VFD Wiring Best Practices

Similar documents
AC and DC Drive System Installation Information

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

EMC Installation / Application Guidelines VECTORSTAR (VSA) Series Electronics MVS001H. EMC / CE Guidelines

Grounding Demystified

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Video Camera Installation Guide

Specifying a Variable Frequency Drive s

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Grounding and Shield Termination. Application Note 51204

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications. Application Note. June 2011

Good EMC Design Principles: cable routing

E2 Controller Wiring Practices Rev 4 19-APR-2010

PL-277x Series SuperSpeed USB 3.0 SATA Bridge Controllers PCB Layout Guide

EMC Standards: Standards of good EMC engineering

White Paper: Electrical Ground Rules

MYTHBUSTING Takes on Shielded Cabling

Chapter 9. Bonding and Grounding

RS485 & RS422 Basics

Understanding Shielded Cable

This application note is written for a reader that is familiar with Ethernet hardware design.

EMC Engineering Guidelines For Automation Systems PS 4 PS /97 AWB GB

Marine HF SSB Installation and Grounding. Anatomy of the Best Tour 2006

EMI and t Layout Fundamentals for Switched-Mode Circuits

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

100% EMI Emission Containment

ST Series POWER SUPPLIES USER INSTRUCTIONS

General Information. Installation Wiring Practices for Vickers Electronic Products

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

WHITEPAPER. Cable and Connector for Hiperface dsl motor drive applications

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

400 Series - Mini USB Buccaneer

RAY-MAX Integrated Solar Power Strip

Solar monitoring gateway quick start guide

Lightning Arresters P KVA P KVA. Description & Installation

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Siemens Energy & Automation. structured. WIRING Product Training Series: Advanced Video Session 3

Electromagnetic Compatibility Considerations for Switching Power Supplies

The Do s and Don ts of Pressure Transducers

HARAX circular connector

Current Probes. User Manual

TC Grounding and Bonding for Telecommunications Systems

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

Coaxial Cable Entry Panels, Coax and Grounding Connectors. Technical Note

What Are the Benefits of Using VFD Motors?

SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03

Electromagnetic (EMI) shielding

Printed Circuit Boards. Bypassing, Decoupling, Power, Grounding Building Printed Circuit Boards CAD Tools

MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders

Computers Are Your Future Prentice-Hall, Inc.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

White paper. Shielded or unshielded network cables A matter of choice, electromagnetic environment and compatibility

This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

Application Note AN:005. FPA Printed Circuit Board Layout Guidelines. Introduction Contents. The Importance of Board Layout

GENERAL POWER SYSTEM WIRING PRACTICES APPLIED TO TECNADYNE DC BRUSHLESS MOTORS

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

Inverter / Charger Installation General Operations and AC and DC Connections

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

Current Transformer (CT) Selection Guide

Installation, Operation and Maintenance Manual

APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.

MidNite Solar E-Panels Explained

KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES

Introduction. Benefits of Variable Frequency Drives

Understanding the Electrical Performance of Category Cables

with Component Rating A Simple Perspective

Subject: Glenair MIL-PRF Conduit Surface Transfer Impedance Test

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

LOXONE 12 Channel Amplifier

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

LocoNet, the Digitrax Difference

Troubleshooting accelerometer installations

Operation and Installation Manual

OPLC Installation Guide

1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

How to Choose the Right Cable Category

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters

Screened cable and data cable segregation

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

Industrial Ethernet The Perfect Cable for an Imperfect Environment

SECTION SIGNAL WIRE AND CABLE

Sending A/V Signals Over Twisted Pair Cables: An Introduction. What is A/V over twisted pair?... 2

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Standard Buccaneer - USB

Nexus Technology Review -- Exhibit A

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

Comm5 Wiring Installation

Understanding SMD Power Inductors. Application Note. July 2011

Transcription:

