Queensland Development Code Mandatory Part 6.1 Commissioning and maintenance of fire safety installation
|
|
|
- Isaac O’Connor’
- 10 years ago
- Views:
Transcription
1 Queensland Development Code Mandatory Part 6.1 Commissioning and maintenance of fire safety installation Guideline A guide to assist with achieving compliance with the Building Act 1975 and the Building Fire Safety Regulation 2008 December 2011
2 Looking forward and delivering now integrated planning, strong local government and development for a growing state. State of Queensland. Published by the Department of Local Government and Planning, December 2011, 100 George Street, Brisbane Qld The Queensland Government supports and encourages the dissemination and exchange of information. However, copyright protects this publication. The State of Queensland has no objection to this material being reproduced, made available online or electronically but only if it is recognised as the owner of the copyright and this material remains unaltered. Copyright inquiries about this publication should be directed to the department s Legal Services division via [email protected] or in writing to PO Box 15009, City East, Queensland The Queensland Government is committed to providing accessible services to Queenslanders of all cultural and linguistic backgrounds. If you have difficulty understanding this publication and need a translator, please call the Translating and Interpreting Service (TIS National) on and ask them to telephone the Queensland Department of Local Government and Planning on Disclaimer: While every care has been taken in preparing this publication, the State of Queensland accepts no responsibility for decisions or actions taken as a result of any data, information, statement or advice, expressed or implied, contained within. To the best of our knowledge, the content was correct at the time of publishing. Any references to legislation are not an interpretation of the law. They are to be used as a guide only. The information in this publication is general and does not take into account individual circumstances or situations. Where appropriate, independent legal advice should be sought.
3 Contents Preamble Purpose Background Who can carry out commissioning or maintenance? Maintenance of existing buildings Alternative solutions Frequency of testing for selected passive fire safety installations Fire doors Common defects of fire doors Asbestos in fire doors Battery operated fire alarms Changing standards The occupier s statement Buildings with several tenancies Keeping records safe Critical defect notices Body corporate obligations Fire blankets Legislation...24 Commissioning and maintenance fire safety installation guideline - 1 -
4 Preamble Building fire safety maintenance standards were transferred from the Building Fire Safety Regulation 2008 (BFSR) into the Queensland Development Code (QDC). Standards for the maintenance of fire safety installations are now contained in Mandatory Part (MP) 6.1 Commissioning and maintenance of fire safety installations. MP 6.1 has been developed to set appropriate performance standards for both commissioning and maintenance of prescribed fire safety installations for the safe occupation of buildings and to specify the records that are required. This guideline is issued under section 258 of the Building Act 1975 (the Act). Section 258 allows for guidelines to be made to ensure compliance with the Act. Because the appropriately qualified person who maintains a prescribed fire safety installation is a licensee who is either licensed by the Plumbing Industry Council or the Queensland Building Services Authority, the requirements surrounding licensing must be met as set out in the Plumbing and Drainage Act 2002; and Queensland Building Services Authority Act Commissioning and maintenance fire safety installation guideline - 2 -
5 1. Purpose The purpose of this guideline is to assist building owners and occupiers to understand obligations for complying with the relevant Acts and Regulations for fire safety installations. Commissioning and maintenance fire safety installation guideline - 3 -
6 2. Background State legislation relating to the maintenance of fire safety installations for buildings was introduced in Queensland in 1992 in the Building Fire Safety Regulation 1991 (BFSR now repealed). The Queensland Development Code (QDC) contains maintenance standards which have been transferred from the BFSR. The QDC has recently included standards for commissioning of water-based fire safety installations. The penalties for failure to comply with MP 6.1 remain in the Building Act 1975, the Fire and Rescue Act 1990 (FRA) and the BFSR. All include significant monetary penalties and potentially jail terms if death or injury occurs due to failure to maintain a building s fire safety features. MP 6.1 applies to maintenance of fire safety installations required for a building other than: a class 1a building; a class 10 building associated with a class 1a building; a building treated as part of a coal mine for the purposes of the Coal Mining Safety and Health Act 1999 or as part of a mine for the purposes of the Mining and Quarrying Safety and Health Act 1999; and for the commissioning of fire safety installations required for a building other than a class 1a building; or a class 10 building associated with a class 1a building. Note: 1. For additional requirements in relation to the maintenance of fire safety installations, see the Building Fire Safety Regulation For additional requirements in relation to the commissioning of fire safety installations, see the Building Act 1975 and the BCA, E1. Prescribed fire safety installations are services and equipment required by the Act to safeguard occupants from illness or injury while evacuating during a fire and to provide facilities for occupants and Queensland Fire and Rescue Service (QFRS) to undertake fire-fighting operations. These installations can also prevent the spread of fire between floors or compartments of a building. If you have a prescribed fire safety installation in your building you must comply with the code. Additional requirements to comply with a testing procedure and record results on an approved form also exist for water-based fire safety installations (a subset of prescribed fire safety installations). Furthermore, it is important to understand how you can identify if your building has prescribed fire safety installations. If your building has any of the fire safety installations that are prescribed and listed below then you must comply with the code. Fire protection systems: air-handling systems Commissioning and maintenance fire safety installation guideline - 4 -
7 fire detection and alarm systems smoke and heat venting systems smoke exhaust systems special automatic fire suppression systems (including foam, deluge and gas flooding systems) sprinklers (including wall-wetting sprinklers) stairwell pressurisation systems. Fire fighting equipment: fire extinguishers (portable) fire hose reels fire hydrants (including hydrant boosters) fire mains. Occupant safety features: emergency lifts emergency lighting emergency power supply emergency warning and intercommunication systems exit door hardware exit signs fire doors smoke proof doors solid core doors. Other features: services provided under conditions imposed under section 79 of the Building Act 1975 services required under the Building Code of Australia (BCA), clause E1.10 features required as part of a building s alternative solution vehicular access for large isolated buildings. If you are unsure of whether your building has any of the above systems, you should look at the plans and specifications which were approved as part of the building s approval. The building owner should have a copy of these plans and the building s Certificate of Classification. Alternatively, the local government should have a copy of the building s approval records in their files. Where records are not available, you should contact a building certifier or your local government to confirm the requirements for your building. A building certifier will be able to identify your building s classification and by using the date of approval and the applicable legislation and codes, the prescribed fire safety installation can be ascertained. Please note that the expression test is used in this guideline to include any of the relevant inspections and maintenance of the prescribed fire safety installations and Commissioning and maintenance fire safety installation guideline - 5 -
8 the procedure used to confirm the fire safety installation complies with the specified requirements for acceptability. It is a requirement of the Building Fire Safety Regulation 2008 that the occupier of a building must ensure that the maintenance of each prescribed fire safety installation for the building is carried out by an appropriately qualified person. Commissioning and maintenance fire safety installation guideline - 6 -
