INNOVAIR Intelligent Fan Convectors IQL Controller SIZE 1 & 2 Units INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Innovair Size 1 & 2 IQL Units



Similar documents
The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

Invisidor STYLE Air Curtain

Installation, operation and maintenance manual TX 35A

Cooktop Low-Profile Ventilation Hoods

Portable Air Conditioner

Accessory Manual Ventilation Section Model Comfort Circle

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Remote Head REMO ONE. Code Manual

IH E Sigma Island 90

TS93 EMR T/PT/TDE. Surface applied door closer

INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Installation Instructions

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

ECOCIAT. Domestic hot water heat recovery unit

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Technical catalogue convectors POLAND 2012

squrboxbox heat recovery squrboxbox I technical information

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

T7560A,B,C Digital Wall Module

Select Radiators Installation Guide

HERZ-Thermal Actuators

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Material test chamber with mechanical convection

User Manual: C Long Point Houston, TX Facebook.com/CoolAZone Twitter.com/CoolAZone

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units

Installation Instructions

I. Introduction 02. Specifications 02 Accessories 02 Features 03. II. Installation Instructions 06

HeatSource HS1800 Heater

Taurus Series YORK Window Air Conditioners

LUCCI AIRFUSION QUEST II CEILING FAN

Radiant Temperature Sensor TY7321

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Variable Air Volume - VAV

Incubator with mechanical convection

USER S MANUAL HSC-24A

FLEXIT S3 X/TT A3 X/TT K3 X/TT S3 R S3 RK

DMSG_0152_0112_V4 Mamas & Papas (Holdings) Ltd Dream Swing - 1 -

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

Medical Lighting. XL4 Patient Light

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

INSTALLATION & USER INSTRUCTIONS

Installation and maintenance instructions. Danfoss Vent

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

CO2 Alarm. Operation. Application

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

Fiberstars Lighted Laminar Flow Fountain Installation Manual

SPECIAL APPLICATIONS

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales

Original Assembly Guide

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

E-PDD Duct Smoke Detector Installation Sheet

Table of Contents. 1 - Specifications Installation Wiring User controls...7

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

MOUNTING AND OPERATING INSTRUCTIONS

Installation Instructions

Installation Instructions For Slider Casement Air Conditioners

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

RRV934. Multi-controller. Synco living

VOYAGER 570G. 744A Sprayer Control

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Electronic Control Devices The European Product Catalogue 2007

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Munchkin Heat Exchanger Maintenance

Overheating limit control

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Commercial Gas Furnace Upflow

Heating and Hot Water Services Controls General Technical Specification

Aerona Air Source Heat Pumps

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

PANASONIC TROUBLE SHOOTING GUIDE

Domestic AC Fans 230V Installation and Operating Guide. eco 230V AC Base Models: icon eco icon icon icon

How To Use A Power Supply On A Powerline 2.2 (Ai)

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Installation Instructions

SERVICE MANUAL. Corpus 3G. Seat system for electric wheelchair

HVAC Processes. Lecture 7

COMMISSIONING OF HVAC SYSTEMS

Transcription:

INNOVAIR Intelligent Fan Convectors IQL Controller SIZE 1 & 2 Units INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS Page 1

CONTENTS GENERAL INFORMATION Important Page 3 Dimensions & Weights.. Page 3 Ductwork Connections.. Page 4 Fixing Crs & Coil Connections.. Page 5 INSTALLATION Stages Involved.. Pages 6 to 8 Connecting the Unit to Mains Power Page 9 Customer Connection Centre Diagram Water heated units Page 10 Customer Connection Centre Diagram Electrically heated Units. Page 11 TBA Connecting the Remote Control Pad to the Unit.. Page 12 Connecting Units as Master/Slave or.slave/slave Arrangement..... Page 12 Connecting the Unit to a BMS. Page 13 Connecting the Unit to a Timer Clock or PIR. Page 13 Connecting the Unit to an Extract System... Page 14 Connecting the Unit to a Biddle CO 2 Sensor.. Page 15 OPERATION Control Pad.. Pages 16, 17 & 18 MAINTENANCE Access Panel. Page 19 End Panels Page 19 Filter Page 19 Fans & Motors. Page 19 Heating Coil. Page 19 Damper & Actuator. Page 19 Casing.. Page 19 Page 2

