Spray Foam. Exceptional Products for Exceptional Design

Similar documents
Get Rid of Roof Problems for Good. How spray foam roofing can protect your building and make you money

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Spray Polyurethane Foam Insulation. Creating Cost Effective, Energy Efficient, Green Buildings

Open-cell spray foam & what every contractor

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

Roof Insulation Building. Energy. Environment friendly e-library

Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature

COMMERCIAL BUILDING APPLICATIONS

Building Owners Guide to a Duro-Last System!

Specifying SPF Roofing Systems

Avoiding Air Barrier Pitfalls

metal Duil~ing manufacturers Association

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

CHAPTER 7: Building Systems ROOFING SYSTEMS

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

Underwriters Laboratories Testing Information

Continuous Insulation Using Polyiso Wall Sheathing

Foundation. Foundation

The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.

An American Institute of Architects (AIA) Continuing Education Program Credit for this course is 1 AIA/CES HSW Learning Unit

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

ISO Types 1-6: Construction Code Descriptions

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

FOAMULAR LT40, 400 and 600 insulations with minimum compressive strengths of

DELTA Premium Moisture Management Systems for Foundations.

Roof Restoration System. For building owners, property management firms and facility managers. seamless possibilities

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

ROXUL COMMERCIAL ROOFING. Understanding Climate Requirements That Drive Performance. roxul.com

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

Comment Form on Proposed Gut Rehabilitation Alternatives

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

Water Damage & Repair

GAF HydroStop Brochure

RACKING AND ATTACHMENT CRITERIA FOR EFFECTIVE MEMBRANE ROOF SYSTEM INTEGRATION Public Version 1: July 9, 2012

Low-slope reroofing guidelines

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.

Introduction to Energy Performance of Brick Masonry

UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Performance of 8 Passive House Envelopes in Cold Climates

The Perfect Fit For Metal Retrofit

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

research highlight Highly Energy Efficient Building Envelope Retrofits for Houses

Getting The Most Out of Your Roof Asset. Program #099 PM

The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A

The Foundation Group SSIPS vs Concrete Block and Wood Framing

Renovating Your Basement

A Kingspan Summary of a Building Science Corporation Report

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

FAST FACTS ADVANTAGES OF MULTI PLY BUILT-UP ROOFING. Asphalt Roofing Manufacturers Association

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name:

United States. Why You Should Insulate Foundations. There is a science to adding value.

PIMA Technical Bulletin #115. The High R Roof: Guidelines for Energy-Efficient Roofing and Re-Roofing. What is a High R Roof?

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

Signs of insulation problems In the winter. In the summer. conditioning system

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

TARRANT COUNTY DETAIL STANDARDS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

stand the tests of time, & economics

Roof Condition Analysis

SWD URETHANE COATED FOAM ROOFING SYSTEM MASTER ROOF SPECIFICATION SECTION

Insulation R-Value Comparisons

More Bang for Your Buck: Combining Thermal, Air and Water Barrier

The Case for Cross Laminated Timber: Part 2

s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In

COMMONLY USED RESIDENTIAL BUILDING CODES

Best Practices for Crawl Space Insulation

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

Preventing Ice Dams on Roofs

Insulating Unvented Attics With Spray Foam

Basements are Changing. Basements Part of the Enclosure. Basements. Energy Efficient, Durable, Healthy. Below grade enclosure

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

architect builder/developer contractor design professional

RECOATING AND RENEWING SPF ROOFING SYSTEMS

CLOSED-CELL SPRAY FOAM Resisting Wind Uplift in Residential Buildings

Meeting the Fire Code with Continuous Foam Plastic Insulation

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film

CONDENSATION IN REFRIDGERATED BUILDINGS

Presented by: Jennifer Doyle, P.E., RRC, LEED AP

Materials and Colors

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

Ver. 2. Guide to. Inspecting Residential Brick Veneer

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

R-Value and Densities Chart

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

bout your HOUSE before you start Repairing And Replacing Materials Exterior Walls

Insulation Products For Residential Thermal Applications ROXUL. Better Best ROXUL. Solutions For Residential Thermal Applications.

Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction

Heating Load Calculation

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

The science of better-performing buildings.

Transcription:

Spray Foam Exceptional Products for Exceptional Design

About Celebrating over 40 years of Foam Since 1972- One of the oldest spray foam suppliers in the construction industry. Quik-Shield Insulation and Roofing Products Quik-Shield is the best choice in roofing and insulation. It is a spray-applied foam that can be used as an air sealing barrier and continuous insulation in commercial, industrial, and residential buildings. Quik-Shield spray foam creates a completely seamless air barrier that is energy-efficient, sustainable, and environmentally friendly. Quik-Shield Roofing System Quik-Shield Wall System believes in creating strong partnerships. Unlike commodity suppliers, SWD will work with you to develop best-result solutions based on your specific needs. manufactures a wide product line including over 45 polyurethane foams and polyurea coatings. Quik-Shield Roof Coating Quik-Shield Spray Foam Roof Deck Steel Studs Quik-Shield Spray Foam Masonry Veneer is an AIA/CES registered provider. We can provide a full range of educational presentations for your architectural or design firm. is a member of the U.S. Green Building Council. Quik-Shield spray foam is a LEED qualified material and counts towards LEED points. Quik-Shield closed-cell insulation carries GREENGUARD GOLD certification, the highest certification level. Our product development team is committed to leading the industry with innovative and top performing products that deliver outstanding results. International Offices Form vs Function Spray Foam insulation allows form and function to work together. The expansion of the spray-applied foam means that unique shapes and designs can still be effectively insulated.

A properly designed building envelope needs to provide the highest performance possible against four elements: rain, air, vapor, and heat. Closed-cell spray foam is the only product that can provide all four barriers in a single, seamless material. Designing a Better Building Envelope Fire rated assemblies Concrete separators can be completely covered by foam, reducing thermal bridging Quik-Shield spray foam is self flashing and provides seamless coverage around HVAC curbs, vents, and skylights. 97.6% No Ponding Quik-Shield spray foam roofing systems provide proper slope to drain, with minimal cost of material and labor. 82% of spray foam roofing systems do not leak at an average of 10 years 3 of Solar Energy Reflected away 4 40% Savings Quik-Shield Spray Foam can decrease a building's heating and cooling costs by as much as 40% 6 No Seams or Fasteners hourly fire rated assemblies are available for quik-shield wall and roof products Vapor Retarder More to consider than just r-value Two insulation attributes affect energy consumption: thermal (r-value) and air Barriers. Of these factors, the air barrier typically plays a more significant role. spray foam supplies both a seamless air barrier and one of the highest r-values on the market today. Quik-Shield closedcell spray foams are effective vapor retarders at an installed depth of 1.2 inches or greater 1 Seamless Air Barrier Open Cell foam is very good at absorbing sound and can be used in accoustical wall assemblies Extreme heat and cold reduce fiberglass R-value by 50% or more 2 Typically, a building envelope runs about 10-20% of the cost of the building, but represents 70% of the liability costs 5 1 sq ft of Quik-shield slab insulation has a compressive strength greater than 5 tons 1 Intertek Research Report #1011 2 Oakridge National Laboratories 3 Del E. Webb School of Construction at Arizona State University 4 Cool Roof Rating Council (CRRC) 5 Associated General Contractors of America, American Bar Association 6 National Institute of Standards and Technology (NIST) Quik-Shield spray foam creates a seamless air barrier per ASTM E-283

