Fire Safety Compliance Guide: Wall and Ceiling Linings

Similar documents
Steel-framed Walls. Insulation

Fire testing for BCA compliance

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

The Kingspan Insulation Price List 1 st January 2013

Timber Frame Walls Rethinking Construction

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

THERMAL BARRIERS FOR THE SPRAY POLYURETHANE FOAM INDUSTRY

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

Composite Panel Firewall Systems

Australian/New Zealand Standard

Meeting the Fire Code with Continuous Foam Plastic Insulation

Insulation R-Value Comparisons

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

Loss Prevention Standard

Information Bulletin. Sprinkler System Component Fault Monitoring. Version 1.1 Approved for release September 2013

Colorcoat Technical Paper Fire performance of pre-finished steel cladding systems

COMMERCIAL BUILDING APPLICATIONS

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.

03/05/14 REVISOR RSI/JC RD3945

IFE Level 4 Certificate in Fire Science and Fire Safety (HL)

Installation Instructions

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

Fire Safety Requirements for Child Care Centre

FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS

Fire Testing of Recycled Materials for Building Applications

The Real Value of Space

Renovating Your Basement

Module 3.7. Thermal bridging

How To Build A Two Hour Firewall In Calgary

Wood use in Type I and II (noncombustible) construction

In accordance with NFPA 30, these containers are not to store Class I flammable liquids.

Loss Prevention Standard

A new approach to the Danish guidelines for fire protection of combustible insulation

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

Prefabricated building PVC vertical sliding window

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

Introduction. Facade Fire Test on PUR External Thermal Insulation Composite System (ETICS)

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

WHS LEGISLATIVE COMPLIANCE GUIDELINES

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

Rockwool Flexi Insulation Application Guide

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Fiberglas, Exterior Wall Thermal Insulation

ISO Types 1-6: Construction Code Descriptions

CHAPTER 7: Building Systems ROOFING SYSTEMS

Heat Treatment Process

Fire-Retardant-Treated (FRT) Plywood

Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction

Queensland Development Code Mandatory Part 6.1 Commissioning and maintenance of fire safety installation

Fire safety in timber buildings

LINCOLNSHIRE FIRE AND RESCUE

Housing Fact Sheets. Insulation Check-Up

Annex of the certificate (Page 1/6) Accreditation Scope

Energy Company Obligation (ECO): Technical Monitoring Questions

Flame Spread Performance of Wood Products

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

BER Assessors Dwellings Technical Bulletin

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

Multi-layer Insulation Blanket for Roofs

Low-slope reroofing guidelines

Terms and Definitions In Canada

Wood-frame Construction, Fire Resistance and Sound Transmission

Decree of the Ministry of the Environment. on fire safety of garages

fire separating walls #2

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

SANDWICH PANEL FILLING MATERIALS

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

FIRE RESISTANCE. Fire Resistance Requirements in Australia, and how to choose the right EWPAA Certified Product to Comply with the BCA

Underwriters Laboratories Testing Information

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

- Version 2 Total R-value calculations for typical building applications

PB301 July Lightweight Building Solutions. Bushfire Protection.

Examples of construction classifications used in the insurance industry

Denver Fire Department Idle Pallet Storage Guidelines Per NFPA 13_Chpt 12

FIRE LOSS STATISTICAL CONSIDERATIONS IN RELATING FAILURE AND BUILDING DAMAGE TO THE BUILDING CODE OBJECTIVES

ROXUL COMMERCIAL ROOFING. Understanding Climate Requirements That Drive Performance. roxul.com

IEQ-15 Air Distribution System

Decree of the Ministry of the Environment on fire safety of ventilation systems

Site and Storage Conditions for Class 3.1 Flammable Liquids

A GUIDE TO WINDOW AND DOOR SELECTION

Approval Standard for Plastic Suspended Ceiling Panels

Safe Operating Procedure

technology UICK progressive sustainable any design, any shape, any colour, anywhere you like!

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.

Testing Rules for Thermal Conductivity October 2015

The FIRE BOOK. Passive fire protection solutions

Polyurethane Products

Approval Standard for Class 1 Fire Rating of Building Panels or Interior Finish Materials

I n s u l a t i o n. Eighth Issue July 2014 BREEAM 2011 PRODUCTS ACHIEVE? KOOLDUCT & THERMA TM. Low Energy Low Carbon Buildings

Fire-Rated Glass and Glazing START

Transcription:

Insulation A4/8 AW2140 Issue 2 Nov 2016 Fire Safety Compliance Guide: Wall and Ceiling Linings FOR WAREHOUSES AND COMMERCIAL OR INDUSTRIAL SHEDS WHERE THE INSULATION ACTS AS THE WALL OR CEILING LINING