GENERAL INFORMATION IMPORTANT! IT IS ESSENTIAL TO ISOLATE THE UNIT FROM THE ELECTRICAL SUPPLY AND THE CONTROL CIRCUIT POWER SUPPLY BEFORE CARRYING OUT ANY MAINTENANCE, AND TO ENSURE THAT THE POWER CANNOT BE ACCIDENTLY RESTORED BY UNAUTHORISED PERSONNEL. DIMENSIONS & WEIGHTS Size 1 Size 2 Cased Recessed Cased Recessed Width 735mm 633mm 1238mm 1136mm Depth 245mm 245mm 245mm 245mm Height 680mm 680mm 680mm 680mm Weight 28kg 26kg 41kg 39kg Cased unit (with fixed grilles) Figure 1a Height Size 1 Width Depth Size 2 Width Recessed/Chassis unit (with loose grilles) Figure 1b Height Size 1 Width Depth Size 2 Width Page 3

FRESH AIR INLET SPIGOTS (BACK OR BOTTOM ENTRY) Rectangular FAI & Plate Width Height Depth Size 1 403 127 25 Size 2 906 127 25 Circular FAI s & Plate Pitch Separation Diameter Depth Number of s Size 1 1 x 236 150 35 2 Size 2 3 x 246 150 35 4 DISCHARGE SPIGOTS (ON RECESSED/CHASSIS UNITS ONLY) Ceiling or Wall Mounted Unit Rectangular Discharge Casing style WL2 or CL2 (recommended) Ceiling or Wall Mounted Unit Rectangular Discharge Casing style WL1 or CL1 (not recommended) Ceiling or Wall Mounted Unit Circular Discharge s All styles Width Height Depth Size 1 632 164.5 25 Size 2 1135 164.5 25 Width Height Depth Size 1 632 164.5 25 Size 2 1135 164.5 25 Pitch Separation Diameter Depth Number of s Size 1 2 x 204.5 150 35 3 Size 2 4 x 218.0 150 35 5 RETURN AIR SPIGOTS (ON RECESSED/CHASSIS UNITS ONLY) Ceiling or Wall Mounted Unit Rectangular Return Air Ceiling or Wall Mounted Unit Circular Return Air s Width Height Depth Size 1 632 164.5 25 Size 2 1135 164.5 25 Pitch Separation Diameter Depth Number of s Size 1 2 x 204.5 150 35 3 Size 2 4 x 218.0 150 35 5 Page 4

FIXING CENTRES & PIPEWORK CONNECTIONS (VIEWED FROM FRONT) Figure 2a Top of Unit 394 mm A 59 mm Side of Unit Base of Unit 227 mm C B Pipework of 15 mm diameter (flow & return pipe centres are 40 mm apart) On the Size 2 water heated units although the connections on to the valve are 15mm it is suggested that pipework size be increased to 22mm running away from to the unit. A Left-Hand Fixing Centre to Right-Hand Fixing Centre B Fixing Centre to Side of Unit C Pipework Centre to Centre of Unit Cased Size 1 562 mm 86 mm 276 mm Size 2 1065 mm 86 mm 527 mm Recessed/Chassis Size 1 562 mm 35 mm 276 mm Size 2 1065 mm 35 mm 527 mm VALVE & PIPEWORK POSITIONING (VIEWED FROM RIGHT HAND SIDE) Figure 2b Front of unit Valve 40 mm 30 mm Back of unit Actuator 66 mm Flow Return Floor 18 mm 85 mm 74 mm Page 5

INSTALLATION STAGES INVOLVED Figures 3 to 8 show how the unit is installed and assembled. Take care not to damage components and accessories when handling them. Before installing the unit check that there will be adequate access space for maintenance (300mm each side). The approximate amount of time needed to install the unit is half a day, plus the time needed to make the fresh air duct hole in the building. Remember that in order to get heating on water heated units, all the air must be bled from the system including the coil in the unit. Figure 3 Width Height Size 1 412 mm 134 mm Size 2 915 mm 134 mm Figure 4 Remove casing in following order: 1. Remove recirc grille access panel. Sharp pull upwards and then out. 2. Remove front access panel. Two screws at bottom. 3 6 4 2 5 6 3. Remove plastic end panels. Two screws per panel. 4. Remove coil access panel. Four Screws. 5. Remove discharge grille and discharge access panel. Two screws. 6. Remove metal side panels. Two screws at front per panel. 3 1 Page 6