Quik-Shield Products Under-Slab Insulation Quik-Shield 121 Under-Slab Foam Insulation High Density (3 lb/5 lb) R-Value - 6.5/6.0 Quik-Shield 106 Open-cell Spray Foam Insulation Light Density (1/2 lb) R-Value at 1-4.0 Quik-Shield 112 Closed-cell Spray Foam Insulation Medium Density (2 lb) R-Value - 6.6 Quik-Shield 125 Closed-cell Roofing Foam High Density (2.5-3 lb) R-Value at 1-6.3 Quik-Shield 121 Case Study Residential Home Wyoming Studies have shown that as much as 15% of a building s heat loss is through the foundation slab and many building codes require under-slab insulation in climate zones 4 and higher. High Compressive Strength Water Resistive Barrier Seamless Air and Vapor Retarder Under-Slab Insulation Commercial, Industrial, and Residential Construction Interior Applications Only Greater Sound Absorption Climate Zones 1-5 Residential Construction IDEAL FOR Exterior and Interior Applications Increases Structural Strength Can be submerged in floodwaters 72 hours or more without sustaining damage Climate Zones 5-8 and areas that experience extreme weather events Commercial, Industrial, and Residential Construction Roofing Applications Self-Flashing No Mechanical Fasteners Commercial, Industrial, and Residential Roofing GYP BOARD BRICK OR STUCCO WALL STUD WALL EXPANSION JOINT QUIK-SHIELD CLOSED-CELL SPRAY POLYURETHANE FOAM ENGINEERED FILL Quik-Shield 121 is designed for residential, commercial and industrial applications. It is sprayed directly to engineered fill gravel, prior to slab pour. Unlike boardstock, spray foam provides a seamless and monolithic layer of insulation. Quik-Shield slab foam seals completely around plumbing and other penetrations, creating a superior vapor and water resistive barrier. This 4,000 sq ft home utilized 3 of Quik-Shield spray foam beneath the slab. Quik-Shield slab insulation is also completely compatible with radiant floor heating systems. D-1621 Compressive Strength >70 PSI/>100 PSI CCRR-1011 IRR 1011 Meets IRC Section 316.6 and IBC Section 2603.10 without any ignition barrier APPROVALS CCRR-1011 IRR 1011 AC 377 (NFPA 286) Appendix X without any ignition barrier ICC-ESR 2532 UL #R9303 Class A/B/C Roof System UL Hourly Fire Rated Assemblies high compressive strength- standard 4" slab equals less than 1% of the total stress capacity of the foam 2" of Foam Insulation blocks 92% of heat transfer Higher Densities available to support 100 PSI applications in heavy industrial and E-119, NFPA 285 Miami-Dade and FM Global Approved commercial buildings

Walls Quik-Shield closed-cell spray foam is the best choice when insulating and protecting commercial and residential buildings. It creates a completely seamless air barrier that is energy-efficient, sustainable, and environmentally friendly. Closed-cell spray foam is the only product that functions as all four building envelope barriers- air barrier, thermal insulation, vapor retarder, and water resistive barrier. In addition to saving on heating and cooling costs, money is saved during construction because no additional building envelope barriers are needed. Save up to 40% Heating and Cooling No Additional Building Envelope Barriers Needed Prevents Mold and Moisture Damage Continuous Insulation Energy Efficient Increases Structural Racking Strength Environmentally Friendly INTTERIOR GYPSUM BOARD STUD WALL CONSTRUCTION (WOOD, STEEL) EXTERIOR WALL SHEATHING QUIK-SHIELD CLOSED-CELL SPRAYED POLYURETHANE FOAM 3.5 MINIMUM DRAINED CAVITY (AIR SPACE) BETWEEN SPRAY FOAM INSULATION AND EXTERIOR FINISH Quik-Shield 112 STEEL STRUCTURE TRANSITION MEMBRANE MASONRY VENEER (BRICK, STONE) MASONRY TIE Note: Vapor barrier to be placed per local code requirements. Quik-Shield 112 applied to exterior of building for continuous insulation Can be applied to most types of substrate including metal and wood NFPA 285, E-119 assemblies available Quik-Shield 112 Closed-Cell Quik-Shield 106 Open-Cell Fiberglass Extruded Polystyrene Case Study Commercial Warehouse Sheridan, Wyoming Air Leakage (L/s/m 2 ).0002.0004 Not an Air Barrier Not a Seamless Material Water Absorption (%) Water Vapor Permeance 1.0 2.9 Not a Water Barrier 0.3 Class II Not a Vapor Retarder Not a Vapor Retarder Class II or III Rockwool Not an Air Barrier Not a Water Barrier Not a Vapor Retarder EMIT Technologies, headquartered in Sheridan, WY, provides environmental solutions for the oil and gas industry to improve air quality. When EMIT made plans to build a new manufacturing facility in Sheridan for a new product line, closed-cell spray foam was the only insulation product they would consider. EMIT has seen the structural and energy advantages of spray foam and has insulated over a dozen of their other buildings with it. Quik-Shield 112 closed-cell spray foam was applied at a thickness of 3 to the interior of the walls of their newest location. When their other facilities used conventional insulation materials, EMIT experienced extremely high energy bills and problems with air leakage. Sheridan experiences winter temperature averages at 9 F and yearly sees about 72 of snow. The Quik-Shield spray foam helps maintain a comfortable working environment, lowers energy bills, and serves as a vapor barrier to help control moisture issues.

