REDWALL. MegaRed 180 Dual Range detector Model LRP 180QH Installation and Set-up Instructions. (Please keep for future reference)

Similar documents
REDWALL-V adjustment procedures guide

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

FIRERAY 2000 Installation Guide

Shunt lock function 3066

Building Technologies

Passive Infrared Motion Detector 5420/90. Installation Instructions

500r+ Installation and User Guide

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Stove Guard Kit User Manual

AX-100TFR/AX-200 TFR INSTALLATION INSTRUCTIONS INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR.

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

90 Degree PIR Wireless Security Sensor. Installation Instructions 5420/90F

Floodlight Range Installation Guide

Radiant Temperature Sensor TY7321

ACTIVE 5 ENGINEERING MANUAL

16/32 Channel 1U Rack Mount CCTV Power Supply

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

60W PIR BULKHEAD LIGHT SLB88-Black/SLW89-White INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

5W LED Energy Saver PIR Bulkhead

2400W PIR LIGHT C O N T R O L L E R Cat No. SLW2400

Mobile Data Power Model: MDP-25

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

WD-AMX Water Detection Controllers

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

TS510 & TS500. Installation & User Guide. Compatible Equipment

NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide

9448 Installation and User Guide

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

HERZ-Thermal Actuators

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

OPL BASIC. Dosing System for Professional Laundry machines. Contents

9452/9453 Installation and User Guide

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Wireless Home Security Alarm System AM 500

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

CB200W Water Leak Detection Panel Application Guide

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Cross-beam scanning system to detect slim objects. 100 mm in

LED Security Spotlight User Manual

ALARMLINE ANALOGUE Linear Heat Detection System

SYSTEM 4C. C R H Electronics Design

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Triple Waveband Infra-Red Flame Detection

Self Monitoring Power Supply (BPSM)

12 Volt 30 Amp Digital Solar Charge Controller

Laserlyte-Flex Alignment System

SECURITY SYSTEM ADP-CAN

AUTODIALLER / QUICKDIALLER - SA132

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Secure Keypads for access control

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

SYSTEM 45. C R H Electronics Design

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Treasure Cove Metal Detector

IS3016A Passive Infrared Motion Sensor with Anti-Mask - Installation Instructions

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4

PART 1 - INTRODUCTION...

WORLDWIDE. GW400k SERIES MAINTENANCE MANUAL PROVEN PERIMETER PROTECTION

Drayton Digistat +2RF/+3RF

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

SMART SENSOR COLLECTION


User s Manual Before using the inverter, you need to read and save the safety instructions.

Wireless Alarm system s manual

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Analogue addressable devices

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

2M IR Mini Dome Quick Installation Guide

LUCCI AIRFUSION QUEST II CEILING FAN

Product Specification instalert Rapid Messenger Variable Message Sign

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Intrusion Outdoor Protection Perimeter

GLOLAB Two Wire Stepper Motor Positioner

FIREDEX Conventional Fire Panels

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Page 162. Page 154. Page 158 Page 146. Page 157. Page 152. Page 160. Page 149. Page 159. Page 156. Page 150

12 Volt Lighting Products

Modular I/O System Analog and Digital Interface Modules

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

SPR-5 FOUR SECTOR COMPOS I TE CONTROL UN I T.

D/N VANDAL RES. VARI-FOCAL DOME CAMERA

SECTION DETECTION AND ALARM

Fire. The Fire Installers Mate. A guide to fire alarm systems design

AN ESTIMATION OF A PASSIVE INFRA-RED SENSOR'S PROBABILITY OF DETECTION

WIRELESS HOME ALARM SYSTEM (WHA1)

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Installing Cisco TelePresence MX200 G2 - Wheel Base

Transcription:

