Similar documents

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors


Digital Keypad Use s Manual

TS93 EMR T/PT/TDE. Surface applied door closer

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

OPL BASIC. Dosing System for Professional Laundry machines. Contents

ABLOY EL420, EL520 Europrofile motor locks

ED 100LE ED 250LE. Low energy swing door operators

WD-AMX Water Detection Controllers

HM-W536 Install Guide

Manual for Fire Suppression & Methane Detection System

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

ViZion Installation Guide

ACS-30-EU-EMDR-10-MOD

AUTODIALLER / QUICKDIALLER - SA132

Drayton Digistat +2RF/+3RF

Technical Overview Add-on Sensors - Smoke Alarm. Get yours direct at:

EC DECLARATION OF CONFORMITY FOR MACHINES

CB200W Water Leak Detection Panel Application Guide

CONTENTS. 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag DESCRIPTION pag TECHNICAL SPECIFICATIONS pag INSTALLATION pag.

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

ABLOY DC 240 DOOR CLOSER Heavy duty door closer

Wespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE

TS510 & TS500. Installation & User Guide. Compatible Equipment

SECURITY SYSTEM ADP-CAN

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

TMS TANK MANAGEMENT SYSTEM

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Product and functional description

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

Power Window/Power Lock Installation. To begin with you will need all the parts listed below:

TrueAlarm Fire Alarm Systems

Advantium 2 Plus Alarm

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Know-how makes the difference. Electrical Actuators

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Modular I/O System Analog and Digital Interface Modules

AD425S Automatic door operator

Passive Infrared Motion Detector 5420/90. Installation Instructions

Leak Detection System

WIRELESS HOME ALARM SYSTEM (WHA1)

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Water Leak Detection System

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

i ChatterBox! Motorcycle Security

Operating Instructions

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

Contractors Guide Central Inverter System Installation

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

DC-8706K Auto Dial Alarm System

FIREDEX Conventional Fire Panels

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Telefon (+45) Telefax (+45) Installation and operating manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Model 201 Wiegand Touchpad Reader Installation Guide

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR

COLOR VIDEO DOOR PHONE CDV-71BE/D

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

TECHNICAL INFORMATION

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

User s Manual Before using the inverter, you need to read and save the safety instructions.

Luna/200. Luna/275. Ceiling hoist. User instruction. Important - warning. This manual must be read before the Luna is used

INSTALLATION AND OPERATION MANUAL

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

SECTION DETECTION AND ALARM

EMF/EMR. Holder/Release Devices with Integral Door Closers

TIG INVERTER INSTRUCTION MANUAL

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

DALI RC BASIC SO. Control unit Operating instructions

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Combi B Alarm box. Mounting instructions

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

site monitoring Kit Site Monitoring Kit User Manual we prove it.

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

ABLOY EL460, EL461, EL560, EL561 Europrofile handle controlled locks

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

2013 Wireless Video Intercom INSTALLATION GUIDE

ABB i-bus KNX Security Terminals MT/U , MT/S M and M Product Manual

Servo Info and Centering

INSTALLER S & OWNER S MANUAL

Transcription:

ABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company

APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive 89/6/EEC Statement of fire doors by Technical Research Centre of Finland Warning! Warning! ------------------- THIS MANUAL CONTAINS IMPORTANT SAFETY INSTRUCTIONS ------------------- Warning - IT IS IMPORTANT FOR SAFETY OF PERSONS TO FOLLOW THESE INSTRUCTIONS. -------------------------------------------- SAVE THESE INSTRUCTIONS -------------------------------------------- Do not allow children to play with fixed controls. Frequently examine the installation for imbalance and signs of wear or damage to cables, springs and mountings. Do not use if repair or adjustment is necessary. Disconnect the supply when cleaning or other maintenance is being carried out. Before installing the operator, check that the door is in good mechanical condition and it opens and closes properly. Ensure that entrapment between door and the surroundings is avoided. Ensure that the operator is suited for installation. Check temperature, humidity, door weights, etc. restriction, what is mentioned in this manual or other Abloy Oy material. Note! Instructions, design specifications and illustrations which are contained in this manual are not binding. Rights reserved for changes without previous notice.

