NS 3000 threephases UPS

Similar documents
on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

Phase Modular Finally the benefits of Modular ups are for all

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

PowerGem Pro Uninterruptible Power Supply

RIELLO ELETTRONICA. Master HP

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

4.0 UPS dedicated to ICT for unmatched energy savings

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

LAP ENERGIA PARA DATACENTERS

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

Eaton 93PM UPS Where aesthetics meet intelligence.

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

Connectivity. PowerShield 3. Communications Software

Software and accessories

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

UNINTERRUPTIBLE POWER SUPPLY (UPS)

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

VISION UPS UPS PRODUCT CATALOGUE

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Communication and connectivity the ideal solution for integrated system management and data integrity

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

SNMP INTERFACES AND SOFTWARE FOR SINGLE-PHASE UPS

Options and monitoring

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Tender Technical Specification. For Three phase UPS, on line double conversion (VFI) 30 kva 30 kw

SG Series UPS kva three phase 400 Vac

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

The UPS for the highest security in industry and data centres

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

Liebert NXC from 10 to 200 kva

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

PRODUCT PRESENTATION PROTECT B.PRO YEAR 2013 NOVEMBER 2012 DATA & IT, SBU C-UPS, PM/SR

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Technical Data. back-up time in minutes 100% load % load

UPS system for emergency lighting and smoke extraction

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers

Galaxy 7000: Unitary Specification guide: Single UPS, three-phase, 160 to 500 kva

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

SNMP Web Management. User s Manual For SNMP Web Card/Box

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

MAJORSINE Power Inverter

Galaxy VM. Three-phase power protection. schneider-electric.com

Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理. Schneider Electric - Division - Name Date

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

MGE Galaxy /200/250/300/400/500 kva Power efficiency for business continuity

Product catalog ABB UPS products and solutions Power protection for critical infrastructures

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

SG Series UPS kva. high efficiency systems

TOSHIBA G /100/160/225 kva

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Chloride 80-NET from 60 to 500 kw. Secure Power for Mission Critical Applications

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work

UPS MANAGEMENT SOFTWARE

TECHNICAL SPECIFICHE SPECIFICATIONS MULTI DIALOG

Uninterruptible Power Supply

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

GAMATRONIC ELECTRONIC INDUSTRIES LTD.

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

10000HXL31/15000HXL31/20000HXL31

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

Flexus APPLICATIONS EMERGENCY LIGHTING SUITABLE FOR FLEXIBILITY ADVANCED COMMUNICATION ZERO IMPACT SOURCE BATTERY CARE SYSTEM LOW MANAGEMENT COST

GE Digital Energy. SG-CE Series UPS kva three phase 400 Vac Uninterruptible Power Supply (UPS) imagination at work

QuickSpecs. Compaq Uninterruptible Power Systems M ODELS

UPS MANAGEMENT SOFTWARE OPTIONS

Thyristor-controlled power supplies and battery chargers

ABB PSPS Erich Steinmann; Generator control-2013

APC by Schneider Electric MGE GALAXY 3500 Uninterruptible Power Supply Guide Specifications 10 kva to 40 kva in / V Solution

Eaton 93PM UPS Efficient. Scalable. Innovative.

Eaton 93PM UPS Efficient. Scalable. Innovative.

Schneider Electric GALAXY VM Data Center Grade Three Phase Uninterruptible Power Supply Guide Specifications kva UPS

User Manual 1K/2K/3K Online UPS

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

Intelligent Power Distribution in the Data Center

TLE Series. Product Description kva / 400Vac / S1 KEY BENEFIT APPLICATIONS FEATURES

NeTYS PR VA

MASTERYS. Product technical specifications. MASTERYS UPS from 8 90 kva. Uninterruptible Power Supply Systems

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

UPS Management Software

Considering the effects of UPS operation with leading power factor loads

T200, PTP/IEEE 1588 Grandmaster Clock and

Transcription:

threephases UPS Data Center & servers Telecommunication devices Emergency applications (lights/alarms) Customized power solutions Electro-medical devices 10-20-30 kva threephase input, threephase output efficiency and reliability in power supply solutions

