Water. MacR6. Data logger. PLUM Ltd. Ignatki 27a, Kleosin, Poland

Similar documents
Ultimate Server Client Software

Novel AMR technologies and Remote Monitoring

Data Loggers for Real Time Temperature Monitoring - WiFi

Sophos Mobile Control User guide for Android

FT-1000/GPS-N. System of remote monitoring and control of physical

What is our purpose?

Temperature & Humidity SMS Alert Controller

Premium Server Client Software

Counter for Energy. We make energy measurable and secure your future.

GUANGZHOU SANJING ELECTRIC CO., LTD

XWEB EVO Supervisor and Monitoring Systems. November 2014

Sophos Mobile Control User guide for Android. Product version: 4

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

YZP : SAUTER Vision Center

SIEMENS. Operating Web Server. Opening program and changing message text properties

Indoor / Outdoor Antenna

This section will focus on basic operation of the interface including pan/tilt, video, audio, etc.

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Device Log Export ENGLISH

Water Metering System SmartMeter Prepayment. SmartMeter Prepayment. Water Metering System

minova technology electronics

User Guide FOR TOSHIBA STORAGE PLACE

Weather Capture Software Guide Version 1.4 Revision: June

My2B. MyALARM2 GSM/GPRS Datalogger with Alarm Management

AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment

Using the T&D Thermo App with TR-7wf Data Loggers

MDS. Measured Data Server Online Measurement Network. Properties and Benefits »»» »»»» ProduCt information

ABB solar inverters. User s manual ABB Remote monitoring portal

ROC Protocol Specifications Manual

Privacy Policy Version 1.0, 1 st of May 2016

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

WISE-4000 Series. WISE IoT Wireless I/O Modules

Smart Anytime, Safe Anywhere. Climax Home Portal Platform. Envisage and Enable a Connected Future

Copyright Copyright 2014 SerVision Ltd. All Rights Reserved.

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series

F454. Web Server. User Manual 05/12-01 PC

IceSpy Mini System. Makes light work of small to medium wireless environmental monitoring FOOD INDUSTRY SPECIFIC PRODUCT SOLUTIONS

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

Lockout Specification BW Clip Maintenance-free single gas detector

Tecnosystem Group was founded in 1988 for operating in the field of

Radiological Assessment Display and Control System

Sample specifications for an effective Flow Monitoring Services RFP

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

User Guide. Temperature and Humidity Datalogger. Model 42280

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

Zertico Rack Monitoring Unit

Temperature Alert. LAN-based Temperature and Humidity Data Logger

My home. Mobile phone application. Instructions for use and installation. For DELTA DORE GSM transmitters and transmitter control units.

VL Touchscreen Alarm. A Brilliantly Crafted Touchscreen Security System that Revolutionizes Your World

4-CH Hybrid Digital Video Recorder

DroboAccess User Manual

A full range of monitoring solutions for surge arresters Answers for energy.

HYDRUS ULTRASONIC METER

Water Distribution System Wireless Monitoring Solutions


OPENweb. Efficient controlling at the highest level.

AirPatrol WiFi Full Manual V1.0

mysensors mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide Information to Users Inside the Box mysensors Ethernet Gateway Quick Start

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

D-Moticam BTW8 Microscope Tablet / Camera Use and Care Manual

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Wireless Installer. User s Guide. Revision 1.0 September 2, Copyright 2014 LigoWave

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

A project to optimise quality and energy efficiency must include metering

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

AXIS 262+ Network Video Recorder

Ron 3025 Crane Scale with 1"/25mm Display

E L E C T R O N I C V E H I C L E R E G I S T R A T I O N S Y S T E M. data management

Equivital Wireless Physiological Monitoring

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

Energy Communication Unit (ECU)

Your fleet leading the way Digital tachograph solutions and services

HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic

Qvis Security Technical Support Field Manual LX Series

User manual BS1000 LAN base station

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

Polyphase kwh Electricity Meter

On the M-BUS Interface you can add up to 60 M-BUS Devices (60 unit loads).

Wireless Day / Night Cloud Camera TV-IP751WIC (v1.0r)

DataView DVTH Data Logger for Temperature and Humidity

KCU Communication. PC Software Installation and User s Guide For KCU-30 / KCU-40 / KCU-50 modules. System requirement: Windows XP or above

Downloading Electro Scan Smartphone App From Google Play* * Previously known as The Android Market

SOFREL PCWin2. SCADA Central Station

SNMP Web Management. User s Manual For SNMP Web Card/Box

Data Management. Graph of Wind Speed distribution, Power Curve and production

WIRELESS INSTRUMENTATION TECHNOLOGY

Hydro MPC Integrated Pump Systems and HVAC Applications GRUNDFOS HYDRO MPC

Wireless Data Logger. Collect, Manage and Monitor Your Valuable Data via Wireless Communication. Register and Manage Remote Units by Groups

MEGAPOLIS Complex Information System

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

Comparative Analysis of Several Real-Time Systems for Tracking People and/or Moving Objects using GPS

GSM Alarm System User Manual

SITRANS F M MAG 8000 Precise Metering with battery powered water meters. sitrans f