REDWALL MegaRed 180 Dual Range detector Model LRP 180QH Installation and Set-up Instructions (Please keep for future reference) DESCRIPTION Model LRP 180QH is designed to detect human movement at ranges of up to 180 metres. The rugged housing contains two separate detectors. One detector is similar to the popular REDWALL LRP 100Q quad sensor which has a detection range up to 100 metres. The other detector is also a quad sensor system with a long focal length optical system specifically designed to detect movement at ranges between 80 and 180 metres. The LRP 180QH is ideal for use with CCTV surveillance systems which have multi-cameras or domes with pan, tilt and zoom facilities. The two outputs (near and far) may be used to automatically activate camera pan or zoom controls to precisely locate an intruder over the full detection range. Alternatively, the two outputs may be used to direct an operator to a specific area of interest or to activate local floodlighting. The LRP 180QH comprises two units, the detector head and the control unit which contains three relays for near, far and tamper signalling. The control unit may be located remote from the detector head, for instance at a control/monitoring area, or may be located close to the detector or camera where direct automatic pan or zoom is used. Connection between head and control unit is 4-core screen cable which may be up to 1400 metres. (See cable chart Fig. 6). Alarm signalling between the detector head and the control unit is by means of simple line current monitoring which is highly immune to radio and electrical interference. Fig. 1 shows the coverage patterns of the two detectors. At the recommended mounting height of 8 feet (2.5 metres) there will be an area directly below the unit extending some 6 metres where an Passive Infrared 2M 3M 4M AT 30M AT 100M AT 180M NEAR DETECTOR PLAN VIEW FAR DETECTOR 0.5 FAR DETECTOR 8FEET 2.5M NEAR DETECTOR Fig. 1

detectors ultimate detection range will vary according to the background temperature and the size, speed and clothing of the intruder. The LRP 180QH is designed and tested to detect a normally clothed, normal size adult, moving at slow or medium walking pace across the zones. Variations in size and clothing, background temperature, speed and direction of motion may result in the ultimate detection range being less (or more) than 180 metres. Fig. 2 shows the schematic principles of the system. Note that both near and far systems use dual-channel signal processing and event-memory circuits which require intruder detection to occur in both channels within a time period in order to be accepted as an alarm condition. An alarm condition in either near or far systems sets the line interface to provide various levels of line current which are translated into relay activation at the control unit. An open-circuit (zero line current) or removal of the control unit lid will activate the tamper relay. QUAD SENSOR SIGNAL EVENT MEMORY NEAR DETECTOR LOGIC SUPPLY QUAD SENSOR SIGNAL SIGNAL EVENT MEMORY EVENT MEMORY LINE INTERFACE TWO CORE SIGNAL LINE TAMPER/FAULT RELAY NEAR DETECTOR RELAY FAR DETECTOR LOGIC FAR DETECTOR RELAY SIGNAL EVENT MEMORY MEGARED CONTROLLER MEGARED HEAD Fig. 2 INSTALLATION Important: The LRP 180QH contains fragile optical components and must be handled with care. Before installation, check that the unit is free from damage and that no loose objects are rattling around inside. When planning the location, remember that all PIR detectors respond best when the intruder crosses the zones. IF THE GROUND IS NOT LEVEL AND HAS DIPS, INTRUDERS MAY CROSS BELOW THE ZONES WHEN WALKING IN THESE DIPS AND NOT BE DETECTED. CAREFUL SYSTEM PLANNING IS STRONGLY RECOMMENDED. The detector head MUST be securely mounted on a firm vertical surface using all four holes in the wall bracket. It is recommended that the expansion bolts (supplied) be used when wall mounting. If the detector head or its mounting surface moves during high winds, false alarms may result. (Even a half degree movement left and right will mean that the furthest zones will pan over 3 metres.) The top surface of the head unit should be parallel with the ground. If the ground is level a spirit level may be used to set the head ready for walk-testing. (See Fig. 3+4) When fixing the control unit, fix to a vertical surface with the cable glands at the bottom.

RANGE ADJUSTMENT Fig. 3 Fig. 4 POWER ON LED FAR LED NEAR LED TAMPER LED Fig. 5 MR 240 CONTROL IMPORTANT IF ALL CABLES ARE AT MAX. PERMITTED RESISTANCE ENSURE THAT INPUT VOLTAGE AT TERMINALS IS NOT LESS THAN 11 VOLTS LRP 180QH DETECTOR MAX. RES. 20 OHMS (10 OHMS PER CONDUCTOR) RELAYS MAX. RES. 12 OHMS (6 OHMS PER CONDUCTOR) 12V (NOM) SUPPLY (11~16V DC) Cable Twin Max. Distance Cable Twin Max. Distance 7/02 120M 7/02 75M 16/02 250M 16/02 150M 24/02 400M 24/02 250M 0.5M 250M 0.5M 150M 1MM 550M 1MM 300M 1.5MM 800M 1.5MM 500M 2.5MM 1400M 2.5MM 850M Fig. 6