Bottom of fresh air spigot 35mm off ground/base of unit Figure 5 1. Connect the fresh air spigot to the L-shaped spigot base, by loosening the L-shaped spigot base from the unit and then slotting the fresh air spigot between the unit and the L- shaped spigot base. Retighten the L-shaped spigot base. 2. Insert the telescopic wall sleeve/lining through the wall. 3. Connect the telescopic wall sleeve/lining to the fresh air spigot. 4. Uncoil the outside temperature sensor cable from the back of the unit, and fix it directly behind the external louvre in the airstream. If necessary extend the cable. 5. Connect the L-shaped spigot base to the wall. 6. Connect the unit to the L- shaped spigot base and to the wall using the brackets. Side Panel Front view Drop rod Top views Screw & Plug The 2 pipe centres are 40mm apart. Note: If installing re-circulation units, simply connect the unit to the wall and do not uncoil or move the outside temperature sensor. Connect unit to mains power, remembering Size 2 electric heated units require a 3-phase supply (refer to pages 9 to 11). Figure 6 Pipework must be connected to unit on LPHW models before replacing casing. Connect unit to remote control pad (refer to page 12). Page 7

Figure 7 Replace casing in the following order. 1. Attach side panels. Two screws at front of panel per panel. 4 1 3 5 2 1 4 2. Attach discharge grille and discharge access panel. Two screws. 3. Attach coil access panel. Four screws. 4. Attach plastic end panels. Two screws per panel. 5. Attach front access panel. Two screws at bottom. 6. Attach re-circulation grille and access panel, push in and pull downwards. 6 Figure 8 Unit installed and ready to operate after louvre has been fitted to outside of building. Page 8

CONNECTING THE UNIT TO MAINS POWER The recommended mains supply cables for Innovair are: Size 1 & 2 water heated units, 3-core mains cable (Cu/PVC/PVC) size 1mm 2 Size 1 electric heated units, 3-core mains cable (Cu/PVC/PVC) size 1.5mm 2 Size 2 electric heated units, 4-core steel wire armoured cable (Cu/PVC/PVC/SWA/PVC) size 1.5mm 2 or single core conduit cable (Cu/PVC) size 1.5mm 2, 3 lives/neutral/earth with suitable size 20mm conduit and fittings. Mains Supply Running Current (Amps) Starting Current (Amps) Water Heated Size 1 230V/~/50Hz 1.0 3.0 Size 2 230V/~/50Hz 2.0 6.0 Electric Heated Size 1 230V/~/50Hz 13.0 3.0 Size 2 400V/3N~/50Hz 9.0 per phase 6.0 The electrics control panel should be accessed by unscrewing the securing screw(s) and lowering the panel into a horizontal position. Size 1 (Water & Electric), Size 2 (Water) Thread the mains power cable through the cable gland on the RHS. Wire to terminals L N E on the connection centre PCB located at the LH end of the electric control panel. See diagram on page 10. Use cable ties provided to secure cables and ensure they are not trapped when hinged panel is replaced. Size 2 (Electric). Thread mains power cable through cable gland plate at LHS of the unit and wire to terminals L 1 L 2 L 3 N and Earth stud at bottom of EMC filter. See wiring diagram. Note that Size 2 electric heated units require a 3-phase supply. Figure 9 Unscrew Screw Wire the mains power cable into the Customer Connection Centre located inside of the Control Panel Page 9

WIRING DIAGRAM CUSTOMER CONNECTION CENTRE Only for Size 1 & 2 Water and Size 1 electric SITE WIRING INNOVAIR CONTROL PANEL Page 10

