmental Research Consultants. Emissions Reduction Scenarios for the City of London Corporation. Final report.

Biomethane production and its use in captive fleets. Lille Metropole Experience

Project No. (FKZ) /05 UBA-FB Summary. by Dr. Sonja Martens Dr. Bernd Eggers Thorsten Evertz Golder Associates GmbH, Celle

QUALITY ASSURANCE AND IMPROVEMENT OF MICRO-SCALE METEOROLOGICAL MODELS

2) Relevance for environmental policy ) Data sources and reporting ) References at the international level... 6

Proposed Terms of Reference for EIA studies

Transactions on Ecology and the Environment vol 15, 1997 WIT Press, ISSN

Site Identification No.: AAO Application No.:

The Challenges In Monitoring And Control Of Indoor Air Pollution Due To Combustion In Kitchens In Urban And Rural Areas

Testing and Assessment Protocol Release 2.0. Programme Manager Dipl.-Ing. (FH) Sonja Schmidt ADAC Technik Zentrum

4.09 THE IMPORTANCE OF BUILDING DOWNWASH IN ASSESSING THE NEED TO HEIGHTEN STACKS OF EXISTING SMALL AND MEDIUM SIZED INDUSTRIES

Emission Facts. The amount of pollution that a vehicle emits and the rate at which

Birmingham City University / Students Union Aspects and Impacts Register. Waste. Impacts description

SIX REASONS TO DRY BIOGAS To A LOW DEWPOINT BEFORE COMBUSTION IN A CHP ENGINE STEVEN SCOTT MARKET DEVELOPMENT MANAGER ALTERNATIVE ENERGIES

Impacts of air pollution on human health, ecosystems and cultural heritage

Update of LCI Background Data Exemplified for the German Steam Coal Supply Chain

LANDFILL GAS TO ENERGY- COMBINED ENGINE AND ORC-PROCESS

Metrological features of a beta absorption particulate air monitor operating with wireless communication system

The Terms of reference (ToR) for conducting Rapid EIA study for the proposed project is described below:

Development of a World-wide Harmonised Heavy-duty Engine Emissions Test Cycle

The Introduction of Euro IV and Euro V Emissions Directive for Heavy Vehicles

Waste to Energy in Düsseldorf. for a clean city.

C E R C. Cambridge Environmental Research Consultants. Air Quality Modelling for the London Borough of Islington. Final Report. 14 th January 2015

Impact of the climate change discussion on the

Verona, ottobre 2013!

Berlin s Air Quality Strategy: measures and expected effects

Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants

Hub for London High Level Qualitative Assessment of Air Quality Compliance Risks for a Hub Airport in the Thames Outer Estuary: Technical Note

Policy on Monitoring of Stack Emissions to Air at EPA Licensed Sites

Air Quality Monitoring at Dublin Airport: Annual Report HSSE Department

Aggregate Handling And Storage Piles General

Physical flow accounts: principles and general concepts

Emissions and Modelling Remapping London s Air pollution

36.0 EMERGENCY REGULATIONS

The Greenhouse Gas Protocol

2 nd National Workshop on Global Fuel Economy Initiative (GFEI) in Mauritius. Ministry of Environment and Sustainable Development 27 th November 2014

Inventory of existing methodologies and tools

PHARMACEUTICAL AND CHEMICAL WASTE MANAGEMENT

Energy Efficiency and Smart Cities in Germany Status & Perspectives

BOILER OPERATORS HANDBOOK

Comprehensive emissions per capita for industrialised countries

Guide to UK Air Pollution Information Resources June 2014

ATTAINMENT PROJECTIONS

Abstract. 1 Introduction. 2 Sampling locations

Impact of altitude on the fuel consumption of a gasoline passenger car

In 2013, the Spanish economy emits million tonnes of greenhouse effect gases, 7.8% less than in 2012

Environmetric Data Interpretation to Assess Surface Water Quality

Environment Impact Assessment of Thermal Power Plant for Sustainable Development

EN Type Approval & Certification of AMS (QAL1)

Effect of Self-Heat Circulation on VOCs Decomposition in Regenerative Thermal Oxidizer

PROPOSAL AIR POLLUTION: A PROJECT MONITORING CURRENT AIR POLLUTION LEVELS AND PROVIDING EDUCATION IN AND AROUND SCHOOLS IN CAMDEN

