Magneto-optical microscopy (incl. time-resolved)

Similar documents
Ultrasonic Wave Propagation Review

Magneto-Optic Kerr Eect Microscopy

High Frequency Behaviour of Magnetic Thin Film Elements for. Microelectronics

Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications

X-Rays and Magnetism From Fundamentals to Nanoscale Dynamics

Imaging of Spin Dynamics in Closure Domain and Vortex Structures. J. P. Park, P. Eames, D. M. Engebretson, J. Berezovsky, and P. A.

Various Technics of Liquids and Solids Level Measurements. (Part 3)

Near-field scanning optical microscopy (SNOM)

- particle with kinetic energy E strikes a barrier with height U 0 > E and width L. - classically the particle cannot overcome the barrier

Modern Classical Optics

Measuring index of refraction

E190Q Lecture 5 Autonomous Robot Navigation

DESIGN AND EVALUATION OF PROBE WITH THREE DEGREE- OF-FREEDOM FOR NON-DESTRUCTIVE TEST USING THREE- DIMENSIONAL FINITE ELEMENT METHOD

Polarization of Light

The Basics of Scanning Electron Microscopy

Acoustic GHz-Microscopy: Potential, Challenges and Applications

Acousto-optic modulator

A wave lab inside a coaxial cable

Atomic Force Microscopy Observation and Characterization of a CD Stamper, Lycopodium Spores, and Step-Height Standard Diffraction Grating

SEMIAUTOMATIC SURFACE REFLECTANCE MEASUREMENT FOR MONITORING OF MATERIAL WEATHERING

5. Scanning Near-Field Optical Microscopy 5.1. Resolution of conventional optical microscopy

Encoders for Linear Motors in the Electronics Industry

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

Using light scattering method to find The surface tension of water

Optical Metrology. Third Edition. Kjell J. Gasvik Spectra Vision AS, Trondheim, Norway JOHN WILEY & SONS, LTD

Automotive Applications of 3D Laser Scanning Introduction

Longwave IR focal-plane binary optics

Lecture 4 Scanning Probe Microscopy (SPM)

CREOL, College of Optics & Photonics, University of Central Florida

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Robot Perception Continued

Phased-Array ROWA-SPA: High-performance testing machine for combined, 100-percent automated testing of square and round bars

Femtosecond laser-induced silicon surface morphology in water confinement

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

ENGINEERING METROLOGY

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters

Experiment 5. Lasers and laser mode structure

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.

Application Note AN1

1 Introduction. 1.1 Historical Perspective

DETECTION OF SUBSURFACE DAMAGE IN OPTICAL TRANSPARENT MATERIALSS USING SHORT COHERENCE TOMOGRAPHY. Rainer Boerret, Dominik Wiedemann, Andreas Kelm

Magnetic Media Measurements with a VSM

Synthetic Sensing: Proximity / Distance Sensors

FTIR Instrumentation

A METHOD OF PRECISE CALIBRATION FOR PIEZOELECTRICAL ACTUATORS

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

Physics 441/2: Transmission Electron Microscope

v = fλ PROGRESSIVE WAVES 1 Candidates should be able to :

PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany

Diffraction and Young s Single Slit Experiment

Lenses and Apertures of A TEM

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)

The Olympus stereology system. The Computer Assisted Stereological Toolbox

It has long been a goal to achieve higher spatial resolution in optical imaging and

Non-Contact Vibration Measurement of Micro-Structures

Determination of source parameters from seismic spectra

NON-DESTRUCTIVE METHODS. CE 165: Concrete Materials and Concrete Construction

Physics 9e/Cutnell. correlated to the. College Board AP Physics 1 Course Objectives

Confocal Microscopy and Atomic Force Microscopy (AFM) A very brief primer...

PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. IV Femtosecond Measurements Combined With Near-Field Optical Microscopy - Artyom A.

Coating Technology: Evaporation Vs Sputtering

Introduction to Optics

AP1 Waves. (A) frequency (B) wavelength (C) speed (D) intensity. Answer: (A) and (D) frequency and intensity.

S. Hartmann, C. Seiler, R. Dörner and P. Grimm

Scanning Near-Field Optical Microscopy for Measuring Materials Properties at the Nanoscale

Laser-induced surface phonons and their excitation of nanostructures

A Guide to Acousto-Optic Modulators

Automatic and Objective Measurement of Residual Stress and Cord in Glass

UNIT I: INTRFERENCE & DIFFRACTION Div. B Div. D Div. F INTRFERENCE

Optical Storage Technology. Optical Disc Storage

Lecture 14. Point Spread Function (PSF)

Scanning Acoustic Microscopy Training

A PHOTOGRAMMETRIC APPRAOCH FOR AUTOMATIC TRAFFIC ASSESSMENT USING CONVENTIONAL CCTV CAMERA

The promise of ultrasonic phased arrays and the role of modeling in specifying systems

Components for Infrared Spectroscopy. Dispersive IR Spectroscopy

8.2 Elastic Strain Energy

COMP175: Computer Graphics. Lecture 1 Introduction and Display Technologies

AP1 Oscillations. 1. Which of the following statements about a spring-block oscillator in simple harmonic motion about its equilibrium point is false?

Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ.

New Approach to Analysis of the Switching Current Data in Ferroelectric Thin Films

SPM 150 Aarhus with KolibriSensor

NEAR FIELD OPTICAL MICROSCOPY AND SPECTROSCOPY WITH STM AND AFM PROBES

X-Ray Study of Soft and Hard Magnetic Thin Films

Application of Nuclear Magnetic Resonance in Petroleum Exploration

Calibration of AFM with virtual standards; robust, versatile and accurate. Richard Koops VSL Dutch Metrology Institute Delft

Anomalous Hall Effect Magnetometry A Method for Studying Magnetic Processes of Thin Magnetic Films

Fluid structure interaction of a vibrating circular plate in a bounded fluid volume: simulation and experiment

Experiment 3 Lenses and Images

Experimental results for the focal waveform and beam width in the focusing lens with a 100 ps filter

Measurement of Resistive Wall Mode Stability in Rotating High Beta Plasmas

LAB 7 MOSFET CHARACTERISTICS AND APPLICATIONS

OPTICAL FIBERS INTRODUCTION

Lab 9: The Acousto-Optic Effect

AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

Interferometers. OBJECTIVES To examine the operation of several kinds of interferometers. d sin = n (1)

A More Efficient Way to De-shelve 137 Ba +

Transcription:

Magneto-optical microscopy (incl. time-resolved) J. McCord (abstract in cooperation with R. Schäfer) IFW Dresden - Institute for Metallic Materials Helmholtzstr. 20 01169 Dresden j.mccord@ifw-dresden.de 1. Introduction Important for the understanding of the origin of magnetic properties and technological application of magnetic materials is the ability to observe the magnetic domain structure. One method, practiced since decades, is magneto-optical microscopy using conventional imaging optics. Magneto-optical microscopy is one of the most versatile techniques to image magnetic domains and magnetization processes. The method is based on the magneto-optical Faraday or Kerr effect, i.e. the rotation of linearly polarized light in dependence of the magnetization direction on transmission or reflection from a non-transparent sample, respectively. In this presentation the principles of magneto-optical microscopy, mostly Kerr microscopy and magnetic imaging based on magneto-optical indicator films, will be reviewed. A special emphasis will be on time-resolved imaging techniques. 2. Fundamentals of magneto-optical microscopy The interaction of a plane-polarized electromagnetic light wave with a magnetic material can be illustrated in an image based on the effect of the Lorentz force on the electrons set in motion by the electrical vector E of the wave. This influence is represented in Fig. 1 for the longitudinal Kerr effect. The Lorentz movement generates a magnetic contribution to the reflected light amplitude, the so-called Kerr amplitude K, which is polarized perpendicularly to the normally reflected amplitude N and causes rotation of the light through interference with N. In the simplest case, for domains with opposite magnetization, a maximum domain contrast is produced if e.g. an analyzer blocks most of the reflected light of one domain type. The domain contrast in the image is directly sensitive to the magnitude and direction of magnetization. Additional magneto-optic effects will be discussed. Fig. 1 (a) Illustration of the longitudinal Kerr effect (taken from [1]) Magneto-optical microscopy (incl. time-resolved) III.1-1 J. McCord

Arbitrary magnetic fields can be applied during observation so that domain nucleation and magnetization processes can be observed easily. Possibly the utmost advantage over other domain observation methods is the speed and time-resolution in which images can be acquired. A magneto-optical microscope is essentially a polarization microscope, with which maximum lateral resolution of around 300 nm can be achieved using oil immersion objectives with a high numerical aperture. The main components of a wide-field microscope are represented schematically in Fig. 2. As the magneto-optical contrast is rather weak, a highly intensive light source is used, usually a high-pressure xenon or mercury lamp. Lasers can be used for wide-field illumination in principle, but some effort is required to obtain the necessary incoherent light source from the coherent laser light. For scanning microscopy, the use of low noise lasers is used on regular basis. As the magneto-optical contrast might be very weak, significant enhancement is possible by video microscopy and digital image processing in the case of wide-field microscopy. A possible background image subtraction process is best carried out in real time at video frequency, making it possible to view magnetization processes in real-time. For laser based scanning microscopes, usually lock-in techniques are used for contrast enhancement and reduction of signal-to-noise ratio. Fig. 3 (a) Schematic representation of the main components of a Kerr microscope. The inset shows the beam path of an optical reflected light microscope. The aperture iris is displaced from the optical axis to generate oblique incidence of light (adapted from [1]). 3. Practical Aspects The optical technique has many advantages. The magnetization can be observed directly without ambiguity. The samples are not destroyed or damaged during observation and the process of observation does not influence the magnetization. The shape and size of the sample are largely arbitrary. Imaging through transparent or semi-transparent covering layers can be achieved. Free sample manipulation is easily possible during observation. High or low tem- Magneto-optical microscopy (incl. time-resolved) III.1-2 J. McCord