Product Overview Higher reliability Zero utility impact Flexible and friendly settings Excellent in efficiency Intelligent battery management Easy maintenance due the modular design HIGHER RELIABILITY The fully digital control with microprocessor allows more accuracy and data monitoring, assuring an excellent protection from the failures. NS3000 Series has a precise Self-Diagnosis system which constantly monitors its system operations and function of internal components, including intermediate parameters as voltage and current, general parameters as temperature and fan speed; detecting a potential problem the Self-Diagnosis sends an alarm or takes action. Self-Correction when senses a problem instantly will transfer the inverter to batteries or the load to a bypass source with zero interruption in power; if the alarm condition passes, the NS3000 automatically reverts in normal operation mode. NS3000 Series has split bypass line as standard to manage the alternative source. An intelligent control of fans is able to detect the own failure to avoid slow overheating of components. The NS3000 unit frame and cabinet are very robust and the manufacture is sturdy, moreover all internal components are already tropicalised as standard procedure assuring the installation in sea plants or marine environments. ZERO UTILITY IMPT The active power factor correction (PFC) in rectifier stage provide unbeatable 0,99 input power factor and less than 3% input total harmonics distortion (THD) in current, thus allowing installation where the mains power supply is limited in capacity, or compatibility with generators and eliminating interference with other critical equipment in the same network. FLEXIBLE AND FRIENDLY SETTINGS The LCD display is user friendly and very easy for understanding. The compact tower design offers a smaller footprint with maximum power density, thus enabling easy space planning and preserving valuable floor space. The internal space allows to install up to 2 batteries strings ensuring several minutes at typical loads, avoinding extra cost for additional battery cabinets. The NS3000 can work also in parallel configuration up to 6 units, the scalabilty of own architecture permits to invest at the beginning only for existing loads and then to expand the UPS systems according to on-site needs. The configurations available are Normal mode, Parallel, Ecomode as single or parallel, Load Bus Sync. The LCD display is user friendly and very easy for understanding.

Reliability and premium performance. the ideal solution to solve utility stability The G-TEC NS3000 Series is uninterruptible power supply (UPS) medium size online, the ideal solution to solve utility stability, supply clean and power continuity for very critical loads, where space-constrained room needs a compact, flexible and scalable solution. NS3000 Series is available in power capacities 10-20-30 kva three-phase input and output, with double conversion technology according to the VFI-SS-111 classification, as defined by the IEC EN 62040-3 standard. The system is with digital signal processor (DSP) controlled IGBT rectifier and inverter transformerless, with filters for disturbances suppression. EXCELLENT IN EFFICIENCY The transformerless with high frequency PWM modulation and IGBT 3-steps level technologies assure the best performance in efficiency for UPS in the market. The benefits of lowest energy consuption are presents also for low load levels. The cost saving in efficiency is not comparable with traditional UPS, thus it can lead the full initial investment recovery within few years. The efficiency in ECOMODE operation reaches up to 99%. The cooling cost for the NS3000 room are limited. INTELLIGENT BATTERY MANAGEMENT Wider input voltage window and frequency tolerances help to minimize transfer to battery, reducing the number of charging and discharging cycles extending the battery service life and optimising recharging time. The double-conversion technology protects and conditions against the full range of power irregularities, requiring limited transfer to battery. In parallel redundant configuration is possible to connect the units to common battery string to have full battery capacity also in case of one UPS failure. The NS3000 uses a three charging modes to meet the specifications of the most common battery types as sealed VRLA, AGM or wet lead acid, Ni-Cd. Temperaturecompesated charging monitors battery temperature and adjusts the charge voltage rate accordingly. The battery management system is able to manage the manual and automatic tests, monitoring battery health and remaining lifetime. The NS3000 UPS is provided with internal switch for disconnecting the internal batteries. EASY MAINTENANCE DUE A MODULAR DESIGN The NS3000 layout permittes the best access to all internal components. A modular concept has been adopted for the mechanical desing, in fact the components are easily replacing on site without any dedicated tools in a very short time. The key point of NS3000 Series is the facilitated maintenance operation because the power components are all on the removable tray. All the batteries are installed in horizontal position with hot-swappable feature. UPS - section and structure 3P+N 3P+N Bypass N Output 3P+N Load