CONTENTS Approvals... Revision... Content of delivery... General information...6 Operation... 7 Main switch and mode switch...7 Door weight...8 Installation...9 Internal connections... Commissioning... A safe door... 8 External connections... 9 Connection examples... Self diagnostic...8 Maintenance... 9 Spare parts...0

REVISION Following pages has been revised: Page Revision As at..006.

CONTENT OF DELIVERY DA60 Swing door operator - screws pcs M8x DA0 Mounting plate - screws 6 pcs,x DA7 Standard arm - screws pcs,x and pcs M8x0 DA8 Extended arm - screws pcs,x and pcs M8x0 DA9 Sliding arm - screws pcs,x0 and pcs M8x0 DA0 Extension piece - 0 mm + M8x - 0 mm + M8x + M8x - 60 mm + M8x90

GENERAL INFORMATION Technical data Measures 9 (L) x 8 (H) x 07 (W) mm Weight 6, kg Supply voltage 90-6 VAC, 7-6 Hz Rated output 70 W Enclosure class IP0 Temperature range Storage -0...+8 C (in dry premises) Operation: -...+0 C (in dry premises) The automatic swing door operator must not be installed in applications where it is subjected to water or snow. Interfaces Voltage output VDC, stabilized, output current 00 ma Voltage output VDC, stabilized, output current,0 A The total load must not exceed W Potential free relay output, preset to operate seconds A @ 0 VDC resistive load Features Usage for heavy density of pedestrian traffic Push&Go as a standard feature Normal and delayed Adjustable hold open time 0...60 s or sequential use Fire detector connection Free Swing operation Door hold force Prepull before opening Secondary DC inlet for power back up ( VDC (± %), A) Maximum opening angles: With standard arm 00 degrees With sliding arm on the opening side 00 degrees With sliding arm on the closing side 90 degrees 6

OPERATION Abloy DA60 is an electromechanical swing door operator for heavy use. The door operator includes new free swing function: when using the door manually it operates lightly without motor s resistance and the door can be left in open position when required. It can be used on both single and double, internal and external, fire and emergency exit doors. Safety features Opening cycle: If the door is obstructed in opening cycle. The door is set free and hold open time is started. After second, new trial is done to open the door. Maximum amount for trials is. If this is exceeded or hold open time is end, the door is closed. Closing cycle: If the door is obstructed in closing cycle. The door is set free and new trials are done to close the door. If the closing is still obstructed, the operator tries to close the door at one minute intervals. MAIN SWITCH AND MODE SWITCH AUTO MAN OPEN Main switch Mode switch When the power is switched on, the mains switch lights up. = on 0= off Functions of mode switch AUTO: The operator opens the door for the duration of the hold open time. MAN: Manual use. OPEN: The door is held permanetly open. NOTE! There is seconds constant delay when mode switch is changed from position OPEN to AUTO or MAN. 7

DOOR WEIGHT Standard arm Door weight [kg] 80 70 60 0 0 0 0 0 00 90 80 70 60 0 60 70 80 90 00 0 0 0 0 0 Door width [cm] Sliding arm Door weight [kg] 80 70 60 0 0 0 0 0 00 90 80 70 60 0 60 70 80 90 00 0 0 0 0 0 Door width [cm] 8

INSTALLATION Tools required Drill Set of ball ended allen wrenches # Phillips head screwdriver Flat blade screwdrivers, pcs Steps of installation - Preparing installation - Installing the mounting plate - Mounting the operator and the arm - Connecting the operator to mains - Commissioning - Testing - Connecting devices Preparing installation - Check the proper function of the door - hinges - door clearance - Check the proper function of the lock - lock case - striker plate Removal of housing Note! Remove the protective earth wire from cover and connect it back after installation. Keep the mains disconnected when removing or mounting cover. 9

Installing the mounting plate Operator is to be installed on the transom, with the main switch located towards the hinge. Use the mounting plate DA0 with the door operator ensuring the installation base is level and securely fixed to a flat surface. Hinge line 9, 6 96, 0 9 o 0 0 o 0 o 0 o 0 8, 8, 70 8, Installation measurements for standard arm and for sliding arm DA9 to the closing side installation. When installing operator to the opening side of the door, refer to page. 0