9 3. Who can carry out commissioning or maintenance? Additionally, for commissioning, the inspecting and testing of newly installed waterbased fire safety installations must be carried out by an appropriately qualified person. An appropriately qualified person can only carry out commissioning or maintenance on a prescribed fire safety installation if they are licensed to do the work by the Queensland Building Services Authority (QBSA) or the Plumbing Industry Council (PIC). For example, a plumber who is licensed by the PIC to work on fire hydrant or fire sprinkler systems is not authorised to do work on air handling systems unless they also hold the relevant licence from the QBSA. From 1 January 2012, it is a mandatory requirement under MP 6.1 that an appropriately qualified person carrying out commissioning or maintenance of a fire hydrant or fire sprinkler system using a McCrometer must: carry out the commissioning or maintenance in compliance with the document called Fire hydrant and sprinkler system commissioning and periodic test procedure published by the Department of Local Government and Planning record the water pressure and flow testing results using the approved form (Form 70) and in accordance with all relevant Australian Standards. The procedure and Form 70 can be downloaded from the department s website When a building occupier arranges for maintenance to be undertaken, the appropriately qualified person (i.e. licensed contractor) must be advised of the age of the building and provided with copies of the approved plans and Certificate of Classification, so that the appropriately qualified person has an understanding of the building s construction and the legislation that applies. For information on the different licences required for maintenance of fire safety installations please contact the Queensland Building Services Authority on or or for occupational licensing requirements the Plumbing Industry Council on or Commissioning and maintenance fire safety installation guideline - 7 -
10 4. Maintenance of existing buildings Prior to the introduction of MP 6.1, buildings other than class 1a and class 10 were to be maintained against Australian Standard (AS) Maintenance of fire protection systems and equipment. MP 6.1 allows occupiers to choose from a range of specified standards and this allows for a more flexible regime for maintaining older buildings. Fire safety installations must be capable of performing to a standard no less than that which they were originally required to achieve. This means that an occupier of a building that was constructed after 12 September 2005 must ensure the building is maintained against: AS for prescribed fire safety installations other than passive fire safety installations, fire blankets and emergency lighting Schedule 1 of MP 6.1 for fire-doors, smoke doors and fire shutters AS/NZS Emergency evacuation lighting for buildings Inspection and maintenance for emergency lighting an alternative solution that specifies maintenance requirements which are inconsistent with the above standards. If a building was constructed before 12 September 2005, the building occupier has the following options to comply with the code: comply with the maintenance requirements of AS and schedule 1 of the QDC comply with the maintenance requirements of a relevant Australia Standard which was applicable on the day the building was approved where there was no Australian Standard for maintenance at the time of building approval, then recommendations from an appropriately qualified person to carry out maintenance must be followed. Occupiers must make a decision about the Australian Standard that they are going to reference for maintaining the building. This standard should be identified and recorded in the building s yearly occupier s statement so that everyone involved in the maintenance of the building is aware of the standard that is being applied. Industry workers are likely to be most familiar with the latest Australian Standards for maintenance, therefore if the latest Australian Standard has not been identified as the standard for maintenance, it is recommended that the occupier keeps a copy of the older standard available in the building for licensed contractors to use. Australian Standards are published by SAI Global. To purchase a standard please contact SAI Global on or Commissioning and maintenance fire safety installation guideline - 8 -
11 Example 1 Palmview Apartment building was constructed in 1994 and has a fire hydrant system. The body corporate, being the occupier, has chosen to maintain the building s fire hydrants against AS Maintenance of fire protection systems fire hydrants, because this was the Australian Standard applicable on the day the building was approved. In this instance, the body corporate would be required to complete the full six-year cycle of maintenance on the system before they could change the standard being applied to the system. Example 2 Cityside Place is an office building which was approved for construction in Cityside Place has an automatic fire sprinkler system. As the building was approved for construction after 12 September 2005, the sprinkler system is maintained in compliance with AS Example 3 Country Inn Hotel was constructed in 1953 and has three prescribed fire doors installed. At the time of construction there were no maintenance standards for fire doors. A licensed contractor who specialises in fire door maintenance has been engaged to determine how the fire doors can be tested and maintained. The licensed contractor has developed a maintenance regime which is similar to the requirements of AS which they consider as adequate to maintain the performance of: door hardware including self-closing mechanisms and hinges door leaves general delamination, buckling, warping, bowing, twisting or damage gaps between the door and the door frame. Following the licensed contractor s recommendations will mean the occupier complies with the commissioning and maintenance code. Commissioning and maintenance fire safety installation guideline - 9 -
12 5. Alternative solutions Some buildings have been constructed using an alternative solution to meet the performance criteria of the National Construction Code (NCC) Volume 1. A building occupier can find out if a building has an alternative solution by reviewing the building s Certificate of Classification, which is on display at the entrance of a building for buildings constructed after 1 July For buildings constructed with a variation before this date, information should be available through the local government if the current owner does not have a copy of the building s approval documentation. In some instances fire safety installations which are required as part of an alternative solution may have a maintenance regime that has different or extra requirements to the Australian Standards mentioned above. In this situation, the building maintenance regime should comply with the alternative solution to the extent of any inconsistency. It is important to note that if a building occupier is using a particular relevant standard, then there is no need to change current practices. For example, if an older building has been maintained without any problems in accordance with the current standard, then it would be recommended to continue using the more current standard. The more current standard may have some safety or efficiency improvements when compared to the earlier standard. It is also important to remember that there may be a cycle of maintenance that needs to be completed. Recently, the Sustainable Planning Regulation 2009, Schedule 7 was amended to introduce the QFRS as a concurrence referral agency for alternative solutions for performance criteria 3 5. Commissioning and maintenance fire safety installation guideline
13 6. Frequency of testing for selected passive fire safety installations An active maintenance regime is not required for some passive fire safety installations. The QDC acknowledges the practical problems in complying with the frequency of inspections and access to passive fire safety installations listed in AS The frequency of required testing and inspections for passive fire safety installations are listed in schedule 1 of the QDC. The frequency of inspection is six-monthly and yearly, depending on the building classification. A building occupier may decide to increase the frequency by using the testing frequency mentioned in AS if practices or uses are considered to warrant this. However, the regulations only require the testing frequencies in schedule 2 to be followed. Even though there is no active maintenance regime required in the QDC for some passive fire installations such as floors and walls, the occupier should still be aware that it is a breach of the Act to carry out building work without complying with the requirements of the Act. For example, a body corporate might engage a data cabling or pay television company to install cabling and the contracted worker may wish to create a penetration through fire walls or floors. This is not permitted without building approval. If the openings around the penetration are too large or have not been fire stopped in accordance with the building code, the building s fire safety will be compromised. Note: The Fire and Rescue Service Act 1990 (the Act) section 104D states that "The occupier of a building must maintain at all times every prescribed fire safety installation to a standard of safety and reliability in the event of fire". All structural features that are fire safety installations, such as passive fire systems, are required to comply with this section of the Act at all times, not just those in the tables within schedule 1 of the QDC MP6.1. Owners and occupiers should periodically inspect structural features to ensure the features continue to provide compliant passive fire safety outcomes for the building. The Building Code of Australia requires safety measures to be capable of performing to a standard no less than which they were originally required to achieve. 6.1 Fire doors Fire doors are an integral component of fire protection in buildings and are known as passive fire protection systems. They are installed in walls constructed as fire barriers and each fire door has a fire rating known as a fire resistance level (FRL) as does the fire wall itself. The term fire door is the common short form used for a fire-resistant-doorset. A fire resistant doorset consists of a door leaf, doorframe and associated hardware such as Commissioning and maintenance fire safety installation guideline