Connectivity Devices OPERATING SYSTEMS SUPPORTED Windows 95-OSR2, 98, Me, NT 4.0, 2000, XP, 2003; Linux; Novell Netware 3.x, 4.x, 5.x, 6; Mac OS X, 9.x; IBM OS/2 Warp and Server; HP OPEN VMS; The most widely used UNIX operating systems such as: IBM AIX, HP UNIX, SUN Solaris INTEL and SPARC, SCO Unix and UnixWare, Silicon Graphic IRIX, Compaq Tru64 UNIX and DEC UNIX, BSD UNIX and FreeBSD UNIX, NCR UNIX. As standard the NS3000 has local monitoring software through serial port, the UPSilon provides user-friendly UPS management. The software displays real time information in the form of bar charts and values for critical data such as mains voltage, UPS load and battery charge. It allows remote interrogation of UPS logs and operating parameters to help diagnose alarms and potential fault conditions. When instructed the software performs an automated safe power down of the protected PCs and file sever. Advanced communication Series is equipped with a mimic led and graphic display that provides information, measures, states and alarms regarding the unit and load. Standard RS232 port and RS485 port with ModBus interface protocol. Direct Connection with Ethernet Network REPO (Remote Emergency Power Off) to power down the UPS through a remote emergency push button. Web/SNMP card allows UPS management across a LAN using any of the main network communication protocols - TCP/IP, HTTP and network interface via SNMP. In case of alert it can notify users and administrators via email; when prolonged power failure occurs the protected computer systems can be shutdown in a graceful manner. LINK RS232 RS232 Terminale ETHERNET NETWORK snmp trap shutdown Server 1 Relay/AS400 card is an easy interface for input/output dry contacts and AS400 series computer, the common manner for industrial and building management systems. Administrating Workstation web page shutdown Windows Workstation Server 2

Flexible and Scalable The flexible technology and control permit to meet the site needs, whenever the loads become critical the logic is able to work in Load Bus Sync with additional external transfer switch or with full UPS power capacity available in Parallel configuration up to 6 units. The scalable logic of allows the UPS systems to increase according to load demands and the redundancy parallel configuration N+1 supplies the most critical loads. The N+1 parallel redundancy assures the supply in case of UPS failure. All the unit must be the same power size and an optional parallel kit should be installed for the accurate equal load sharing. The parallel system can work in ECOMODE and with common battery as 1+1 configuration. Bypass Line Load Modular concept and customised solutions customised solutions G-Tec has extensive knowledge in customised solutions for various scopes and environments, such experience has been taken into consideration during the NS3000 development. In fact the unit is designed for quickest repairing, the intervention time is limited at replacement of modular components on site. Also the two internal battery strings are fully hot-swappable and easily removable. MODULAR CONCEPT The modular concept in design helps the product customization encountering the most demanding applications; for example marine UPS due the standard tropicalisation of internal components; preservation against dusty and hard environment using air filters and heavy mechanical IP degree protection. PRODUCED IN ITALY

Benefits in your choice Significant are the advantages selecting your UPS which make it the best choice for your needs, often the benefits become noticeable during the operating life of the system and for an Uninterruptible Power Supply all the stops are critical for your business. The compact tower design has small footprint and the wheels assure the easiest installation in limited spaces. The standard UPS cabinet allows the internal housing up to 2 strings of battery achieving the reasonable backup time for the loads eliminating costly and space-consuming external battery cabinets. The input PFC technology extremely optimizes the upstream infrastructure without over rating the supply devices (as input transformers, diesel gensets, switches, cables and other) and eliminating the harmonics distortion troubles. The unit is suitable also for leading power factor load without derating The high efficiency minimizes the amount of battery for equal autonomy time. The MTTR (Mean Time To Repair) the in the shortest in the UPS category due the modular concept, it means more availability of system, less cost in intervention and maintenance. has optimized the Services procedures and intervention. Green features COST SAVING IN EFFICENCY NS3000 has higher efficiency without compromise of reliability or performances, as matter of fact working in VFI Double Conversion Mode achieves the lowest power consumption already at the very low load rate. The top efficiency in online mode is provided by the innovative conversion technology at 3-steps level IGBT and an extremely careful in components selection focus to lowest power consumption. % Efficiency 100 98 96 94 92 90 88 86 84 82 80 78 76 0 10 20 30 40 50 60 70 80 90 100 0 % load NS 3020 traditional UPS 20 kva The premium class of NS3000 in power performance comparing with traditional in the market allows a 50% saving in energy usage. The NS3000 Series is an UPS self-paying with energy save and it can lead to a full initial investment recovery within three years.