Assembly of the operator and the standard arm to the closing side Hinge line Mounting of the operator M8x and washer 97 70 Min. 0 Y Y (mm) Length of extension piece 0 No extension piece 0 0 mm (DA0/0) 0 0 mm (DA0/0) 0 0 mm (DA0/0, DA0/0) 0 0 mm (DA0/0 * pcs) 60 60 mm (DA0/06) 90 Frame depth DA7 DA8 Frame depth 0-0 mm 0-0 mm - After installation, ensure that the arm and door are properly adjusted. - Mount a door stop to the door open position so that wind will not drive the door against the wall, resulting in damage. - Tighten the holding screw.

Assembly of the operator and the sliding arm DA9 to the closing side Hinge line Mounting of the operator M8x and washer * From the mounting plate to the mounting hole of the sliding rail, without extension piece. Y L 6* 97 M Y (mm) Length of extension piece 0 0 mm (DA0/0) 0 0 mm (DA0/0) 0 0 mm (DA0/0, DA0/0) 0 0 mm (DA0/0 pcs) 0 60 mm (DA0/06) DA9 Frame depth Frame depth H/mm 0 0 0-00 00-0 Arm distance L/mm 9 0 0 77 Minimum door width M/mm 760 760 760 760 - After installation, ensure that the arm and door are properly adjusted. - Mount a door stop to the door open position so that wind will not drive the door against the wall, resulting in damage. - Tighten the holding screw.

Assembly of the operator and the sliding arm DA9 to the opening side Mounting of the operator M8x and washer Hinge line max. M LY Y (mm) Length of extension piece 0 No extension piece 0 0 mm (DA0/0) 0 0 mm (DA0/0) 0 0 mm (DA0/0, DA0/0) 60 0 mm (DA0/0 * pcs) 80 60 mm (DA0/06) DA9 Frame depth Frame depth H/mm Arm distance L/mm Minimum door width M/mm 0 0-0 0-00 00-0 80 60 0 70 79 80 87 - After installation, ensure that the arm and door are properly adjusted. - Mount a door stop to the door open position so that wind will not drive the door against the wall, resulting in damage. - Tighten the holding screw.

INTERNAL CONNECTIONS - Electrical connections should be made by a qualified electrician. - The power plug must have an easy access. - If a permanent connection is made unit must be equipped with an external switch providing all pole disconnection. - Keep the mains disconnected during installation. External power supply unit +VDC, min A X X black To motor red + V backup + V in black white X X6 DC X Option interface white brown AC PE AUTO: red & black MAN: NC OPEN: blue & black Position sensor blue black red Mode switch AUTO MAN OPEN I 0 Main switch white brown brown white N L DC supply back-up When not mains operated, or for back-up supply, the external VDC (min. A) supply can be connected to X connectors and. Connect + from DC supply back-up to X connector and to X connector. No battery charging or maintenance is provided by DA60.

COMMISSIONING Check the free movement of the door. Turn mode switch to MAN. The mode switch is located in the head panel. Plug in the mains and turn main switch on. The main switch is located in the head panel. Choose the type of the arm Main switch Mode switch standard sliding ARM The jumpers are located on the control board. Jumper is connected Jumper is disconnected Check the DOOR sealed hold closed Push&Go DOOR "Sealed" enables motorized closing pull before opening and final pull when closing. Select this to ensure the proper function of the lock when prepull and final pull are needed. Final pull will be activated 0-0 mm before the doors closed position. Final pull is activated second, when door is closed position. sealed hold closed Push&Go When hold closed jumper is selected, operator pushes the door against the frame. DOOR sealed hold closed Push&Go DOOR Push&Go is in operation, when mode switch is in AUTO position. When door is pushed or pulled manually operator opens the door. Operator opens the door to adjusted opening angle and closes the door after second hold open time. Note! It is not possble to use Push&Go and free swing options at the same time.

