PLT. breaker-based transfer switch open, closed or soft transition amps. Features

Similar documents
GTEC transfer switch open transition

Transfer switch BTPC open, closed or delayed transition

How To Operate A Gec Transfer Switch Open Transition Amp Power Supply

PowerCommand Paralleling System Digital MasterControl

PowerCommand iwatch 100 Remote Network Monitoring

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

PowerCommand 3201 digital generator set control

PowerCommand 500/550 Remote Monitoring System

Gas Genset Controls. Genset Control Panel (GCP2) with PCS (PowerCommand Supervisor) Features. Description

Transfer Equipment Controls

Continuous Power... Continuous Protection

Diesel generator set C22D5T series

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

How To Test A Power Switch On A Power Supply

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

SWITCHGEAR. EGP Switchgear

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

SECTION VARIABLE FREQUENCY DRIVES

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Diesel Engine Driven Generators Page 1 of 6

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

ASCO SERIES 185 Power Transfer Switches

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

Automatic Transfer Switch Controller

PowerCommand iwatch 100

Digital generator set 1302 control kit

PowerCommand 1.1 control system

Zenith Controls ISO R-1000C 5/99

TOSHIBA G /100/160/225 kva

Data Center Power Systems

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

Spark-ignited generator set

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Secondary Unit Substations

POWER GENERATION.

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

ATC-300 Automatic Transfer Switch Controller

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Thyristor-controlled power supplies and battery chargers

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

Eaton Automatic Transfer Switches

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

Sentron Series Circuit Breakers

32VFD Variable Frequency Drives for Centrifugal Chillers

SUGGESTED SPECIFICATION for Service Entrance Automatic Transfer Switches

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Permissible ambient temperature Operation Storage, transport

Bypass transfer switch mechanisms

Limited Service Fire Pump Controllers Features

SECTION STATIC UNINTERRUPTIBLE POWER SUPPLY SYSTEM

reliable company...caterpillar

Generator Differential Relay Electrical Apparatus

Power Generation. Power Control PCL System Generator Set Control

Liebert NXL Power-Tie Controls

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

*.ppt 11/2/ :48 PM 1

INSTALLATION INSTRUCTIONS

Disturbance Recoder SPCR 8C27. Product Guide

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Circuit Breakers. Next Generation of Protection Capabilities

Guidelines for ATS selection: How to choose the right transfer solution for your power application.

Decision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

SECTION LOW VOLTAGE LIGHTING CONTROLS

Eaton s E-Series protective relay family

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Series TS Amp. Automatic Transfer Switches

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

Distribution Dry Type Transformers

Pow-R-Con Multi Function Control

4KVA/5KVA Parallel Installation Guide

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

Phase Modular Finally the benefits of Modular ups are for all

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Catalog. Arc Guard System TM TVOC-2

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

THERMAL MANAGEMENT SOLUTIONS

ABB PSPS Erich Steinmann; Generator control-2013

APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Transcription:

PLT breaker-based transfer switch open, closed or soft transition 800 3000 amps PLT breaker-based transfer switches are designed for operation and switching of electrical loads between utility power and standby generator sets. They are suitable for use in emergency, legally required, and optional standby applications. The switch monitors both power sources, signals generator set startup, automatically transfers power, and returns the load to the primary power source when the utility returns and stabilizes. Power transfer switching is accomplished using power circuit breakers with integral overcurrent protection and drawout functionality. The result is a system that is suitable for use in applications requiring selective coordination and a high level of serviceability, at moderate cost. Features Flexible operating modes: Models available for open transition (with programmed transition), momentary closed transition, soft load (ramping) closed transition. High short-time withstand current rating: UL 489 listed circuit breakers can withstand a fault condition for up to 60 cycles, facilitating selective coordination. Service entrance: Power breakers are available in a standard service entrance transfer switch configuration. PowerCommand control: A fully featured microprocessor-based control with digital display. Controls allow operator to enter settings and make adjustments to software-enabled features easily and accurately.

