Ultrasound Scientific/Technological fact sheet

Similar documents
FXA UNIT G485 Module Ultrasound. Candidates should be able to :

Hunting Bats. Diagnostic Ultrasound. Ultrasound Real-time modality

An abdominal ultrasound produces a picture of the organs and other structures in the upper abdomen.

BIOMEDICAL ULTRASOUND

Scanning Acoustic Microscopy Training

Copyright 2008 Pearson Education, Inc., publishing as Pearson Addison-Wesley.

Synthetic Sensing: Proximity / Distance Sensors

Ultrasonic Wave Propagation Review

Ultrasound. Sound waves

Describing Sound Waves. Period. Frequency. Parameters used to completely characterize a sound wave. Chapter 3. Period Frequency Amplitude Power

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers

physics 1/12/2016 Chapter 20 Lecture Chapter 20 Traveling Waves

Answer the following questions during or after your study of Wave Properties. 4. How are refraction and the speed of wave in different media related?

TISSUE MIMICKING GEL QUALITY LE PHANTOM SERIES DESIGN. performance the ultrasound labs ofand. icking material has the same attenuation mim-

Ultrasound - Vascular

Principles of Medical Ultrasound. Pai-Chi Li Department of Electrical Engineering National Taiwan University

After a wave passes through a medium, how does the position of that medium compare to its original position?

E190Q Lecture 5 Autonomous Robot Navigation

Ultrasound Technologies. PD1v. vascular pocket doppler. Operating Instructions

Waves Sound and Light

RADIOLOGY SERVICES. By Dr Lim Eng Kok 1

4.4 WAVE CHARACTERISTICS 4.5 WAVE PROPERTIES HW/Study Packet

Various Technics of Liquids and Solids Level Measurements. (Part 3)

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

C1 Medical Imaging Modalities & Characteristics Linwei Wang

Introduction to acoustic imaging

Acousto-optic modulator

APPLICATION NOTE AP050830

Physical Science Study Guide Unit 7 Wave properties and behaviors, electromagnetic spectrum, Doppler Effect

INTERFERENCE OF SOUND WAVES

Ultrasound Distance Measurement

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

Basics of Ultrasound Imaging

Antonio Rampoldi Struttura Complessa di Radiologia Interventistica Azienda Ospedale Niguarda Ca Granda, Milano. Terminology

v = fλ PROGRESSIVE WAVES 1 Candidates should be able to :

1) The time for one cycle of a periodic process is called the A) wavelength. B) period. C) frequency. D) amplitude.

A pulse is a collection of cycles that travel together. the cycles ( on or transmit time), and. the dead time ( off or receive time)

AP1 Waves. (A) frequency (B) wavelength (C) speed (D) intensity. Answer: (A) and (D) frequency and intensity.

X-Rays Benefits and Risks. Techniques that use x-rays

Acoustics: the study of sound waves

How To Use An Ultrasound For Medical Research

X-ray (Radiography) - Abdomen

BASIC PHYSICAL PRINCIPLES OF ULTRASOUND

How Waves Helped Win the War: Radar and Sonar in WWII

3D ACOUTIC SIMULATIONS FOR NONLINEAR ACOUTIC CONCEALED WEAPONS DETECTION

Sound absorption and acoustic surface impedance

WSR - Weather Surveillance Radar

Direct and Reflected: Understanding the Truth with Y-S 3

Patient Prep Information

High-quality/High-resolution Digital Ultrasound Diagnostic Scanner

Chapter 4 Physiological Therapeutics. 3 Therapeutic Ultrasound

The Effects of Ultrasonic Sound Generated by Ultrasonic Cleaning Systems on Human Hearing and Physiology

From lowest energy to highest energy, which of the following correctly orders the different categories of electromagnetic radiation?

Experiment 5. Lasers and laser mode structure

Doppler Effect Plug-in in Music Production and Engineering

PLEASE DO NOT WRITE ON THE TEST. PLACE ALL MULTIPLE CHOICE ANSWERS ON THE SCANTRON. (THANK YOU FOR SAVING A TREE.)

Application of Ultrasound, MRI and PET in Cardiac Disease Diagnosis

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

Robot Perception Continued

Training programme on flow measurements

DIAGNOSTIC MEDICAL IMAGING 1st Part --Introduction. Ing. Tommaso Rossi

Weather Radar Basics

State Newton's second law of motion for a particle, defining carefully each term used.