CONNECTIONS Fig. 5 shows the terminal layout of the control unit. The three relays provide voltage-free change-over (form C) (S.P.D.T.) contacts rated 1 Amp. at 30V MAX. WARNING!!! DO NOT CONNECT MAINS POWER TO ANY TERMINALS. If the control unit is located a long way from the head and heavy (1.5 or 2.5mm) cables are used, it is recommended that the cables are terminated in a separate junction box and smaller gauge cables are taken into the control unit terminals. The 12volt input should preferably be from a float maintained battery/power pack capable of providing at least 100mA. with less than 0.25volt p-p ripple. NOTE: The 12volt supply negative terminal of the control unit is connected to the case as is the negative terminal of the head input cable so the power supply negative will be grounded. Under normal quiescent conditions (no movement and control box lid fitted) all relays should be energised. Cutting or disconnecting the head cable will activate (de-energise) the tamper relay. Detection by the near (6-100M) detector will activate the near relay. Detection by the far (80-180M) detector will activate the far relay. Detection by both near and far detectors (mid-range) will activate the far relay only. (The far relay will override the near relay). Fig. 6 is a guide to maximum distances allowable for a selection of popular cable sizes. NOTE that the maximum allowable resistance between the head and control unit is 20 ohms (10 ohms per conductor) and the maximum resistance between the control unit and the D.C. power source is 12 ohms (6 ohms per conductor). INITIAL TESTING Double check that the power supply input is the correct polarity (negative on the right). The control unit has a shunt diode across the input terminals and the reverse connection will blow the power supply fuse (if fitted) or may damage the control unit if not fitted. With power applied, check that the voltage at the supply terminals is between 11.5 and 16volts. (with a float charged battery/power pack the voltage should be around 13.5V). If an oscilloscope is available, check that ripple is less than 0.25volt p-p. Check that the head signal cables are the correct way round (negative on the left) and that a voltage of between 9 and 12 is present. If no voltage is present, the head leads may be reversed. The supply LED should be lit. Allow at least 60 seconds for the detector head to settle. The relays and associated LED indicators may switch rapidly during this period. With no movement in the protective zones the near and far relays should be energised and the indicators out. The tamper relay and light will be in alarm, pressing the tamper switch extension should energise the relay and extinguish the light. If it does not, the head signal cable is open-circuit. Where the head is located some distance away from the control unit, a quick way of checking that the system is working is to connect a meter (set for 100 milliamps range) in series with the positive signal lead to the control unit terminal. When the system is first energised the head currents will fluctuate between 20 and 50 milliamps for some thirty seconds then should settle to around 7.5mA. Movement within the near zones should cause the current to rise to around 19mA. Movement within the far zones should register around 31mA and movement midway, with both detectors activated should register around 42mA. NOTE: Waving a hand close to the front of the detector may not cause an alarm because the hand will be out of focus. For initial system testing it is better to angle the head down and walk across the zones a few metres away.

RANGE SETTING USING THE AUDIO WALK-TESTER OPM-WT The OPM-WT converts the voltage fluctuations at the detector into a changing audio tone. The tone pitch rises and falls as a zone is crossed. When the unit trips into alarm, the tone pitch suddenly rises. If there is no further movement the unit will re-set after some 10 seconds and the tone drop back to a lower pitch. The OPM-WT has a switch allowing selection of either the near or far detector signals. It is plugged into the jack socket on the head underside next to the cable outlet. To avoid confusion, only one channel of the two dual channel processors are monitored. This means that crossing the zones one way may give a fluctuating tone followed by a trip, whereas crossing in the other direction may give a trip first. Where the control unit is located close to the detector head, both the walk-tester and the alarm LEDs may be observed. (See Fig. 7). Where the control unit is remotely located, the walk-tester is the main means to assist with alignment. If the control unit is remotely located and a walk-tester is not available, it is possible to observe the near and far alarm conditions by means of a milliamp meter connected in series with the red (+ve) signal cable. It is even possible to align the heads without any connection to the control unit by use of a 12volt battery and a milliamp meter. Fig. 8 shows this method and the chart shows the current flows to be expected for the various alarm conditions. The above method only shows alarm trip conditions, it cannot show background fluctuations of the sensor signals which may be excessive. The OPM-WT walk-tester is strongly recommended since it is easy to hear any fluctuations which may be caused by unwanted motion of the sensor or objects within the zones. It also clearly shows where the zone boundaries are and where the ultimate range of the zones are. NEAR LED POWER ON LED FAR LED TAMPER LED MEGARED HEAD CONTROL UNIT OPM-WT Fig. 7 QUIESCENT NEAR TRIPPED FAR TRIPPED BOTH TRIPPED 7.5 ma 19 ma 31 ma 42 ma MILLIAMPS MEGARED HEAD 12 VOLT BATTERY OPM-WT RED BLUE Fig. 8

FINAL ALIGNMENT The recommended procedure is as follows: - Check that the mounting bracket is firm then slacken the pan bolts and pan the head to the desired direction. Firmly tighten both bolts. - Slacken the two tilt bolts and adjust the range adjustment screw to ensure that the top surface of the head is parallel to the ground. - Assuming level horizontal ground, use a spirit level as shown in Fig. 3. - Unscrew the range screw 3 turns causing the head to tilt downwards. (See Fig. 4&9) - Plug in and switch the walk tester to far - Walk across the zones at progressively further distances until detection stops. - Raise the head by turning the range screw by 1/2 turn. - Repeat the cross walk until no detection. - Raise head and repeat until desired range is achieved. (NOTE that only small adjustments are required when the range reaches 100 metres or more). - Carefully tighten the two tilt bolts and lightly lock the range screw with the locknut, THEN RE-TEST AT MAXIMUM RANGE TO ENSURE THAT THE HEAD HAS NOT MOVED. Reverse the walk test procedure by crossing the zones progressively nearer the head until detection ceases, then switch walk-tester to near. Detection should occur to within 6 or 8 metres of the detector. WALK A B C D E A ADJUST HEAD UPWARDS B ADJUST HEAD UPWARDS C ADJUST HEAD UPWARDS D ADJUST HEAD UPWARDS E MAKE FINE ADJUSTMENTS 1/4 TURN MAX. MAINTENANCE In addition to regular walk-test, periodically check that the unit is firmly fixed to the mounting surface. Check the front windows for build-up of dust, sand, animal or insect debris and CAREFULLY REMOVE BY VACUUM OR BLOWING. AVOID RUBBING OR BRUSHING THE WINDOW MATERIAL. The frequency of these checks will depend on the environment, but should not be less than twice per year. The detector head is factory sealed and no attempt should be made to open it.

DIMENSIONS MEGARED HEAD 11.0 280 mm 8.8 223 mm 6.8 173 mm 5.5 140 mm 3.15 80 mm 2.38 60 mm CONTROL UNIT 4.9 125 mm 4.45 113.5 mm 2.3 58 mm 2.0 52 mm 3.15 80mm ACCESSORIES OPM-WT Audio Walk-tester for Mege Red and REDWAVE. LRP Mega Hood Sun/Snow Hood. LRP Mega Guard Cage.

Product Specification Sheet Model LRP-180QH Power Input 11-16VDC Current Draw 80mA (max) at 12VDC Detection Method Passive Infrared Range 180m x 4m (500' x 12') Detection zones 24 Zones, 6Quad Layers Mounting Height 2.5m (8') Alarm Period Approx. 2 sec Alarm Output Form C 30VDC 1A x 2 (Far, Near) Tamper Output N.C opens when cover removed 28VDC 0.1A Warm-up Period Approx. 60 sec Walk test Indication Visual : LED x 3 (Far, Near, Tamper) Audio : Sounder Available (OPM-WT) Optional Operating Temperature -40 to +60 C Weight Head : 4.7kg, Controller : 0.6kg IP Rating IP 65 Finish White (Powder Coated) NOTE These units are designed to detect movement of an intruder and activate an alarm control panel. Being only part of a complete alarm system,we cannot accept responsibility for any damages or other consequences resulting from an intrusion.these products conform to the EMC Directive 89/336 EEC. OPTEX CO., LTD. (JAPAN) OPTEX INCORPORATED (USA) OPTEX (EUROPE) LTD. (UK) OPTEX SECURITY SAS (FRANCE) OPTEX SECURITY SP.Z.O.O. (POLAND) (ISO 9001 Certified by LRQA) (ISO 14001 Certified by JET) 5-8-12 Ogoto Otsu,Shiga, 520-0101 Japan Tel :+81-77-579-8670 Fax:+81-77-579-8190 URL http://www.optex.co.jp/e 13661 Benson Ave.,Bldg.C Chino, CA 91710-5266 U.S.A. Tel: (909)993-5770 Fax:(909)628-5560 URL http://www.optexamerica.com (ISO 9001 Certified by NQA) Clivemont Road, Maidenhead, Berkshire, SL6 7BU UK Tel:+44-1628-631000 Fax:+44-1628-636311 http://www.optexeurope.com 475,Rue Piani 69780 Amberieux d Azergues France Tel:+33.4.37.55.50.50 Fax:+33.4.37.55.50.59 http://www.optex-security.com ul. Bitwy Warszawskiej 1920 r. 7B 02-366 Warszawa POLAND main:+48-22- 598-06-60 Fax:+48-22-598-06-61 No.59-1290-1 06,9-20