E.1.12: GROUNDING SYSTEM

Similar documents
TABLE OF CONTENT

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

STREETLIGHT SYSTEM GROUNDING AND BONDING

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

Network Standard Advice No. 1420C 9/6/2011

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

GUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS (440)

EARTHING SYSTEM CALCULATION

FLEXIBLE COPPER & ALUMINIUM CONNECTIONS. Product Range 1 VGL - ALLIED CONNECTORS

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

SAES-P January, 2004 Grounding. Electrical Systems Designs & Automation Standards Committee Members

Hyperlinks are Inactive

UGVCL/SP/591/11KV HT AB CABLE

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

KNOW YOUR OPTIONS: 230 KV POWER CABLES

Cables, Cable Laying & Accessories Manual

Communication, Signal & Data Cables

Section kv Power Cables

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Fault location on power cables. Fault location on power cables

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

Gulf Cable & Electrical Ind. Co.

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

Schedule-4(A3) Page 1 of 5. Specification No.: JPL/KWTL/A3 (Package-A3) To: Bidder's Name & Address

VIPERFLEX ELECTRIC CABLE

GUIDELINES HAS/PDC/DESIGN DIVISION TITLE

CONFLEX ELECTRIC CABLE

produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.

IRRIGATION PUMPING Table of Contents - Section 900

SUPPLEMENT TO SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS

NEGRP TEST SUMMARY. Joseph A. Lanzoni, November 2005

CHAIN-LINK FENCES BID SPECIFICATIONS DESCRIPTION

SECTION SIGNAL WIRE AND CABLE

Features. Picture. Specifications

Tri-Rated Flexible PVC Equipment Wire

Building Cables and Wires

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13

18 AWG thru 8 AWG Not greater than 100/30 100/30. 6 AWG thru 1/0 AWG Not greater than 200/60 100/30

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

Exclude all sales to foreign countries and all sales or transfers to other divisions or plants of your company. Survey Form 3.3.

Gulf Cable & Electrical Ind. Co.

Specification SFTP CAT6 Network Cable 23AWG CU

Implosive Connectors. for overhead transmission lines

Armor Rods. Armor Rods NOMENCLATURE GENERAL RECOMMENDATIONS

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Outside Telephone Cable

High Voltage Systems. Today. The history of cables

CIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*

Electrical Code Regulation

Assessment of Soil Resistivity on Grounding of Electrical Systems: A Case Study of North-East Zone, Nigeria

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

ETHERLINE Ethernet Cable, Connectors & Tools

EDS KV TRIPLEX CABLE

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

Underground Service Requirements and Instructions

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

Solar Power Solutions

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

NEW SERVICE INSTALLATION STEPS. Common Slow Downs. Other Necessary Steps

800 Communications Circuits

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Transmission Silicone Insulators Line Post 69 kv to 161 kv

Modeling of Transmission Lines

PXL-250: Network Wiring

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

Chapter 9. Bonding and Grounding

East Central College HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE

5.2. Overview. The better method to install solderless compression connectors on power cable

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Konti Skan Replacement of Cable 1

Electrical Grounding. Appendix C

Power supply 142. Couplers 143. Data interfaces 144. Accessories 145

Snow/Ice Melt Heating Cable System Gutters & Roof Drains Installation Manual Nexans TXLP/1 Series Resistance Cables

CLAMPS CONNECTORS & EQUIPOTENTIAL RING

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

Video Camera Installation Guide

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

AIRPORT SECURITY FENCING. A. American Society for Testing and Materials (ASTM):

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

GUARDRAIL POST STEEL

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:

Activity 2.3b Engineering Problem Solving Answer Key

ROLINE THE Difference

GALVANIC CATHODIC PROTECTION 1.0 CONTENTS. 1.1 Aluminium Anodes. 1.2 Zinc Anodes. 1.3 Magnesium Anodes SECTION

SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.

This presentation to be used in conjunction with:

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

STABILOY BRAND FeeDeR SOLuTIONS

Electric Utility Application and Reference Guide

courtesy of Hunter Industries Inc. irrigation wiring guide

RE-ENTERABLE SPLICE CLOSURE KITS. (For Air Core None Pressurized Cable)

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

STABILOY BRAND FeeDeR SOLuTIONS

Transcription:

E1-GRD-1/5 E.1.12: GROUNDING SYSTEM B.1 Technical Characteristics and Requirements B.1.1 Grounding Design Criteria a. Fault duration, sec 1 b. Total fault level (line to ground), ka 20 c. Grounding connection Exothermic d. Grid conductor 125 mm 2 tin-annealed bare copper stranded conductor e. Bonding conductor (riser) 125 mm 2 tin-annealed copper stranded conductor with 3.3kV PVC insulation f. Burial depth of grid conductor below finished grade, m 0.50 (min.) g. Equipment and structure grounding conductor connected to different grid conductors Refer to of each equipment h. Ground mat design resistance 0.5 ohms max. i. Permissible temperature rise of grid copper Conductor, o C 300 j. Ground rod 1. Type Copperweld 2. Diameter, mm Not less than 19 3. Length/Section, m 3 k. Resistivity of crushed rock, (wet). ohm 3000 l. Approximate Area of substation to be covered by the ground grid Refer to Bid Drawings m. Soil resistivity (for calculation), ohmmeter By Contractor 1 B.1.2 Overhead Ground Wire a. Type 7 No. 8 AWG aluminum-clad steel wire b. Ultimate strength, not less than, kg 7,277 1 Design of grounding system is responsibility of Contractor including measurement of the actual soil resistivity.