14 closers, handles, locks, vision panels and air grills. Fire doors are also required to be self closing and latching. Fire doors contain the spread of fire and assist in providing occupants the time to safely evacuate a burning building. Most fire doors are kept closed at all times, however some doors are held open with magnetic devices and will shut automatically upon the activation of the alarm in the event of fire. The movement (opening and closing) of a fire door should never be impaired by a door wedge/chock or other obstacle. If your building is a class 2 (e.g. apartment building), it is most likely apartment doors are fire doors which require yearly testing. Generally, the obligation to test fire safety installations is placed on occupiers and, in the first instance, the requirements to maintain these doors is placed upon the unit occupier because the unit occupier controls full access to the door. However, in practice, the body corporate is responsible for maintaining the common property and unit doors typically intersect with the common property pathways. Therefore, unit occupiers may accept the common practice of allowing the body corporate to undertake the testing on their behalf. It is recommended that owners, occupiers and the relevant body corporate put in place standing arrangements to facilitate how each apartment door can be accessed for testing as required. Where occupiers do not allow the body corporate to test and maintain the unit fire doors, the occupier must ensure their door is tested and maintained in compliance with the QDC. 6.2 Common defects of fire doors Fire doors are often installed in areas where they may be subject to regular traffic (movement of people and/or equipment) resulting in damage, defects, or wear and tear that may affect the door s efficiency during a fire. Further, aggressive environmental conditions such as constant heat or humidity, chemicals and salt air can also affect the operation of and/or the individual components that make up a fire door. Work is sometimes undertaken in buildings such as refurbishing, where the fire doors are not touched, but the installation of new floor covering might affect the required performance of a door. For example, the gaps around a fire door must not exceed certain distances. Replacing existing floor tiles with new thinner tiles could increase the gap between the door and the floor, allowing for fire to spread from one side of the door to the other. Some of the more common defects observed during routine maintenance procedures are outlined below. Door hardware is inoperative. Fire doors have a number of moving parts that are integral to its operation. All the hardware components associated with a fire door are key elements that combine to achieve the Commissioning and maintenance fire safety installation guideline
15 overall FRL that a door complies with and is certified to. These components are tested and approved by a registered testing authority and installed or repaired by an appropriately qualified person. For example, oil leaking from a door closer may affect the performance of the closer and stop the door from shutting to a fully closed position. Door leaves are warped, twisted, delaminated or buckled, creating a situation where they no longer close against the frame within acceptable gap limits. The edging of the door should also be in good condition where it is free from splitting or other damage on all sides. These defects can occur from aggressive environments such as heat, humidity, chemicals and exposure to weather. Door frames not being adequately anchored to the wall, free from distortion or with obstructions that could prevent the door from closing properly. With metal door frames exposed to aggressive elements including salt air in coastal regions they may become corroded and require regular additional maintenance to maintain compliance. Vision panels (windows) are damaged or cracked or framing is not secure. Typically, vision panels need to be made from materials of a type approved for use and securely held in place. Commissioning and maintenance fire safety installation guideline
16 7. Asbestos in fire doors Some buildings constructed before January 1990 may have fire doors using thermal insulation that is asbestos containing material (ACM). ACM is a health hazard and the Workplace Health and Safety Act 2011 and Workplace Health and Safety Regulation 2008 detail the obligations of building owners for managing and removing ACM. If a fire door is damaged to expose friable asbestos material, the material and door will need to be removed by an asbestos removalist who has a certificate to perform the work issued by Workplace Health and Safety Queensland. For fire doors, where the asbestos is bonded or enclosed, the door must be entered onto an asbestos register for the building, have a suitable label to ensure maintenance workers are aware asbestos is present, and be managed through an asbestos management plan controlling maintenance work and other activities that could lead to the ACM being disturbed. For further information about asbestos management please contact Workplace Health and Safety Queensland on or Commissioning and maintenance fire safety installation guideline
17 8. Battery operated fire alarms From 1 July 2007, the Fire and Rescue Service Act 1990 (FRSA) requires all domestic dwellings in Queensland contain at least one battery-operated 9 volt smoke alarm where there are no hard-wired 240 volt alarms installed. A domestic dwelling is defined in the FRSA as a class 1a building (e.g. attached or detached house) and the soleoccupancy unit of a class 2 building. A smoke alarm is required to be installed on or near the ceiling in all storeys of a dwelling and between bedrooms (e.g. in the hallway). There is not a requirement for battery operated alarms to be listed on occupier s statements, but the alarms are still to be maintained in accordance with the FRSA. The obligations of the lessor include: clean and test the smoke alarm/s within 30 days of the commencement of a tenancy replace the battery before it reaches the end of its manufacturer s shelf life, or where it is known that the battery is almost flat, within 30 days before the start of a tenancy replace the smoke alarm unit before it reaches the end of its service life or immediately on the expiration as specified by the manufacturer s instructions. This would typically be indicated by the warranty. The obligations of the tenant include: clean and test the smoke alarm/s during the tenancy at least once every 12 months replace batteries when they become flat during the tenancy in accordance with the manufacturer s instructions advise the lessor or real estate agent if they become aware that the smoke alarm has failed or is about to fail other than because of a battery being flat. For further information on these requirements please contact QFRS on or visit Commissioning and maintenance fire safety installation guideline
18 9. Changing standards A full cycle of maintenance must be carried out before changing maintenance standards. For example, a building s stairwell pressurisation system may not be capable of achieving the pressure test requirements of the latest standard and the test may damage the building. In this instance, the licensed contractor might recommend to the building occupier that an earlier relevant standard or the standard which was in place at the time of construction be used, because the earlier standard has a lower pressure requirement that the building system can achieve. Commissioning and maintenance fire safety installation guideline