COMMISSIONING 6 Check the OPTION single master corridor fire n.c free swing Select "single" for a stand alone door. "Master" and "Corridor", not yet available. OPTION single master corridor fire n.c free swing OPTION single master corridor fire n.c free swing OPTION If the jumper is connected then operator requires N.C. output from the fire detector. If the jumper is disconnected then operator requires N.O. output from the fire detector. When jumper is connected the door can opened and closed manually. When opening comes, the door is opened to fully open position and closed after adjusted hold open time. Free swing is in operation when mode switch is in AUTO position. Note! It is not possble to use Push&Go and free swing options at the same time. 7 Teach door open and closed position TEACH CLOSED TEACH OPEN POWER ON TEACH - Push TEACH-button to enter learning mode. - Teach the door closed position Yellow led blinks: close the door and push TEACH-button. - Teach the door open position Green led blinks: Open the door to the desired angle and push TEACH-button. - Yellow "TEACH CLOSED" led blinks: Close the door manually. 8 Operators force, opening speed and hold open time Force FORCE The operator's force requires adjustment to suit door weight. Use lowest possible value to ensure the smooth function of safety feature. Start the adjustment by putting the force potentiometer to middle position (= 0%) and fine-tune it after opening speed adjustment. Note! Important: as less force as possible 6

COMMISSIONING Adjust the opening speed. min max SPEED Time (sec) Door width (mm) Door weight (kg) 60 80 00 0 800,7,,,9 000,,0,,8 00,,7,,8 00,,,8 6, Minimum safe opening and closing times for door of various widths and weights are summarized in the table. Hold open times Adjust first hold open time for delayed and then hold open time for normal 0 HOLD OPEN seq 60 Adjusting the hold open time for delayed Entering the mode: - Turn mode switch to AUTO position. - Press TEACH button at least seconds. - In the programming mode green led is lit, yellow led is flashing times, pause, times, pause... - Adjust the hold open time for delayed (0...60 sec). Time starts when the door is in open position. Full right position (seq) of the potentiometer means that every other either opens or closes the door. Back to normal mode: - Press TEACH button at least seconds or wait minutes. - Turn mode switch to MAN position. 0 HOLD OPEN seq 60 Adjusting hold open time for normal - Adjust the hold open time (0...60 s). Time starts when the door is in open position. Full right position (seq) of the potentiometer means that every other either opens or closes the door. Note! For safe operation, always use low force, speed and long hold open time. 9 Test the operation - Turn mode switch to AUTO. - Test the operation. - If the function is not desired, repeat steps to 9. 7

A SAFE DOOR The safety of the door operator is controlled by basic adjustments; operator force, speeds, and hold open times. - The operator force is an important adjustment. A high value affects to the safety feature and also to its sensitivity. - High speeds increases the energy transferred in the door causing it not stop correctly. - With hold open times the distance from device to door is preset.. Adjust low speeds.. Adjust the operator force to a low setting ensuring the safety feature activates on door moving.. Adjust the hold open times. By following these basic procedures the operator is safe in operation. Note!!! High speeds and safety is only possible by fitting of Safety sensors. A safe door environment needs ALWAYS a safety sensor. It is recommended to use safety sensor when possible, not only with high speeds. 8

EXTERNAL CONNECTIONS +V out +V out 6 7 8 9 0 Normal Delayed Safet senso Lockin circui Fire detector y r g t + VDC, 00 ma output + VDC,,0 A output 0 Ground 7, 8, 9 Potential free relay output for lock drive 6 Normal Delayed. Door will open after,0 seconds delay. Safety sensor Ground to stop the door movement during operation Locking circuit Inhibits the opening if the lock bolt is out. Grounding this input allows the opening Fire detector Ground Note! The total load must not exceed W Fire detector Take connection loop between and away if fire detector is connected. Connect fire detector between and and check fire jumper (fire n.c.). After fire alarm, one manual opening is required to re-energise the operator to chosen program selector mode. Safety Sensor On the opening side of the door: Safety sensor is connected between terminals and. The cable loop must have KOhm resistance inside the safety sensor for cable break detection. Leave resistor connected to the terminals and, when safety sensor is not used. Always use safety sensor for maximum safety. On the closing side of the door: Safety sensor is connected to input. - Do not strip any cables for unnecessary length. Loose wires may cause unwanted contacts. 9

