K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

Similar documents
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

RM4TG20 three-phase network control relay RM4-T - range V

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A

Pendant control stations 6

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

R.C.C.B. s two-pole LEXIC

Safety dialogue solutions

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Safety detection solutions

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Safety automation solutions

Type: DILM32 10(24V50HZ) Article No.:

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Type: DILM9 10(24VDC) Article No.:

Manual motor starter MS116

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Electronic overload relay EF19 and EF45

Electronic overload relay EF65, EF96 and EF146

Cross-beam scanning system to detect slim objects. 100 mm in

Rotary Disconnect Switch Specifications

Bimetallic Overload Relay Specifications

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

ADM1TE 5/30A DIN rail single phase two wire energy meter

Technicaldata General

Preventa Machine Safety Products

Catalog. Modular DIN rail components Installation contactors

Series 8146/5-V37 and Series 8150/5-V37

Manual Motor Starter MS 116 up to 16 A Technical Data

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Safety technique. Emergency stop module BO 5988 safemaster

Pluggable interface relays CR-P Pcb relays

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

ELECTROMAGNETIC DISC BRAKES

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Technical catalogue. Modular DIN rail components Installation contactors

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Vario-Series Accessories

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

48 SERIES Relay interface modules 10 A

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Plug and Socket Devices CES 63 A Series 8579

Quick Connect. quick - simple - efficient.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Thermal-Magnetic Circuit Breaker M1-..

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

49 Series - Relay interface modules A. Features

NDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD

8146/5 Series Breaker Panelboards

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Catalogue May EasyLine XLP Fuse Switch Disconnector pole

Terminal Boxes Series 8146

Selector Switch Type 08

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Givare NC-SRS 280 och 880

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

RY2 miniature industrial relays

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Knob Potentiometer with Switch

Three-phase monitoring relay CM-PFE

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

FAQs-Main switchboard design criteria

SURGE PROTECTIVE DEVICES

E-STOP relays, safety gate monitors

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

HERZ-Thermal Actuators

ASSEMBLED SOCKET-COMBINATIONS

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

1/2" (12.7 mm) Conductive Plastic and Cermet Potentiometer

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Absolute Rotary Encoder E6CP

FUSERBLOC. 20 to 1250 A Manual operation. 142 General Catalogue SOCOMEC. Fuse combination switches

Panel Meters and Controllers Modular Panel Meter Type EDM 35

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Transcription:

Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam switch head type Type of operator Rotary handle padlocking Presentation of legend Cam switch function Return Switching angle 90 Type of measurement Off position Harmony K Complete cam switch K1 12 A Front mounting Ø 22 mm hole With front plate 45 x 45 mm Black handle, length = 35 mm Without With metallic legend, 0 - L1 - L2 - L3 black marking Ammeter switch Without For 3 circuits With Off position Switching positions Right: 0-90 - 180-270 IP degree of protection IP65 conforming to NF C 20-010 IP65 conforming to IEC 529 [Ui] rated insulation voltage 690 V degree of pollution 3 conforming to IEC 60947-1 [Ithe] conventional enclosed thermal current 10 A Rated operational power in W 8300 W AC-21/400 V 3 phases conforming to IEC 60947-3 600 W AC-3/230 V 1 phase conforming to IEC 60947-3 4800 W AC-21/230 V 3 phases conforming to IEC 60947-3 2200 W AC-23A/690 V 3 phases conforming to IEC 60947-3 2200 W AC-23A/500 V 3 phases conforming to IEC 60947-3 2200 W AC-23A/400 V 3 phases conforming to IEC 60947-3 1500 W AC-3/690 V 3 phases conforming to IEC 60947-3 1500 W AC-3/500 V 3 phases conforming to IEC 60947-3 1500 W AC-3/400 V 3 phases conforming to IEC 60947-3 1500 W AC-3/400 V 1 phase conforming to IEC 60947-3 1500 W AC-23A/230 V 3 phases conforming to IEC 60947-3 1100 W AC-3/230 V 3 phases conforming to IEC 60947-3 10500 W AC-21/500...660 V 3 phases conforming to IEC 60947-3 [Ie] rated operational current AC 5.6 A at 230 V AC-23A 3 phases conforming to IEC 60947-3 4.8 A at 400 V AC-23A 3 phases conforming to IEC 60947-3 4.6 A at 230 V AC-3 3 phases conforming to IEC 60947-3 3.8 A at 500 V AC-23A 3 phases conforming to IEC 60947-3 3.3 A at 400 V AC-3 3 phases conforming to IEC 60947-3 2.8 A at 690 V AC-23A 3 phases conforming to IEC 60947-3 2.8 A at 500 V AC-3 3 phases conforming to IEC 60947-3 1.8 A at 690 V AC-3 3 phases conforming to IEC 60947-3 3 A at 230 V AC-15 conforming to IEC 60947-5-1 2 A at 400 V AC-15 conforming to IEC 60947-5-1 1 A at 500 V AC-15 conforming to IEC 60947-5-1 Electrical durability Operating rate 500000 cycles AC-3 500000 cycles AC-23 1000000 cycles AC-21 1000000 cycles AC-15 8.333 cyc/mn AC-15 2.5 cyc/mn AC-3 2.5 cyc/mn AC-23 2.5 cyc/mn AC-21 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Mar 9, 2013 1

Short-circuit current Short circuit protection 10000 A 16 A by cartridge fuse, type gg [Uimp] rated impulse withstand voltage 6 kv conforming to IEC 60947-1 4 kv in isolating function Contacts operation Positive opening Electrical connection Mechanical durability CAD overall width CAD overall height CAD overall depth Product weight Slow-break With Captive screw clamp terminals solid, 1 x 2.5 mm² Captive screw clamp terminals flexible, 2 x 1.5 mm² 1000000 cycles 45 mm 50 mm 69 mm 0.19 kg Environment Standards Product certifications Protective treatment Ambient air temperature for operation -25...55 C Ambient air temperature for storage -40...70 C EN/IEC 60947-5-1 for control circuit EN/IEC 60947-3 for power circuit CENELEC EN 50013 UL 240 V 0.33 hp 1 phase 2 -pole(s) UL 240 V 1 hp 3 phases CSA 240 V 3 hp 3 phases 2 -pole(s) CSA 240 V 1 hp 1 phase Shock resistance 30 gn conforming to IEC 68-2-27 Vibration resistance 5 gn, 10...150 Hz conforming to IEC 68-2-6 Class of protection against electric shock Class II conforming to NF C 20-030 Class II conforming to IEC 536 TC 2

Dimensions Drawings Operating Head and Body with Plastic Base Front Mounting by Ø 22 mm/0.87 in. Hole a1 e 90.5 mm/3.53 in. support panel thickness 1 mm to 6 mm./0.039 in. to 0.24 in. 3

Technical Description Link Positions (Factory Mounted) Marking Angular Position of Switch Switching Program Convention Used for Switching Program Representation Contact closed Contact closed in 2 positions and maintained between the 2 positions Sealed assembly for auto-maintain control Overlapping contacts 4

contacts). Example: Spring return position: for a switching angle of 90, spring return is over 30 after the last position (for a maximum of 3 simultaneous 5