perature, mechanical stress or, most importantly, arbitrary magnetic fields may be applied, allowing to study magnetization processes easily. The same effects that are used for imaging may also be used for the magnetic characterization of the material, i.e. local hysteresis curves may be obtained by just plotting the average intensity of the Kerr images as a function of applied field. Examples for all of the above will be presented. Due to its linearity and direct sensitivity to the magnetization vector m, the Kerr effect can be used for a quantitative determination of the magnetization direction [2]. However, besides these advantages there are also a number of obstacles. Often samples have to be prepared so that they are reasonably flat and smooth on a scale exceeding the chosen lateral resolution. The resolution is limited to magnetic domains larger than about 0.2 µm, corresponding to an optical resolution of about 0.3 µm. On metals, only the surface magnetization in a layer of the penetration depth of some 10 nm can be seen. In bulk samples it restricts the possibilities of domain studies to surface domains (which in most cases are different from underlying volume domains). For thin film studies this is not necessarily a disadvantage. Using a rotatable compensator, the phase of the Kerr amplitude, generated in a certain depth, can be adjusted relative to the regularly reflected light amplitude. In this way light from selected depth zones can be made invisible if their Kerr amplitude is adjusted out of phase with respect to the regular light, layer-selective magneto-optical microscopy is possible then. 4. Time-resolved imaging Time-resolved observation of periodic magnetization processes is e.g. possible by stroboscopic imaging, using either by a triggered video camera or a pulsed light source [2]. This can be done by laser scanning techniques or by wide-field techniques. Triggering the light or camera pulses with precise timing relative to a field pulse and sweeping the delay time of probing yields a series of corresponding pictures of periodic or quasi-periodic processes. An experimental setup of such a stroboscope, as we recently installed it at IFW-Dresden, is shown in Fig. 4. Fig. 4 Schematics of an experiment for stroboscopic domain imaging, implemented in a regular wide-field Kerr microscope. The time resolution is obtained by illumination with a pulsed laser. The laser-based stroboscope allows a time resolution of below 20 ps. Magneto-optical microscopy (incl. time-resolved) III.1-3 J. McCord

As the Kerr signals on small time scales are usually too weak to obtain single-shot images (depends also on chosen time-resolution), an averaging over a number of images at each time delay is necessary to obtain reasonable contrast. Prerequisite is that the fast magnetization processes are reproducible. The use of wide-field Kerr microscopy for dynamic imaging has the advantage, that also the domain ground states and quasi-static processes (i.e. in slowly changing fields) can be studied for comparison. One simple example is discussed here. The magnetization processes initiated by highfrequency fields or by field pulses are very different from those in slowly varying fields. As the switching, e.g. of a soft magnetic film element, in pulsed fields occurs in the nanosecond regime, one has to consider that the magnetization (or the domains) will not be able to instantaneously follow the magnetic field. To reach the new magnetization direction, it will have to spin about the field axis, a process called precessional motion that is gradually opposed by damping. Therefore remagnetization processes in pulsed fields may not be seen as a simple switch of magnetization direction. An example of such an experiment on a Permalloy film element is shown in Fig. 5. Fig. 5 Magnetization process of a Permalloy square element of 50 nm thickness, initiated by a diagonal, lowamplitude field pulse around the Landau ground state. In a slowly varying field (bottom row) the center vortex is shifted reversibly around its equilibrium position. In a pulsed field (upper three rows of images) the domain walls and the vortex cannot follow the field pulse. Rather rotational processes occur, until the walls are restored after about 5 ns. 5. Conclusions Magneto-optical microscopy is a versatile method for the experimental analysis of magnetic microstructures, only limited by resolution down to a few tenths of a micrometer. The dynamic capability and the compatibility with arbitrary applied fields make Kerr microscopy Magneto-optical microscopy (incl. time-resolved) III.1-4 J. McCord

ideally suited for the investigation of fast and slow magnetization processes. Due to the direct sensitivity and linear dependence on the magnetic polarization, the method allows the quantitative determination of magnetization vector fields at the surface of soft magnets. Bibliography (Reviews) [1] A. Hubert and R. Schäfer: Magnetic Domains. The Analysis of Magnetic Microstructures. Springer Verlag, Berlin (1998) [2] M. Freeman and W. K. Hiebert, in Spin Dynamics in Confined Magnetic Structures I, ed. by B. Hillebrands and K. Ounadjela, Springer Berlin (2002) Magneto-optical microscopy (incl. time-resolved) III.1-5 J. McCord