19 10. The occupier s statement MP 6.1 requires the building occupier to provide a copy of the yearly occupier s statement to the commissioner of the QFRS, confirming that the building s fire safety installations have been maintained in compliance with the QDC. Where there is no occupier, the building owner is required to sign the statement and send a copy of to the QFRS commissioner. Optionally, an authorised person on behalf of the occupier/owner can sign the statement, for example, a person nominated on behalf of a body corporate or corporation. The occupier s statement may be submitted by post, in person or via to your local QFRS community safety office when the annual maintenance program for all of the fire safety installations has been completed. Postal addresses and fax numbers for regional offices can be found at The occupier statement can also be ed to [email protected] The occupier s statement form is included in schedule 2 of the QDC. An appropriately qualified person will provide a building occupier with a record of maintenance upon completion of each test or inspection. These records will assist a building occupier in the completion of the occupier s statement. The record of maintenance must state each of the following: (a) a description of the prescribed fire safety installation on which the maintenance was carried out (b) if the maintenance was carried out by an appropriately qualified person the name and license number of the person who carried out the maintenance (c) if the maintenance was not carried out personally by an appropriately qualified person the name and license number of the appropriately qualified person under whose personal supervision the maintenance was carried out (d) the date the maintenance was carried out (the maintenance date) (e) a brief description of the maintenance carried out (f) that the maintenance was carried out in compliance with QDC, part MP6.1 (g) the results of the maintenance of the installation, including: whether or not the person carrying out the maintenance considered the installation was in proper working order the details of any repair or other corrective action the person considered was required for the installation the details, including the date, of any repairs made to the installation or any other corrective action taken. (h) also, the record of maintenance must include: a statement, signed by the person who carried out the maintenance, certifying that the matters stated in the record of maintenance under subsection (2) are correct if the occupier has been given a critical defect notice relating to a prescribed fire safety installation mentioned in the record of maintenance the notice. Commissioning and maintenance fire safety installation guideline
20 11. Buildings with several tenancies There may be instances where there are many occupiers in one building, such as a shopping complex that consists of a large number of tenancies. Occupiers are responsible for fire safety installations within their own tenancy and this will include installations located outside the building if the tenant leases the entire premises. The building s body corporate or owner has responsibility for the maintenance of all other installations for the common areas, including prescribed fire safety installations that are located on the premises, but outside the building. It is recommended that for integrated fire safety installations that service the entire building through different tenancies, such as sprinkler or fire alarm and detection systems, that one entity take practical responsibility for the maintenance of that installation. For example the building s owner or body corporate could oversee the maintenance of hydrants, sprinklers, hose reels and alarm and warning systems. Installations located within individual tenancies, such as fire extinguishers, generally fall under the responsibility of the tenant occupying the tenancy although, it is recommended that the body corporate or building owner be permitted to undertake maintenance of all installations if this service is offered. If tenants refuse to allow the owner or body corporate to maintain parts of the integrated systems located within their tenancy, then the tenant will also need to ensure the installations are maintained. It is recommended that tenants allow the owner or body corporate to inspect and test prescribed fire safety installations that are integrated throughout the building, because these systems often require periodic testing and replacement of various elements and this should be done with the whole system in mind. Also, building-wide systems should be tested in their entirety and not for how they operate in individual tenancies. Where a building has multiple tenancies, it is not necessary for every tenant (being the occupier) to submit a separate occupier s statement to QFRS. If the body corporate undertakes maintenance of all of the building s prescribed fire safety installations, a compliant occupier s statement by the owner or body corporate will be accepted as satisfying each tenant s obligations regarding the occupier s statement. However, where the body corporate or owner does not fulfil this role, or where a compliant occupier s statement has not been prepared by the owner or body corporate, each individual tenant remains responsible for their obligations to comply with the code. It is recommended that owners specify their arrangements through their body corporate. In addition, it is recommended that tenants and owners specify the occupier s statement arrangements in their lease agreements. Commissioning and maintenance fire safety installation guideline
21 Example 4 A shopping centre contains 87 individual tenancies. Due to the size of the building, facilities are centrally managed. In this instance, the owner s facilities management team coordinates the maintenance of all prescribed fire safety installations within the common area and within individual tenancies. Once the yearly maintenance regime is completed, the facilities manager, who is the authorised person to sign on behalf of the owner or company, signs one occupier s statement for the entire building (including the tenancies) and submits this statement to QFRS. As the statement specifies and includes all of the fire safety installations in the building it is accepted as satisfying the QDC s reporting requirements. Example 5 A restaurant is located in a block of shops and the shopping complex is managed by a body corporate. The restaurant has fire extinguishers in the kitchen within the tenancy, but the hydrant for the restaurant is in the common area and is used to protect all of the shops in the building. In this instance, the restaurant tenant (being the occupier) may either ensure periodic maintenance is carried out on extinguishers or allow the body corporate to maintain the extinguishers. The body corporate is responsible for maintaining the hydrant and it may also maintain the extinguishers on behalf of the tenant. If the restaurant and other tenants maintain their extinguishers, several occupier s statements would be submitted by the tenants to QFRS and one statement would be submitted for the hydrant by the body corporate. Alternatively, if the body corporate maintained all of the installations then one occupier s statement is accepted as satisfying the QDC s reporting requirements. Commissioning and maintenance fire safety installation guideline
22 12. Keeping records safe Records of commissioning or maintenance must be kept with your building s fire evacuation plan in the building in a way that it is reasonably likely not to be damaged in the event of a fire or hazardous materials emergency. For example, the records could be contained in a metal filing cabinet. A copy of records should be kept in another place and usually the building s licensed fire contractor will keep copies of work done. Occupiers may also keep the secondary copy as an electronic copy of the records in accordance with section 32E of the Acts Interpretation Act 1954, for example, on a computer hard drive, memory stick or compact disc. The electronic copy should be kept in another place (i.e. not the premises). The records must be kept for a minimum of two years and must be made available upon request from an authorised QFRS officer. An appropriately qualified person who carries out commissioning or maintenance of a water-based fire safety installation must keep a record of the document mentioned in P4 for a reasonable time. QFRS officers have powers to audit buildings for fire safety. This includes powers of entry to a building and to demand the occupier to produce records of maintenance. QFRS officers are also authorised to issue notices or on the spot fines to occupiers who do not comply with requests for producing records of the maintenance requirements of the QDC. Commissioning and maintenance fire safety installation guideline