Background and Introduction Is exposed insulation in warehouses and commercial or industrial sheds considered a wall or ceiling lining? If so, what fire performance requirements does it need to meet to demonstrate compliance with the deemedto-satisfy provisions of the National Construction Code s (NCC) Building Code of Australia (BCA)? To help answer these important questions Kingspan Insulation engaged independent chartered professional fire safety engineer, Ignis Solutions, to produce a Fire Safety Evaluation. The report assesses the fire safety Performance Requirements of the NCC BCA Volume One to help clarify the definitions, intent and deemed-to-satisfy compliance requirements for exposed insulation in walls and ceilings. It also details the relevant Australian Standards as well as the appropriate test methods that should be applied. fire safety evaluation Client: Kingspan Insulation Pty Ltd Project: 4114 Version: Issue 01 Revision 00 Site: Wall and Ceiling Lining Date: 14 July 2016 chartered professional fire safety engineering consultancy This Technical Bulletin combines guidance from the Ignis Solutions report with some proprietary information from Kingspan Insulation. Note: This document is a guide only. Fire safety requirements and final designs should always be checked against the NCC for compliance. Kingspan Insulation Pty Ltd accepts no responsibility or liability for parties acting solely on the basis of information presented in this guide. 2

Fire Performance Requirements for Wall and Ceiling Linings What is a wall or ceiling lining? Is insulation considered a wall or ceiling lining if it s left exposed to the interior? A lining is any material installed in a wall or ceiling that is exposed to the internal compartment of a building. Yes, it is because it is left exposed. If plasterboard, for example, is used to line the internal side of the wall or ceiling, then the plasterboard would be considered the lining material. However, when no plasterboard is installed, the insulation left exposed will be considered the lining material. In a fire event, the lining material s resistance to spread of flame and fire development is what will help keep the fire contained within the internal compartment of a building, and allow time to evacuate the area safely. What are the NCC fire performance requirements for wall and ceiling linings? The deemed-to-satisfy provisions of the NCC require any wall or ceiling lining material to achieve a Group Number of Group 3 or better. If a material or an assembly is used as a wall or ceiling lining, where it is exposed to the compartment it must achieve a Group Number Ignis Solutions NCC reference: BCA Vol. One, Specification C1.10 Clause 4. What is a Group Number? A Group Number is a fire hazard property classification which is calculated based on test results. Group Numbers range from Group 1 to Group 4, with a Group 1 classification being the best performance. How is a Group Number achieved? A Group Number is achieved in accordance with AS 5637.1, which is referenced in the NCC. Under this standard, a Group Number can be achieved from tests to either AS ISO 9705, AS/NZS 3837 or ISO 5660.1. NCC reference: BCA Vol. One, Specification C1.10 Clause 4. Provision C1.10 AS 5637.1:2010 ISO 9705 ISO 5660.1 AS/NZS 3837 room test predicated test predicated test Figure 1 Hierarchy of fire hazard property testing for internal lining compliance. 3

What are the differences in the test methods? AS/NZS 3837 and ISO 5660.1 are small scale tests using only a small specimen of material. They are considered predictive tests as the results can be empirically correlated to how the material might behave in a large scale fire, depending on the material. AS ISO 9705, on the other hand, is a full scale fire test conducted in a fire test room 3.6 m long x 2.4 m wide x 2.4 m high, which is installed with the material. It tests how a material behaves in an actual full scale fire event. Which test method is the right one? It depends on the type of material being used. If a material, product or assembly possesses any of the following characteristics, then AS ISO 9705 must be used: a) It has profiled facings not allowed by AS/NZS 3837; b) It contains materials that melt of shrink away from a flame; c) It has joints or openings; and d) It has a reflective surface. Testing to AS/NZS 3837 or ISO 5660.1 to claim a Group Number is only allowed when the material is: a) Painted or unpainted paper-faced gypsum plasterboard; b) Solid timber and wood products such as particleboard and plywood; or c) Rigid non-thermoplastic foams such as polyurethane (homogenous material without foil facing). Reference: AS 5637.1, Clause 5.3.2, Clause 5.3.3. Group number AS 5637 AS ISO 9705 with profiled facings not allowed by AS/NZS 3837; that contain materials that melt or shrink away from a flame; with joints or openings; and with a relfective surface. AS/NZS 3837 / ISO 5660.1 painted or unpainted paper-faced gypsum plasterboard; solid timber and wood products such as particleboard and plywood; and rigid non-thermoplastic foams such as polyurethane. Figure 2 Summary of the test method selection path. 4