E1-GRD-2/5 c. Outside diameter, mm Manufacturer s std. d. Weight of zinc coating for galvanized and aluminized steel wire if specified in item a., not less than, g/m 2 e. Weight of aluminum coating for aluminum-clad steel wire, if specified in item a., not less than, g/m 2 963 f. No. of Wires 7 g. Nominal diameter of wire, mm 3.264 h. Cross-sectional area, mm 58.561 i. Approx. weight, kg/m 0.323 k. Modulus of elasticity in kg/m 2 16,169 (final) l. Coefficient of linear expansion, x10-6 / 0 C 12.96 m. Elongation in 610 mm, not less than, % By Contractor n. Resistance at 20 C, max. 1.46267 o. Recommended length per reel, if specified, m 1,500 N/A B.1.3 B.1.4 B.1.5 B.1.5.1 Grounding Cable for Ground Mat a. Nominal sectional area, mm 2 125 mm 2 b. Construction of stranded conductor (no./dia. in mm) 19/2.68 c. Outside diameter of cable, mm 13.4 approx. d. DC Resistance at 20 0 C ohms/km 0.1641 e. Standard weight, kg/m 0.971.9 f. Tin-annealed (Yes, No) Yes Bonding Conductor (Riser) a. Size, mm 2 125 mm 2 b. Conductor Metal Tin Annealed Copper Stranded Wire c. Conductor shape Circular stranded d. Insulated? Yes e. Type of insulation PVC Accessories for Overhead Ground Wire Suspension Ground Wire Materials a. Type N/A b. Applied conductor(specify type of conductor used) N/A

E1-GRD-3/5 c. Armor rods (Specify used or not used) N/A d. Ultimate breaking strength, kg N/a e. Slip Strength, kg N/A B.1.5.2 Tension Wire Ground Materials B.1.5.2.1 Tension Clamp a. Type of Clamp Bolted b. Applied conductor (Specify type of conductor used) Aluminum-clad steel wire, 7 No. 8 AWG c. Ultimate breaking strength, kg Not less than 95% UTS of OHGW d. Slip Strength, kg 8,300 B.1.5.2.2 Jumper Clamp a. Ultimate breaking strength, kg 1,500 b. Slip Strength, kg 700 c. Type Wedge Pressure Clamp B.1.5.2.3 Parallel Groove Clamp a. Material Aluminum Alloy b. Type Bolted Type c. Applied conductor Aluminum clad steel wire 7/8 AWG d. Slip strength, kg Not less than 15% UTS of the applied conductor B.1.6 Cable Reel Requirements for the Ground Cable and Overhead Ground Wire a. Materials (specify wood or steel) Wood b. Returnable (Yes, No) No c. If Yes, return within no. of months after installation N/A B.2 Test and Test Report(s) Requirements B.2.1 Test Requirements a. Type test and/or design test reports required for the grounding conductor and materials to be supplied (Specify Yes or No) ** Yes ** Contractor shall place in the filled-in data submitted or will submit as appropriate.

E1-GRD-4/5 b. Measurement of ground grid resistance after completion of grounding system to be measured before and after connection of the external ground wires of the transmission line to the substation ground system. (Specify Yes or No) Yes B.3 Auxiliary Power Supply B.3.1 No auxiliary power supply is required.. B.4 Spare Parts B.4.1 No particular spares and spare parts are required for the grounding system. The completeness of the grounding system with measurement (step and touch potential and required ground resistance) shall be the responsibility of the Contractor before its handling-over to the Employer. B.5 Tools B.5.1 All tools, i.e. compression tools for compressing the various type of grounding connections, tools required for the installation of wedge pressure clamp, etc. necessary for completing the works for the grounding system shall be the responsibility of the Contractor before its turn over to the Employer. B.6 Other Technical Requirements for the Grounding System B.6.1 The grounding is hereby referred to Paragraph 1.12.2.2.1.3 of the Technical Specification whereby resistivity measurement including step and touch potential will be carried out and designed by the Contractor. In order to minimize the effect of seasonal variations of the earth resistance and the interruption of the overhead ground wire, the grounding system shall be designed for the worst condition, i.e. the overhead ground wire connection shall not be considered including that of the existing overhead ground wire connection. All works, labor and materials necessary for the complete, safety and efficient grounding system for the substations shall be included in the pay item for Grounding Materials for the Substation in the Bid Price Schedules for the substation. C. Other Technical Data to be Filled-in by Contractor C.1 The Contractor furnished data and information are included in this Specification to indicate the guaranteed performance data, predicted performance, interface requirements and construction features of all Contractor furnished equipment. The accuracy of such information and the compatibility of such information with overall performance requirements specified by Employer are the sole responsibility of the Contractor.

E1-GRD-5/5 C.2 Environmental Considerations C.2.1 In accordance with Paragraph 1.1.8 of the General Technical Requirements and the Technical Data Sheets of Section E.1.1, the operating environment for this installation _(will, will not ) affect the life expectancy of the components used in this equipment. If there will be an effect, the following components will be affected as follows: Component Effect C.3 Other Technical Data for the Grounding Equipment and Materials a. Country of Origin 1. Overhead ground wire 2. Copper ground conductor 3. Ground rods 4. Shield wire accessoreis: a. Tension clamps b. Suspension clamp c. Parallel groove d. Lightning rods 5. Grounding connector materials b. Manufacturers 1. Overhead ground wire 2. Copper ground conductor 3. Ground rods 4. Shield wire accessories: a. Tension clamps b. Suspension clamp c. Parallel groove d. Lightning rods 5. Grounding connector materials c. Weight of heaviest crate to be shipped, kg d. Size of largest piece to be shipped (L x H x W), mm Contractor s Data