CWDM MUX and DEMUX Modules and Frame

Similar documents
Wideband Optical Splitters FOS Series

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

Cisco CWDM GBIC and CWDM SFP Installation Note

SFP Transceiver Specifications

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

CISCO WDM SERIES OF CWDM PASSIVE DEVICES

Recession-Proof Consulting Services with CWDM Network Design

10G CWDM Conversion Technology

4RU High Density Shelf Installation Instructions

VG4 Fiber Optic Media Converter

GIGABIT GATEWAY TECHNOTE

Backup Scanner Module

Perle 10/100/1000 Ethernet Media Converter Module

FACT OPTICAL DISTRIBUTION FRAME SYSTEM

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

InstaPATCH ZERO Solution Guide

Gigabit Ethernet Copper-to-Fiber Converters

Replacing a Copper or Fiber Transceiver on a NetScaler Appliance

Power Supply Guide Version 1.0 for D-Show

Gigabit Switching Ethernet Media Converters - Product User Guide

Attaching the PA-A1-ATM Interface Cables

RC001-4/RC002-4 (REV.B) 4-slot rack mounted chassis User manual

MRC High Resolution. MR-compatible digital HD video camera. User manual

Multiplexing. Multiplexing is the set of techniques that allows the simultaneous transmission of multiple signals across a single physical medium.

Rack Installation Instructions

ColdGuard Bi-PARTING DOOR INSTALLATION INSTRUCTIONS

16/32 Channel 1U Rack Mount CCTV Power Supply

Connector and Cable Specifications

Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)

Fiber Optic Ethernet Media Converter Kit

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

Perle Protocol Transparent Media Converter Modules

Remote Sources. Facility. Router

First Data FD130 Terminal. Quick Set-up Guide

System Wiring Design Guide

HP SATA/SAS hard drive and Solid State Drive installation

IP DSLAM IDL Quick Installation Guide

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Fibre Channel Fiber-to-Fiber Media Converters

Using a Fabric Extender with a Cisco Nexus 5000 Series Switch

About the HotWire Slot Standalone Shelf

Installing Your 960 or 980 Server into a Rackmount Cabinet

Small form factor bay converter and hard drive installation

Perle 10/100 Ethernet Media Converters

Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution.

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

2014 AT&T Intellectual Property. All rights reserved. AT&T, Globe logo and other marks are trademarks of AT&T Intellectual Property.

Control Box Wiring For PRSstandard Tool

Arista 40G Cabling and Transceivers: Q&A

TransPacket white paper. CWDM and DWDM networking. Increasing fibre-optical network utilization and saving on switches/routers

Vertical Phone System Upgrades Scope of Work

Rack Mount Kit Install Guide: Intel Entry Server Chassis SC5295-E UP/DP/WS/BRP Intel Entry Server Chassis SC5299-E DP/WS/BRP

GSM-EXT Cable Assembly Installation Guide

Module Connectors and Cable Specifications

DVI DA2 and DVI DA 4 User Guide

Optimux-34, Optimux-25

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

McAfee Network Security Platform

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

HP ProCurve High-Speed Transceivers Installation Guide

10/100/1000 Base-T to Gigabit Fiber Media Converter

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

Full_IG.book Page 1 Monday, January 9, :11 PM. ProSafe 24 Port Gigabit Switch Installation Guide

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

Cisco SFP Optics for Gigabit Ethernet Applications

Setting Up and Testing the MAX Hardware

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Fading Red Tones on Color LaserJet 2600s

How To Use A Network Instrument Ntap

767 Diagnostic System

DE1600 DSA E-Series iscsi Disk Arrays. en Quick Install Guide

AIRAVE 2.5 User Guide

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

MCR1900 Media Converter 19-Slot Chassis

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Optimux-134, Optimux-125

ASKING FOR ASSISTANCE

CX Zoner Installation & User Guide

T1 Backhaul Connectivity Solution All Products :: Application Note

LANC Fibre Patch Panel Solution

Antenna Splitter ASA 1. Instruction manual

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

HARTING mcon 1000 Introduction and features

HARTING Ethernet Cabling 8-poles Overview

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

SYSTEM 4C. C R H Electronics Design

Service Guide. Gateway M275

Power Supply and Cabling Options. SmartTrak 100/101/140

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

BLACK BOX Scalable matrix KVM switch supports up to 1024 ports with fiber or copper cable.

About the BitStorm 6051 POTS Splitter

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

DDP-3 Engineering Guide

SECTION 7 - REPAIR/REPLACEMENT PROCEDURES

Actiontec Router Troubleshooting

Removing memory and option cards

Rail Kit Install Guide: Intel Modular Server System MFSYS25 A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products

Transcription:

CWDM MUX and DEMUX Modules and Frame Guide to Installation and Operation M949-9900-102 16 May 2014 Miranda Technologies 3499 Douglas-B.-Floreani St-Laurent, Québec, Canada H4S 2C6 Tel. 514-333-1772 Fax. 514-333-9828 www.miranda.com 2014 Miranda Technologies

CONTACT MIRANDA For technical assistance, please contact the Miranda Technical support center nearest you: Americas 9:00 am 9:00 pm EST Tel: +1 800 224 7882 Fax: +1 514 335 1614 support@miranda.com France 9:00 am 5:00 pm GMT+1 Tel: +33 1 55 86 87 88 Fax: +33 1 55 86 00 29 Asia 9:30 am 6:00 pm GMT+8 Tel: +852 2539 6987 Fax: +852 2539 0804 asiatech@miranda.com ina 9:30 am 6:00 pm GMT+8 Tel: +86 10 5873 1814 Europe, UK, Middle East, Africa 9:00 am 6:00 pm GMT Tel: +44 118 952 3444 Fax: +44 118 952 3401 eurotech@miranda.com (Playout Automation Only) 9:00 am 5:30 pm GMT Tel: +44 8705 004 350 Fax: +44 8705 004 333 Emergency After Hours (worldwide) Tel: 1 800 224 7882 -or- Tel: 1 514 333 1772 and choose menu option 2 eurotech@miranda.com asiatech@miranda.com automationsupport@miranda.com Visit our web site at www.miranda.com CWDM Modules & Frame

Table of Contents 1 CWDM MUX and DEMUX Modules and Frame... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Available Modules... 2 1.4 MUX Operation... 3 1.5 DEMUX Operation... 4 2 Installation... 5 3 Operation... 6 4 Specifications... 8 CWDM Modules & Frame

CWDM Modules & Frame

1 CWDM MUX and DEMUX Modules and Frame 1.1 Introduction The Miranda CWDM mux/demux modules are bi-directional passive optical multiplexers and demultiplexers, allowing multiple optical signals at different wavelengths to pass through a single optical fiber strand. The product is designed to integrate conveniently with Miranda s FIO-1901, FIO-991 and FIO-991p series of optical/electrical converters, but is equally useful with other products working with CWDM wavelengths, such as Miranda s NVISION routers. The CWDM mux/demux combines up to 18 different-wavelength signals from different optical fibers into a single optical fiber, or separates up to 18 different-wavelength signals coming from a single optical fiber to 18 separate optical fibers. The units are completely agnostic to the signal type, allowing different signals such as AES, MADI, DVB-ASI, 3Gbps/HD/SD SDI or Ethernet to travel in either direction on the same fiber link. 1.2 Features 4, 8, 16 or 18 channel optical mux/demux Long distance coverage of multiple signals on a single fiber strand Various types of signals supported such as 3Gbps/HD/SD, AES, DVB-ASI, Ethernet, etc. Same module can be used in either direction, allowing some channels in one direction and other channels in opposite direction Passive CWDM optical mux/demux design Minimizes content delivery costs where dark fiber is available Packaged in the same modular form as Miranda s FOS series of optical splitters, with all modules the same width, and configured to install in a convenient 1RU tray that holds up to 10 single height modules or 5 double height modules, or any combination of both CWDM Modules & Frame 1

1.3 Available Modules The following modules are available for this series: CWDM-4-LC CWDM-8-LC CWDM-16-LC 2 CWDM Modules & Frame

CWDM-18-LC 1.4 MUX Operation When used as MUX, modules have multiple inputs and a single output. The inputs are paired, according to the pairs of optical frequencies/wavelengths supplied by standard SFP-TT modules, allowing easy use of reverse fiber position duplex patch cords (see the image below). The label of each input pair on the CWDM unit is color coded, as shown in the following chart, to match the color coding on the clasp handle of the SFP-TT module that is required to drive that input. The optical wavelengths conform to ITU-T Rec. G.694.2 (12/2003). Note that the wavelengths have been offset by I nm relative to the former revision of the standard. SFP-TT Module Type Feeding Input Optical Input Wavelengths Label on Panel Panel Label Color Code SFP-TT-C27C29-LC 1271 / 1291 nm 27 29 Light Purple X X SFP-TT-C31C33-LC 1311 / 1331 nm 31 33 Yellow Green X X SFP-TT-C35C37-LC 1351 / 1371 nm 35 37 Pink X X SFP-TT-C39C41-LC 1391 / 1411 nm 39 41 White X SFP-TT-C43C45-LC 1431 / 1451 nm 43 45 Black X X SFP-TT-C47C49-LC 1471 / 1491 nm 47 49 Gray X X X SFP-TT-C51C53-LC 1511 / 1531 nm 51 53 Blue X X X SFP-TT-C55C57-LC 1551 / 1571 nm 55 57 Yellow X X X X SFP-TT-C59C61-LC 1591 / 1611 nm 59 61 Red X X X X 4 8 16 18 CWDM Modules & Frame 3

You must use this duplex patch cord at the inputs in MUX operation. Alternatively, simplex patch cords can be used. 1.5 DEMUX Operation When used as DEMUX, modules have a single input and multiple outputs. The outputs are paired, according to the pairs of optical frequencies/wavelengths supplied by standard SFP-TT modules. This allows easy use of duplex patch cords (continuous fiber position see the image below) between each module output and its associated downstream SFP receiver. The output pairs are color coded, as shown in the following chart, to match the color coding on the clasp handles of SFP-TT modules operating at the associated wavelengths. The SFP-RR receiver, however, is universal and accepts all wavelengths that can be carried by this CWDM system. This receiver has a blue clasp handle. Optical Output Wavelengths Label on Panel Panel Label Color Code 4 8 16 1271 / 1291 nm 27 29 Light Purple X X 18 Downstream SFP Receiver Modules 1311 / 1331 nm 31 33 Yellow Green X X 1351 / 1371 nm 35 37 Pink X X 1391 / 1411 nm 39 41 White X 1431 / 1451 nm 43 45 Black X X SFP-RR-LC (1260-1620 nm) 1471 / 1491 nm 47 49 Gray X X X 1511 / 1531 nm 51 53 Blue X X X 1551 / 1571 nm 55 57 Yellow X X X X 1591 / 1611 nm 59 61 Red X X X X You must use this duplex patch cord at the outputs in DEMUX operation. Alternatively, simplex patch cords can be used. 4 CWDM Modules & Frame

2 Installation Install the tray into a standard 19 rack using 4 standard rack-mounting screws through the four holes in the corners of the mounting flanges. An available support bracket extending from the front of the tray provides physical support for the fiber cables, minimizing strain on the connectors. Several different configurations are available for the support bracket and mounting flanges, to accommodate different installation set-ups. Slide each CWDM module into an empty bay in the tray, and secure it in position with the two captive screws on the front flanges. CWDM Modules & Frame 5

3 Operation There are no operating controls or adjustments on this product. Warning: Infrared radiation is invisible and can seriously damage the retina of the eye. Do not look into the end of an active fiber. A clean, protective cap or hood MUST be immediately placed over any radiating connector or optical fiber to avoid exposure to potentially dangerous amounts of radiation. This practice also helps prevent contamination of connectors and adapters. Do not assume laser power is turned off or the fiber is disconnected at the other end. Avertissement : Le rayonnement infrarouge est invisible et peut sérieusement endommager la rétine de l'œil. Ne regardez pas dans l'extrémité d'une fibre active. Un capuchon de protection propre doit être immédiatement placé sur n'importe quel connecteur rayonnant pour fibre optique pour éviter l'exposition à des quantités potentiellement dangereuses de rayonnement. Cette pratique permet également de prévenir la contamination des connecteurs et adaptateurs. Ne présumez pas que la puissance du laser est désactivée ou la fibre est déconnectée à l'autre extrémité Caution: Class 1M Laser radiation when fiber connector is unplugged. Mise en garde: Rayonnement laser de la classe 1M lorsque le connecteur de fibre est débranché. Plug the LC connector on the end of the fiber cable into the appropriate connector on the CWDM module. Be sure to match the wavelength of the input signals arriving on the fiber cable to the wavelength specified for the input on the MUX module. Mismatched signals will not pass through the system. Remove any dust plugs from the connectors on the fiber and CWDM module Push the fiber connector straight into the module socket until it clicks into place To disconnect a fiber from the module: NEVER pull on the cable itself to disconnect a fiber; ALWAYS grip the connector, push in the release tab and pull straight out ALWAYS place a plug into any unused fiber ports, to keep out dust and debris The figures below illustrate typical 4, 8, 16 and 18-channel MUX-DEMUX connection scenarios. 6 CWDM Modules & Frame

CWDM Modules & Frame 7

4 Specifications annel spacing: annel passband: Adjacent channel isolation: Non-adjacent channel isolation: Directivity: Return loss: Passband ripple: 20 nm CW +/-7 nm > 30 db > 40 db > 50 db > 45 db < 0.5 db CWDM MUX/DEMUX CWDM-4-LC: Wavelengths: 1551, 1571, 1591, 1611 nm Insertion loss: < 1.8 db Module height: half height (1 2 U) CWDM-8-LC *: Wavelengths: 1471, 1491, 1511, 1531, 1551, 1571, 1591, 1611 nm Insertion loss: < 1.8 db Module height: half height (1 2 U) CWDM-16-LC: Wavelengths: 1271, 1291, 1311, 1331, 1351, 1371, 1431, 1451, 1471, 1491, 1511, 1531, 1551, 1571, 1591, 1611 nm Insertion loss: < 3.0 db Module height: full height (1 U) CWDM-18-LC *: Wavelengths: 1271, 1291, 1311, 1331, 1351, 1371, 1391, 1411, 1431, 1451, 1471, 1491, 1511, 1531, 1551, 1571, 1591, 1611 nm Insertion loss: < 3.0 db Module height: full height (1 U) END-TO-END MUX/DEMUX INSERTION LOSS 4 wavelengths: < 3 db 8 wavelengths: < 3 db 16 wavelengths: < 6 db 18 wavelengths: < 6 db ENVIRONMENTAL Operating temperature range: 0 C ~ 70 C * Use of wavelengths in the vicinity of 1380 nm requires the use of Zero Water Peak Fiber cables, i.e. conforming to Rec. ITU -T G.652 (11/2009), C or D attributes. 8 CWDM Modules & Frame