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 and CEN/TS 15675:2007

How To Conduct An Environmental Impact Assessment

Journal of the University of A. Chemical Lenchev, J. Technology Ninov, I. Grancharov and Metallurgy, 43, 3, 2008,

Estimated emissions and CO2 savings deriving from adoption of in-place recycling techniques for road pavements

VEHICLE INSPECTION FOR REDUCING EMISSION

Hackney Biomass Boiler Information Request Form

NGV / CNG Market Finland Jussi Vainikka, Gasum Oy Malmö, Sweden, /05/ /04/2012, IEE/08/545/SI ,

Exhaust emissions from vehicles with Euro 6/VI technology

Canada-United States Emissions Cap and Trading Feasibility Study: Consistency Versus Flexibility


RESOURCE EFFICIENCY SCOREBOARD DATA CENTRE ON NATURAL RESOURCES

Assessment of Air Emissions Martin Marietta Materials Facilities on Highway 34, Weld County, Colorado Project No.:

Peaks of Electric and Wind Power - Where to go? Power-to-Liquid (Silicon Fire-Methanol)

Monitoring of air pollution spread on the car-free day in the city of Veszprém

AIR QUALITY IN PARIS REGION 2012

10 Nuclear Power Reactors Figure 10.1

Biogas as transportation fuel

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Smart Grids initiative. Electrical Engineering Institute of Renewable Energies Dipl.-Wirtsch.-Ing. Alexander von Scheven 1

Cambridge Environmental Research Consultants Ltd

Transcription:

Contr. to 17 th Intl. Conf. Informatics for Environmental Protection, Cottbus, Sept 24-26, 2003. GIS BASED URBAN SCALE AIR POLLUTION MODELING WITHIN A GERMAN-BULGARIAN TWINNING PROJECT Helmut Lorentz 1, Jürgen Friebertshaeuser 2 and Achim Lohmeyer 3 1 Lohmeyer Consulting Engineers GmbH & Co. KG, Radebeul, GERMANY 2 German pre-accession-advisor in the Ministry of Environment & Water, Sofia, BULGARIA 3 Lohmeyer Consulting Engineers GmbH & Co. KG, Karlsruhe, GERMANY Keywords: dispersion modeling, Geographical Information System (GIS), ArcView, Air Quality Directives INTRODUCTION In the course of the enlargement of the European Union the accession countries must adapt the EU Directives. By the project Support of Air Quality Management at Local Level (BG99EN02) the EU supported under the management of the Bulgarian and German Ministries of Environment the analysis and the assessment of the air pollutant concentrations in Bulgaria. Aim of the project was to support the Bulgarian administrations in the implementation of the Ambient Air Quality Framework Directive and the corresponding 1st Daughter Directive. For the execution of that task, a model was needed to explain the present air pollution concentrations, to analyse the causes of these concentrations and to estimate the effects of emission reductions. It should be user friendly, being able to cope with the usual groups of air pollutant sources as streets, stacks, domestic heating etc., should be able to work on the basis of the available input data and additionally be usable to digitize and display the input and output data on the basis of maps. The German partner (Fed. Ministry of Environment) looked for such a model in Germany and finally decided to use the system SEL- MA GIS, which was developed and is in daily operational use by Lohmeyer Consulting Engineers GmbH & Co. KG. The model was chosen also because of its special features for treatment of PM10 sources from vehicle traffic. SOME CRITERIA FOR THE SELECTION OF THE MODEL The selection of an operational flow and dispersion model depends on the conditions within the area under investigation, on the availability and the quality of the input data, on the experience of the user, the available financial resources and the purpose, the results are needed for. For flow and dispersion modelling for example the following criteria have to be considered: - What scale is considered? Is the concentration to be determined within single street canyons or is the aim to get more or less an overlook over the concentrations in a region, say in a 500m by 500m grid. - Are there topographical features, modifying the atmospheric flow by obstacles like hills or by valley drainage flows and thus influencing the dispersion of the pollutants? - What is the accuracy and the availability of the input data. In case there are only deficient and low quality input data, no sophisticated flow and dispersion model needs to be applied. - What is the experience of the user? Sophisticated models are only good for experienced users. And of course additional points have to be considered as: Is the handling of the system user friendly? Is it for example integrated into a GIS to allow easy handling and control of the input and of the results? Is it in operational use for some time and thus hopefully more or less debugged? Does it contain an acceptable handbook and is it supported by a professional hotline, not only covering the handling at the computer but also to discuss how to proceed with the task on the basis of the abilities of the model?