23 13. Critical defect notices When the maintenance provisions for fire safety installations were transferred from the BFSR to the QDC, there were no changes to the requirements for critical defect notices. If an appropriately qualified person has issued a critical defect notice to a building occupier, it means that the person has detected a defective fire safety installation where the defect: is likely to render the installation inoperable is reasonably likely to have a significant adverse impact on the safety of occupants of part or all of the building if a fire or hazardous materials emergency happens. Some examples of critical defects would include: a defect making a fire detection and alarm system inoperable, therefore, building occupiers are not warned of a fire a defect in a pump where the building s fire hydrant system can no longer provide water to put out a fire. It is important to rectify this defect as soon as it is practically possible. Interim measures may need to be put in place for a critical defect until repairs can be effected. Example 6 An inspection of a monitored alarm system for a high-rise hotel building has revealed the alarms will not activate during an emergency. Interim safety steps must be put in place because the system failure in the building has placed the occupants at risk and the critical defect notice relates to a serious life safety matter. The building occupier contacts the QFRS of the problem and employs a person to undertake fire-watch duties to continually monitor each floor, manually warn occupants, manage the building s evacuation and to contact QFRS by telephone in the event of an emergency. Example 7 A fire hydrant system for an industrial warehouse has ruptured. The licensed contractor has found that the system cannot achieve the required water pressure and has issued a critical defect notice. In this situation, if a fire occurs there will be insufficient water supplies to fight and contain a fire. The building occupier contacts QFRS to notify them of the defect and arranges for a suitable water supply and fire management plan to be in place until the defect is rectified. Where a critical defect notice has been issued by a contractor and the critical defect has been rectified, the occupier should attach both these records of maintenance to the occupier s statement before sending it to the QFRS. Commissioning and maintenance fire safety installation guideline
24 14. Body corporate obligations The maintenance code applies to a range of buildings which commonly have a body corporate such as class 2 (residential apartments), class 3 buildings (such as holiday/business accommodation) and commercial/industrial buildings. Members of a body corporate will need to determine who is authorised to sign the yearly occupier s statement on behalf of the body corporate. Suggested actions that a body corporate could take to ensure the building is maintained include: determining who is authorised to sign the occupier s statement on behalf of the body corporate confirming the date of when the building was approved for construction entering into a maintenance contract with an appropriately licensed person to ensure ongoing periodic maintenance is carried out confirming dates of maintenance inspections where entry into individual units may be required, such as for the inspection of unit entry doors that are fire doors keeping records of all maintenance for two years with the building s fire and evacuation plan include fire safety maintenance in your funding forecasts. Commissioning and maintenance fire safety installation guideline
25 15. Fire blankets AS provides for inspection and maintenance of fire blankets, however, fire blankets are not listed as a prescribed fire safety installation under the Building Act 1975 or the Fire and Rescue Services Act 1990 and therefore are not addressed in the QDC unless they form part of an alternative solution. For example, an alternative solution for a laboratory includes fire blankets to be installed within each testing station. The alternative solution states that the blankets must be maintained against AS In this instance, the fire blankets have become prescribed fire safety installations because they are required as part of an alternative solution to meet the performance criteria of the BCA. Please refer to the Alternative solution section of this document to determine if your building has been approved with an alternative solution. Commissioning and maintenance fire safety installation guideline
26 16. Legislation The following legislation is applicable: Acts Interpretation Act 1954 Section 14A states that in interpreting a provision of an Act (including statutory instruments made under an Act), the interpretation that will best achieve the purpose of the Act is to be preferred to any other interpretation. Building Act 1975 Section 258 provides for guidelines to be made to assist with compliance with the Building Act Building Fire Safety Regulation 2008 Sections 49 to 55B provides for the maintenance of prescribed fire safety installations. Fire and Rescue Service Act 1990 Part 9a refers to building fire safety. Plumbing and Drainage Act 2002 Workplace Health and Safety Regulation 2011 Part 13 refers to asbestos management and removal. Queensland Building Services Authority Act 1991 Complete copies of Queensland legislation referred to in this guideline can be downloaded for free at A copy of the QDC can also be downloaded for free at Commissioning and maintenance fire safety installation guideline
27
ADVISORY NOTES for FIRE SAFETY MANAGEMENT TOOL FOR OWNER/OCCUPIERS
QUEENSLAND FIRE AND RESCUE SERVICE ADVISORY NOTES for FIRE SAFETY MANAGEMENT TOOL FOR OWNER/OCCUPIERS Instructions For Use If you are the owner of, or a business or person that is occupying, a building
FIRE SAFETY INFORMATION FACT SHEET
Disclaimers: This information was believed to be correct at the date of its publication. This information is for general information purposes only and should not be relied upon for legal advice. FIRE SAFETY
Inspect and Test FPAS Units of Competencies descriptions
Inspect and Test FPAS Units of Competencies descriptions FPAS incorporates the following units of competency across ten (10) categories of inspect and test activities. CPPCMN2002A Participate in workplace
Compliance Schedules and Building Warrant of Fitness
Compliance Schedules and Building Warrant of Fitness Purpose of this guidance information The purpose of this guidance information is to help building owners and managers of commercial, industrial or communal
How To Get A Fire Safety Licence In Australia
Fire occupational licences April 2015 Introduction The Queensland Building and Construction Commission (QBCC) is a statutory body established under the Queensland Building and Construction Commission Act
UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS
Fire Safety Technical Guide UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS 1.0. BACKGROUND 1.1. The Regulatory Reform (Fire Safety) Order (known Fire Safety Order) applies to England and Wales (Northern
How To Write A Fire Risk Assessment
Fire Safety Risk Assessment This form is to aid you in carrying out a fire safety risk assessment of a property. The form is separated in to two parts: Part 1 initial assessment form and guidance notes
Smoke Alarm Legislation Frequently Asked Questions
THE REQUIREMENT FOR SMOKE ALARMS Is it law for residential properties to have mains powered smoke alarms installed? Residential properties that are subject to sale, transfer of ownership, rent or hire
Decree of the Ministry of the Environment. on fire safety of garages
E4 THE NATIONAL BUILDING CODE OF FINLAND Fire safety of garages Guidelines 2005 Decree of the Ministry of the Environment on fire safety of garages Adopted in Helsinki, 22 March 2005 Pursuant to the Decision
What you need to know about. Smoke alarms for residential buildings
What you need to know about Smoke alarms for residential buildings Are s compulsory? Smoke alarms are compulsory and must be installed in residential buildings on or near the ceiling of every storey. What
Fire Safety Requirements for Child Care Centre
Fire Safety Requirements for Child Care Centre A. Restrictions on Location Child care centre shall not be located : - (a) (b) in any premises designed for residential use; in any industrial building, warehouses,
Repairs & maintenance
Tenancy Facts Information for tenants and residents in Queensland Repairs & maintenance When you rent a place to live, the lessor, agent or provider must ensure the place is fit for you to live in and
Fire precautions in dwellings. Private sector housing Providing homes building communities
Fire precautions in dwellings Private sector housing Providing homes building communities Version 3 Published by Norwich City Council August 2011 Contents Page Introduction 1 2 Types of dwellings (A) Shared
For use by landlords of small premises Premises Address
fire risk assessment For use by landlords of small premises Premises Address FIRE RISK ASSESSMENT for use by landlords of small premises Person having control of the premises: Name of landlord (if different):
Greater Manchester Fire and Rescue Service
Greater Manchester Fire and Rescue Service Record of Fire Safety Equipment Testing CONTENTS 1. MEANS OF ESCAPE 2. FIRE WARNING AND AUTOMATIC FIRE DETECTION 3. FIRE EXTINGUISHERS AND HOSEREELS 4. EMERGENCY
The terms hazard and risk are often used, which we define as the following:
Fire Safety Last updated in October 2010 This information sheet aims to give safety reps a basic understanding of fire safety and fire risk assessments under the current law. More detailed information
UPP Residential Services Fire Risk Assessment
UPP Residential Services Fire Risk Assessment TS11151-R02-DRAFT1 15 August 2011 for: Keynes College University Road Canterbury Kent Recommended latest review date 14 August 2011 Executive summary This
Asbestos Management Policy
Asbestos Management Policy Originator: Approval date: Policy and Strategy Team Sovini Board PCHA Board OVH Board/EMT 3 rd December 2012 22 nd November 2012 25 th September 2012 Review date: December 2013
Asbestos Policy. Ymddiriedolaeth GIG Gwasanaethau Ambiwlans Cymru Welsh Ambulance Service (NHS) Trust. November 2007. All Staff.
Appendix 1 Ymddiriedolaeth GIG Gwasanaethau Ambiwlans Cymru Welsh Ambulance Service (NHS) Trust Asbestos Policy Approved by Date Review Date Target Audience Trust Board November 2007 November 2008 All
The Types of Standard 2 Guidance on the Standards 2 Changes to Legislation 2
CONTENTS INTRODUCTION 2 The Types of Standard 2 Guidance on the Standards 2 Changes to Legislation 2 SCOTTISH CORE STANDARDS FOR ACCREDITED LANDLORDS 3 1 Communication with the Tenant 3 2 Equality Issues,
Compliance Document for New Zealand Building Code Clause F7 Warning Systems Fourth Edition
Compliance Document for New Zealand Building Code Clause F7 Warning Systems Fourth Edition Prepared by the Department of Building and Housing This Compliance Document is prepared by the Department of Building
LPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market
LPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market Ian Stewart Passive installer scheme manager September 2011 Introduction to BRE Global Research,
ASBESTOS CONTAINING MATERIALS POLICY
ASBESTOS CONTAINING MATERIALS POLICY Document Control Version 3 Ratified by Risk Management Sub Group Date Ratified 19 December 2012 Name of Originator/Author Head of Estates and Facilities Name of Responsible
Restaurant & café guide
'Helping our customers stay in business by reducing risk' NZI Risk Solutions TM About NZI Risk Solutions NZI has extensive experience in providing expert risk management advice to help our commercial customers
Fire Safety Risk Assessment Checklist for Residential Care Premises
Checklist for Residential Care Premises Name of Premises: Address of Premises: Name of Responsible Person: What area / location does the assessment cover? Does the assessment cover the whole site YES or
FIRE PREVENTION & INVESTIGATION DIVISION 125 Idylwyld Drive South Saskatoon, SK S7M 1L4 Phone: (306) 975-2578 Fax: (306) 975-2589.
FIRE PREVENTION & INVESTIGATION DIVISION 125 Idylwyld Drive South Saskatoon, SK S7M 1L4 Phone: (306) 975-2578 Fax: (306) 975-2589 Bulletin 16-12 Fire Drills This guideline was developed to assist persons
Lee Baron FIRE RISK ASSESSMENT
FIRE RISK ASSESSMENT, 13/21 Cantelupe Road, East Grinstead Prepared for: Lee Baron 7 Swallow Place Oxford Circus London W1B 2AG Prepared by: Violet McIntyre CMIOSH William Martin Compliance Solutions Limited
The Smoke and Carbon Monoxide Alarm (England) Regulations 2015
The Smoke and Carbon Monoxide Alarm (England) Regulations 2015 Q&A Booklet for the Private Rented Sector landlords and tenants September 2015 Department for Communities and Local Government Crown copyright,
INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT
CITY OF SPRING LAKE PARK Code Enforcement Department 1301 81 st Avenue NE Spring Lake Park MN 55432 Business Phone 763-784-6491 Fax 763-792-7257 INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS
Loss Prevention Standard
Loss Prevention Standard : ISSUE 3.0 Requirements for the LPCB Approval and Listing of Companies Undertaking the Maintenance and Repair of Doorsets, Shutters, and Active Smoke/Fire Barriers This standard
FIRE SAFETY REQUIREMENTS
FIRE SAFETY REQUIREMENTS 156.200 GENERALLY. A. Scope. The provisions of this chapter shall govern the minimum conditions and standards for fire safety relating to structures and exterior premises, including
Guidance Sheet : Legislative Requirements for Rented Properties
Guidance Sheet : Legislative Requirements for Rented Properties Introduction: Letting your property and becoming a landlord may seem like the simple solution to filling an empty property and it can be
Smoke Alarm Legislation
Is it law for residential properties to have mains powered smoke alarms installed? Residential properties that are subject to sale, rent or hire are required under the Building Regulations 2012 to install
A guide to landlords duties: Gas Safety (Installation and Use) Regulations 1998. What type of property is covered?
Landlords A guide to landlords duties: Gas Safety (Installation and Use) Regulations 1998 This leaflet is aimed at landlords and explains some of the main requirements of the Gas Safety (Installation and
Fire Safety Policy. Fire Safety Policy: May 2011 Page 1 of 6. Version 1. Scope:
Version 1 Fire Safety Policy Scope: Effective Date: Review Date: Signed Off by: Author: Policy Owned by: This policy applies to Hackney Homes Ltd working on behalf of the London Borough of Hackney July
Asbestos at work guide
Asbestos at work guide Contents Introduction.... 2 Frequently asked questions.... 4 The Control of Asbestos Regulations 2006... 5 Types of asbestos survey.... 7 1 Introduction This document provides a
Flammable and combustible liquids. Licence guide. Guide for operators
Guide for operators About this guide This guide is for businesses that provide flammable and combustible liquids. It provides advice on licensing and fit-out guidelines for businesses. Table of Contents
Overview of Hotel Fire Safety Requirements
Overview of Hotel Fire Safety Requirements in the Fire Code Susan Clarke, P.Eng. Office of the Fire Marshal - January 10, 2012 1 Agenda Regulation History - Hotels Fire Code Overview (Parts 1 to 8) Defined
Asbestos Policy ASBESTOS POLICY. Version 2 / Jun 2015 Page 1 of 11 Asbestos Policy
ASBESTOS POLICY Version 2 / Jun 2015 Page 1 of 11 Asbestos Policy This is a controlled document. It should not be altered in any way without the express permission of the author or their representative.