IP Camera (L series) User manual V1.1

Bluetooth Web Enabler

Nardalert S3 Non-Ionizing Radiation Monitor

En Wireless Mobile Utility (Android) User s Manual. D610, D600, D7100, D5300, D5200, D3300, Df

IP Sensing Water & Wastewater AMR/SCADA System

FP Desktop Professional Software

SBBWU PROXY SETTING IT CENTRE How to Set a Proxy Server in All Major Internet Browsers for Windows

Transcription:

MacR6 Data logger PLUM Ltd. Ignatki 27a, 16-001 Kleosin, Poland plum@plum.pl www.plum.pl

OPTICAL - INTERFACE Lead free IP 68 Readout via GPRS Standard protocol support IP 68 sealing class * pressure sensor MacR6 flow recorder is an innovative telemetry device, automatically transmitting data to water distribution network administrators through GSM infrastructure. MacR6 is used to support the processes of settlement, profiling water consumption among consumers, active control of the water supply network parameters (flow and pressure) and detection of emergency situations. It can be a key element of a stationary system for remote reading of measuring devices. MacR6 is a universal solution that works with all measuring devices (water meters, flow meters), by registering flow through factory impulse modules. Two versions: MacR6 P (flow) and MacR6 PC (flow + pressure) Applications Water treatment plants Pumping stations and hydrophore plants Industrial and public utility facilities Custom water collecting facilities Multiple family buildings - main water meters Measurement of the water supplied to separate municipalities - transmission water meters Zones and subzones calibration of the water supply network model Management of the water supply network Key element of a stationary system for remote reading of measuring devices MacR6 features Installation and device configuration process simplified to a minimum Replaceable battery in the device mounting location Use of secure TCP/HTTPS Internet protocols, ability to function in GSM 2G and 3G Open TCP formula and transmission standard enables interaction with IT solutions of different manufacturers Device geolocation function Very high resistance to mechanical damage (EN 62262 norm) Local readout option

Technical specification Powered by replaceable lithium battery Operating time: 10 years when reporting once a week, 5 years when reporting once a day IP 68 Ingress Protection Rating Working temperature range of -25 o C to +55 o C Equipped with optical interface compliant with the IEC 62056-21 standard Internal clock synchronized with the NTP time server Implemented internal ceramic antenna (option of external installation) Storage and transmission of the installation s location GPS coordinates LCD display of: alarms, battery status, GPRS network status, data transmission status, water consumption in the current month, current meter, current peak hourly water consumption, water consumption in the previous month, counter status at the end of the previous month Ability to read data via applications for local PC: MacODCZYT and tablets/smartphones: MacReader and MacReader+ Pressure sensor measuring range 0-10 bar, measurement accuracy: standard 1% (relative to the range), increased +/- 0.1% (optional version) for MacR6 PC version Advantages Develops an active leak control system Enables proper selection of water meter size Speeds up the settlement process Allows to detect fraudulent recipients Allows to optimize the costs of water supply system operation Provides precise information on the parameters of the water supply network - network calibration Example of MacR6 system operation Water meter impulse module MacR6 ewebtel System Users OptoBTEx GPRS Recorders configurator McReader Server

Data transmission Data transmission via GPRS, asynchronous/synchronous mode, GSM 2G and 3G operation TCP and HTTPS Internet protocol, NTP time server Data recording period from 1 to 60 minutes Transmission period from everyday to once a month (in case of emergency, every 30 minutes) Possibility of scheduling data transmission on certain days of the week Alarms Exceeding maximum flow alarm Reverse flow alarm Interference alarm Possible leak alarm, based on a special algorithm Exceeding the upper and lower pressure limit alarm Low battery alarm Registration of GSM network absence Infrared Bluetooth OptoBTEx Recorders configurator MacReader/MacReader + Optical head consistent with IEC 62056-21 equipped in a Bluetooth transmitter. Mobile application for Android devices (smartphones, tablets). Available for free download from Google Play. Mobile application for Android devices (smartphones, tablets) used for reading the recorded data. Available for free download from Google Play. PLUM Ltd. Ignatki 27a, 16-001 Kleosin, Poland plum@plum.pl www.plum.pl

ewebtel Management system ewebtel is a management platform for comprehensive surveillance of the monitored water supply network. It allows for graphical visualization of data transferred from water meters, geolocation of devices with history of recorded data, and generating reports on: monthly water consumption for individual customers or groups of customers, occurrence and duration of failures, history of use for a particular customer or groups of customers, ewebtel allows you to group devices according to various criteria such as area, zone, technical person, etc. Additionally, the system allows you to create and edit data sets of water meters. Advantages of ewebtel It allows you to optimize the operating costs of meter readings, enables analysis of correct selection of water meters and facilitates management of the water supply network impulse module Water meter MacR6 ewebtel System Users GPRS Server

Features of the ewebtel System The system is based on web browsers (IE, Firefox, Chrome, etc.) It has the ability to export data in CSV and TXT formats Allows personalization with password protection of the configuration parameters System in Polish (System in English) Data archived on a server PLUM Ltd. Ignatki 27a, 16-001 Kleosin, Poland plum@plum.pl www.plum.pl