CONTENT OF THE MODELING SYSTEM SELMA GIS The chosen SELMA GIS modelling system (System for Calculation and Representation of Air Pollutant Concentrations) is an air pollutant dispersion modeling and handling system. It is able to provide the concentrations and the statistical parameters, needed for example for the comparison to the limit values, set by Directive 1999/30/EG. For improved handling of the data SELMA GIS contains digitizing and display modules, based on the Geographical Information System ArcView (V 3.2a). The system accesses under its surface the modules of the following models: DIGIstreet, for digitalizing complex street networks incl. allocation of traffic parameters, EMIstreet, for calculating the air pollutant emissions of these streets. It makes use of the exhaust pipe emission factors, determined for Bulgaria by RWTÜV Fahrzeug GmbH (2001). It additionally includes the PM10 emissions caused by dust re-suspension and abrasion of tires, vehicle components and the wear of the street surface as described by Düring et al. (2002), DIGIpoint, for the creation of the receptor points, PROKAS_V (Gaussian plume model) for the calculation of the additional street concentrations and PROKAS_B (MISKAM-based dispersion library) for calculating the additional street concentrations in built up streets, TALBO (at that time the official German regulatory Gaussian plume model) incl. DIGItalbo, for digitalizing the parameters of point and area sources, as well as for calculation of the additional concentrations caused by emissions from these sources, DIGIsum, for calculation of the total pollution on the basis of each individual calculated additional concentration and the background concentration. It also contains a NO/NO2 conversion module and modules to calculate the statistical parameters of the concentrations, needed for an assessment under the EU Air Quality Directives. System requirements for SELMA GIS are a Windows 98 or 2000. A Pentium III processor and a minimum of 128 RAM are recommended. APPLICATION IN BULGARIA a) General Information about the project In a first step, the city of Pernik (ca. 30 km south-west of Sofia) was chosen for a pilot study. An air pollutant-monitoring program was executed for PM10, SO2, NO2 and lead. The locations were chosen to cover the influence of the major local sources from stack emissions to domestic heating and traffic as well as the local background concentration. The results led to the conclusion that the limit values for PM10 are significantly exceeded, whereas the limit values for SO2, NO2 and lead were kept in 2001. The annual mean concentrations found are higher than in Western Europe, but comparable to other hot spots in Bulgaria (e.g. Sofia) and other cities in Middle and Eastern Europe. The analysis of the reasons of exceedance for PM10 based on the measurement data alone did not provide clear conclusions. But with the help of the dispersion modeling an estimation of the share of the different emission sources and the regional background concentration for the local ambient air quality situation was possible. b) Some aspects of the calculations The dispersion calculation was done including the emissions of traffic on the main roads, domestic heating, stack and fugitive emissions from industrial plants and dust emissions from local ash and waste deposits. For use for the emission modeling, traffic counts were executed and for the dispersion calculation meteorological measurements were done. The domestic heating emission factors were derived from factors used in Germany and other countries (see Bibliography) and taking into account the special characteristics of the fuel used locally. The emission factors of the dust emissions from area sources like ash and waste deposits were derived from factors and formulas published by US-EPA (AP 42) and VDI guidelines 3790, 2&3.