EXTERNAL CONNECTIONS Impulse inputs The closing contact drive (NO) must be potential free. The device, like a push button or motion sensor, must be installed within direct sight of the door. Maximum length of the device cable is 0 meters. The total resistance of the control switch and its wiring must not exceed 00 ohm, when switch is closed. Delayed : delay =,0 seconds. When the operator receives the opening, the lock is released immediately and door is opened after,0 seconds. Normal : Door is opened immediately. - Do not strip any cables for unnecessary length. Loose wires may cause unwanted contacts. 0

CONNECTION EXAMPLES Safety sensors DA00 and DA00 On the opening side + out +V out 0 9 8 7 6 000 ohm 8 7 Normal Delayed Safety sensor Locking circuit Fire detector 6 Connect the 000 ohm resistor from connectors and to safety sensor connectors and 6. The resistor connection controls the condition of cable. If cable is cut or short circuit, the door will stop. When sensor detects an obstacle, the operator stops the door. On the closing side + out +V out 0 8 7 6 9 8 7 Normal Delayed Safety sensor Locking circuit Fire detector 6 When sensor detects an obstacle, the operator opens the door for duration of the hold open time. LIGHT ON LIGHT ON (LO) Jumper settings and connection block for DA00 and DA00 6 7 8

CONNECTION EXAMPLES DA06 and DA06 Microwave motion sensor + out +V out green brown yellow white 0 9 8 7 6 Normal Delayed Safety sensor Locking circuit Fire detector DA06 Microwave motion sensor + out +V out 0 green brown 9 8 yellow blue 7 Normal Delayed 6 pink white Safety sensor Locking circuit Fire detector

CONNECTION EXAMPLES DA0 Elbow switch + out +V out 0 9 8 7 6 Normal Delayed N.C N.O COM Safety sensor Locking circuit Fire detector DA09 and DA09 rotary switch X red X blue black MANUAL = no connection AUTO =... OPEN =...

CONNECTION EXAMPLES Electric locks EL, EL, EL red + out +V out 0 9 green 8 7 6 Normal Delayed blue Safety sensor Locking circuit black Fire detector Motor locks EL90, EL90 red + out white 0 +V out 9 green 8 7 6 Normal Delayed blue Safety sensor Locking circuit grey Fire detector

CONTROLS CONNECTION EXAMPLES Motorlocks EL0, EL0 + out Extension cable ABLOY EA8, EL9 EA8 Length 6m/0m Cable 6 x 0. mm^ +V 9 0 6 7 8 9 0 S/N: -VDC -8VAC BACKUP+ BACKUP - AC /DC AC /DC OPEN NO WHITE BLACK+VIOL. DOOR C CLOSED NC GREEN USED NO 6 YELLOW RED HANDLE C NOT USED NC 7 8 BROWN USED NO 9 BLUE RED/GREEN CYLINDER C NOT USED NC 0 ORANGE NO BOLT IN TURQUOISE C GREY NC BOLT OUT PINK C OPENING 6 DELAY SWITCH TIME s RESERVED 7 s s s 8 6s Example s. 8s s s 0 0 0 0 0 EA0 0 0 0 0 0 0 0 0 POWER 0 9 8 7 6 +V out Normal Delayed Safety sensor Locking circuit Fire detector EL0 consumes max. 600mA current. Electric lock EL0 red + out +V out 0 9 green 8 7 6 Normal Delayed blue Safety sensor Locking circuit black Fire detector

CONNECTION EXAMPLES Rebated doors Impulse device ACTIVE DOOR + out +V out 0 9 8 7 6 Normal Delayed Safety sensor Locking circuit Fire detector PASSIVE DOOR + out +V out 0 9 8 7 6 Normal Delayed Passive door opens after constant delay,0 seconds. Adjust the hold open time for passive door - seconds shorter than active door. Safety sensor Locking circuit Fire detector 6 Note! Mechanical coordinator ensures that double doors close correctly!