Mobile use, radio signals and health

INTERFERENCE OF SOUND WAVES

The promise of ultrasonic phased arrays and the role of modeling in specifying systems

X-ray (Radiography) - Bone

Chapter 21 Study Questions Name: Class:

AS COMPETITION PAPER 2008

PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany

MAKING SENSE OF ENERGY Electromagnetic Waves

Using light scattering method to find The surface tension of water

A Measurement of 3-D Water Velocity Components During ROV Tether Simulations in a Test Tank Using Hydroacoustic Doppler Velocimeter

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

Experiment 1: SOUND. The equation used to describe a simple sinusoidal function that propagates in space is given by Y = A o sin(k(x v t))

COLLATED QUESTIONS: ELECTROMAGNETIC RADIATION

Conceptual Physics Review (Chapters 25, 26, 27 & 28) Chapter 25 Describe the period of a pendulum. Describe the characteristics and properties of

Lab Exercise 1: Acoustic Waves

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Level Measurement. Detlef Brumbi Krohne Messtechnik GmbH (11.1)

Acoustic design according to room shape

STAAR Science Tutorial 30 TEK 8.8C: Electromagnetic Waves

STATISTICAL ANALYSIS OF ULTRASOUND ECHO FOR SKIN LESIONS CLASSIFICATION HANNA PIOTRZKOWSKA, JERZY LITNIEWSKI, ELŻBIETA SZYMAŃSKA *, ANDRZEJ NOWICKI

Module 13 : Measurements on Fiber Optic Systems

The Doppler Effect & Hubble

P1 4. Waves and their uses

Electromagnetic (EM) waves. Electric and Magnetic Fields. L 30 Electricity and Magnetism [7] James Clerk Maxwell ( )

PHYSICS 202 Practice Exam Waves, Sound, Reflection and Refraction. Name. Constants and Conversion Factors

Waves-Wave Characteristics

NON-DESTRUCTIVE METHODS. CE 165: Concrete Materials and Concrete Construction

ME 472 Engineering Metrology

Percutaneous Abscess Drainage

Capacitive Proximity Sensors Theory of Operation

Encoded Phased Array Bridge Pin Inspection

The Sonometer The Resonant String and Timbre Change after plucking

8.1 Radio Emission from Solar System objects

Lab 9: The Acousto-Optic Effect

GLOBAL COLLEGE OF ENGINEERING &TECHNOLOGY: YSR DIST. Unit VII Fiber Optics Engineering Physics

Review Vocabulary spectrum: a range of values or properties

Transcription:

Students material Medical Imaging The Glass Patient Ultrasound Scientific/Technological fact sheet Introduction The reflection of sound is used in many applications to determine distances. The sonar or pulse-echo technique where sonar stands for sound navigation ranging is not only used to locate underwater objects, but also in medical imaging. In sonar, a transmitter sends out a sound pulse through the water, and a detector receives its reflection, or echo, a short time later. This time interval is carefully measured, and from it the distance to the reflecting object can be determined since the speed of sound in water is known. Sonar generally makes use of ultrasound frequencies: that is, waves whose frequencies are above 20 khz, beyond the range of human detection. For sonar, the frequencies are typically in the range of 20 khz to 100 khz. One reason for using ultrasound waves, other than the fact that they are inaudible, is that for shorter wavelengths there is less diffraction, so the beam spreads less and smaller objects can be detected. For an obstacle intercepts and reflects a portion of a wave significantly only if the wavelength is less than the size of the object. Indeed, the smallest-sized objects that can be detected are on the order of the wavelength of the wave used. With the higher frequencies of ultrasound, the wavelength is smaller, so smaller objects can be detected. The diagnostic use of ultrasound in medicine is also based on the pulse-echo technique, much like sonar. A high-frequency sound pulse is directed into the body, and its reflections from boundaries or interfaces between organs and other structures and lesions in the body are then detected. By using this technique, tumours and other abnormal growths, or pockets of fluid, can be distinguished, the action of heart valves and the development of a foetus can be examined, and information about various organs of the body, such as the brain, heart, liver and kidneys, can be obtained. Although ultrasound does not replace X-rays, for certain kinds of diagnosis it is more helpful. Some kinds of tissue or fluid are not detected in X-ray photographs, but ultrasound waves are reflected from their boundaries. It is also possible to produce real-time ultrasound images, as if one were watching a movie of a section of the interior of the body. Furthermore, at the low intensity levels used for diagnosis (less than 3 10 4 W/m 2 ), no adverse effects have been reported. The frequencies used in ultrasonic diagnosis are in the range of 1 to 10 MHz. The speed of sound waves in the tissues of the human body averages about 1540 m/s (close to that for water). So, the wavelength of a 1 MHz wave is about λ = v/f = 1540/1 10 6 = 1.5 10 3 m = 1.5 mm. This wavelength sets the limit to the smallest-sized objects that can be detected. Higher frequencies mean shorter wavelengths, and thus in principle a visualisation of finer detail. However, the higher the frequency is, the more the wave is absorbed by the body, and reflections from deeper inside the body are lost. Figure 1 Above: Ultrasound pulse passes through the abdomen, reflecting from surfaces in its path. Middle: Reflected pulses plotted as a function of time (A-scan) when received by the transducer. Time is proportional to distance of travel. The vertical dashed lines point out which reflected pulse goes with which surface. Below: B-mode display for the same echoes: the brightness of each dot is related to signal strength. The pulse-echo technique for medical imaging works as follows. A brief pulse of ultrasound is emitted by a transducer, which is a device that transforms an electrical pulse

into a sound-wave pulse as a loudspeaker does. Part of the pulse is reflected at various interface surfaces in the body, and most (usually) continues on. The detection of the reflected pulses is done by the same transducer, which transforms the sound pulses into electrical pulses as a microphone does. The detected pulses can then be displayed on the screen of a monitor. As an example, consider a sound pulse passing through the abdomen (Figure 1). At various interfaces in the body, part of the pulse is reflected. The time elapsed from when the pulse is emitted to when its reflection (echo) is received is proportional to the distance to the reflecting surface. For example, if the distance from the transducer to the vertebra is 25 cm, the pulse travels a round-trip distance of 2 0.25 = 0.50 m, and the time taken is t = d/v = 0.50/1540 = 3.2 10 4 s = 320 µs. A pulse reflected from an object only 10 cm from the transducer would de received after only 130 µs. For the situation shown in Figure 1, the reflected pulses are plotted as a function of the time they are received by the transducer. The strength of a reflected pulse depends mainly on the differences in density of the two materials on either side of the interface. It also depends on the sound velocity in each material, but this normally has little effect since in most tissues the velocity is within a few percent of the average 1540 m/s. Exceptions are bone (4000 m/s) and air (340 m/s). At interfaces involving bone or the lungs, most of the sound pulse is reflected. So, ultrasound cannot be used as a probe beyond such interfaces. Also, generally the transducer is placed in contact with a person s body, or the body and transducer are immersed in water, so as to avoid the high reflectivity at the first air-body interface, which would greatly reduce the amount of sound waves passing into the body. A trace such as shown in Figure 1 can be displayed directly on a monitor (Figure 2). Such a display is called an A-scan or A-mode scan. Far more common today is a B-scan, which can be used to form 2D images of a cross section of the body. In a B-mode scan, each echo is represented as a point, whose position is given by the time delay and whose brightness depends on the strength of the echo (Figure 1). A 2D image can be formed from a series of B-scans. The transducer is moved, and at each position it sends out a pulse and receives echoes as shown in Figure 3. Each B-scan trace can be plotted, spaced appropriately one below the other, to form an image on a display terminal. Only ten lines are shown in Figure 3, so the image is crude. More lines give a more precise image. A faster scan can be obtained by using an array of transducers, or by rotating a single transducer about a point so it looks in a sequence of different directions through the body. Figure 2 An A-scan of an eye. Figure 3 Above: Ten traces are made across the abdomen by moving the transducer, or by using an array of transducers. Below: The echoes are plotted to produce the image. More closely spaced traces would give a more detailed image. Reference Adapted from Giancoli, Douglas C. (1998), Physics: principles with applications (5 th edition, pp. 370-374). Upper Saddle River, NJ: Prentice Hall. Ultrasound imaging in medicine began during and shortly after World War 2. In the USA Holmes & Howry experimented with water tanks to achieve acoustic coupling when trying to obtain detailed images of soft tissues (Figure 4). From the mid 1960s onwards, the advent of commercially available systems allowed the wider dissemination of the technique. Rapid technological advances in electronics and piezoelectric materials provided further improvements. Today ultrasound is by far the most used medical imaging technique in the world, since it is relatively cheap as compared to MRI or CT, safe, non-invasive and painless. The best-known application of ultrasound is