The calculations were done for a fixed 250 m x 250 m grid in the inhabited area of the city and increased to a 500 m x 500 m grid in the vicinity plus all locations of the field measurements. The calculation was done for the contributions of the different sources, additionally the total concentration as sum of these contributions plus the regional background concentration was determined. For comparison of the results of the modelling and the monitoring see Moldenhauer et al. ( 2002). c) Example of the results Fig. 1 displays the calculated annual mean concentrations of PM10, resulting from the Pernic local sources. They increase versus the centre of the city, several areas with concentrations larger 20 µg/m³ (red squares) are displayed. It can be seen, that in this case they are all close to the major roads. Fig. 2 gives one of the results of the calculations, used for the systematic search for the origin of the concentrations. The share of the different source groups can be detected. Fig. 1: PM10 in 2005. Annual mean concentrations resulting from local sources, i.e without regional background concentration. d) Conclusions for Pernik With the help of the dispersion modeling a detailed analysis of the share of the different sources and the regional background concentration for the local ambient air quality was possible. Additionally the modeling showed that the concentrations of SO2 and NO2 are in a range where exceedances of the limit values cannot be excluded for sure. At the monitoring sites there were no exceedances, but as only one site covers the required measurement period of one year for these pollutants it can not be ruled out that this monitoring might not have taken place at the location where the highest concentrations occur. The ambient air quality (AAQ) for NO2 is mostly influenced by the road emissions. The highest values were found near streets with high traffic volume and a high share of heavy-duty vehicles. The AAQ situation for SO2 is strongly influenced by domestic heating and by emissions of the local district heating plant (DHP). The concentrations for lead are dominated by traffic emissions (leaded fuel) and emissions of the local steel plant.

Fig. 2: PM10 in 2005. Origin of pollution from local sources. Annual mean. Without regional background concentration. The AAQ situation for PM10 is most complex and determined by several sources in the city as well as by the regional background concentration. All these sources contribute to the exceedance of the limit values. The highest contribution for the locally caused PM10 concentrations seems to be due to domestic heating. The DHP, the steel work, the vehicle traffic and the erosion from dusty areas including ash deposits also contribute significantly to the PM10 concentration, but to a different degree in the different areas of the city. Another main result of the modeling was the conclusion that a high regional background concentration of PM10 significantly contributes to the PM10 concentrations in Pernik. This regional background concentration is in the magnitude of 30 to 35 µg/m 3 (annual mean) thus already close to the limit value. Therefore, actions for reducing the local PM10 emissions are very important, but will probably not be sufficient to reach the limit values. FUTURE PROSPECTS The twinning project ended in September 2002. It helped to improve the knowledge about the levels of the air pollutant concentrations and their causes. The Bulgarian authorities plan to go on with the implementation of an air quality management system, aiming on the development of emission reduction strategies. BIBLIOGRAPHY Duering, I, E. Schulze, J. Jacob, W. Reichenbaecher and A. Lohmeyer, 2002: Determination of the non exhaust pipe PM10 emissions of roads for practical air quality modeling. 8 th International Conference on "Harmonisation within atmospheric dispersion modelling for regulatory purposes", 14.-17.10.2002, Sofia, Bulgaria. Demetra Ltd. ISBN: 954-9526-12-7. EC-Directive 1999/30/EC: Council Directive 1999/30/EC of 22 April 1999 relating to limit values for sulphur dioxide, nitrogen dioxide and oxides of nitrogen, particulate matter and lead in the ambient air. Official Journal of the EC of 29.6.1996, No L 163/41. Modeling System SELMA GIS, see www.sfi-software.de/selmaenglish.htm

Moldenhauer, A., Friebertshäuser, J., Kostov, A., Tzenkova, A., Ivancheva, J., Lorentz, H., Lohmeyer, A.,2002: Air pollution modelling in the Bulgarian-German Twinning Projekt Support of air quality management at local level.8 th Intl. Conf. on "Harmonisation within atmospheric dispersion modelling for regulatory purposes", 14.-17.10.2002, Sofia, Bulgaria. Demetra Ltd. ISBN: 954-9526-12-7 RAINS modelling system: (http://www.iiasa.ac.at/~rains/pm/docs/documentation.html) RWTÜV Fahrzeug GmbH, 2001: Adaptation of German Emissionfactor model MOBILEV to Bulgaria. User Manual, developed for Umweltbundesamt, Germany UK emission factor database for domestic heating www.naei.org.uk/emissions/index.php US-EPA: (http://www.epa.gov) AP42 compilation of air pollutant emission factors VDI 3790, Blatt 2, 2000: Emissions of gases, odors and dusts from diffuse sources, Landfills, and VDI 3790, Blatt 3, 1999: Emissions of gases, odours and dusts from diffuse sources, Storage, transshipment and transportation of bulk materials. VDI/DIN-Handbuch Reinhaltung der Luft, Band 1b.