Model 10kVA 20kVA 30kVA Main voltage 380V/400V/415V(line to line), 50/60Hz connection 3Ph+N+PE Power factor >0.99 voltage window +20%~-10%, full load -10%~-40%, power derating between 100% to 60% Frequency window 40-70HZ Bypass input Bypass voltage 380V/400V/415V Bypass voltage window +15% -20%, full load Frequency window ±5Hz Battery Battery voltage ±240VDC Charger power 18%*Power W Charger voltage precision 1% Output Voltage precision 1% (balance load),1.5% (unbalance load) Output voltage transient 5%(0~100% load step) Voltage THD (Total Harmonic Distortion) THD<1%(linear load),thd<5%(nonlinear load) Power factor 0.9 Frequency tracking range 50/60Hz±3Hz, adjustable Frequency precision (free running) ±0.02% Phase tolerance 120 ±0.5 (balance and unalance load) Voltage unbalance (100% unbalance load) ±1% Frequency tracking speed 0.5Hz/s to 5Hz/s, adjustable Crest factor 3:1 105% transfer to bypass after 1hour 110%, transfer to bypass after 10minutes Overload capabiltiy 125%, transfer to bypass after 1 minutes 150%, transfer to bypass after 5 seconds >150%, transfer to bypass after 200ms 125%, long time operation Bypass overload capability 125%< load <130%, last for more than 1 hour 130%<load<150%,last for more than 6 minutes >1000%, last for more than 100ms System System efficiency Normal mode: 95% ECO mode: 99% Battery mode efficiency 95% Battery configuration 12V, 40PCS (36~44pcs acceptable) Display LCD+LED, Keyboard EMI IEC62040-2 IEC61000-4-2(ESD) EMS IEC61000-4-3(RS) IEC61000-4-4 (EFT) IEC61000-4-5 (Surge) Insulation resistance >2M (500VDC) Dielectric strengh (input,output to PE) 2820Vdc, leakage current lower than 3.5mA, no flashover in 1 minute Surge protection Comply with IEC60664-1 class IV, endure surge of 1.2/50us + 8/20us higher than 6KV/3KA IP class IP20 Interface (Communication Ports) RS232, RS485 Mod Bus, Dry contacts, SNMP card, EPO, Generator interface Installation/Connection Operation temperature 0-40 C Relative humidity 0-90% (non-comdensing) Noise (db) <55dB Weight (kg) (empty) 106 118 Dimension (W*D*H)(mm) 540x690x1240

Rev. 27.05.2013 G-Tec customer care G-TEC Service, our technical assistance facility uses highly trained engineers to provide a reliable support and after-sales service. CALL CENTRE dedicated for connection to the G-TEC Service organisation. G-TEC Service personnel are always available and ready to provide advice and assistance regarding UPS installation, maintenance, fault finding and repair. G-TEC Service can provide assistance during commissioning and startup of the UPS equipment on-site with additional training during handover to site personnel. MAINTENANCE CONTRTS can be provided by G-TEC Service to minimise response times and repair costs. Contracts range from periodic inspections to comprehensive cover including labour and materials. FAST & READY: a fast repair on site is guaranteed through the use of state-ofthe-art UPS technology, the professionalism of the UPService personnel and Authorised Assistance Centres. UPService guarantees that failed parts are replaced with original ones, tested and updated in order to maintain the safety, reliability and operating characteristics of the UPS. www.gtec-power.eu G-Tec Europe srl Strada Marosticana, 81/13 36031 Povolaro (VI), Italia Tel. +39 0444.361321 - Fax +39 0444.365191 info@gtec-power.eu G-Tec Asia Pacific Pte Ltd 60 Kaki Bukit Place, #02-05, Eunos Techpark II, Singapore 415979 Tel. +65 6555.5014 - Fax +65 6555.4105 info@gtec.com.sg