WIRING DIAGRAM CUSTOMER CONNECTION CENTRE Size 2 Electric units only. Page 11

CONNECTING THE REMOTE CONTROL PAD TO THE UNIT. The remote room controller supplied with the unit should be connected via the customer connection centre at the LHS of the control panel using Non Screened 16/0.2mm (0.5mm 2 ) cable. Cable ties and cable glands are provided to secure cables and ensure that they are not trapped when the hinged cover is replaced. THIS CONNECTION IS VOLTAGE FREE AND SHOULD NOT BE CONNECTED TO ANY OTHER VOLTAGE SOURCE. The Model TE/TS/KEF for manual heating & ventilation adjustment requires 6 cores connected to TE1 TE6. The Model TE/TS/K for manual heating & automatic / no ventilation adjustment requires 3 cores connected to TE1, TE2 & TE3 only. Cables must be connected to the both the customer connection centre and remote control pad using the identically numbered terminal blocks. See Customer connection centre diagram and installation instructions supplied with the control pad for details. CONNECTING UNITS AS MASTER/SLAVE OR SLAVE/SLAVE ARRANGEMENT Master / Slave connection is made via the LON terminal on the Customer Connection Centre. Connection should be made using 2 core Beldon 8471 cable. Cable ties and cable glands are provided to secure cables and ensure that they are not trapped when the hinged cover is replaced. THIS CONNECTION IS VOLTAGE FREE AND SHOULD NOT BE CONNECTED TO ANY OTHER VOLTAGE SOURCE. Cable should be connected from the LON terminal block on the master unit to the LON terminal block on the first slave unit and so on to the other slave units. See Customer connection centre diagram for details. There is no limit to the number of slave units that can be connected to the master unit so long as the Beldon cable does not exceed 100m in length. Page 12

CONNECTING THE UNIT TO A BMS BMS connection is made via the LON terminal on the Customer Connection Centre. Connection should be made using 2 core Beldon 8471 cable. Cable ties and cable glands are provided to secure cables and ensure that they are not trapped when the hinged cover is replaced. THIS CONNECTION IS VOLTAGE FREE AND SHOULD NOT BE CONNECTED TO ANY OTHER VOLTAGE SOURCE. BMS control enables supervisor software to switch units on and off, change software knob settings on the unit, Trend log etc. The basic internal strategy of the unit cannot be amended. See Customer connection centre diagram for details. CONNECTING THE UNIT TO A TIMER CLOCK OR P.I.R. Sensor. Your timer clock or P.I.R. Sensor should be connected to the unit via the customer connection centre using 2 core non screened 16/0.2mm (0.5mm 2 ). Cable ties and cable glands are provided to ensure that the cables are not trapped when the hinged cover is replaced. Cable should be connected to the TIMER terminal block. There must be a separate volt free contact for each Innovair connected to the timer clock or P.I.R. sensor. For multiple installations the timer clock or P.I.R. sensor should operate multiple pole relays, so that each Innovair has its own separate pole/control. THIS CONNECTION IS VOLTAGE FREE AND SHOULD NOT BE CONNECTED TO ANY OTHER VOLTAGE SOURCE. See Customer connection centre diagram for details. Page 13

CONNECTING THE UNIT TO AN EXTRACT &/OR SUPPLY FAN SYSTEM (SINGLE PHASE SUPPLY & RUNNING CURRENT NO GREATER THAN 8A) Where an extract fan or additional supply fan is required in the system, the on/off control can be enabled via the Innovair units. This is achieved using either a delay on or delay off relay controlled via the IQL. The relay can be provided (Optional extra) mounted and wired to the side of the Innovair unit for connection on site using 3 core mains cable size 1.0mm 2 cable. The relays can activate the external fans when the unit is operating in standard ventilation mode, in free cooling mode and during night cooling mode. Figure 10 Wire extract &/or supply fan system into terminal block above damper actuator. Damper actuator Page 14

CONNECTING THE UNIT TO A BIDDLE CO 2 SENSOR The Biddle supplied CO 2 sensor and connection equipment is normally for use on Stand Alone Innovair units and not the BMS type. Each unit is provided with the externally wall mounted sensor and connected to built-in volt sensitive relays and control equipment. Where more than 1 unit is provided in a single controlled space, then only the master unit needs to be controlled via the CO 2 sensor. For Master / Slave connection see page 12. THIS CONNECTION IS VOLTAGE FREE AND SHOULD NOT BE CONNECTED TO ANY OTHER VOLTAGE SOURCE. Terminal block connections for the CO 2 sensor are fitted within the Innovair units inside the electrical control panel on the RHS. Cable should be: Non Screened 16/0.2mm (0.5mm 2 ) for connections G+ & G0 (24v Supply) Screened 16/0.2mm (0.5mm 2 ) for connections OUT1 & M (0 10v Signal) See wiring diagram supplied with units for more information. Page 15