Application Note AP040076EN Introduction With a growing need for saving energy, variable frequency drives are being used in many general purpose applications where they are controlling 3-phase electric motors. With the use of the VFD not only saves energy but also saves the life of motors by providing a soft start and advanced process control for motor applications where in the past motors were started across the line. With using the VFD there are some new considerations that need to be made when installing and commissioning of the system. One of the biggest considerations that need to be made is the power, control, ground, communication, and analog control wiring techniques need to be understood fully to maintain proper operation, prolong the life of the system, and reduce the EMI (Electromagnetic Interference) that can be caused when introducing the VFD to the system. Power Wiring When looking at power wiring, there are a few things that need to be considered when applying it to a VFD. Sizing The size of the power wires and fuses that are going to the VFD should be sized to handle the overall load and voltage rating of system. The wires going out the motor need to be sized based off the current and voltage that will be carried on them. In some applications this could be at a lower level depending on the motor load or if multiple motors are used the motor wiring should be sized for the load of all the individual motors. Type When looking at the type of cable to use it comes down to the insulation level it has to the prevent EMI. Single wire conductors can be used but shielded power cable is the preferred cable. This is the case for both input and output cables but with output cables instead of the interference radiating from the conductors, a larger shield will force the current noise back to the VFD s bus. Specialty designed cables are made to handle VFD applications where four conductors are enclosed in a shielded cable, the voltage rating is typically higher in these cases due to the added insulation. Routing Routing is a major issue when looking at the input and output side of the drive. It is suggested that the input wires are kept apart from any output wires going to the motor. There is no standard spacing between power wires due to the type of cable that is selected and how it is shielded, but it is suggested that there be at least one inch between cables if they have to run in parallel. If they have to cross each other it is suggested that they cross at a 90 angles to prevent interference. Shielding For the input and output motor leads it is suggested to have the shielding terminated on both ends to the ground location, to keep a common ground throughout the system. Running wiring in conduit will also provide some protection if a shield wire is not provided, but there could potentially be some noise induced from the contact points. Note: See the VFD User Manual for more information in regards to power wiring to the drive and to the motor.

Application Note AP0400076EN Control Wiring Similar consideration need to be taken when looking at the control wiring. Sizing The sizing of the control wire is again going to be based off the current load and voltage that will be on them but it is suggested that it is rated for 600V. It is suggested to use 20 AWG shield cable when running analog signals, 14 AWG for relays, and 16AWG for any other control wires. Type When it comes to the type of cable to use, there are many options depending on the size requirements (14 AWG 600V MTW Stranded for 120Vac wire and 16 or 18 AWG 600V MTW Stranded wire for 24Vdc wire for up to 10 and 5 amps). Standard twisted pair cables will provide protection for EMI but it is suggested to use a shielded twisted pair cable. Some communication protocols have their own cabling standard that should be followed. Routing With the twisted pair cabling for control and communications they should not be routed by any high voltage (above 50Vdc) power wiring. If they have to run parallel with high voltage wiring, they should be spaced apart as much as possible, 2 minimum (2 ½ -3 is preferred on 120Vac and less, 4 for 480Vac). A grounded barrier is preferred if possible between cables in parallel. If crossing over any high voltage cables it is suggested that it crosses at a 90 angle to prevent noise transmitting onto the signal wires. Shielding When having a shielded cable, it is suggest to ground the shield on one end of the cable, it most system at the drive is preferred. There are ground straps that can be used to clamp around the cable shield to terminate. Do not terminate the ground through the pigtail connections or on the other end of the cable or it will increase the high frequency impedance and remove the effects of the shield. Note: See the VFD User Manual for more information in regards to power wiring to the drive and to the motor. Grounding Grounding the equipment to the panel and system ground is the most important aspect to look at when trying to mitigate EMI issues and prevent high frequency currents from effecting other equipment throughout the power network. A specific ground connection should be made between the VFD and the motor with a direct point of contact. From there the VFD should be grounded to the facility ground along with any other devices that are in the cabinet or are used for controls. Painted back panel creates an insulation barrier between the Ground lug and grounding cable that can cause a bad ground connection. Ground cables should be sized to the same size of the power wiring to again maintain the proper current level protection. Braided ground connections have lower high frequency impedance than round conductors and are preferred. We view there a three level approach to a single drive installation, starting with the accepted standard. Use metal conduit that has a grounding strap on the outside of the conduit. Connect this strap to the VFD enclosure and also the motor grounded frame. Inside of the conduit, run a grounding conductor connecting the motor ground to the VFD ground. A shield is preferred over the cable, connecting the shield to the ground bus in the drive and terminating the motor end to the grounded motor. The better method would be to use shielded armor cabled or PVC jacketed shielded cable instead of conduit from the drive to the motor. Use similar grounding practices as above. The best method is to use shielded armored cable on the line and load side of the VFD, connecting all grounds as above. The preferred method of using shielded or armored power cable is due the return path for common mode noise is the shield or armor. Unlike conduit, the shield or armor is isolated from accidental contact with grounds by a PVC outer coating. The coating makes the majority of noise current flow in the controlled path and very little high frequency noise flows into the ground grid. The armor prevents EMI coupling to 2 EATON CORPORATION www.eaton.com