pregnancy (Figure 5): the examination is not harmful at all to the foetus. The use of X-rays or radioactive tracers, however, would give rise to a higher probability to induction of cancer. This is especially so for foetuses or babies, as radiation damage is most likely to occur in fast dividing cells. Figure 4 Early ultrasound image of the normal neck made by Holmes & Howry in 1956. The volunteer was submerged in degassed water and scanned through 360. Figure 5 Ultrasound image of a 35 weeks old human foetus (with head at the right) within the uterus. Image formation The ultrasound source is a transducer: a piezoelectric crystal. If a voltage is put across such a crystal, it compresses. Therefore, an alternating voltage generates causes the crystal to oscillate and produce pressure waves or sound waves. The crystal not only converts an electric signal into a mechanical motion, but also the other way around. Therefore, the transducer can also be used as a sound wave detector. If the ultrasound waves travel through matter with a higher density (with the molecules closer together), the wave velocity is higher (Figure 6). For example, the wave velocity in gas (air) is 340 m/s, while that in water is 1560 m/s. That is easy to understand when one considers vibrations in matter in which molecules have a larger chance to interact with other molecules, as is the case in dense tissues. Large differences in densities at the boundary of two tissues cause reflection of the pressure waves (Figure 7). In the body reflections (or echoes) arise at the boundaries of different tissues. Hence, the anatomy of different organs can be visualised, if we are able to measure the reflections. The transducer not only emits ultrasound waves into the patient, it also receives the reflected waves. Reflections from deeper in the tissue have travelled a larger distance, both on the path from transducer to the density border and on the way back to the transducer. Therefore, the time delays between emission and detection vary with depth. With the help of these small time delays, the corresponding depths can be calculated and an image can be reconstructed. Since the transducer cannot function as both an emitter and a detector at the same time, the signal has to be pulsed. So the transducer only functions as a detector between two pulses. Figure 6 Ranges of measured values for the speed of sound in various biological and non-biological media. The data for soft tissues and biological liquids fall within a narrow range. Figure 7 Scattering reflection and refraction at a boundary surface between two media, of characteristic acoustic impedances Z 1 and Z 2 and speeds of sound c 1 and c 2. The intensity of the reflected waves is described by the greyscale of the ultrasound image: the stronger the reflection that comes from a certain depth, the lighter the pixel is. Locations in smooth tissue having the same overall density (so, little or no reflecting surfaces) are therefore black.

Transducers can be divided into two classes of different frequencies: low frequency transducers (2.5-5 MHz) which are used to visualise tissues at larger penetration depths, and high frequency transducers (7.5-10 MHz) which offer a better resolution at superficial depths. In ultrasound imaging air is the best contrast agent. Since it has a much lower wave velocity than all human tissues, reflections on air are strong. Recently, injectable contrast media with micro bubbles (less than 10 µm in diameter) have appeared on the market. These are small protein bubble membranes filled with air or perfluorocarbon to be used for visualising blood vessels. 3D Ultrasound A 3D ultrasound image is made with a special 3D transducer. This sector transducer has an array of small transducers emitting planar waves as a function of time in the tissue (Figure 8). The resulting wave front has a specific direction, depending on the time delays in the transducer array. By varying these time delays, the direction of the wave front can be changed. Thus reflections from different directions can be measured, from which a 3D ultrasound image is built on the same principles as in 2D. Figure 8 Left: Phased array ultrasound probe. Middle and right: Examples of a 3D ultrasound image: face and hands, ear of a foetus. Doppler Ultrasound The most commonly used ultrasonic flow measurement technique is called Doppler Ultrasound. The Doppler shift is the phenomenon that the frequency of a wave depends on the relative velocity between the emitter and detector of the wave compare this to the change in pitch of the horn of a passing ambulance. Suppose red blood cells, for example, move with velocity v and direction θ with respect to the direction of the transmitted ultrasound waves (Figure 9). The result is a shift in frequency of the backscattered ultrasound waves the blood cells act like a moving source of (reflected) ultrasound waves. Figure 9 Doppler ultrasound system illustrating the angle θ appearing in the backscatter Doppler equation. Figure 10 Examples of Doppler ultrasound flow measurement. The (false) red colour represents a flow away from the user, the blue colour a flow towards the user compare this to the red shift of galaxies. This Doppler shift f can be measured and used to calculate the velocity v of the red blood cells from the following equation: f = ±(2 f 0 v cosθ )/c

In this expression f 0 is the frequency emitted by the transducer, and c is the velocity of sound in the tissue. This technique is used for studying blood flow behaviour in vessels (Figure 10), including the beating of the heart. Because the frequency shift of 0-200 Hz lies in the audible frequency range, a common method for subjective interpretation of Doppler-shift signals from moving blood is to amplify the signals and just listen to them. Physics principles Sound waves: frequency, wavelength, velocity, absorption, reflection, echo, wave front, Doppler shift. Additional links http://electronics.howstuffworks.com/ultrasound.htm