OPERATION Manual / Stand Alone Type Control Pad Heat and Ventilation Figure 11 Controller type: TE/TS/KEF for manual operation of Temperature & Ventilation. Also incorporates a room air temperature sensor Max Button (15mins Maximum heat & vent) Ventilation Slider Control Moon = Off MAX x 0 = On. No ventilation C x 0 x 4 x 2 x 1 x 4 x 2 = On. Max Ventilation (fully occupied room) = On. Half Ventilation (1/2 occupied room) x 1 = On. Min Ventilation (1/4 occupied room) Set point adjuster - (Shown at approx 24 0 C) On/Off & Ventilation Slider. Each new day Reset the ventilation control to the desired level as the unit will automatically default to minimum ( x 1) to save energy. DO NOT SWITCH UNIT OFF AT THE MAINS except in case of emergency Unit Functionality: When the slider is set in the top position indicated by the Moon symbol the unit is effectively switched to OFF or in unoccupied set-back mode. When the slider is set to any other position the unit will be in the ON position or in normal occupied operating mode. Normal occupied operating mode. In this mode the unit is operated to firstly control the level of fresh air ventilation (by cycling of the damper), and secondly to satisfy set point temperature requirements (by heating or free cooling). Page 16

Unoccupied set-back mode. In this mode the unit operates to satisfy the set back temperature or night time cooling requirement only. During occupied operating room temperature is controlled by the set-point adjuster, which can be rotated between the 15 C and the 30 C settings. Ventilation level is controlled by moving the slider to X0, X1, X2, & X4 positions. X 0 position gives heating and no ventilation. X 1 position gives heating and ¼ ventilation or minimum occupancy. X 2 position gives heating and ½ ventilation or ½ occupied X 4 position gives heating and max ventilation or fully occupied room. MAX button. This gives maximum ventilation at high fan speed for 15 minutes only. This is used to refresh the room as quickly as possible. The button must be pressed for a minimum of 2 seconds to operate. Further information about the operation of the unit, the safety features and how the fans, the damper and the water heating valve are used to control ventilation, heating, free and night cooling are available on request. CONTROL PAD - HEAT & RECIRCULATION This is identical to the control pad supplied with the Heat & Ventilation unit, but since there is no fresh air supply the ventilation slider has no effect other than to switch the unit between Normal occupied mode and unoccupied set back mode. Temperature control is still provided by the set-point adjuster and the control pad incorporates a room air temperature sensor. Page 17

Page 18

OPERATION Automatic Ventilation or BMS Figure 12 Controller type: TE/TS/K for manual Temperature & Automatic Ventilation. Also incorporates a room temperature sensor C Set point adjuster - (Shown at approx 24 0 C) DO NOT SWITCH UNIT OFF AT THE MAINS except in times of emergency Unit Functionality: In this format of operation the unit is effectively switched ON or OFF by the use of an external timer, PIR sensor or BMS. See individual connection information. All ventilation rates are controlled automatically and there is no manual control. It is usual to have a CO 2 Sensor mounted in the room with this form of control. This limits the quantity of fresh air to just that required for the occupancy of the room for increased energy efficiency. The Sensor can either be supplied as part of the Innovair unit or as part of the BMS control. If supplied as part of the Innovair Unit See section headed Connection to CO 2 Sensor for more information. Manual adjustment of Room temperature is controlled by the set-point adjuster, which can be rotated between the 15 C and the 30 C settings. BMS control can also be used to remotely re-scale the minimum and maximum set point positions (e.g. 18 C min / 20 C max) for increased energy efficiency. The unit will operate in either Normal occupied operating mode or Unoccupied setback mode as with the Manual / Stand Alone unit. In this mode unit operates to satisfy the set back temperature or night time cooling requirement only. Page 19

MAINTENANCE ACCESS PANEL After removing the re-circulation grille access panel the front access panel is secured by two M5 hexagonal head screws concealed behind the re-circulation grille and re-circulation access panel (refer to figure 4). END PANELS Each end panel is secured by two lugs which locate into rear slots at the side of the unit and then secured by two M5 hexagonal head screws at the front (refer to figure 4). FILTER The filter media is held in a frame, which locates in channel slides behind the re-circulation grille access panel. After removing the re-circulation grille access panel the filter can be withdrawn after undoing the two quarter-turn fasteners and sliding the frame forward. A vacuum cleaner or gentle beating may be used to clean the filter. The period between cleaning is dependent on operating conditions. In a very dirty atmosphere the filter will require frequent cleaning (maybe every few weeks) whereas in a clean environment it may only be necessary every few months. Replacement filter medium is available in 10m rolls for fitting into the frame assembly. FANS & MOTORS Providing the filter is regularly cleaned the fans and motors will require no attention. They can be accessed however by removing the re-circulation grille access panel and the main access panel. Clean using a soft brush and vacuum cleaner. HEATING COIL Providing the filter is regularly cleaned the heating coil will require little or no attention. However if the filter is allowed to get very dirty some dust will percolate through and become entrained in the coil. In this case it can be cleaned by removing the front access panel, the discharge grille, the discharge access panel and the coil access panel and applying a jet of air to the air leaving face. DAMPER AND ACTUATOR The damper requires no maintenance, other than to brush clean occasionally. Located on the left hand side of the unit the damper actuator requires no maintenance and should not be removed from its mounting panel. CASING The interior of the unit should be cleaned occasionally with a soft brush and a vacuum cleaner. On cased units periodically check that the paint is in good condition and repaint when necessary. TOOLS REQUIRED:- 7mm A/F nut spinner Pozidrive 2pt Screwdriver Page 20

UK SALES CONTACTS NORTH EAST : Ken Embleton NORTH WEST : Graham Gee Embleton Enviro. Products Ltd 4 Bar House Row Gear House, Saltmeadows Road Old Pool Bank Gateshead Pool in Wharfdale Newcastle Upon Tyne NE8 3AH Yorkshire LS21 1EW Tel : 0191 490 1155 Tel : 0113 284 3269 Fax : 0191 478 5915 Fax : 0113 284 3269 Mobile : 07860 828317 Mobile : 07977 981117 MIDLANDS : Roger Parker SOUTH WEST : Steve Rowley 184 St Nicholas Park Drive Biddle Air Systems Nuneaton St. Mary s Road Warwickshire Nuneaton CV11 6EQ Warwickshire CV11 5AU Tel : 02476 347364 Tel : 02476 384233 Fax : 02476 347364 Fax : 02476 373621 Mobile : 07831 202567 Mobile : 07977 981116 SOUTH WALES : Dave Dolling SOUTH EAST : Ian Ross South Wales Htg Equipment Ltd 98 Holmesdale Street Grangetown, Cardiff South Glamorgan CF1 7BU Tel : 02920 237654 Mobile: 07977 981123 Fax : 02920 237654 Mobile : 07815 833804 N. IRELAND : Stuart Magee SCOTLAND : Roddy MacDougall Sermet (NI) Ltd Tel: 01236 738511 11 Lisburn Street Fax: 01236 738511 Hillsborough Mobile: 07977 981126 Co. Down BT26 6AB Tel : 02892 682531 Fax : 02892 683933 Page 21

Biddle Air Systems Limited St. Mary s Road, Nuneaton, Warwickshire CV11 5AU Tel: +44 (0) 2476 384233 Fax: +44 (0) 2476 373621 Biddle B.V. PO Box 15, NL-9288 ZG Kootstertille, The Netherlands Tel: +31 (0) 512 335555 Fax: +31 (0) 512 331424 Biddle GmbH Emil-Hoffmann-Strabe 55-59, 50996 Koln, Germany Tel: +49 (0) 2236 380235 Fax: +49 (0) 2236 380239 Biddle 48 rue Denis Papin, 94200 Ivry sur Seine, France Tel: +33 (0) 149 605555 Fax: +33 (0) 149 605556 Biddle NV Business Park E19, Battelsesteenweg 455E, 2800 Mechelen, Belgium Tel: +32 (0) 15 287676 Fax: +32 (0) 15 287677 Page 22