Application Note AP040076EN other cables because the radiated emissions are minimal as the armor completely covers the power wires. Communication Wiring For communication wiring similar considerations should be made as the control wiring. Depending on the communication protocol used will determine in many cases the type of cable to use along with its connectors. The communication wiring should be separated from any high voltage wiring (above 50Vdc) and if it should cross any high voltage wires (above 50Vdc) at a 90 angle. When running parallel with any high voltage wires they should be spaced as far away as it is permitted to prevent any EMI interference. Shielded Twisted pair cable is suggested with the shield terminated on one end will provide the best defense against EMI in in the system. Analog Control Wiring For analog control wiring similar considerations should be made as the control wiring. The analog control wiring should be separated from any high voltage wiring (above 50Vdc) and if it should cross any high voltage wires (above 50Vdc) at a 90 angle. When running parallel with any high voltage wires they should be spaced as far away as it is permitted to prevent any EMI interference. Shielded Twisted pair cable 600Vac is suggested with the shield terminated on one end will provide the best defense against EMI in in the system. Other Components For other power components such as power supplies proper wiring size should be used along with a direct connection to the ground bar or lug. We suggest you look at the devices manual for proper connections. EATON CORPORATION www.eaton.com 3

Application Note AP0400076EN VFD Wiring System Considerations When looking at a VFD wiring system there are several aspects that need to be consider due to interaction between various wiring in the system itself. These are outlined below: 1. Electromagnetic Interference (EMI) can be carried on the ground back to the drive via the ground connection shown above. 2. With motor cables and control cables running in parallel at a close proximity the PWM wave on the motor cable can be induced into the control wiring causing errors in the voltage levels due to the wires acting like capacitors, with Electromagnetic Interference can be transmitted. 3. With motor wires running in parallel and in proximity of the ground cabling the PWM can induce voltage onto the ground through Electromagnetic Interference which can be transmitted back to the drive and motor. 4. With other AC cables running near any output motor cables the PWM that is being transmitted through the motor cables from the drive as well as the AC voltage lines through Electromagnetic Interference. This induced voltage can then cause issues to the motor, drive and other devices in the system. 5. With other AC cabling ran in parallel and close proximity of any control wiring the AC voltage can be induced in the low voltage control wiring through Electromagnetic Interference, this will cause issue with the control voltage and current signals when the drive or other devices are trying to monitor them. 6. With grounds going to the motor, the large voltage waves of the PWM output on the drive if not properly grounded will feed stray voltage and currents back from the motor into the drive and other devices on the ground bus. 4 EATON CORPORATION www.eaton.com

Application Note AP040076EN Additional Help In the US or Canada: please contact the Technical Resource Center at 1-877-ETN-CARE or 1-877-326-2273 option 2, option 6. All other supporting documentation is located on the Eaton web site at www.eaton.com/drives Eaton 1000 Eaton Boulevard Cleveland, OH 44122 USA Eaton.com 2014 Eaton All Rights Reserved Printed in USA Publication No. AP040076EN July 2014 Eaton is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners