HXSP-2108E Serial to TCP/IP Serial Device Server User Manual

Similar documents
Follow these steps to prepare the module and evaluation board for testing.

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

LBNP RS-232/485/422 serial device server. User manual

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

USR-TCP232-T Hard Version: V2.0 Doc Version: V

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

UPS Network Interface. Quick InstallationGuide

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Operation Manual of EX9132C-RS485. Serial to TCP/IP Converter

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

Operation Manual of EX-9132C-2. Serial to TCP/IP Converter

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

1 Serial RS232 to Ethernet Adapter Installation Guide

Portable BACnet /IP to MS/TP Router

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

One Port Serial Server Users Manual Model ESP901, ESP901E

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

1. MOXA NPort Express TCP/IP to RS-232 server

CS 326e F2002 Lab 1. Basic Network Setup & Ethereal Time: 2 hrs

Computer Networks I Laboratory Exercise 1

User Manual Revision English

MODBUS TCP to RTU/ASCII Gateway

NB6 Series Quality of Service (QoS) Setup (NB6Plus4, NB6Plus4W Rev1)

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

1 INTRODUCTION. This document describes the procedure to upgrade LTMR.

1 crossover cable. the PCs. network

Prestige 314 Read Me First

Setting up VPN Access for Remote Diagnostics Support

Firewall VPN Router. Quick Installation Guide M73-APO09-380

Multi-Homing Dual WAN Firewall Router

T3 Mux M13 Multiplexer

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

HWg-STE HWg-STE PoE MANUAL

enervista UR Setup Software Quick Connect Instructions:

Application & Quick-Start Guide

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

Model 2120 Single Port RS-232 Terminal Server Frequently Asked Questions

EZL-50L User s Manual

Application Note. Terminal Server G6

EZ-View Network Communications Guide

User Manual. Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP)

Wireless LAN g USB Adapter

Serial over Ethernet Device Server. User s Manual

FBs-CM25/CM55/CBE. Ethernet Module. User s Manual

Bercut-ETL Ethernet/Gigabit Ethernet loopback

Special Note Ethernet Connection Problems and Handling Methods (CS203 / CS468 / CS469)

Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield:

Guideline for setting up a functional VPN

User Manual Revision English

Beckhoff TwinCAT. Assigning IP Addresses to Beckhoff Ethernet Devices

Job Aid Pre-Installation Information S8500 Media Server

Process Control and Automation using Modbus Protocol

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Configuring the WT-4 for Upload to a Computer (Ad-hoc Mode)

Procedure: You can find the problem sheet on Drive D: of the lab PCs. 1. IP address for this host computer 2. Subnet mask 3. Default gateway address

F2103 GPRS DTU USER MANUAL

EMG Ethernet Modbus Gateway User Manual

UDS2100 Quick Start Guide

TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series

Schneider OS-Loader usage via Ethernet or USB.

Serial Over IP Ethernet Device Server

User Manual Revision English

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

EDGE FX Network configuration

SOHO 6 Wireless Installation Procedure Windows 95/98/ME with Internet Explorer 5.x & 6.0

ON HOLD ANNOUNCER. Once you receive your audio announcer, check the packaging to ensure that all of the following items are enclosed:

1 PC to WX64 direction connection with crossover cable or hub/switch

eprism Security Suite

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

User Manual Network Interface

MODBUS TCP to RTU/ASCII Gateway. User s Manual

SNMP Web Management. User s Manual For SNMP Web Card/Box

USER MANUAL. VS-81H 8x1 HDMI Switcher MODEL: P/N: Rev 4

Getting Started KX-TDA5480

Embedded Ethernet Interface Using Arm Processor

TSX ETY 110 Module 8

Debugging Network Communications. 1 Check the Network Cabling

CCNA R&S: Introduction to Networks. Chapter 5: Ethernet

PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

This document explains how to use your Web Browser to configure the 100BaseT Print Server models

Prestige 650R-31/33 Read Me First

LS-101 LAN to Serial Device server. User s Manual

Configuring the WT-4 for Upload to a Computer (Ad-hoc Mode)

User Manual. EtherUSB

Volume. Instruction Manual

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

HomeWorks P5 Processor Ethernet TCP / IP Networking Specification

Technical Notes TN 1 - ETG FactoryCast Gateway TSX ETG 3021 / 3022 modules. How to Setup a GPRS Connection?

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

FSW-0505TX/0805TX 5/8 Port SOHO 10/100Mbps NWay Switch FSW-0505TX FSW-0805TX. 5/8 Port SOHO 10/100Mbps NWay Switch. User s Manual. (Revision 1.

TCP/IP SUPPLEMENT SCALE NETWORKING

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

CCNA 1: Networking Basics. Cisco Networking Academy Program Version 3.0

Written examination in Computer Networks

Communication Controller with IP services for leased lines and wireless links Radio Activity S.r.l.

Transcription:

HXSP-2108E Serial to TCP/IP Serial Device Server User Manual HXSP-2108E-A RS-232 to Ethernet TCP/IP Serial Device Server HXSP-2108E-B RS-485/RS-422 to Ethernet TCP/IP Serial Device Server

1. Product Introduction Product Description Technical Specification External Connector Installation 2. Operating Guide HXSP-2108E Configuration Communication Test Stand-alone Test Running Test 3. Application Example The Long Range Data Transmission System Centralized Control 1

1. Product Introduction Http://www.hexin-technology.com/ 1.1. Product Description The HXSP-2108E Serial to TCP/IP Serial Device Server is a bidirectional switching and transmission device from serial port to Ethernet TCP/IP protocol. It changes the traditional serial communication to Ethernet communication. It realized speed networking for serial device. The converter uses transparent communicate protocol, so that the user need not understand complex Ethernet TCP/IP protocol, need not modify old serial program, save your valuable time and money. The low price will improve your product s core competition, the easy, flexible configuration and High-availability will satisfy your steep demand, it is your ideal select. 1.2. Technical Specification Serial Port Standard: Accord EIA RS-232, RS-485, RS-422 standard Ethernet Port Standard: Accord 10Base-T/100 Base-T standard Auto-detecting 10/100Mbps Ethernet interface Connector: RJ-45, RS-232(HXSP-2108E-A), RS-485/RS-422(HXSP-2108E-B) Baud Rate: 300bps~115200bps Loading: RS-485/422 side support 32 or 128 nodes loopback Serial Port Protection: 600W surge protection, 15KV ESD protection Serial Port Transmission Range: RS-485/422 side 1200M, RS-232 side 15M Protocol: Support TCP, UDP, ARP, ICMP Ethernet Port Rate: 10/100Mbps Ethernet Port Working Method: full-duplex or half-duplex External 9VDC power supply, support Power Supply 7 to 56 VDC Working Temperature: -10 to 80 Dimension: 92mm x 64mm x 24mm 1.3. External Connector 2

1.4. Installation The HXSP-2108E Serial to TCP/IP Serial Device Server use WINDOWS application program ezconfig to set parameter through network. Therefore, user need install the network card in computer and set network environment. If it needs connect many HXSP-2108E equipments, user also need the network switchboard or HUB 1) Install the network card and set IP address and subnet mask. IP address can be set casually if no connection with other computers in one identical network, such as: 192.168.X.Y (Note: In one identical local area network, X same, Y random, no duplication), the code of the subnet mask is 255.255.255.0.If the computer is in the local area network, please follow the network administrator s setting. 2) Connect the computer network card to HXSP-2108E by Crossover Ethernet Cable or connect directly the network switchboard or HUB by straight Ethernet cable. 3) Connect serial port of HXSP-2108E with serial port of embedded equipment or PC machine by RS-232 cable (for testing HXSP-2108E-A) 4) HXSP-2108E would start to work after connecting power. PWR light is on and RUN light twinkles, which demonstrate HXSP-2108E work normally. LINK light is on, which demonstrates the correct physical connection. ACT light begins to twinkle when there is data packet receiving and dispatching, which shows the smooth connection between HXSP-2108E and identified network. Then, the connection process is completed. 3

2. Operating Guide 2.1. HXSP-2108E Disposition HXSP-2108E adopt the transparent transmission means to deal with data, namely any data the serial port receives is retransmitted to the network. The user may use any communication protocol to realize network communication without changing the original procedure. Then HXSP-2108E adopts WINDOWS application procedure-ezconfig and disposes parameter through network. Below is the initial contact surface: Buttons function instruction: SEARCH(S): To search HXSP-2108E converter in network, with the result demonstrated in physical address tabulation frame. After selecting one physical address, you can read or set this converter parameter. READ(R): To read the current converter parameter. You can automatically read the corresponding parameter in the physical address tabulation or choose to read one in it. WRIAE (W): Button W is effective when you choose the converter in the physical address tabulation frame. You can insert any data in the corresponding frame. Click the button to write it into the converter. Attention: Changing physics address leads to the replacement network connection which takes rather long time or using DOS order ARP-D to eliminate the ARP buffer to operate. EXIT(X): To close ezconfig, or click the ESC key. The disposition step is as follows: 1. Correctly install and connect HXSP-2108E (RF. 1.4), move the ezconfig procedure, and 4

click [Search]. Physical address is shown in the physical address tabulation frame after the software found the converter as below: 2.Choose the physical address and the other parts would be efficient. Now read and set the converter parameter. Which can be reread to relative switch parameter is confirmed to be OK. 3. You can test its reach capability after setting is completed using PING test in DOS windows. Note: The computer must be in the same identical local area network with the converter as follows: 5

2.2. Communication Test 2.2.1. Stand-alone test After the disposition completed, we need to carry on simple test to confirm the accuracy of the setting and HXSP-2108E. The single plane test adopts the means of receiving and dispatching of the data packets between the super terminal (the RS232 serial port) and WINDOWS application procedure e1test (Ethernet TCP/IP) to confirm. The single plane test step is as follows: 1) Correct install and connect HXSP-2108E (RF.1.4), moves e1test procedure, set the remote IP address with the remote port to be HXSP-2108E and local port to be HXSP-2108E as remote port as follows: 6

[PC IP address] Choose PC IP address. The procedure automatically searches all IP address of the computer and chooses the most possible one. If wrong, you can choose through the frame. [Local port] The port is to receive a TCP/UDP package. [Communication protocol] Choose UDP protocol. Better not to choose TCP protocol [Interception] Intercept the TCP connection of HXSP-2108E. [Module IP Address] To show opposite party s IP Address. [Module port] To show opposite party s port. [HEX DISP] Choose it to show receiving data according to HEX DISP, or as ASCII code. [Clear] Clear the contents of receive data frame. [Hex send] Send according to hexadecimal system. Note: The data only can be 0~9, a~f or A~F, no blank in it. [Automatic send] Automatically send the data in the fixed time according to the sending cycle. [Send cycle] Set the automatic sending cycle (ms). [Send by handing] Send TCP/UDP data packet to assigned IP and port. [Clear count] Clear the transmitting and the receiving count. 2) To connect the serial port of HXSP-2108E with the serial port of PC machine by RS232 cable; to open the super terminal, and to choose the port which connects HXSP-2108E to set relative baud rate (baud rate parameter disposed with ezconfig, automatically to be 19200), 8 data positions, 1 stop position, no verification and no class controls. 3) We have completed the hardware connection and the software establishment, now we can carry on normal communication. The character inputted in the super terminal would 7

appear in the e1test receiving window (whether the super terminal can reshow tbe transmission character is decided by the corresponding set of converter), otherwise the e1test transmission information can be seen in the super terminal window. 2.2.2. running test The design goal of HXSP-2108E is to realize network communication by serial port with the extremely low cost. There is no requirement to understand TCP/IP protocol well and no regulation of the serial transmission format. You can definite any serial communication protocol. And you don t need change current communication procedure to realize the network communication. Below we can simulate the relative test under this circumstance: To dispose two HXSP-2108E converters, set their remote IP addresses to be the ones of the opposites. (Two HXSP-2108E should dispose in the same identical local area network), exchange their local port and remote port (opposite party s remote port to be its local port and the opposite party s local port to be its remote port, others set as required), and connect the serial port with its the PC serial port (Could be different serial port of one PC). To open the super terminal and set the relative parameter and the communication is established well. And the character input in one terminal will be shown in another terminal. 3. Application example 3.1 The long range data transmitting 3.2 Concentrate control system 8