PLT 02 PLT breaker-based transfer switch Soft load: Closed transition with preprogrammed gradual ramping to minimize transients during transfer is available. Service entrance rated: With the optional ground fault sensor, PLT meets the UL standard for service entrance applications. InPower service tool: Facilitates simple, quick field configuration and troubleshooting. Protective relays: IEEE 86 lockout relay is standard. Multifunction relay is available as an option with closed transition configurations. Reverse power protective relay: protects the utility from reverse current flow (optional) Load power and load current monitoring: Measures load phase and neutral, current, power factor, real power (kw) and apparent power (kva). Warns of excessive neutral current resulting from unbalanced or nonlinear loads. Minimum current level detection is 3%. Three-phase monitoring: Monitors line to neutral voltage of all sources, for over/ under voltage, loss of phase, and over/under frequency. Robust control system design: Optically isolated logic inputs and isolation transformers for AC power inputs provide high-voltage surge protection. Communications capability: The transfer switch is capable of communicating with other transfer switches, SCADA-networked accessories, or Cummins Power Generation generators utilizing LonWorks protocol. Standard programmable time delays: Provides time delay start/stop, transfer and re-transfer functions, and programmed open transition. Warranty and service: Products are backed by a comprehensive warranty and a worldwide network of distributors with factorytrained service technicians. Exterior view of a PLT breaker-based transfer switch

PLT 03 Power circuit breakers PLT transfer switches utilize electricallyoperated drawout power air circuit breakers for the transfer of power from source to source. Power circuit breakers combine the durability of traditional automatic transfer switches with high withstand ratings. The circuit breaker can maintain service for up to 60 cycles during a fault condition. Square D Masterpact circuit breakers are electrically-operated with long, short and instantaneous trips. Breaker close and trip circuits are 24V DC. Breaker charging power is derived from the connected AC source. Breaker tripping causes that breaker s source to be considered failed. When the breaker is tripped, the control system initiates transfer to the alternate source. The control system logs this as a fault condition separate from a source failure. Breakers are bus-connected to load lugs with silver-plated copper bus. Bracing is per UL standards and rated at 100 ka. Drawout breaker configuration facilitates service and maintenance of the power transfer contacts without extended service interruptions. The circuit breaker can maintain service for up to 60 cycles during fault conditions, which simplifies selective coordination. Interior view of a PLT breaker-based transfer switch

PLT 04 Power command control PowerCommand controls are microprocessor based and developed specifically for automatic transfer switch operation. The control includes the features and options required for most applications. Flash memory stores the control settings. Contents of the memory are not lost even if power to the controller is lost. On-board battery maintains the real-time clock setting and the engine start time delay. Allows network communication with the controller to continue, where applicable. Control is field-configurable using the operator panel, and can be programmed by Cummins Power Generation service personnel using the InPower electronic service tool. Panels Basic indicator panel: Source available/connected LED indicators Test/exercise/bypass buttons Analog bar graph meter display: Standard Digital display: Standard Basic indicator panel Analog bar graph meter display Digital display Control functions Utility-to-genset applications Utility-to-utility applications Programmable genset exerciser: Eight events/schedules with or w/o load Date/time-stamped event recording: 50 events Software adjustable time delays: Engine start: 0 to 120 sec Transfer normal to emergency: 0 to 120 sec Re-transfer emergency to normal: 0 to 30 min Engine stop: 0 to 30 min Programmed transition: 0 to 60 sec Undervoltage sensing: 3-phase normal, 3-phase emergency Accuracy: ±2% Pickup: 85% to 98% of nominal voltage Dropout: 75% to 98% of pickup setting Dropout time delay: 0.1 to 1.0 sec Overvoltage sensing: 3-phase normal, 3-phase emergency Accuracy: ±2% Pickup: 95% to 99% of dropout setting Dropout: 105% to 135% of nominal voltage Dropout time delay: 0.5 to 120 sec Over/under frequency sensing: Normal and emergency Accuracy: ±0.05Hz Pickup: ±5% to ±20% of nominal frequency Dropout: ±1% beyond pickup Dropout time delay: 0.1 to 15.0 sec Voltage imbalance sensing: Dropout: 2% to 10% Pickup: 90% of dropout Time delay: 2.0 to 20.0 sec Phase rotation sensing: Time delay: 100 msec Loss of single phase detection Time delay: 100 msec Load sequencing: Optional with network communications module M031. Provides control for eight steps of load with and adjustable time delay for each step on transfer, re-transfer or both. Staging loads on in sequence helps minimize the required generator size.

PLT 05 PowerCommand control (continued) Time-delay functions Engine start: Prevents nuisance genset starts due to momentary power variation or loss Transfer normal to emergency: Allows genset to stabilize before application of load. Prevents power interruption if normal source variation or loss is momentary. Allows staggered transfer of loads in multiple transfer switch systems. Re-transfer emergency to normal: Allows the utility to stabilize before re-transfer of load. Prevents needless power interruption if return of normal source is momentary. Allows staggered transfer of loads in multiple transfer switch systems. Engine stop: Maintains availability of the genset for immediate reconnection if the normal source fails shortly after transfer. Allows gradual genset cool-down by running unloaded. Elevator pre-transfer signal: Requires optional relay signal module (M023). Delays transfer for pre-set interval of 0-60 seconds to prevent a power interruption during elevator operation. User interfaces Basic interface panel: LED indicators provide at-a-glance source and transfer switch status for quick summary of system conditions. Test and override buttons allow delays to be bypassed for rapid system checkout. Digital display: The digital display provides a convenient method for monitoring load power conditions, adjusting transfer switch parameters, monitoring PowerCommand network status or reviewing transfer switch events. Password protection limits access to adjustments to authorized personnel. Control options Front panel security key (M017): Locks front panel to prevent access to digital control settings. Prevents unauthorized activation of transfer or test functions. Relay signal module (M023): Provides relay output contacts for sending information to an external monitoring and control system. Relay outputs include: Source 1 connected/available, Source 2 connected/available, not in auto, test/exercise active, failed to disconnect, failed to synchronize, failed to transfer/re-transfer, and elevator control pre-transfer signal. PowerCommand network interface (M031): Provides connection to the PowerCommand network. Load power and load current monitoring (M022): Measures load phase and neutral, current, power factor, real power (kw) and apparent power (kva). Warns of excessive neutral current resulting from unbalanced or nonlinear loads. Minimum current level detection is 3%. Utility protective relay Some utilities require closed transition transfer switches be provided to protect the utility service if the transfer switch malfunctions. All transfer switches include standard failure mode effect logic, which diagnoses failure of the switch to open or close when commanded, and provides appropriate alarm and response. Closed transition PLT transfer switches are available with optional protective relay(s), suitable for many utility applications. Soft load PLT transfer switches include a multifunction relay which provides reverse power protection and other utility protection functions.

PLT 06 Specifications Voltage rating 208 or 480 VAC, 50 or 60 Hz Operating temperature -40 F (-40 C) to 140 F (60 C) Storage temperature -40 F (-40 C) to 140 F (60 C) Altitude Up to 6,600 ft (2,000 m) without derating Surge withstand ratings Voltage surge performance and testing in compliance with the requirements of IEEE C62.41 (Category B3) and IEEE C62.45. Total transfer time (source-to-source) Will not exceed 6 cycles at 60 Hz with normal voltage applied to the actuator and without programmed transition enabled. Certifications All switches are UL 1008 listed and labeled, with UL-type rated cabinets and UL-listed CU-AL terminals. Suitable for use in emergency, legally required and standby applications per NEC 700, 701 and 702. All switches comply with NFPA 70, 99 and 110 (Level 1 systems). All switches comply with NEMA ICS 10. All switches comply with IEEE 446 Recommended Practice for Emergency and Standby Power Systems. This transfer switch is designed and manufactured in facilities certified to ISO9001.

PLT 07 Transition modes PLT models available: The open transition model does open transition and programmed transition in each direction. Momentary (fast) closed, soft load ramping modes perform open transition when transferring from a failed source and closed transition when transferring between two good sources. Open transition programmed: Switches from source to source over a pre-programmed time period, so that the load-generated voltages decay to a safe level before connecting to an energized source. Recommended by NEMA MG-1 to prevent nuisance-tripping breakers and load damage. Adjustable 0-60 seconds, default 0 seconds. Closed transition momentary: Used in applications where loads are sensitive to the brief power interruption that occurs when performing open transition between sources. Closed transition is accomplished by briefly (<100 msec) paralleling two good sources to eliminate the momentary interruption in the power supply. Closed transition soft load: Similar to momentary closed transition, but when two sources are available, the system actively synchronizes the generator set to the utility service, connects the two sources, ramps the load to the oncoming source over a preprogrammed time period, then disconnects the initial source. This allows transfer of loads from one source to another with minimum disturbance to the loads. Performs open transition when only one source is available. (This transition mode requires a Cummins Power Generation paralleling generator set.) Test mode: Allows the operator to simulate a power failure in the utility service, and verify proper system operation. System is configurable for open or closed transition operation in this mode.