IFE Level 4 Certificate in Fire Science and Fire Safety (HL)
IFE Level 4 Certificate in Fire Science and Fire Safety (HL) Unit 2: Fire Safety Unit Reference Number: D/505/5932 Introduction This unit focuses on the prevention and detection of fire in premises and
How To Handle An Emergency At A Strata Corporation
24 HOUR ANSWERING SERVICE The regular office hours at our firm are 9:00 am to 5:00 pm Monday to Friday. After these regular hours, the same telephone number is answered by a Telephone Answering Service,
Underwriting Guidelines for Condominium Pac and Condominium Pac Plus
UNDERWRITING GUIDELINES FOR CONDOMINIUMS SEGMENT Local exceptions to these underwriting guidelines may apply. Please consult with your underwriter or sales executive for details and to discuss risks which
Australian/New Zealand Standard
Australian/New Zealand Standard The use of ventilation and air conditioning in buildings - Part 1: Fire and smoke control in buildings UPDATED AS/NZS 1668.1:2015 What is the scope of this Standard? The
Restaurant and Café Risk Management Guide. Don t Risk It!
property & liability Restaurant and Café Risk Management Guide Don t Risk It! About Lumley Insurance Lumley Insurance has extensive experience in restaurant insurance and risk management. This experience
Service Level Agreement/Specification
Service Level Agreement/Specification For Maintenance and Associated Risk Management Services at New College Campus and Associated properties May 2007 INDEX 1. SCOPE 2. MAINTENANCE SERVICE LEVELS a. Staffing
SPECIFICATIONS FOR APPROVED OFFSITE RECORDS STORAGE FACILITIES
1. Bonding and Insurance 2. Facilities (including equipment and materiel e.g., shelving, pallets, containers and other internal fixtures and contents) The storage facility company must be bonded and insured.
Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Proposed amended Acceptable Solution for Warning Systems
Proposed changes to the Acceptable Solution for Building Code clause F7 (Warning Systems) Appendix A Proposed amended Acceptable Solution for Warning Systems s in the grey boxes form part of the proposed
H2 Opening Statement Asbestos
H2 Opening Statement Asbestos Every year there are thousands of asbestos related deaths. Asbestos fibres accumulate in the lungs, therefore several diseases can occur, among these are two main types of
FIRE RISK ASSESSMENT
REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT This template has been provided to assist the Responsible Person with the preparation of a Fire Risk Assessment and is not intended for commercial
General Fire Code Requirements Within Commercial Tenant Spaces
FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding
Technical qualifications for licensing
Building Industry and Policy Technical qualifications for licensing Queensland Building and Construction Commission licence requirements April 2016 Technical qualifications Queensland Building and Construction
We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.
September 14, 2012 Dear AMM Member: Please see the attached Fire Code Frequently Asked Questions. This document was compiled by the Office of the Fire Commissioner at the AMM s request to help clarify
ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600
OSHA REGULATION: 9 CFR 90.5 WELDING, CUTTING, AND BRAZING ( HOT WORK ) A. POLICY. This procedure follows requirements set forth in 9 CFR 90.5.. This policy applies to all Hot Work operations being done
Owner Builder permit. Owner builder application. Company application. Lease agreements. Owner builder course. Build better.
Build better. Owner Builder permit Under the Queensland Building and Construction Commission Act 1991 you must obtain an Owner Builder permit before carrying out building work with a value of $11,000 or
FIRE DETECTION AND ALARM SYSTEMS
HMO Information Sheet No 1 FIRE DETECTION AND ALARM SYSTEMS 1. Introduction When a property is in multiple occupation, the risk of fire breaking out is greater than in an ordinary single family home. Some
Important Ontario Fire Code Information for Building Owners in the City of Windsor
Important Ontario Fire Code Information for Building Owners in the City of Windsor This information is intended to be used a reference only. For a complete listing consult the Ontario Fire Code or contact
Customer Installation Safety Plan. March 2015
Customer Installation Safety Plan March 2015 Document History Issue No. Date Approved By Summary of Changes 1 June 2014 Chief Engineer Updated and revised in line with requirement for biennial review under
Service Level Agreement (SLA)
Hertford College, Oxford Service Level Agreement (SLA) For Maintenance, Risk Management, and Domestic Accommodation Services At Hertford College, its residential annexes and non- residential properties
The Electrical Safety Regulation (pre and post 1 January 2014)
The Electrical Safety Regulation (pre and post 1 January 2014) The following table provides an overview comparison between the Electrical Safety Regulation 2002 (the ESR 2002) current as at 1 July 2013
ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK. Website www.iomfire.com
ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK Website www.iomfire.com ADDRESS OF PREMISES FIRE CERTIFICATE No. (where applicable).. LOCATION OF LOG BOOK. CONTENTS OF LOG BOOK Useful telephone
BUILDING COMPLIANCE MANAGEMENT
The first IQP company in New Zealand to be accredited for BWOF management nationwide ISIS BUILDING INSPECTIONS LTD BUILDING COMPLIANCE MANAGEMENT A Guide to BWOF Compliance for Building Facilities Managers
c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.
Walmart Standards for Suppliers Section 7. Health and Safety 7. Health and Safety Suppliers must provide workers with a safe and healthy work environment. Suppliers must take proactive measures to prevent
NFoPP Technical Award in Residential Inventory Management and Practice. Example Examination Questions
NFoPP Technical Award in Residential Inventory Management and Practice Example Examination Questions The following questions are designed and made available so as to show candidates the type and level
Notifiable work. A guide for plumbers and drainers. October 2012. Building Codes Queensland Department of Housing and Public Works
Notifiable work A guide for plumbers and drainers October 2012 Building Codes Queensland Department of Housing and Public Works Notifiable work a guide for plumbers and drainers Page 2 of 22 Table of contents
RESIDENTS FIRE SAFETY INFORMATION PACK
RESIDENTS FIRE SAFETY INFORMATION PACK MARIE CURIE SCEAUX GARDENS ESTATE LONDON SE5 THE CONTENTS OF YOUR PACK Section Page No. 1. 3. Introduction Here we will explain the purpose of the Fire Safety Information
RESIDENTS FIRE SAFETY INFORMATION PACK
RESIDENTS FIRE SAFETY INFORMATION PACK CASTLEMEAD CAMBERWELL ROAD LONDON SE5 THE CONTENTS OF YOUR PACK Section Page No. 1. 3. Introduction Here we will explain the purpose of the Fire Safety Information
CIS Asset Identification and Labelling Standard
CIS Asset Identification and Labelling Standard The University of Sydney Engineering & Sustainability Team Document Control Document Name: CIS Asset Identification and Labelling Standard Document ID: CIS-PLA-STD-Asset
The Role of Fire Doors. BWF-Certifire Fire Door and Doorset Scheme
The Role of Fire Doors BWF-Certifire Fire Door and Doorset Scheme Fire doors today s agenda 1. Fire doors are essential in passive fire protection A requirement in compartmenting a building Protecting
Liberty Mutual Insurance RISK ENGINEERING PROCEDURE. REP 07 Incident Planning For external use
Liberty Mutual Insurance RISK ENGINEERING PROCEDURE REP 07 Incident Planning For external use Risk Engineering Procedure Incident Planning CONTENTS Page PURPOSE... 3 BACKGROUND... 4 INCIDENT PLANNING PREPARATION...