Roofs Thermal Shorts and Bridging Quik-shield solution POLYISO BOARD QUIK-SHIELD ROOFING FOAM METAL DECKING METAL DECKING Quik-Shield Superior Performance Problems with Wind Uplift Fasteners and seams allow air to leak beneath the membrane. The wind pressure can cause fluttering of the membrane and, potentially, roof blow off. Quik-Shield spray foam on a metal deck maxed out the Miami-Dade wind uplift test at over 500 mph. QUIK-SHIELD ROOFING FOAM QUIK-SHIELD COATING FASTENERS THROUGH DECK CREATE HEAT LEAK MEMBRANE FILLED WITH LEAKING AIR GAPS IN BOARD CREATE HEAT LEAK FOAM BOARD METAL DECKING GAP IN RECOVER BOARD Built-Up INCORRECT ROOFING SYSTEM Lifecycle Cost* (per square foot) $2.95 Quik-Shield Roofing System Single Ply CORRECT ROOFING SYSTEM $4.00 $0.85 Hard to achieve slope to drain, results in ponding and leaking Difficult to seal seams properly and hard to locate leaks when they occur Seamless and monolithic, virtually leak proof Prone to alligatoring and blistering, mandatory tear-off at end of life cycle Can shrink and cause delamination, requires additional roof inspections Can be applied over conventional roofs, only recoating is needed to extend life span Construction Waste** 176,800 lbs 70,000 lbs 55 lbs Life Span 10-20 years 10-15 years 40+ Leak Potential Additional Costs * NRCA ** 40,000 sq ft roof over 30 years, assumes traditional roof tear-off LEAKING AIR Case Study HANE FOA RET M YU TOMAR Electronics QUICKSHIELD ROOFING SYSTEM CE LIAN AL 1" or more of Quik-Shield 125 significantly reduces heat transfer through studs, fasteners, and roof deck gaps. SPRAY PO L Fasteners and seams on Single-Ply roofs allow heat to transfer, wasting energy and money 2014CORRECT ROOFING SYSTEM This award-winning project included a 22,500 sq ft building expansion and the retrofit of the existing 68,000 sq ft warehouse facility roof. Quik-Shield 125 2.5lb roofing spray foam was applied, with acrylic and cementitious top coats. This roof was a low slope, B metal deck and was covered with 560 photovoltaic panels and 76 skylights. TOMAR had previously experienced a lot of problems with leaking, due to the inability of the previous roofing product to properly seal all of the seams and penetrations. Spray foam is seamless and self-flashing, which solved the building s issues with leaks. The Quik-Shield roofing system is incredibly energy efficient. The Quik-Shield air barrier and the high solar reflectance of the acrylic coating helped make TOMAR one of the few manufacturing facilities in the U.S. to achieve a near net-zero energy rating.

Call us Today For all of your Specification Needs The Quik-Shield brand is owned and operated by: is an accredited aia/ces provider. contact us today to schedule your next course QS-AB 04-14