PLT 08 UL withstand and closing ratings Withstand and Closing Ratings (WCR) are stated in symmetrical RMS amperes. Transfer switch ampere Breaker interrupt rating Breaker short-time withstand rating (1 sec) Breaker provided Trip unit 800 65,000 at 480 V 42,000 Square D Masterpact MicroLogic 6.0 1200 65,000 at 480 V 42,000 Square D Masterpact MicroLogic 6.0 1600 65,000 at 480 V 42,000 Square D Masterpact MicroLogic 6.0 2000 65,000 at 480 V 42,000 Square D Masterpact MicroLogic 6.0 2500 100,000 at 480 V 25,000 Square D Masterpact MicroLogic 6.0 3000 100,000 at 480 V 25,000 Square D Masterpact MicroLogic 6.0 Enclosures The transfer switch and control are floor-mounted in a key-locking enclosure. Wire bend space complies with 2008 NEC. NEMA Type 1 enclosure is standard. For outdoor applications, consult factory for available alternatives. Note: Auxiliary section is required for 2500-3000 amp switches. Amp rating Height Width Depth (Door closed) Depth (Door open) Weight Drawing reference 800-3000 in mm in mm in mm in mm lb kg top utility bottom utility Without AUX section 90 2286 36 915 48 1220 82 2068 2000 908 0500-3959 0500-3526 0500-3960 0500-3527 With AUX section (AUX Left, No Bus) 90 2286 60 1524 48 1220 82 2068 2600 1180 0500-3963 0500-3526 0500-3964 0500-3527 With AUX section (AUX Left, Bussed) 90 2286 60 1524 48 1220 82 2068 2600 1180 0500-3513 0500-3530 A034S248 0500-3531 With AUX section (AUX Right, No Bus) 90 2286 60 1524 48 1220 82 2068 2600 1180 0500-3961 0500-3526 0500-3962 0500-3527 With AUX section (AUX Right, Bussed) 90 2286 60 1524 48 1220 82 2068 2600 1180 0500-3511 0500-3528 0500-3512 0500-3529 Transfer switch lug capacities All lugs accept copper or aluminum wire unless indicated otherwise. Amp rating Cables per phase Size 800 3 #2-500MCM 1200 4 #2-500MCM 1600 5 #2-500MCM 2000 6 #2-500MCM 2500 7 #2-500MCM 3000 8 #2-500MCM

PLT 09 Submittal detail Amperage ratings 800 1200 1600 2000 2500 3000 Voltage ratings R021 208V R026 480V Pole configuration A028 3 poles (solid neutral) A029 4 poles (switched neutral) Frequency A044 60 Hz A045 50 Hz Transfer mode A078 Open programmed A079 Closed momentary A081 Closed soft load Application A035 Utility-to-genset System options A042 Three phase, 3-wire or 4-wire Enclosure B001 Cabinet Type 1 N068 Utility entrance top N069 Utility entrance bottom Auxiliary sections N021 Auxiliary section mounted right N022 Auxiliary section mounted left N065 Auxiliary section additional bus Standards B024 Service entrance rating S043 UL 1008 certification Control options M017 Security key front panel M023 Relay signal module M031 PowerCommand network communications module M022 Load power and load current monitoring Meter D009 Analog bar graph meter Protective relays M051 Multifunction relay M038 Lockout relay M049 Additional lockout relay M050 Ground fault sensing Warranty G010 Years 0-2: Parts, labor and travel Years 3-5: Parts only Years 6-10: Main contacts only G013 Years 0-5: Parts, labor and travel Years 6-10: Main contacts only

North America 1400 73rd Avenue N.E. Minneapolis, MN 55432 USA Phone 763 574 5000 Fax 763 574 5298 Asia Pacific 10 Toh Guan Road #07-01 TT International Tradepark Singapore 608838 Phone 65 6417 2388 Fax 65 6417 2399 Brazil Rua Jati, 310 Guarulhos Sao Paulo CEP 07180-140 Phone 55 11 2186 4195 Fax 55 11 2186 4729 Europe, CIS, Middle East & Africa Manston Park Columbus Ave. Manston Ramsgate Kent CT 12 5BF United Kingdom Phone 44 1843 255000 Fax 44 1843 255902 2010 Cummins Power Generation All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand and Our energy working for you. are trademarks of Cummins Power Generation. Specifications are subject to change without notice.