CONNECTION EXAMPLES Fire door system red + out white 0 +V out 9 green 8 7 6 Normal Delayed EL90 Motor lock blue grey Safet sensor Locking circuit Fire detector y LED NC C NO LED NC C NO OPERATION: When detector reacts, it s relay switches on. Then the (-) is disconnected from the operator s control unit (connector ). The operator doesn t open the door from but it have to be opened manually. The operator closes the door after manual opening. In fire door use the operator have to be connected to external battery backup (VDC, min. A). In case of fire -> the door closes After fire alarm, one manual opening is required to re-energise the operator to chosen program selector mode. 7

SELF DIAGNOSTICS The means of diagnostic features is to - detect malfunctions - try to take care of safety during malfunction - get the operator to recover from the defected state. In case the result of the diagnostics shows unrecoverable malfunctions, the door operator is considered as unsafe, and the door is set free for manual use. The user is informed by blinking both of the LED s in control unit. Control units LED s TEACH CLOSED TEACH OPEN POWER ON TEACH Yellow led = Y Green led = G Indication Possible Fault Corrective user interventions in defined order G not lit Y not lit No power. Faulty power supply unit. Faulty control board. ) Check the mains. ) Remove pin connector from the control board. ) Measure the voltage from pin connector, connection points and. If voltage is under VDC, change the power supply unit. ) Measure the voltage from pin connector, +V out against. If voltage is not VDC, change the control board. G lit Y lit The door close and open positions are not successfully teached. Impulse device is active all the time. Fire detector is active. ) Teach the door open and close positions. ) Check all devices and connections. ) Check fire detector connection and fire N.C. jumper. G lit Y flash Flash short...short...short...: 000 ohm resistor is missing or cable of safety sensor is cut. ) Check that 000 ohm resistor is connected in control board or in safety sensor. ) Check that cables are not damaged. Flash short...long...short...long...: Safety sensor is active or cable of safety sensor is short-circuited. ) Move obstacle from safety sensor detection area. ) Check that cables are not damaged. G flash Y flash Internal fault in the control board. Door motion is stopped. ) Switch main switch off for 0 seconds. ) Check that all applicable jumpers are in place (one of the two arms is selected, single is selected). ) Teach the door open and close positions. ) Change a spare control board. 8 G flash Y flash alternates Internal fault in the position sensor board. Door motion is stopped. ) Switch main switch off for 0 seconds. ) Check that all applicable jumpers are in place (one of the two arms is selected, single is selected) Check position sensor s cable and connector. ) Teach the door positions. ) Change a spare position sensor.

MAINTENANCE Requirements for trouble-free use of the operator Installation, commissioning and maintenance is made by trained and qualified technician. Door leaf is moving sensitively and locking works well. Regular annual services are made: - Under 00 openings per day; service once a year - 00... 00 openings per day; service two times a year - Over 00 openings per day; service... times a year Inspections made in the service: - Greasing of the bevel gears - Fixing of the operator and arm - Function and adjustments of and safety devices - Programming and adjustments of the operator 9

DA60 SPARE PARTS Head panel 807 Compatible unit 8098 Position sensor 80986 Control unit 809877 Mode switch 80998 Rear damper 80980 Side damper 800 Transformer 8007 Main switch 8077 DA7 DA8 DA9 Cover aluminium 08 Cover white 07 0

Some of the materials in this product, such as electronic components, require specialist recycling techniques. Nimike Päiväys 968 /006 PRODUCT MANAGEMENT DOOR AUTOMATICS/..006/FH www.abloy.com Abloy Oy Wahlforssinkatu 0 P.O. Box 08 FIN-8080 JOENSUU FINLAND Tel. +8 0 99 0 Fax +8 0 99 09 ISO 900 ISO 00 CERTIFIED ORGANISATION An ASSA ABLOY Group company ABLOY Oy is one of the leading manufacturers of locks, locking systems and architectural hardware and the world s leading developer of products in the field of electromechanical locking technology. The ASSA ABLOY Group is the world s leading manufacturer and supplier of locking solutions, dedicated to satisfying end-user needs for security, safety and convenience.