What common insulation products need AS ISO 9705 testing to achieve a Group Number? Common insulation products that require testing to AS ISO 9705 to achieve a Group Number include: Foil-faced glasswool insulation blanket; Foil sarking; Reflective insulation; Expanded or extruded polystyrene; Insulated sandwich panels; Foil-faced rigid phenolic or PIR boards. A pliable membrane used as a building internal lining on a wall or ceiling requires an appropriate Group Number tested to ISO 9705 Ignis Solutions Why is small scale testing to AS/NZS 3837 or ISO 5660.1 not acceptable for these products? Because it has been recognised by regulators that there is very poor correlation between the small scale tests and how these products would perform in a real full scale fire. For example, the foil facing on composite insulation products can protect the insulation in the early stages of the small scale AS/NZS 3837 test. In the large scale AS ISO 9705 test, however, due to the involvement of more material and the confines of the test room, there can be much greater heat development which can lead to an earlier flashover than predicted in the small scale AS/NZS 3837 test. Temperatures could get higher than 750 C, at which point even glasswool and materials considered non-combustible may burn. Therefore the large scale AS ISO 9705 test gives a far more accurate representation of a material s fire resistance properties. So because the performance of these products in the small scale AS/NZS 3837 test is not indicative of the material s true performance in a real full scale fire, they cannot claim a Group Number based on it. Instead, they must be tested to AS ISO 9705. 5

Fire Performance Requirements for Wall and Ceiling Linings What if a supplier of one of these products claims a Group Number based on AS/NZS 3837 or ISO 5660.1 testing? What Group Number do I need for warehouses and commercial or industrial sheds? It would not comply with AS 5637.1 and the deemed-to-satisfy provisions of the NCC. To minimise your risks, you should reject it and demand an AS ISO 9705 test report. NCC reference: BCA Vol. One, Specification C1.10 Clause 4. Group 1, 2 or 3, depending on which part of the building the insulation is installed in and whether or not the area is sprinklered. Full details of these conditions and minimum Group Number requirements are available from Table 3 of Specification C1.10 of the NCC BCA Volume One. NCC reference: BCA Vol. One, Specification C1.10, Table 3. Does Kingspan have a compliant product for these building types? Yes, Kingspan AIR-CELL Insuliner TM. This latest innovation from Kingspan achieves a Group 2 classification when tested to AS ISO 9705. Warehouses and commercial or industrial sheds are steel buildings. Do they need an R0.2 thermal break? No. Because the vast majority of warehouses and commercial or industrial sheds are not air-conditioned or heated, the NCC does not require a thermal break. In the rare occasion that this type of building has a heating or cooling system installed, which has an energy input of more than 15 W/m 2, then a thermal break would be required. NCC reference: BCA Vol. One, A1.1, J1.3, J1.5. 6

Kingspan AIR-CELL Insuliner TM is an Australian-made reflective insulation designed specifically for warehouses and commercial or industrial sheds where the insulation acts as the wall or ceiling lining. It is manufactured with a patented physically cross-linked, closed-cell insulation core sandwiched by highly reflective foil facings. According to AS 5637.1, because the product has a reflective surface, it must be tested to AS ISO 9705 for determination of a Group Number. Kingspan AIR-CELL Insuliner TM achieves Group 2 and is the only reflective insulation product in Australia which achieves a Group Number better than Group 4 i. It can therefore be used to demonstrate deemed-to-satisfy compliance to the NCC fire performance requirements ii in warehouses and commercial or industrial sheds where conventional internal wall or ceiling linings are not applied. Fire Performance Characteristic Standard Classification NCC Group Number AS ISO 9705 Group 2 Flammability Index AS 1530.2 5 What does Group 2 mean? A Group 2 fire performance classification means that the product can be used in most areas of buildings apart from fire-isolated exits and fire control rooms. It also means that a sprinkler system is not required, which can be a significant saving. Full details of installed locations, conditions and minimum Group Number requirements are available from Table 3 of Specification C1.10 of the NCC BCA Volume One. Kingspan AIR-CELL Insuliner TM achieves Group 2 and is the only pliable reflective insulation membrane in Australia which achieves a Group Number better than Group 4 i. It can therefore be used to demonstrate deemed-to-satisfy compliance to the NCC fire performance requirements ii in warehouses and commercial or industrial sheds where conventional internal wall or ceiling linings are not applied. Figure 3 Physically cross-linked Kingspan AIR-CELL Insuliner TM i Correct at time of publishing based on information in the public domain. ii NCC BCA Vol. One, Specification C1.10. 7

Contact Details General Enquiries Tel: 1300 247 235 Email: info@kingspaninsulation.com.au Kingspan Insulation Pty. Ltd. reserves the right to amend product specifications without prior notice. The information, technical details and fixing instructions etc. included in this literature are given in good faith and apply to uses described. Recommendations for use should be verified as to the suitability and compliance with actual requirements, specifications and any applicable laws and regulations. For other applications or conditions of use, Kingspan Insulation offers a Technical Advisory Service the advice of which should be sought for uses of Kingspan Insulation products that are not specifically described herein. Please check that your copy of the literature is current by contacting us or visiting www.kingspaninsulation.com.au Kingspan Insulation Pty Ltd Tel: 1300 247 235 Email: info@kingspaninsulation.com.au www.kingspaninsulation.com.au Kingspan, Kooltherm, the zo Device and the Lion Device are Registered Trademarks of the Kingspan Group plc in Australia and other countries. All rights reserved. Kingspan Insulation Pty Ltd