General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission
General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission Local Fire Alarm 064. FIRE ALARM SYSTEMS 01. Scope 02. Definitions 03.
OWNER BUILDER AS AN WHAT ARE MY RESPONSIBILITIES UNDER THE DEVELOPMENT ACT 1993
AS AN OWNER BUILDER building work? What records should I keep? Is insurance required? W I need approval for? What do I need approval for? How do I obtain building work? How do I obtain approval? What records
London Borough of Barnet. Fire Safety in Houses in Multiple Occupation. A Guide to Landlords
London Borough of Barnet Fire Safety in Houses in Multiple Occupation A Guide to Landlords March 2016 Contents Introduction p.3 Summary of main requirements p.3 Fire Safety Precautions p.4 Protecting the
FIRE SAFETY REGISTER. Premises Name: Premises Address: Fire Safety Manager: Contact No. Kerry County Fire Service www.kerrycoco.ie
FIRE SAFETY REGISTER Premises Name: Premises Address: Fire Safety Manager: Contact No. Kerry County Fire Service www.kerrycoco.ie 1 CONTENTS Section Title Page 1.0 Introduction 3 2.0 Guidance for the completion
Practice Note 2006-27
Practice Note Self-Contained smoke alarms to existing buildings This updates the previous Practice Note 2005-27 issued May 2005. Reference to the BCA in this Practice Note means Volume One and Volume Two
RHP SERVICES: INFORMATION FOR LANDLORDS AND PROPERTY OWNERS
RHP SERVICES: INFORMATION FOR LANDLORDS AND PROPERTY OWNERS Types of Property We are looking for licensed houses in multiple occupation (HMOs), studio, one, two, three four and five bedroom homes. RHP
SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective
SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective The National Fire Alarm Code, NFPA 72, sets the minimum requirements of performance, selection, use and location of automatic detection
1. Fire Safety Policy and Responsibilities. Consult the Employer s Fire Safety Policy and establish responsibilities of staff for fire safety.
Management Checklist 1. Fire Safety Policy and Responsibilities. Consult the Employer s Fire Safety Policy and establish responsibilities of staff for fire safety. 2. Fire Hazard and Risk Assessment. Use
ASBESTOS MANAGEMENT PROGRAM
ASBESTOS MANAGEMENT PROGRAM Prepared By: Triumvirate Environmental Program Approval Developed: August 2011 Updated: June 2015 Associate Vice President of Public Safety & Administrative Services Date Associate
ASBESTOS MANAGEMENT POLICY
ASBESTOS MANAGEMENT POLICY Published : 4th Revision December 2014 1 Table of Contents INTRODUCTION... 3 DUTY TO MANAGE ASBESTOS... 3 DUTIES OF CAMPUS SERVICES... 3 1.0 POLICY OBJECTIVES... 5 2.0 RESPONSIBILITIES...
PRO PRO. ProSurance TM. Application Form INSURANCE FOR PROFESSIONALS
PRO INSURANCE FOR PROFESSIONALS ProSurance TM PRO Application Form This is an application for an errors and omissions package policy aimed at a wide range of small and medium-sized professionals. As well
FREQUENTLY ASKED QUESTIONS TESTING AND TAGGING OF ELECTRICAL EQUIPMENT
FREQUENTLY ASKED QUESTIONS TESTING AND TAGGING OF ELECTRICAL EQUIPMENT HAS THE LAW CHANGED REGARDING TESTING AND TAGGING OF ELECTRICAL EQUIPMENT? Yes, Simplified safety regulations for electrical equipment
COMMON MYTHS ABOUT FIRE SPRINKLER PROTECTION
"Water damage from a sprinkler system will be more extensive than fire damage." Water damage from a sprinkler system will be much less severe than the damage caused by water from firefighting hose-lines
Fire Safety Challenges and Solutions. Claire Guise Health and Safety Manager
Fire Safety Challenges and Solutions Claire Guise Health and Safety Manager Marie Curie Cancer Care (UK Wide) 9 Palliative Care Hospices (owned) Facilities Manager in place (NEBOSH General Certificate
Grasshoppers Rugby Football Sports and Social Club. The Fire Risk Assessment
Grasshoppers Rugby Football Sports and Social Club The Fire Risk Assessment Revision 1 Dated: 15th February 2013 CONTENTS 1. PREMISES DETAILS 2. PREMISES PLAN 3. HAZARDS 4. HISTORY 5. MITIGATING THE EFFECTS
FIRE SAFETY RISK ASSESSMENT
FIRE SAFETY RISK ASSESSMENT For small single occupancy premises Premises Hertco Ltd ACME House, Old London Road, Hertford SG17 7LD Fire Safety Risk Assessment for Small Premises Introduction Regulatory
Health and Safety Policy
Health and Safety Policy October 2014 1 October 2014 Contents: Introduction 1. STATEMENT OF INTENT AND POLICY OBJECTIVES 2. RESPONSIBILITIES AND ACCOUNTABILITIES FOR HEALTH AND SAFETY 2.1 The Director
Landlord/Agent Code of Conduct
Landlord/Agent Code of Conduct Commitment to this is a requirement of the Home Stamp accreditation scheme The Home Stamp Code of Conduct aims to provide guidance and advice regarding the management of
BUILDING OR RENOVATING
A GUIDE TO BUILDING OR RENOVATING YOUR IDEAL HOME building work? What records should I keep? Is insurance required? W I need approval for? What do I need approval for? How do I obtain building work? How
FLOODS FACT SHEET ADVICE FOR RESIDENTS Approvals for repairing, renovating or rebuilding flood-affected houses
2 February 2011 Updated 16 March 2011 FLOODS FACT SHEET ADVICE FOR RESIDENTS Approvals for repairing, renovating or rebuilding flood-affected houses This fact sheet provides advice for residents about
Name Of Occupancy Date. Yes No Describe
FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address
AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839
AVAILABLE TO DOWNLOAD ON THE APOLLO APP a guide to Fire Alarm Systems Design BS5839 Part1:2013 The Regulatory Reform (Fire Safety) Order (FSO) became law on 1 October 2006 Legally you must comply! What
Office of the State Fire Marshal. Fire Rated Doors
Office of the State Fire Marshal Fire Rated Doors Fire Rated Doors These doors serve a purpose. They are manufactured in a way that is to help reduce the spread of fire and smoke. Fire rated doors allow
For use by landlords of small premises Premises Address
fire risk assessment For use by landlords of small premises Premises Address FIRE RISK ASSESSMENT for use by landlords of small premises Person having control of the premises: Name of landlord (if different):
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS
FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011, Updated March 2012 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or
